Start Here. Features. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide

Similar documents
Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

Power Over Ethernet Adapters POE101

Technical Support. Support Information

USB Mini Print Server PS121. Installation Guide

Copper Gigabit Switch Installation Guide

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

24 PORT. Copper Gigabit Switch Installation Guide. 10/100/1000 Mbps MODEL GS 524 T

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

MDI/MDIX) FEP-32008T-3

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

VAC 50/60Hz Power Adapter

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

8-Port PoE Network Switch

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

GEU Port Gigabit Switch

8-Port 10/100M N-Way Mini Switch

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WARNING CANADIAN D.O.C. WARNING

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Wireless Router Setup Manual

MCR1900 Media Converter 19-Slot Chassis

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

Gigabit Switching Ethernet Media Converters - Product User Guide

AXIS T81B22 DC 30W Midspan

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

16-Port and 24-Port 10/100 Switches

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

About the HotWire Slot Standalone Shelf

LMR16TC Mini 10BASE-T Repeater. Installation Guide

AXIS 291 1U Video Server Rack Installation Guide

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

GS110TP Hardware Installation Guide

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

PoE+ Extender Switch User's Manual. Rev W

Managed Layer 2 Switches GSM7212, GSM7224, and GSM7248 Hardware Installation Guide

Moxa EtherDevice Switch

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

USB Port Extender Kit

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Gigabit Desktop. manual Models & Model shown: INT / UM

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

LMR8TT Mini 10BASE-T Hub/Repeater

Hotwire 6310 MVL Modem with Inline Phone Filter Installation Instructions. Contents. Hotwire 6310 MVL Modem Overview

EKI port 10/100Base-TX Industrial Unmanaged Ethernet Switch. EKI port 10/100Base-TX Industrial Unmanaged Ethernet Switch.

FriendlyNET FX Slot Modular Switch. User s Manual

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

2-Port Gigabit Ethernet Switch Operations Guide

RC8021 Indoor Camera Installation Guide

Powerline 1200 User Manual

Hotwire 6350 ReachDSL Modem Overview

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Cisco Unified IP Phone Power Injector

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Preface. Manual Revisions

Power Supply Guide Version 1.0 for D-Show

=============================== WARNING

Ethernet 5-Port Workgroup Hub

HP Port Switches Quick Setup Guide

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Statement of Conditions Certificate of the Manufacturer/Importer Voluntary Control Council for Interference (VCCI) Statement

ProSAFE 5-port and 8-port Gigabit Switches

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

FCC COMPLIANCE STATEMENT

How To Set Up An Andsl Modem Router For Internet Access

FIBER OPTIC A/B/C SWITCH (Latching)

Modular Fast Ethernet Switch

IBM /100 Stackable Ethernet Hub

Wireless Access Point AT-WA7400. Installation Guide. PN RevA

DVI DA2 and DVI DA 4 User Guide

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

LIEBERT VNSA Installation Sheet

EKI port Industrial Unmanaged Gigabit Ethernet Switch. User Manual

AT-GS2002/SP. Gigabit Ethernet to Fiber SFP Media Converter. AT-GS2002/SP Media Converter Installation Guide. PN Rev. A

Managed Layer 2 Switch with 2 Gigabit Ethernet Ports FSM726 Hardware Installation Guide. NETGEAR, Inc. 350 E. Plumeria Drive San Jose, CA USA

Scout 1U Rackmount Computer

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

Triple Expansion Chassis

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Fast Ethernet FX-TX Media Converter. User Manual RINGDALE

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Amplifier: AMP Feature Summary

Gateway Port Replicator User Guide

Cisco Unmanaged Rackmount Switches

HP Port and 48-Port Switches Quick Setup Guide

Transcription:

Start Here The NETGEAR Model DS508, Model DS56, and Model DS524 Dual Speed Stackable Hubs are network hubs that enable users to mix and match 0 and 00 megabit per second (Mbps) devices on the same network. This mix of devices eliminates the high cost and complexity of separate network equipment for 0/00 Mbps users. All three hub models are ideal for small networks in transition from 0 Mbps to 00 Mbps operation. Up to eight hubs can be stacked so that the network can expand to serve as many as 92 users. The Model DS508, Model DS56, and Model DS524 hubs connect PCs to share printers, files, Internet access, and e-mail communications. Each network port coordinates with the connected PC to run at 0 or 00 Mbps, making network configuration and upgrade effortless. In addition, the 0 and 00 Mbps network segments are internally bridged to form one network, providing full connectivity among all users. Features The Model DS508, Model DS56, and Model DS524 hubs have the following key features: Per port, autosensing, dual-speed (0/00 Mbps) operation IEEE 802.3u standard compliance for interoperation with all 00BASE-TX Fast Ethernet (00 Mbps) products and 802.3i standard compliance for interoperation with all 0BASE-T Ethernet products Stackable architecture, allowing you to start with as few as 8 ports and expand the network as required by using the provided cascade cables (You can stack up to eight hubs for a total of 92 0 or 00 Mbps ports.) Easy Plug-and-Play installation with no software to configure, saving time and minimizing the potential for configuration errors Ability of each port on the hub to independently detect the speed of the attached device and to automatically connect at the appropriate speed Internally bridged 0 and 00 Mbps network segments to form one network, providing full connectivity among all users Built-in redundancy through the 0/00 Mbps bridge within each hub If the unit with the operating bridge fails in a stack of hubs, the next bridge will take over the function, thus ensuring connectivity among 0 Mbps users and 00 Mbps users. Furthermore, if one hub in a stack fails, the remaining hubs and ports continue to be fully functional. Stackable chassis equipped with: 8, 6, or 24 0BASE-T or 00BASE-TX ports providing fast information exchange, resource sharing, and client or peer-to-peer communication using simple Category 5 UTP wiring Vista network ports with built-in LEDs, clearly indicating individual port status Additional LEDs providing network traffic status for the hub Two LED bar graphs providing online status of network utilization and alerting you to potential network overload Normal/Uplink push button for simplifying network extension using straight-through cables Compact (3 by 8 by 7/8 inches) design that enables tabletop or rack installation Internal 00 to 240 V AC power supply Dual cooling fans (side and rear) 5-year warranty on hub unit (-year warranty on power supply)

Data Collision Power Power Data Collision 5 Link RX Normal/Uplink Package Contents Model DS508, Model DS56, or Model DS524 hub (Model DS56 shown) 7 Link RX 2 24 Rubber footpads Power cord Rack mount kit Installation guide, Warranty & Owner Registration Card Cascade cable 8672FA Verify that the package contains the following items: Model DS508, Model DS56, or Model DS524 hub Rack mount kit Cascade cable Rubber footpads for tabletop installation Warranty & Owner Registration Card Power cord Caution: Use the appropriate power cord as required by your national electrical codes and ordinances.

6PORT 0/00Mbps Collision Utilization% Power Data 0 20 >40 Auto 0/00 MbpsDUAL SPEED 00 Mbps 0 Mbps 3 00 0 5 7 00 0 00 0 2 Normal/Uplink 24 Typical Applications The Model DS508, Model DS56, and Model DS524 hubs can be used for connecting users to shared network resources such as servers, printers, and routers. All models allow for easy migration from 0 Mbps to 00 Mbps operation. Users connected at 0 Mbps can coexist with power users connected at 00 Mbps; both types of users can take advantage of shared resources connected at the higher transmission speed. The following illustration shows some typical applications of the three hub models in a mixed 0/00 Mbps environment. ISDN Printer MODEL DS524 Model DS524 hub Dual Speed Stackable Hub Model DS508 hubs Model DS56 hub Model RT328 ISDN Router 00 Mbps 0 Mbps Servers PCs Power user 8673FA

Product Illustrations Front Panel of the Model DS508 Hub 8PORT 0/00Mbps Dual Speed Stackable Hub Auto 0/00 MbpsDUAL SPEED 2 3 4 5 6 7 8 Collision Utilization% 00M 0M 00 0 00 Mbps Power 0 20 >40 0 Mbps MODEL Normal/Uplink DS508 Front Panel of the Model DS56 Hub Auto 0/00 MbpsDUAL SPEED MODEL DS56 6PORT 0/00Mbps Dual Speed Stackable Hub Collision Utilization% 00 0 00 Mbps Power Data 0 20 >40 0 Mbps 9 00 0 8 Normal/Uplink 6 Front Panel of the Model DS524 Hub 00 Mbps Collision LED 00 Mbps Utilization LEDs vista RJ-45 network ports Auto 0/00 MbpsDUAL SPEED MODEL DS524 6PORT 0/00Mbps Dual Speed Stackable Hub Collision Utilization% 00 Mbps Power Data 0 20 >40 0 Mbps 3 00 0 5 7 00 0 00 0 2 Normal/Uplink 24 0 Mbps Utilization LEDs 0 Mbps Collision LED Normal/Uplink Power LED push button 867FA

Front-Panel LEDs The Model DS508, DS56, and DS524 hubs provide front-panel LEDs for monitoring individual ports and hub status. The following table describes the front-panel LEDs and their functions. Label Color Activity Description Power Green On Power is supplied to the hub. Collision 0 Mbps Amber On Data collision is occurring on the 0 Mbps network segment (some collisions are normal). 00 Mbps Amber On Data collision is occurring on the 00 Mbps network segment (some collisions are normal). Utilization% 0 Mbps Green Blinking Indicates the amount of data traffic on the 0 Mbps segment. (If a 00 Mbps user is sending data to a 0 Mbps user, 0 Mbps utilization will be high.) 00 Mbps Green Blinking Indicates the amount of data traffic on the 00 Mbps segment. 0M or 00M Link/Receive (built into each vista RJ-45 network port) Green On A link is established successfully between the hub and the PC. Off No data link is established and/or the cable is not connected, is defective, or is the wrong type or the connected network card is not properly set up. Blinking There is incoming data on the port. Vista RJ-45 Network Ports with Built-In LEDs The front panel of the Model DS508 hub provides 8 vista RJ-45 network ports, the Model DS56 hub provides 6 vista RJ-45 network ports, and the Model DS524 provides 24 vista RJ-45 network ports. These standard RJ-45 connectors accept two-pair or four-pair Category 5 unshielded twisted-pair (UTP) copper wiring (only two pairs are used). The RJ-45 connector uses an 8-pin interface. Two LEDs are positioned at the top corners of each RJ-45 connector. The left indicator is the 00 Mbps Link/Receive LED, and the right indicator is the 0 Mbps Link/Receive LED.

vista RJ-45 network ports 00M 0M 852FA Rear Panel of the Model DS508, Model DS56, and Model DS524 Hubs Cascade Up connector Terminator LED 0/00 Mbps Bridge LED Power receptacle Cascade Up Cascade Down 0/00 Mbps Terminator Bridge 00-240 VAC 50-60 Hz 0.5A Cascade Down connector 853FA Rear Panel The rear panel of a Model DS508, Model DS56, and Model DS524 hub has two LEDs, one labeled Terminator and one labeled 0/00 Mbps Bridge. The Terminator LED indicates whether or not the built-in terminator in that hub is active (the built-in terminator eliminates the need for an external terminator). The 0/00 Mbps Bridge LED indicates which hub has the active bridge. Site Preparation Before you begin installing the hubs, prepare the installation site. Make sure your operating environment meets the operating environment requirements of the equipment. Characteristic Temperature Humidity Ventilation Operating conditions Service access Power Tabletop requirements Requirement Ambient temperature between 0 and 40 C (32 and 04 F). No nearby heat sources such as direct sunlight, warm air exhausts, or heaters. 90% maximum relative humidity, noncondensing. Minimum 2 inches (5.08 cm) on all sides for cooling. Adequate airflow in room or wiring closet. At least 6 feet (.83 m) to nearest source of electromagnetic noise (such as photocopy machine or arc welder). Minimum 2 inches (9.68 cm) front and back for service access and maintenance. Front and back clearance for cables and wiring hardware such as punchdown blocks. Adequate power source within 6 feet (.83 m). Flat area approximately 3.0 inches (33.0 cm) by 8.0 inches (20.3 cm).

Rack requirements Wiring hardware Standard 9-inch (48.26 cm) EIA equipment rack, with supplied mounting bracket hardware;.0 EIA rack-mount spaces needed for each hub. Wiring hardware, such as punchdown blocks or patch panels, should be complete before installing the hub.

3 Link RX 5 7 Link RX Link RX 2 Normal/Uplink 24 Installation Procedures Install the Hub Install the Hub on a Flat Surface If installing the hub on a flat surface such as a tabletop, make sure the bottom of the chassis is clean and dry and allow at least 2 inches of space on all sides of the hub to ensure proper ventilation.. Install the self-adhesive footpads on the bottom of the hub. 2. Set the hub on a table or shelf so that it has at least 2 inches (5 cm) of space on all sides. 3. Connect the power cord(s) first to the power entry receptacle on the hub rear panel and then to the wall. Install the Hub in a Rack To install the hub in a rack, make sure you have #2 and #3 Phillips screwdrivers. Refer to the illustration and follow the steps. #3 Phillips screwdriver (use large screws with spacers) #2 Phillips screwdriver (use small screws) Power Data Collision 845FA. Attach the mounting brackets (supplied in the rack mount kit) to the sides of the hub using the screws provided. 2. Attach the hub (with the mounting brackets) to the rack using two panhead screws with nylon washers.

Build a Larger Network Cascade up to Eight Hubs to Build a Larger Network As many as eight Model DS508, Model DS56, or Model DS524 hubs can be cascaded for up to a maximum of 92 ports in a single repeater (or collision) domain. Any device connected to one of the 92 ports at either 0 or 00 Mbps can connect through the network to any other device attached to the cascade stack. The stack of eight hubs can consist of any combination of Model DS508, Model DS56, and Model DS524 hubs daisy-chained together using the supplied cascade cable. The LEDs in the following illustration appear as they would in an operational stack of hubs. Terminator LED On Cascade Up Cascade Down 0/00 Mbps Terminator Bridge 00-240 VAC 50-60 Hz 0.5A Cascade Up Cascade Down 0/00 Mbps Terminator Bridge 00-240 VAC 50-60 Hz 0.5A Cascade Up Cascade Down 0/00 Mbps Terminator Bridge 00-240 VAC 50-60 Hz 0.5A Cascade Up Cascade Down 0/00 Mbps Terminator Bridge 00-240 VAC 50-60 Hz 0.5A Bridge LED On Terminator LED On 8099FA The cascade connectors on the Model DS508, Model DS56, and Model DS524 hubs use a shared circuit. When power is supplied to one of the hubs in a stack, the Terminator LED in the top hub of the stack and the Terminator LED and 0/00 Mbps Bridge LED in the bottom hub of the stack will be on. If power is disconnected from the bottom hub in the stack, the hub above it takes over the bridge function. Furthermore, the remaining hubs continue to operate if power is disconnected from one hub in the stack.

Data Collision Power Power Data Collision 5 7 Link RX Link RX 2 Normal/Uplink 24 Connect a PC to the Hub 8094FA Caution: 00 Mbps operation requires the use of Category 5 UTP wiring with 00 Mbps certified connectors. NETGEAR highly recommends using Category 5 cable so your network can operate at either 0 or 00 Mbps. Set Normal/Uplink Push Button The Normal/Uplink push button on the front panel of the hub allows you to select the Uplink (MDI) or Normal (MDI-X) position for port 8 on the Model DS508 hub, port 6 on the Model DS56 hub, and port 24 on the Model DS524 hub. All other ports are wired Normal for direct connection to PCs. Select Normal if connecting a PC, server, or router to the port. Select Uplink if connecting a hub or switch. The Normal/Uplink push button eliminates the need to use a crossover cable. Verify Your Installation When installation is complete and power has been applied to the hub, the following conditions should exist: Power LED is on. Link LED on each connected port is on. Utilization LEDs on the front panel are blinking when data is being received by any port in the hub, and the Link/Receive LED on the connected port is blinking when data is being received by that port. With a single hub, the Terminator and Bridge LEDs in the rear panel are on. With a stack of hubs, the Terminator LEDs in the top and bottom hubs are on. The Bridge LED in the bottom hub is on. If there are any problems, refer to the Troubleshooting table.

Cable & Connector Information Twisted Pair Cables For two devices to communicate, the transmitter of each device must be connected to the receiver of the other device. The crossover function is usually implemented internally as part of the circuitry in the device. Most repeaters and switch ports are media-dependent interfaces with crossover ports, referred to as MDI-X or Normal ports. Computers and workstation adapter cards are usually media-dependent interface ports, referred to as MDI or Uplink ports. The figures illustrate the use of straight-through and crossover twisted pair cables. Uplink or MDI port Straight-through twisted pair cable Normal or MDI-X port Tx 2 2 Rx Rx 3 6 3 6 Tx Normal or MDI-X port Crossover twisted pair cable Normal or MDI-X port Rx 2 2 Rx Tx 3 6 3 6 Tx RJ-45 Connector 846EB The RJ-45 connector (shown in the illustration with an RJ-45 plug) is used to connect workstations, hubs, and switches through unshielded twisted pair cable. The RJ-45 connector accepts four-pair Category 3 or Category 5 UTP cable. 2345678 8 7EA

RJ-45 Connector Pin Assignment Normal Assignment on Ports 8, 6, or 24 Uplink Assignment on Port 8, 6, or 24 Input Receive Data + Output Transmit Data + 2 Input Receive Data - Output Transmit Data - 3 Output Transmit Data + Input Receive Data + 6 Output Transmit Data - Input Receive Data - 4, 5, 7, 8 Not used Not used Troubleshooting Information Symptom Cause Solution Power LED off No power at hub Check the power cord connections. Terminator LED of a middle hub in a stack is on Link LED off or intermittent Collision LED on or blinking Problems with port 8 on the Model DS508 hub, port 6 on the Model DS56 hub, or port 24 on the Model DS524 hub In a stack, no power at hub but Terminator LED is on Cascade cable not connected properly Port connection not functioning Collisions taking place on network segment(s) Normal/Uplink push button in the wrong position Check the power cord. In a stack, the termination circuitry gets power from the cascade cable. If one hub in the stack has a faulty power cord or the cord is unplugged, the Terminator LED remains on and the remaining hubs in the stack operate normally. Check for proper connection. Check the crimp on the RJ-45 connectors and make sure that the plug is properly inserted and locked into the port at both the hub and device. Make sure cabling is Category 5 and meets the requirements for 00 Mbps operation. Check installation of the network interface cards and verify that they are 00 Mbps capable. Be sure that the proper software driver is loaded. Check link LEDs on the network adapter card and PC or workstation. Make sure cables and connectors are correct. Collisions are normal on Ethernet networks. Excessive collisions can be caused by incorrect cabling, connectors, or wiring techniques or can occur when the network is too busy. Ensure that the far end is set to half-duplex mode and is operating properly. Check for these problems. Check the Normal/Uplink push button on the front panel.

Technical Specifications Specification Model DS508 Model DS56 Model DS524 RJ-45 Network Ports 8 Ports 6 Ports 24 Ports Dimensions Width: Height: Depth: Weight AC Power 3.0 in. (330 mm).7 in. (43 mm) 8 in. (202 mm) 4.7 lb (2. kg) 0.5 Amps maximum Input Voltage Autosensing 00 to 240 V, 50/60 Hz Standards Compliance Status LEDs Unit: 0 Mbps network segment: 00 Mbps network segment: Per UTP port: Rear panel: Environmental Specifications Operating temperature: Operating humidity: Electromagnetic Emissions Safety Agency Approvals 4.9 lb (2.2 kg) IEEE 802.3i 0BASE-T IEEE 802.3u 00BASE-TX Power Utilization %, collision Utilization %, collision 0 or 00 Mbps operations Link, Receive data Cascade Termination, 0 to 00 Mbps Bridge 0 to 40 C (32 to 04 F) 90% maximum relative humidity, noncondensing CE mark, commercial FCC Part 5, Class A EN 55 022 (CISPR 22), Class A VCCI Class CE mark, commercial UL listed (UL 950) CSA certified (CSA 22.2 #950) TUV licensed (EN 60 950) 5. lb (2.3 kg)

2000 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of NETGEAR, Inc. Windows is a registered trademark of Microsoft Corporation. Other brand and product names are trademarks or registered trademarks of their respective holders. Information is subject to change without notice. All rights reserved. Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. Certificate of the Manufacturer/Importer It is hereby certified that the Model DS508 Dual Speed Stackable Hub, the Model DS56 Dual Speed Stackable Hub, and the Model DS524 Dual Speed Stackable Hub have been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/99 and Vfg 46/992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations. Voluntary Control Council for Interference (VCCI) Statement This equipment is in the first category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in commercial and/or industrial areas. Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment such as radios and TV receivers. Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 5 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. EN 55 022 Statement This is to certify that the Model DS508 Dual Speed Stackable Hub, Model DS56 Dual Speed Stackable Hub, and Model DS524 Dual Speed Stackable Hub are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22). This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take appropriate measures. Canadian Department of Communications Radio Interference Regulations This digital apparatus (Model DS508 Dual Speed Stackable Hub, Model DS56 Dual Speed Stackable Hub, and Model DS524 Dual Speed Stackable Hub) do not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications. Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique (Model DS508 Dual Speed Stackable Hub et Model DS56 Dual Speed Stackable Hub et Model DS524 Dual Speed Stackable Hub) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.

NETGEAR Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: -888-NETGEAR e-mail: support@netgear.com Customer Support Phone Australia: 800-787-638 Austria: 00800-06384327 (00800-0-NETGEAR) Denmark: 808-8279 Canada: -888-NETGEAR Finland: 0800--036 France: 0800-77-7-53 Germany: 00800-06384327 (00800-0-NETGEAR) Hong Kong: 00-800-233-4566 Japan: 020-66-5402 Korea: 00308--039 Netherlands: 0800-023-098 New Zealand: 00800-233-4566 Norway: 800-204 Singapore: 00-800-233-4566 Sweden: 0200-298-298 Switzerland: 00800-0638-4327 (00800-0-NETGEAR) United Kingdom: 020-726-004 United States: -888-NETGEAR All Other Countries: + 80-236-8499 Internet/World Wide Web The NETGEAR Web page is at http://www.netgear.com. Defective or damaged merchandise can be returned to your point-of-sale representative.