COLUMN SUMP PUMP OPERATING & INSTALLATION INSTRUCTIONS

Similar documents
MODEL INSTALLATION INSTRUCTIONS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Installation Manual DIAPHRAGM WELL TANK

INSTANT HOT WATER RECIRCULATING SYSTEM

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

1/3 HP Submersible Sump Pump with Vertical Float Switch

101 / 105 SERIES INSTALLATION INSTRUCTIONS

Installation Manual. Model 441 Battery Backup System IMPORTANT: B. *Do not throw away or lose this manual.

ECOFILTER PUMP VAULT

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Instructions & Safety Information Models A220-20D and A220-20L Version 2

SunMaxx Solar Filling Station Operating Instructions

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Electric Water Heater

ATS Overhead Table Shelf System INSTRUCTION MANUAL

The Storm 20-Gallon Wet/Dry Vac

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

QT Residential Blower Metal Residential Blower

Mini-led spotlight with magnetic base

SERIES 101 / 105 INSTALLATION INSTRUCTIONS

100 Series Maxi Internal Filters. Instruction Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ClearView 100. Instruction Manual

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

For Models #6-5001, #6-7501, # & #10-12K1

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Installation Manual DIAPHRAGM WELL TANK

Owner s Manual & Safety Instructions

accidents which arise due to nonobservance and the safety information herein.

TROUBLESHOOTING GUIDE

SUBMERSIBLE SEWAGE PUMP 66119

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Oil and Coolant Circulating Heating System. Model - OCSM

Customer Support

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

SINGLE STAGE INLINE FIRE PUMP

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Installation, Operation, Repair and Parts Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Utility Distribution Systems

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation & Operation

OPL BASIC. Dosing System for Professional Laundry machines. Contents

American DJ. Roto-Balls VS MKII. User Instructions. American DJ

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Please also see 10 golden rules for correct Saniflo installation on

Technical Guide 08/15/14

Safety, Operation and Maintenance Manual with Parts List

IMPORTANT SAFETY RULES TO FOLLOW

Ceiling Mount Air Handler Manual

BroadBand PowerShield. User Manual

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

IMPORTANT SAFETY INSTRUCTIONS

SF15K SF05KSS, SF10KSS

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

LC-50 FOOD WASTE DISPOSER Installation Manual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

AFE424 SERVICE PARTS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation Manual Version 7.3 IMPORTANT:

OAK WORKBENCH WITH 2 DRAWERS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

CEILING CASSETTE FAN COIL UNIT

Installation Instructions

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

T-Series Air Conditioner T62 Model

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

12-Volt 10-Amp Regulated Power Supply

tire inflator with pressure gauge

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Advantium 2 Plus Alarm

Ozone Generator Manual

GAS SAFETY PRECAUTIONS

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Installation Instructions

INSTALLATION INSTRUCTIONS

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

User Manual HomeGrid 3000 Solar Generator

Transcription:

COLUMN SUMP PUMP OPERATING & INSTALLATION INSTRUCTIONS Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to the Pump Installer from whom you purchased the pump. Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. MODEL CSP33 IMPORTANT: Prior to installation, record Model, Serial Number and Date Code from pump nameplate for future reference. MODEL: SERIAL #: DATE CODE: INSTALLATION DATE: REV. A 1/21/10 Kitchener, ON 20 Steckle Place, Unit 21, N2E 2C3 Regina, SK 655 Park Street, S4N 5N1 www.novowater.com support@novowater.com 1-877-655-6686

SAFETY INSTRUCTIONS: The pump that you have purchased is produced with the latest in material and workmanship. Always remove the plug from the electrical outlet before installing the pump. Before installation and operation, we recommend the following procedures: 1. Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed with your safety in mind. Be sure you comply with them. 2. We recommend that a separate circuit be lead from the home electrical distribution panel properly protected with a fuse or a circuit breaker. We also recommend that a ground fault circuit be used. Consult a licensed electrician for all wiring. 3. The ground terminal on the three prong plugs should never be removed. They are supplied and designed for your protection. Do not use an extension cord. 4. Do not stand in water when connecting or disconnecting power cord from outlet. 5. This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter. 6. Do not pump flammable liquids with this pump as an explosion or fire could result. 7. Do not run this pump dry. Running your pump without water will damage the pump bushing, reduce the life of the pump and void the warranty. 8. This product does not require lubrication. A special oil has been put in the motor housing at the factory for lifetime lubrication of the bearings. Use of any other oil can cause and void the warranty. MATERIAL REQUIRED FOR COLUMN SUMP PUMP APPLICATION Column sump pump installation Desired length of 1 ½ (38 mm) ABS pipe Elbows and fittings to run discharge pipe ABS cement (1) - 1 ½ (38 mm) ABS coupling to connect to the pipe to check the valve (1) - 1 ¼ (32 mm) check valve Tools Required Screwdrivers Hacksaw to cut pipe Knife to assist in pipe cutting Round file to smooth pipe ends Pipe wrench Adjustable wrench to tighten fittings 2

APPLICATION This domestic sump pump is suitable for application where the total vertical distance (head) does not exceed 15 (4.6 m). It is designed as an economic and efficient means of protecting homes against water damage through seepage, where there is no natural drainage. Friction loss in pipe not included. CAPACITY: 50 USGPM (189 l/m) @ 5 (1.5 m) HD 35 USGPM (132 l/m) @ 10 (3 m) HD 15 USGPM ( 57 l/m) @ 15 (4.6 m) HD FEATURES 1 ¼ (32 mm) NPT Discharge Outlet Screened top suction inlet prevents debris from entering the pump and damaging the impeller Thermal overload motor protection Adjustable float switch for automatic operation Open-type impeller allowing small particles to pass without damage 8 foot power cord Thermoplastic and corrosion resistant pump body to ensure long life 2 Year Guarantee PERFORMANCE Column Sump Pump Specifications Model TDH * Max Flow Solids Rated Maximum Output Motor Item # Description HP Voltage Frequency Number (ft/m) (usgpm/lps) Handling Hz Amp Amp Power (W) Speed 45010007 CSP33 Column Sump Pump 17/5.2 49/3.1 1/8" 1/3 HP 115 60 4.0 8.8 250 1750 * Note: Maximum flow based on a minimum 6.5' Head 3

INSTALLATION STEPS STEP 1: STEP 2: STEP 3: Locate the rod, the float and the rubber washers in the pump carton. Secure rod s guide to pump s column. Push the rod through the rod guide, then push a rubber washer about six inches from top rod end. Insert rod end through the top mount switch opening and place the second rubber washer over the top rod end. Thread the float into the bottom rod end about six to eight turns. Depth of pumping level may be adjusted by changing the position of the lower rubber rod washer. Install the required check valve in the 1 ¼ (32 mm) discharge of the pump s base. Thread in tightly. Using 1 ½ (38 mm) ABS coupling and ABS pipes, connect the discharge line to the check valve, and run it to the desired waste location throughout the basement wall of your house. Otherwise, drain hose kits are available. You may also connect a kit to the check valve with a clamp and run the pipe to the same location. Be advised that restriction in these kits is important and increase the head of the discharge line. Position the sump pump in centre of the sump pit approximately 18 (46 cm) diameter X 25 (64 cm) deep. Plug the pump motor three prong plug/cord into a grounded electrical outlet. Fill the sump pit with water to check pump operation. Pump should start automatically when the switch lever is activated by the rubber washer and stop when the water has been discharged and the float returns to the bottom of the sump pit. EXPLODED VIEW PUMP DIMENSIONS 30.7 (780 mm) Discharge 1.25 FNPT (32 mm) 2.25 (57 mm) 11.4 (290 mm) 4

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. Motor does not run Switch is off position Blown fuse Tripped breaker Plug disconnected Corroded plug Low water level Thermal overcharge Defective switch/float Defective motor Improper float position Turn switch to on position Reset Re-install Clean prongs Add water and verify Cool the motor /repair Check movement Pump does not deliver to full capacity Jammed impeller Plugged check valve Blocked suction/inlet Discharge leak Blocked line/pipe Worn impeller Defective motor Clean Clean/replace Check for debris in pit and clean Repair Check for debris or ice Repair/replace Pump does not shut off Defective switch Float obstruction Blocked suction/inlet Adjust/check Check for debris in pit and clean Pump cycles too frequently Check valve not installed or leaking Float stops too close or repair Adjust float rod stop length 5

2 Year Limited Warranty Dynamic Pumps warrants this pump to be free from defects in material and workmanship for a period of 2 years from date of manufacture. This pump is guaranteed to do the work for which it is intended when properly installed and operated. The only exception shall be when proof of purchase or installation is provided (end user bill of sale required) and then the warranty period shall be from the date thereof. HOW TO CLAIM WARRANTY The dealer from whom you purchased your pump has a thorough knowledge of it s operation and maintenance. If trouble develops, please consult the dealer. The manufacturers obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective, provided the part or the assembly is returned freight prepaid to the manufacturer or its authorized service centre. If a unit or part should prove defective within 24 months, return it to your dealer, transportation charges prepaid. The repair will be made or a replacement unit or part will be supplied free of charge. The serial number of the unit, or unit from which the defective part is taken, must be supplied. This warranty does not oblige the manufacturer to bear the cost of field labor or transportation in connection with the replacement or repair of defective parts or units, nor shall it apply to any product upon which repairs or alterations have been made, unless authorized by the manufacturer. The manufacturer shall in no event be liable for consequential damages or contingent liabilities arising out of the failure of any product, its power unit or its accessories to operate properly. No express, implied or statutory warranty other than herein set forth is made authorized to be made by the manufacturer. 6