Surface Resistance Test Kit

Similar documents
Tech Brief Surface Resistance Test Kit Operation and Maintenance

ACL 800 MEGOHMMETER OPERATION MANUAL

ACL 395 Resistivity Meter

ExStik TM ph Waterproof Meters

Periodic Verification System Model 775PVS

12-Volt Negative Ground Installation Instructions

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Wireless Indoor/ Outdoor Thermometer

3M Wrist Strap and Footwear Tester 740. User s Guide

Unattended Answering Device Instruction Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Dual Laser InfraRed (IR) Thermometer with Color Alert

Wireless Base Station Single and Multiple Headsets

Mold Alert... Operation Manual P0270

AutoRanging Digital MultiMeter

Weather Radio Alarm Clock

TC-9102 Series Surface Mount Temperature Controllers

Temperature Humidity Meter

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Instructions & Safety Information Models A220-20D and A220-20L Version 2

TABLE OF CONTENTS 11.0 WARRANTY

Single Station Remote Alarm

Instruction Manual Temp 4/5/6 Temperature Meter Series

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

Thermistor Thermometer MODEL NO

Manual Ranging MultiMeter

EzFlex Combustible Gas Leak Detector Model EZ40

i410/i1010 AC/DC Current Clamp

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Universal Wireless Effects Controller USER S GUIDE SA115

Advantium 2 Plus Alarm

How To Use A Cdm250 Digital Multimeter

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Part I - Installation

Microwave Meter. Instruction Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Light Meter (Foot Candles)

Alarm Clock USER GUIDE

Intelli-Time Alarm Clock model 13027

Dual Laser InfraRed (IR) Thermometer

Global Water Instrumentation, Inc.

62 Max/62 Max + Infrared Thermometer

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Wolverine Data PASS Portable Scanner User Manual V1.0

CT-001, CT-001-Solar Owner s Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

1 For All Non-Programmable Digital Thermostat

323/324/325. Calibration Manual. Clamp Meter

Alarm Clock USER GUIDE

HOW TO INSTALL YOUR BOOST CONTROLLER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Installation and Operation Guide for PD5100 Automatic Transfer Switch

HVAC Clamp Meter. Users Manual

Owner s Manual & Safety Instructions

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Seven function digital multimeter

ACL 600 Stati-Check Meter

Digital Fingerprint safe

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

High Temperature InfraRed Thermometer with Laser Pointer

Automatic Wrist Blood Pressure Monitor with

3 740 Wrist strap + shoe tester

OAK WORKBENCH WITH 2 DRAWERS

Intercom and Music System Bluetooth Player Operation & User s Guide. DMC System Master with DMCBT Bluetooth Player

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

INSTRUCTION MANUAL DTH Fax: (503)

User's Guide Integrating Sound Level Datalogger Model

Models CT-001, CT-002 Owner s Manual

Temperature, Humidity & Dew Point Chart Recorder

Installation Instructions

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage S... Digitalvåg U.S.A. and countries outside the EU...

AM/FM PLL Clock/Table Radio

USB Rover port USB m Cat 5 Extender. User Guide

Amplified High Speed Fiber Photodetectors

User Guide. 4 wire Earth Resistance Tester Model GRT300

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Example ESD Control Program Document Based on ANSI/ESD S

Automatic Phone-Out Home Monitoring Systems

Ground Resistance Clamp-On Tester

Installation Instructions

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

2GB MP3 Player USER GUIDE

How To Use The Visifault Visual Fault Locator

12 Volt 30 Amp Digital Solar Charge Controller

Mini-led spotlight with magnetic base

W ant to accomplish something

InHome Water Leak Detection Package

Sip/Puff Switch User Guide

Atomic Alarm Clock model 13131W2

Mini Power Bank and Charger

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Universal Laptop Charger

Hygro-Thermometer + InfraRed Thermometer Model RH101

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Die-Cast Metal, Motion- Activated Post Light

Dual Laser InfraRed (IR) Thermometer

Model SRMD Setra Remote Monitoring Display

Transcription:

Instruction Manual for Surface Resistance Test Kit Model 292 Printed in USA Copyright Monroe Electronics, Inc. Specifications subject to change without notice. P/N 0340180 10/04/02 100 Housel Ave PO Box 535 Lyndonville NY 14098 585-765-2254 fax: 585-765-9330 monroe-electronics.com Page 1 of 9

Warranty Monroe Electronics, Inc., warrants to the Owners, this instrument to be free from defects in material and workmanship for a period of two years after shipment from the factory. This warranty is applicable to the original purchaser only. Liability under this warranty is limited to service, adjustment or replacement of defective parts (other than tubes, fuses or batteries) on any instrument or sub-assembly returned to the factory for this purpose, transportation prepaid. This warranty does not apply to instruments or sub-assemblies subjected to abuse, abnormal operating conditions, or unauthorized repair or modification. Since Monroe Electronics, Inc. has no control over conditions of use, no warranty is made or implied as to the suitability of our product for the customer s intended use. THIS WARRANTY SET FORTH IN THIS ARTICLE IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REPRESENTATIONS, EXPRESS, IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. Except for obligations expressly undertaken by Monroe Electronics, in this Warranty, Owner hereby waives and releases all rights, claims and remedies with respect to any and all guarantees, express, implied, or statutory (including without limitation, the implied warranties of merchantability and fitness), and including but without being limited to any obligation of Monroe Electronics with respect to incidental or consequential damages, or damages for loss of use. No agreement or understanding varying or extending the warranty will be binding upon Monroe Electronics unless in writing signed by a duly authorized representative of Monroe Electronics. In the event of a breach of the foregoing warranty, the liability of Monroe Electronics shall be limited to repairing or replacing the non-conforming goods and/or defective work, and in accordance with the foregoing, Monroe Electronics shall not be liable for any other damages, either direct or consequential. Return Policies and Procedures FACTORY REPAIR: Return authorization is required for factory repair work. Material being returned to the factory for repair must have a Return Material Authorization number. To obtain an RMA number, call 585-765-2254 and ask for Customer Service. Material returned to the factory for warranty repair must be accompanied by a copy of a dated invoice or bill of sale, which serves as a proof of purchase for the material. Repairs will be returned promptly. Repairs are normally returned to the customer by UPS within ten working days after receipt by Monroe Electronics, Inc. Return (to the customer) UPS charges will be paid by Monroe Electronics on warranty work. Return (to the customer) UPS charges will be prepaid and added to invoice for out-of-warranty repair work. EXPEDITED FACTORY REPAIR: All material returned to the factory by air or by an overnight service will be expedited. Expedited factory repairs will be returned to the customer by the same mode of transportation by which the material was returned to the factory for repair (i.e., material returned to the factory by an overnight service will be returned to the customer by an overnight service). NOTE: Return (to the customer) transportation expenses for expedited factory repairs will always be at the expense of the customer despite the warranty status of the equipment. FACTORY REPAIRS TO MODIFIED EQUIPMENT: Material returned to the factory for repair that has been modified will be not tested unless the nature and purpose of the modification is understood by us and does not render the equipment untestable at our repair facility. We will reserve the right to deny service to any modified equipment returned to the factory for repair regardless of the warranty status of the equipment. Page 2 of 9

Specifications Range: Accuracy: 1.0 x 10 3 to 1 x 10 12 @ 10V 1.0 x 10 7 to 1 x 10 12 @ 100V 1.0 x 10 3 to 9.9 x 10 6 @ 10V 10% of reading at 70-80 0 F; 15 60% RH 1.0 x 10 7 to 1 x 10 12 @ 100V 10% of reading at 70-80 0 F; 15 60% RH Open Circuit Voltages: 10 and 100 volts 3% Electrification Period: Temperature Accuracy: Relative Humidity: Power: Meter Jacks: Test Leads: 15 seconds 5 degrees F and 3 degrees C Typ. Range from 5% - 95%; 10% Typ. Two - Alkaline AA batteries Battery Life: approximately 1500 measurements. Left jack on meter accepts a 3.5 mm plug Right jack on meter accepts a standard banana plug Black lead terminated with a 3.5 mm plug one end and a standard banana plug on the other White lead terminated with a standard banana plus both ends External Electrodes: Two NFPA-99 5-pound electrodes ( 80 oz.) 2oz with Shore A (IRHD) 50 70 durometer conductive pads that comply with EOS/ESD S4.1 Resistivity Electrodes: Parallel conductive silicone rubber electrodes 4 inches long and spaced 4 inches apart mounted onto an adapter sled Meter Weight: Dimensions: 15.5 oz. With out adapter; 23 oz. with adapter 8 L x 4.3 W x 1.6 H Kit includes: Meter Protective carrying case Test leads Two NFPA-99 5-pound electrode weights Two AA Alkaline batteries Operator s Manual Resistivity adapter sled is optional and must be ordered separately. Specifications are subject to change without notice. Page 3 of 9

Description Monroe Model 292 Digital Surface Resistance Test Kit is a portable, versatile, instrument designed to accurately measure resistance between two points (RTT), surface to ground (RTG), and surface resistivity in accordance with EOS/ESD Association standard S-4.1. In addition, the meter measures ambient temperature and relative humidity. The Surface Resistance Meter is designed to make measurements in accordance with specified test methods on: Work surfaces ANSI/ESD S4.1 Work surfaces Resistance Measurements Floors ANSI/ESD S7.1 Resistive Characterization of Materials Floor Materials Footwear ANSI/ESD S9.1 Footwear- Resistive Characterization Garments ANSI/ESD STM 2.1 Garments Seating ANSI/ ESD STM 12.1 Seating Resistive Measurement Floor/Footwear ANSI/ESD STM 97.1 Floor Materials and Footwear Resistance Measurement in Combination with a Person Workstations ANSI/ESD-AVD 53.1 ESD Protective Workstations Electrification Period The 292 Surface Resistance Test Kit provides the proper electrification period of 15 seconds per ANSI/ESD S4.1. Liquid Crystal Display (LCD) A 3.5 digit 9/16 high, liquid crystal display provides easy to read measurements directly from the meter. No interpretations or calculations are required. Surface resistance ohm values are expressed by the LCD and an illuminated LED which indicates the reading s exponential value. For example: if the LCD reads 6.52 and the LED adjacent to the 8 is illuminated, the measurement is 6.52 x 10 8 ohms or 652,000,000 ohms. If the surface resistance is over 10 12 ohms, the following will appear on the LCD display: 1. indicating that the reading exceeds the unit s capabilities. LED Displays Surface resistance exponents are displayed via 12 light emitting diodes (< 10 3 - >10 12 ). LEDs are color coded for quick check recognition. Five additional Function LEDs, located to the right of the red test button, identify the measurement taken when lit. When battery voltage drops to approximately 2 volts, one of the Function LEDs will begin to flash, indicating the need to replace the batteries. Test Button The red test button activates electrical power to the meter. When the test button is depressed and held the exponent LED is lit immediately. During the meter s electrification period the LCD will display the temperature in Fahrenheit for 5 seconds, the temperature in Celsius for 5 seconds, then the Relative Humidity as a percent for 5 seconds, and then the surface resistance measurement in decimal notation. Page 4 of 9

Override Test Range Voltage Button The button is a switch, which if depressed will override automatic voltage selection and test will be performed at 10 volts regardless of resistance level. When in the up or Auto position, during resistance portion of test, meter will automatically switch to the correct voltage for the resistance range. A function LED will light to indicate selected voltage. Conductive material 10 5 ohms or less is measured at 10 volts. Dissipative material 10 6 ohms or greater is tested at 100 volts. Jacks The left hand jack on the meter accepts a shielded 3.5mm plug. The right hand jack accepts a standard banana plug. Test Leads One end of the black test lead provided is terminated with a 3.5mm plug and fits the left meter jack. The 3.5mm plug is shielded per ESD S4.1 (Refer to RTG test procedure later in this manual.) The other end of the black test lead and both ends of the white test leads are terminated with a standard banana plug. Battery Replacement The battery compartment is located in the bottom end of the unit. Depress the two buttons on the sides of the bottom end cap and remove cap. Press on the right edge of the protruding battery door to unlatch it and swing the door open. Observe polarity and carefully replace the batteries with alkaline Type AA. Polarity must be correct or damage may occur. Close battery door and reinstall bottom end cap onto meter case. Cleaning and Maintenance Work surfaces or material to be tested should be cleaned prior to testing to ensure that surface dirt and contamination do not affect the test results. Periodically clean the two 5-pound conductive rubber probe electrode surfaces. Use solvent free rubber cleaners. We recommend using an antistatic cleaner or Stat Wipes, pre-saturated cleaning wipes. Make sure the surface is dry before testing. The 292 Surface Resistance Test Kit requires little maintenance with no user serviceable parts. If your meter requires service beyond cleaning the electrodes or changing the batteries, please contact the factory. Calibration Monroe Electronics instruments are factory-calibrated prior to shipment. Recalibration should be performed annually, or more frequently if specified by contract or company policy. Your instrument should also be recalibrated any time it has been repaired or tampered with. We are happy to recalibrate your instrument for you at a reasonable cost, or provide information and procedures on calibration upon request. Page 5 of 9

Literature References Monroe Electronics recommends that anyone using Model 292 read the following standards from the ESD Association: EOS/ESD-ADV1.0 Glossary of Terms EOS/ESD-S4.1 Work surfaces EOS/ESD-S6.1 Grounding ESD-S7.1 Floor Materials EOS/ESD-S11.11 Surface Resistivity These documents are available directly from the ESD Association 7900 Turin Road Suite 4 Rome NY 13440-2069 (315) 339-6937 General Guidelines for Testing Use both 5-pound electrodes for RTT (Resistance between two points) testing. Use one 5-pound electrode and one lead to a groundable point for RTG (Resistance to Ground) testing. Use the optional resistivity adapter sled (removing leads and electrodes) for Resistivity measurements. Make sure that the item being measured is electrically isolated (i.e. placed on an insulative surface) as the meter will measure the lower resistance path. Make sure that the test leads are separated or the meter may measure the lower resistance path When using the 5-pound electrodes: o o o o Place the electrodes no closer than 2 inches from edge of surface being measured. Place the electrodes no closer than 3 inches to any groundable point Preferred placements include: most commonly used surface portion, most worn, center, and furthest from a groundable point. For RTG, connect the sensing lead with shielded plug to the groundable point. If the surface has sections (like tile flooring or garment panels), for RTT place the electrodes on different sections. Page 6 of 9

RTT - Measuring Resistance Between Two Points Point to point surface resistance measurements are made using the meter with both of the 5-pound weight electrodes. This test determines the resistance two points independent of a ground point. To perform surface resistance tests you must first determine what test procedure to use. The test procedure helps you determine the proper preparation of the material to be tested and the spacing of the weights. Once the testing parameters are determined proceed with set up for point-to-point testing. Connect the test leads to the meter and the 5-pound electrodes in a set up similar to the one shown above. Place both electrodes on the material at positions determined by the procedure selected. Set the meter to the required test voltage as specified in the test procedure and the resistance of the material. Press and hold the red test button for at least 15-20 seconds. The LCD expresses surface resistance ohm values and an illuminated LED indicates the reading s exponential value. Page 7 of 9

RTG Resistance to Ground Measurements Resistance to ground measurements indicate the surface resistance between selected locations on a work surface and a groundable point or points. Ground points are usually in the form of snaps installed on the material so that the material can be grounded via ground cords. The charge dissipative rate of all ESD protective materials is related directly to electrical resistance to ground. When making Resistance-to-Ground measurements follow this procedure: To GND Connect the black test lead to the left hand jack on the meter and to ground. Connect the white test lead to the right hand jack on the meter and to the 5-pound electrode. Place the electrode on the material at the position specified by the procedure selected. Set the meter to the desired voltage range. Be sure to keep the cords separated in order to prevent false readings, especially when testing high resistance materials. Press and hold the red test button for at least 15-20 seconds. The LCD expresses surface resistance ohm values and an illuminated LED indicates the reading s exponential value. Repeat the procedure to measure other points on the material under test. Page 8 of 9

Surface Resistivity Measurements To make surface resistivity measurements the user must also have the optional resistivity adapter sled, Model 292/41. The meter attaches easily to an optional resistivity adaptor sled. Parallel silicone rubber electrodes provide for direct measurement of surface resistivity. No conversion is required with the Surface Resistivity Test Kit. The electrode geometry is 1 square resulting in a reading expressed in ohms/square. Disconnect the test leads and electrodes from the meter. Mount the meter securely onto the adapter sled. Firmly press the sled s parallel electrodes onto the surface of the material to be tested, at the position specified by the procedure selected. Press and hold the red test button for at least 15-20 seconds. The LCD expresses surface resistivity in ohms/square and an illuminated LED indicates the reading s exponential value. Page 9 of 9