ExactTemp Service Manual

Similar documents
Thermostatic Valve Replacement Cartridge and Rebuild Kit

Installation Instructions S

Installation Instructions

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

MP8000 Series Pneumatic Valve Actuators

Installation Instructions

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

AMX300 DirectConnect Mixing Valve Kits

Rebuild Instructions for and Transmission

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

S&G Model 2937 Group 1 Combination Lock

INSTALLATION INSTRUCTIONS BL-8704

GPS AutoSteer System Installation Manual

INSTALLATION INSTRUCTIONS MK-8704

Stainless Steel Single and Dual Circulation Kits

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

FLUSHOMETER - TANK SYSTEM

2006 HEADSHOK Service Video #1

Installation Instructions / Warranty

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Rollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)

Coolflo Safe Touch Shower Mixing Valve ST20015CP

INSTALL INSTRUCTIONS: Blend Door Repair Kit

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Powers Controls TH 192 HC Heating/Cooling Room Thermostat


CARING FOR YOUR NEW BATH FITTER UNIT

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Cable Drum Installation

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

PARTS NEEDED FOR CONVERTING FROM LP TO NG

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use R0514

BODY-12, Door Handle - Removal, Installation, and Adjustment

Installation Instructions / Warranty

GENUINE PARTS INSTALLATION INSTRUCTIONS

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Operation and Service Guide: Showers

TS93 EMR T/PT/TDE. Surface applied door closer

STABITHERM INSTALLATION & SERVICE BOOKLET

HT-0095 Mini PV Receptacles AWG Crimping Hand Tool. Tool P/N HT-0095

SIG 556 Match Sear/Hammer Installation

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

M V Intake Manifold INSTALLATION INSTRUCTIONS

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

Step 1. Item 6. Item 1

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Powers Controls TH 192 S Single Temperature Room Thermostat

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Flat Bottom Long Ram Hydraulic Jack

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Tri-Homo Style Operation and Maintenance Instructions

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

REPLACEMENT INSTRUCTIONS FOR AWNING

Joplin Rebuild Instructions

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

INSTALLATION INSTRUCTIONS FOR VW MK5

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

MGA Alternator Conversion

SunMaxx Solar Filling Station Operating Instructions

BOWIE PUMPS OPERATION - MAINTENANCE

Triac Printed Circuit Board Replacement

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

MGB Chrome Bumper Conversion

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Series Hose Reels

MICROMETER ADJUSTABLE CLICK TYPE TORQUE WRENCH REPAIR, MAINTENANCE AND TROUBLESHOOTING MANUAL

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Balance Shoe and Balance Replacement

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

Cleaning & Sanitisation

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

MAC FAUCETS. Owner s Manual. Models: FA444

Interchangeable Cores

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

CAM-03, Camshaft Assembly Oil Seal Replacement

This instruction is valid for all ACD pump models shown on page 2

Fuel Injection Pump, Rotary ( )

T-4000 Series Room Thermostat Adjusting Instructions*

LPM-06 CONVERSION KIT

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Your safety and the safety of others are very important.

Transcription:

3371 ExactTemp Service Manual # 153768

TABLE OF CONTENTS I. Legal/Disclaimer/Safety Warnings pg II. Valve Specifications pg3 III. Exploded Valve Diagram/Cartridge Diagram pg4 IV. Trouble Shooting pg5 V. Cartridge Calibration pg6-8 VI. VII. Cartridge Servicing 1. Removal of the cartridge pg9-10. Installation of the cartridge pg11-1 Stops & Checks Servicing 1. Removal of the stops and checks pg13. Installation of the stops and checks pg13 VIII. Maintenance Record/Notes pg14 5/8 Socket 1-1/4 Socket Small Flat Head Screwdriver Phillips Head Screwdriver Channel Locks Thermometer Needle Nose Pliers Safety Glasses HELPFUL TOOLS page 1

LEGAL/DISCLAIMER/SAFETY CAUTION TIPS FOR REMOVAL OF OLD FAUCET: Always turn water supply OFF before removing existing faucet or disassembling the valve. Open faucet handle to relieve water pressure and ensure that complete water shut-off has been accomplished. FLUSHING Flush supply lines prior to installation is strongly recommended to prevent malfunction of thermostatic cartridge. WARNING: Risk of scalding Varying the calibration of this thermostatic valve to increase water temperature increases the risk of injury from scalding. The installer is responsible for installing the valve and any recalibration of the water temperature in accordance with the instructions. CAUTION: Danger of scald injury. Valve can be recalibrated to provide higher temperature water. This valve has been preset at the factory to provide a range of water temperatures. Any change in settings or water inlet conditions from those used during calibration at the factory may raise the outlet temperature and may cause scalding. The responsibility for the proper installation and any recalibration of this valve lies with the installer. page

VALVE SPECIFICATIONS Installation of the cartridge continued: 4. Using a 1-1/4 socket, install the cartridge retaining nut in the valve. 7. Without rotating the cartridge stem, align the temperature limit stop and the stem. 1 DESCRIPTION Brass construction 3/4" IPS connections Thermostatic valve design with integral checkstops OPERATION Temperature lever operates through a 340 degree arc with maximum cold at full clockwise rotation and maximum hot at full counterclockwise rotation Safety stop preset temperature at 105 degrees F ( 41degrees C) Safety stop override allows maximum temperature at 10 degrees F (49 degrees C) Factory established temperature range from 70 degrees F (1 degrees C) to 10 degrees F (49 degrees C) Must be used with at least one 3600 valve. CARTRIDGE 130156 thermostatic cartridge design with non metallic/nonferrous materials STANDARDS Third party certified to ASME A11.18.1/CSA B15.1, ASSE 1016 and all applicable requirements referenced therein including CARTRIDGE SERVICING 5. Using a wrench, install the handle adapter nut onto the valve. 8. While pushing in the stem, install the screw by turning clockwise until the screw bottoms out. 6. Install spring. 1 9. If integrated stops were used, release them by turning stop stem counterclockwise until they stop. page 3 page 1

EXPLODED VALVE DIAGRAM 1 3 4 5 6 7 8 9 1. Check Valve 6. Handle Adapter Nut. Stop Body 7. Spring 3. Stop Stem 8. Stem 4. Temperature Limit Stop 9. Screw 5. Cartridge Nut For service kit numbers refer to moen.com CARTRIDGE DIAGRAM 1 3 5 4 1. Bottom O-Ring 5. Pre-Set Temperature Alignment. Middle O-Ring Markings (105 ) 3. Top O-Ring 4. Screens page 4

TROUBLE SHOOTING Problem Description Cause Fix No flow or reduced flow Reduced flow or no flow from device Stop stems are closed Turn stop stems counterclockwise No flow or reduced flow Reduced flow or no flow from device Blocked screens on cartridge Remove cartridge and rinse. See Cartridge Servicing (pg 9). Outlet water temperature too high Water is hotter than 105 F at safety stop or 10 F in full hot Cartridge is out of calibration Remove cartridge and rinse. See Cartridge Calibration (pg 7). Outlet water temperature too high Water is hotter than 105 F at safety stop or 10 F in full hot Missing or damaged bottom o-ring Replace cartridge. See Cartridge Servicing (pg 9). Leak from around the cartridge Continuous leak from behind trim Cartridge has missing or damaged top o-ring. Replace cartridge. See Cartridge Servicing (pg 9). Leak from around the cartridge Continuous leak from behind trim Missing or loose cartridge nut Replace or tighten cartridge nut. See Cartridge Servicing (pg 9). All hot or all cold water Temperature adjustment does not provide mixed temperature Inlets are reversed Reinstall with hot water line to hot side of the valve and cold water line to cold side of the valve. No temperature stop detected Handle rotates greater than 00 and does not engage a stop Temperature limit stop is not properly seated in the valve Reassemble temperature limit stop. See Cartridge Servicing (pg 9). page 5

CARTRIDGE CALIBRATION Rotate the temperature control counterclockwise from the coolest setting (80 F) at the 7:00 position to the safety stop setting (105 F) at the 1:00 position. Push in the end of the stem to activate the safety stop override, then rotate the stem counterclockwise from (105 F) at the 1:00 position to the maximum temperature (10 F) at the 9:00 position. (fig.1) Use a thermometer to test the temperature of the water. If it is 10 F or less, turn the water off and attach your trim. No calibration is necessary. 1 Temperature Valve 1 Turn 7 1 Push, Hold, and Turn 9 1 3 fig.1 If the temperature is higher than 10 F, the valve must be calibrated to a lower temperature. To lower the maximum temperature, proceed to step on page 7. page 6

1 CARTRIDGE CALIBRATION cont. Rotate the temperature stem from the hottest position (9:00) clockwise to the safety stop position position (1:00). This is 1/4 of a turn and the stem will pop out when the proper position is reached. Temperature Valve 1 9 1 Continue rotating the stem clockwise from the (1:00) position to the (:00) position. (fig.) 1 3 fig. 3 Disengage Splines While holding the stem to prevent rotation, remove the screw turning counterclockwise. Pull the stem from the valve without rotating. (fig.3) fig.3 page 7

1 CARTRIDGE CALIBRATION cont. Rotate the stem from the (:00) position counterclockwise to the (1:00) position.(fig.4) C4 1 fig.4 Replace the stem in the new position and secure with screw. (fig.5) 5 fig.5 Test the temperature of the water. If it is still over 10 F, repeat steps 3 and 4 to lower the maximum temperature. page 8

1 CARTRIDGE SERVICING Removal of cartridge: 1. If water supply shut off valves are not accessible or are not present, actuate the stops by rotating the stop stem clockwise. Do not over tighten stop stem as this could damage the check valve. (fig.1). While holding the stem to prevent rotation, remove the screw turning counterclockwise. (fig.) 3. Remove spring. (fig.3) 4. Using a wrench, remove the handle adapter nut by turning counterclockwise. (fig.4) fig.1 fig. fig.3 fig.4 page 9

CARTRIDGE SERVICING Removal of cartridge continued: 5. Using a 1-1/4 socket, remove the cartridge retaining nut by turning counterclockwise. 1 6. Remove temperature limit stop. 7. Remove cartridge by using a wrench to pull out the cartridge. page 10

CARTRIDGE SERVICING Installation of the cartridge: 1. Verify that the cartridge is properly set by aligning the drilled hole in the cartridge stem to the indent on the cartridge body.. Assemble the temperature limit stop to the cartridge ensuring that the key on the temperature limit stop is aligned to the slot in the cartrige. 3. By pushing on the front of the temperature limit stop, insert cartridge into the valve body until the temperature limit stop key is fully seated into the valve. page 11

VALVE SPECIFICATIONS Installation of the cartridge continued: 4. Using a 1-1/4 socket, install the cartridge retaining nut in the valve. 7. Without rotating the cartridge stem, align the temperature limit stop and the stem. 1 DESCRIPTION Brass construction 3/4" IPS connections Thermostatic valve design with integral checkstops OPERATION Temperature lever operates through a 340 degree arc with maximum cold at full clockwise rotation and maximum hot at full counterclockwise rotation Safety stop preset temperature at 105 degrees F ( 41degrees C) Safety stop override allows maximum temperature at 10 degrees F (49 degrees C) Factory established temperature range from 70 degrees F (1 degrees C) to 10 degrees F (49 degrees C) Must be used with at least one 3600 valve. CARTRIDGE 130156 thermostatic cartridge design with non metallic/nonferrous materials STANDARDS Third party certified to ASME A11.18.1/CSA B15.1, ASSE 1016 and all applicable requirements referenced therein including CARTRIDGE SERVICING 5. Using a wrench, install the handle adapter nut onto the valve. 8. While pushing in the stem, install the screw by turning clockwise until the screw bottoms out. 6. Install spring. 1 9. If integrated stops were used, release them by turning stop stem counterclockwise until they stop. page 3 page 1

REPLACING STOPS & CHECKS NOTE: If servicing stops, water shut off valves must be shut off prior to removal. Removal of the stops and checks: 1. Using a 5/8 socket, remove the stop by turning counterclockwise.. Using pliers, remove check valve by pulling on the check valve s ribs. Installation of the stops and checks: 1. Push the check valve into the opening.. Using a 5/8 socket, install the stop body by turning clockwise. page 13

MAINTENANCE RECORD THERMOSTATIC MIXING VALVE Valve ref.: Installation Date: Location: Maintenance frequency: Commissioning/maintenance check: DATE TECHNICIAN SERVICE DETAILS NOTES page 14

# 153768-5/10 010 Moen Incorporated 5300 Al Moen Drive North Olmsted, OH 44070-80 U.S.A. In Canada Moen Inc. 816 Bristol Circle Oakville, Ontario L6H5S7