Precision thermometer Model CTR5000

Similar documents
Hand-held thermometer Model CTH7000

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Multi-Range Programmable DC Power Supplies 9115 Series

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

4-Channel Thermometer / Datalogger

Multi-Range Programmable DC Power Supplies 9115 Series

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Duct Humidity Transmitter

Temperature & Humidity SMS Alert Controller

1.44 kw Programmable DC Power Supplies XLN Series

Precision digital pressure gauge Model CPG1500

Pressure transmitter For general industrial applications Model A-10

DC Electronic Loads 8500 series

OZW30. Central Unit SYNERGYR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Compact pressure switch Flameproof enclosure Ex d Model PCA

Physical Specifications (Custom design available.)

T Substation Maintenance and Commissioning Test Equipment

Test equipment for temperature and its reduction

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Voltage Regulator SPAU 341 C. Product Guide

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Disturbance Recoder SPCR 8C27. Product Guide

Wahl C50 Calibrator FEATURES

Series 6000 Torque measured metal bellow coupling

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RAINCONTROL LCD Special

Quick Connect. quick - simple - efficient.

Digital input modules

Panel PC SIMATIC HMI IPC577C

TX OPEN RS232/485 module

FIREDEX Conventional Fire Panels

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Multi-Function Ground

High Power Programmable DC Power Supplies PVS Series

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Product Information Sheet UH36 Hi Pot Tester

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Multi Media Cable Tester TM-901N/TM-902/TM-903

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DPI 260 SERIES: Digital Pressure Indicators

DS 600. A contact free flux gate based current measurement sensor 600A rms

HMI display Installation Guide

Material test chamber with mechanical convection

CYMAQ Marking System AS200 + DS7050 N-14

Bimetal thermometer Model 52, industrial series

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Integrated KVM 2-Port Switch

Electronic Control Devices The European Product Catalogue 2007

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

3500/62 Process Variable Monitor

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

How To Use An Hm804X Series Of Power Supplies

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

J TB/TW Temperature limiter, temperature monitor

DCS Data and communication server

Modular I/O System Analog and Digital Interface Modules

MapIT G2 Infrastructure Management

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Digital inductive conductivity transmitter

DAB+ / FM Tuner Model: TU-201

User Guide. Temperature and Humidity Datalogger. Model 42280

Electronic Control Devices The European Product Catalogue 2007

Preset Counter signo 721

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

NC-12 Modbus Application

A project to optimise quality and energy efficiency must include metering

SIMATIC Flat Panel Monitors

Portable digital microprocessor thermometers with interchangeable probes

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Waveguide Access Point WGA631. Product Guide

BB-18 Black Body High Vacuum System Technical Description

SNMP Web Management. User s Manual For SNMP Web Card/Box

5000V Graphical Megohmmeter Model 5070

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

PCS0100en Persy Control Services B.V. Netherlands

TMS TANK MANAGEMENT SYSTEM

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Current Monitoring Kit QUICK START GUIDE

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Transcription:

Calibration technology Precision thermometer Model CTR5000 WIKA data sheet CT 60.20 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference instrument for testing, adjusting and calibrating temperature measuring instruments in factories and calibration laboratories Self-contained, complete system also suitable for on-site measurements/calibrations Special features Temperature range -200... +962 C Accuracy: 0.01 C, optional 0.005 C 2 channels as standard with optional 4 or 6 channels Expandable up to an additional 64 channels with multiplexers SMART probe review and editor Precision thermometer model CTR5000 with model CTS5000 multiplexer Description The model CTR5000 precision thermometer also comes with two channels as standard, but four and six channel variations are available with each channel able to work with up to 70 user-defined probes so providing spot on calibration. It can also provide a sequential channel scan with a data logging function that can also be sent to PC or USB memory stick. The CTR5000 also offers single, differential and alternative measurement modes with the ability to provide direct comparison calibration. Using calibrated probes with the precise thermometer choose between storing the calibration data into the memory of the instrument or if using ASL SMART probes can be entered into these. The SMART probe data can also be reviewed and edited therefore easy calibration of ASL SMART probes. The instrument can also generate coefficients from reference temperature/resistance data pairs. The instrument is capable of measuring temperature ranges to meet ITS 90, CVD, EN 60751 and IEC 751 standards and results are delivered via a LCD backlit display with large numeric, statistical or graphical information. It also comes with USB interface as standard, but optional RS-232, IEEE or LAN interfaces are also available. To ensure long term reliability the precision thermometer uses surface mount technology with no mechanical relays or potentiometers. WIKA data sheet CT 60.20 11/2014 Page 1 of 6 Data sheets showing similar products: Reference thermometer; model CTP5000; see data sheet CT 61.20

Specifications Model CTR5000 Hand-held thermometer Probe types Measuring inputs Data entry format Measuring ranges Probe current Temperature range Accuracy 1) Industrial platinum resistance thermometers (PRTs) and standard platinum resistance thermometers (SPRTs) with R o = 25 Ω and 100 Ω up to an alpha of 0.00392 2 (front panel), 4 or 6 (rear panel) Expandable up to an additional 64 channels with CTS5000 multiplexers ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes Optional: coefficient generation from data pairs 1 ma (Pt100); optional auto-select 1 ma, 2 ma -200... +962 C, depending on thermometer probe 0.01 K, optional 0.005 K 1) The accuracy in K defines the deviation between the measured value and the reference value. (Only valid for indicating instruments.) Digital indicator Display Screen Resolution LCD screen with backlighting 0.001 C, 0.0001 Ω (user selectable) Functions Memory (optional) Real-time clock Sequential scan of all channels (only when a model CTS5000 multiplexer is used) log up to 8,000 individual readings to internal memory export logged data directly from PC or USB memory stick integrated clock with date and year Voltage supply Power supply Power consumption Fuse AC 90... 264 V, 47... 63 Hz; universal rear input on rear panel max. 25 VA AC 250 V, 1 A (anti surge) Permissible ambient conditions Operating temperature 15... 25 C Storage temperature -20... +50 C Communication Interface Case Standard: USB Optional: RS-232, IEEE-488.2 or LAN (Ethernet) Dimensions 260 x 80 x 270 mm (W x H x D) Weight 2.7 kg CE conformity, certificates CE conformity EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (portable test and measuring equipment) Certificates Calibration 2) Standard: 3.1 calibration certificate per DIN EN 10204 Option: DKD/DAkkS calibration certificate Recommended calibration interval 1 year (depending on the conditions of usage) 2) Only system calibration Approvals and certificates, see website Page 2 of 6 WIKA data sheet CT 60.20 11/2014

Dimensions in mm Temperature sensors (immersion probe) Resistance thermometer Spring strain relief Engraved line ø 6 or ø 7 Centreline of sensor 2 metres nominal 300 mm maximum insertion depth 350 or 450 Model Dimensions Temperature range Detector length CTP5000-250 Pt100, d = 6 mm, l = 350 mm -50... +250 C 25 mm CTP5000-450 Pt100, d = 6 mm, l = 350 mm -80... +450 C 25 mm CTP5000-652 Pt100, d = 6 mm, l = 450 mm (without spring strain relief, -70... +650 C 30 mm 100 mm handle) Resistance thermometer Brazed weld 3 metres Model Dimensions Temperature range Detector length CTP5000-200 Pt100, d = 3 mm, l = 30 mm -50... +200 C 6 mm WIKA data sheet CT 60.20 11/2014 Page 3 of 6

Resistance thermometer connection, 4-wire (5-pin DIN connector) View towards front panel connector Shield Viewed from top panel Shield Options With DIN plug or SMART plug With ASL's SMART connector on the probes, storing the data is needed only once - in the connector! The calibration data stays with the probe - permanently. It can even be used on another instrument without any further action. The SMART connector saves time and reduces error. If there are existing calibrated or uncalibrated probes, no problem, CTR5000 automatically registers if a probe is SMART or normal. Features of the precision thermometer Simple handling Graphical LCD for excellent viewing of results and instrument settings AC technology: Immunity to most sources of errors present in DC bridges Statistical, graphical and large display modes Expandable multi-channel input multiplexing (up to 64 additional channels) USB interface as standard for automated monitoring and calibration applications Front panel 1 2 3 4 5 A C ha IT S 90 P b09 12:02:03 C 132 041 E s c M e n u 1 2 3 4 5 6 7 8 9 B C h a n Z e r o H o l d U n i t 0 8 7 6 1 Inputs 2 LCD 3 Status line 4 6 soft keys 5 Numeric keypad 6 USB interface 7 Status LED 8 Status icons Page 4 of 6 WIKA data sheet CT 60.20 11/2014

Operation The instrument s keys are grouped by type and consist of six soft-keys and a twelve-key numerical keypad. The soft keys are used to access data and/or functions within the instrument. The CTR5000 keypad is shown in detail below. The keys are used to select the various functions and menu options and to control the instrument. Generally, all commonly used functions are available at the top level and no more than one or two menu levels are below the other commonly used settings. A few (infrequently used options) require three or four menu levels. The soft-keys are used to select common functions, Chan, Zero, Hold and Unit. The blue display key is used to select other display modes. All other settings and functions are accessed via the menu key. The numeric keypad is used to enter numerical values or to directly select a measurement channel 10 or menu. Instrument functions keys Key Description Function Chan Select input channel Displays the channel select options Zero Zero display measurement Toggles the display zero (null) function Hold Hold display measurement Toggles the display hold (measurement continues) Unit Select display units Rotates through the display units (W, C, F or K) Esc Escape Returns without action. The LCD is redrawn Menu Display menu Used to select all options and functions Numeric keypad Key Description Function 0... 9 Numerical data entry Enters a numerical digit, selects a numeric menu or selects a channel Enter Enter data Used to select a measurement channel or after numerical data entry Disp Display mode Changes the LCD between the 4 display modes in normal, large, statistical and graph Additional features of the accuracy version of 0.005 K Additional 25 Ω reference resistor Coefficient generation from data pairs Internal logging External logging Full SCIPI command set Channel scanning WIKA data sheet CT 60.20 11/2014 Page 5 of 6

Scope of delivery Model CTR5000 precision thermometer incl. power cord and USB cable Choice of model CTP5000 temperature probes Choice of model CTS5000 multiplexer Option DKD/DAkkS calibration certificate 1) UKAS calibration certificate 1) 1) Only system calibration Accessories Expansion model CTR5000 2 Channels expansion card (Maximum of 2 expansion card per CTR5000) Temperature probes model CTP5000 Immersion probe Customer-specific probes are available on request Multiplexer model CTS5000 8-Channel multiplexer (Maximum of 4 multiplexer per CTR5000) 16-Channel multiplexer (Maximum of 4 multiplexer per CTR5000) Test case Transport case, robust Interface Interface card RS-232 Interface card IEEE Interface card LAN (Ethernet) Software ULog Ordering information CTR5000 / Number of channels / Accuracy / Interface / Numbers of multiplexer CTS5000 / Number of channels per multiplexer CTS5000 / Transport case / Additional order information 2013 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 6 of 6 WIKA data sheet CT 60.20 11/2014 11/2014 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de