Serial ATA Flash Drive

Similar documents
Serial ATA Flash Drive

Serial ATA Flash Drive

Serial ATA Flash Drive

Serial ATA Flash Drive

SATA-Disk Module 4. RoHS Compliant. SDM4 22P/180D Product Specifications. December 1 st, Version 1.0. Apacer Technology Inc.

Mini PCIe SSD - mpdm. RoHS Compliant. Product Specifications. August 15 th, Version 1.0

Serial ATA Flash Drive

Serial ATA Flash Drive

Serial ATA Flash Drive

ATA Flash Drive 187. RoHS Compliant. High-capacity Product Specifications. February 6 th, Version 1.0. Apacer Technology Inc.

USB Flash Drive. RoHS Compliant. AH322 Specifications. July 2 nd, Version 1.2. Apacer Technology Inc.

SATA SSD Series. InnoDisk. Customer. Approver. Approver. Customer: Customer. InnoDisk. Part Number: InnoDisk. Model Name: Date:

Serial ATA Flash Drive

Serial ATA Flash Drive

RoHS Compliant SATA High Capacity Flash Drive Series Datasheet for SAFD 25NH-M

SATA-Disk Module 5. RoHS Recast Compliant. SDM5 7P/180D Low Profile Product Specifications. June 25 th, Version 1.3. Apacer Technology Inc.

USB Flash Drive. RoHS Compliant. AH321 Specifications. June 4 th, Version 1.4. Apacer Technology Inc.

SATA-Disk Module 5. RoHS Recast Compliant. SDM5 7P/180D Slim2 Product Specifications. July 17 th, Version 1.2. Apacer Technology Inc.

SATA-Disk Module 5. RoHS Recast Compliant. SDM5 7P/90D Low Profile Product Specifications. March 17, Version 1.4. Apacer Technology Inc.

Value Added ATA Disk Module Ⅲ

CompactFlash Series 6

Value Added CompactFlash Series 5

Serial ATA RAID Flash Drive

Industrial Micro SD 3.0

Features. SSD370S SATA III 6Gb/s SSD. Advanced Global Wear-Leveling and Block management for reliability

Industrial Micro SD 3.0

PSD330. Features. Dimensions. Specifications. - Support S.M.A.R.T (Self-defined) - Support Security Command

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

AES 256-BIT HARDWARE ENCRYPTED USB FLASH DRIVES & SSD

Barracuda Serial ATA

PRODUCT MANUAL. Barracuda Serial ATA ST AS ST AS ST AS ST AS ST AS ST AS ST AS ST AS

SATA II 3Gb/s SSD. SSD630 Benefits. Enhanced Performance. Applications

HG2 Series Product Brief

Features. Dimensions

Features. Dimensions

Features. Dimensions

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

Intel X25-E SATA Solid State Drive

Industrial Semi Metal USB

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Industrial Flash Storage Module

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

W25Q80, W25Q16, W25Q32 8M-BIT, 16M-BIT AND 32M-BIT SERIAL FLASH MEMORY WITH DUAL AND QUAD SPI

Installation Guide. Zip ATAPI Drive. Quick Start Information Installation Notes Technical Notes Troubleshooting Drive Specifications

Product Specification

Vol.2. Industrial SD Memory. Program/Erase Endurance. Extended Temperature. Power Failure Robustness

Intel Solid-State Drive 320 Series

Nasir Memon Polytechnic Institute of NYU

Description. Features. Placement. Transcend Information Inc. Side Millimeters Inches. 2.5 Solid State Disk

Future Technology Devices International Ltd

EUDAR Technology Inc. Rev USB 2.0 Flash Drive. with Card Reader. Datasheet. Rev. 1.0 December 2008 EUDAR 1

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

NAND Flash FAQ. Eureka Technology. apn5_87. NAND Flash FAQ

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

IDE 4000 Flash Disk. 1.8" and 2.5" Product Specification and User Manual. January PS Rev. 2.1

Panther series CompactFlash CARD

Technologies Supporting Evolution of SSDs

Disturbance Recoder SPCR 8C27. Product Guide

Saber 1000 Series. Enterprise SSD. 2.5 Solid-State Drive. SB1CSK31MT5XX-xxxx. SSD Datasheet

Intel Solid-State Drive 330 Series

Intel Solid-State Drive 335 Series

DMX2PWM 9 Channel Dimmer Setup Manual

760 Veterans Circle, Warminster, PA Technical Proposal. Submitted by: ACT/Technico 760 Veterans Circle Warminster, PA

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

FFD 2.5" IDE Plus Flash Disk

Industrial Flash Storage Trends in Software and Security

SSD Server Hard Drives for IBM

Choosing the Right NAND Flash Memory Technology

1 Gbit, 2 Gbit, 4 Gbit, 3 V SLC NAND Flash For Embedded

HP 80 GB, 128 GB, and 160 GB Solid State Drives for HP Business Desktop PCs Overview. HP 128 GB Solid State Drive (SSD)

Telephone- and leased line modem for industrial applications TD-36

Overview 2.5 & 1.8 Industrial SSD SATADOM mini PCIeDOM SATA Slim CF Card & EDC CF-SATA & CFast. Embedded Flash Storage

Future Technology Devices International Ltd. USB NMC-2.5m. USB to USB Null Modem Cable. Datasheet

VASCO Data Security International, Inc. DIGIPASS GO-7. FIPS Non-Proprietary Cryptographic Module Security Policy

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

Intel Solid State Drive Toolbox

Barracuda PATA

HP 128 GB Solid State Drive (SSD) *Not available in all regions.

Intel Solid State Drive Toolbox

0832 Dot Matrix Green Display Information Board User s Guide

Industrial Bar Code Scanners

HT1632C 32 8 &24 16 LED Driver

1. SAFETY INFORMATION

Wireless Temperature

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size ( inches [ mm])

User Manual. EtherUSB

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Industrial Grade Embedded Flash Storage Devices

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

NC-12 Modbus Application

Hardware Specifications of V2AF Series Hybrid Card Reader

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

COS 318: Operating Systems. Storage Devices. Kai Li Computer Science Department Princeton University. (

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Barracuda Serial ATA

Programming NAND devices

Digital input modules

Transcription:

RoHS Compliant Serial T Flash Drive Specifications for SFD 18P March 23 rd, 2012 Version 1.1 pacer Technology Inc. 4 th Fl., 75 Hsin Tai Wu Rd., Sec.1, Hsichih, New Taipei City, Taiwan 221 Tel: +886-2-2698-2888 Fax: +886-2-2698-2889 www.apacer.com

Features: Standard Serial T 2.6 Serial T 2.6 ST II, 3.0 Gbps T-compatible command set Capacities 8, 16, 32, 64, 128 G Performance* urst read/write: 300 M/sec Sustained read: up to 260 M/sec Sustained write: up to 215 M/sec Intelligent endurance design uilt-in hardware ECC, enabling up to 16/24 bit correction per 1024 bytes Static wear-leveling scheme together with dynamical block allocation to significantly increase the lifetime of a flash device and optimize the disk performance Flash bad-block management S.M..R.T. Power Failure Management T Secure Erase TRIM NND Flash Type: SLC Zero power data retention No battery required for data storage Temperature ranges Operation: Standard: 0 C to 70 C (32 ~ 158 F) Extended: -40 C to 85 C (-40 ~ 185 F) Storage: -40 C to 100 C (-40 ~ 212 F) Supply voltage 3.3V & 5V Power consumption (typical)* ctive mode: 978 m (Max) Idle mode: 303 m Form factor 1.8 inch (78.5 x 54 x 5, unit: mm) Connector 7-pin ST male connector 9-pin ST power connector Shock & Vibration Shock: 50g (approx.) Vibration: 15g (approx.) RoHS compliant *Varies from capacities. The values addressed for performance and power consumption are typical and may vary depending on settings and platforms. 1

Table of Contents 1. Product Description... 3 1.1 Introduction... 3 1.2 Functional lock Diagram... 3 1.3 T Mode Support... 4 1.4 Capacity Specification... 4 1.5 Performance... 4 1.6 Pin ssignments... 5 2. Software Interface... 7 2.1 Command Set... 7 2.2 S.M..R.T.... 9 3. Flash Management... 10 3.1 Error Correction/Detection... 10 3.2 ad lock Management... 10 3.3 Wear Leveling... 10 3.4 Power Failure Management... 10 3.5 T Secure Erase... 10 3.6 TRIM... 11 4. Environmental Specifications... 12 4.1 Environments... 12 4.2 Mean Time etween Failures (MTF)... 12 4.3 Certification and Compliance... 12 5. Electrical Characteristics... 13 5.1 Operating Voltage... 13 5.2 Power Consumption... 13 5.3 Electrostatic Discharge... 13 5.4 Electrical Fast Transient/urst... 14 6. Physical Characteristics... 15 7. Product Ordering Information... 17 7.1 Product Code Designations... 17 7.2 Valid Combinations... 18 2

1. Product Description 1.1 Introduction pacer s Serial T Flash Drive (SFD) is a solid-state disk (SSD) drive that contains a controller, embedded firmware, and flash media along with a male connector. Using NND flash memory devices, the SFD drive interfaces with the host allowing data to be seamlessly transferred between the host and the flash devices. SFD 18P drive is designed with a single-chip controller, offering capacities of up to 128 gigabytes and providing full support for the ST II high-speed interface standard. It can operate at sustained access rates of up to higher than 200 megabytes per second, which is much more ideal for storage than traditional STbased hard disk drive currently available on the market. In addition to buffer management through dynamical allocation, SFD 18P adopts the pacer-specific static wear-leveling scheme to allow uniform use of all storage blocks, ensuring that the lifetime of a flash media can be significantly increased and the disk performance is optimized as well. SFD 18P provides the S.M..R.T. feature that follows the ST Rev. 2.6, T/TPI-7 specifications and uses the standard SMRT command 0h to read data from the drive. This feature protects the user from unscheduled downtime by monitoring and storing critical drive performance. 1.2 Functional lock Diagram SFD 18P drive includes a single-chip ST II Controller and the flash media, as well as the ST standard interface. The controller integrates the flash management unit with the controller itself to support multi-channel, multi-bank flash arrays. Figure 1-1 shows the functional block diagram. Figure 1-1 pacer SFD 18P block diagram 3

1.3 T Mode Support SFD 18P provides T mode support as follows: Up to PIO mode-4 Up to Multiword DM mode-2 Up to UDM mode-5 1.4 Capacity Specification Capacity specification of SFD 18P product family is available as shown in Table 1-1. It lists the specific capacity, the default numbers of logical cylinders and heads, and the number of logical sectors per track for each product line. Table 1-1 Capacity specification Capacity Total ytes* Cylinders Heads Sectors Max L** 8 G 7,012,196,352 13,587 16 63 13,695,696 16 G 16,013,942,784 16383 16 63 31,277,232 32 G 32,017,047,552 16,383 16 63 62,533,296 64 G 64,023,7,088 16383 16 63 1,045,44 128 G 128,035,676,10 16383 16 63 0,069,60 *Display of total bytes varies from file systems. **Cylinders, heads or sectors are not applicable for these capacities. Only L addressing applies. 1.5 Performance Performance of SFD 18P is shown in Table 1-2. Table 1-2 Performance specification Capacity Performance 8 G 16 G 32 G 64 G 128 G Sustained Read (M/s) 5 260 260 260 245 Sustained Write (M/s) 100 205 190 215 165 Note: Performances vary from flash configurations. 4

1.6 Pin ssignments Table 1-3 describes SFD 18P signal segment, and Table1-4, its power segment. Figure 1-2 Micro-ST Connectors Power Segment Pin P1 Signal Segment Pin S1 Table 1-3 Signal segment Table 1-4 Power segment Name Type Description Pin Type Signal/Description S1 GND P1 V33 3.3 V Power S2 RxP + Differential Receive Signal P2 V33 3.3 V Power S3 RxN - Differential Receive Signal P3 GND S4 GND P4 GND S5 TxN - Differential Transmit Signal P5 V5 5 V Power S6 TxP + Differential Transmit Signal P6 V5 5 V Power S7 GND P7 GND Ground/Reserved P8 Optional NC P9 Optional NC 5

Figure 1-3 ST Cable/Connector Connection Diagram The connector on the left represents the Host with TX/RX differential pairs connected to a cable. The connector on the right shows the Device with TX/RX differential pairs also connected to the cable. Notice also the ground path connecting the shielding of the cable to the Cable Receptacle. 6

2. Software Interface 2.1 Command Set Table 2-1 summarizes the T commands supported by SFD 18P. Table 2-1 Command set (1 of 2) Command Code FR 1 SC 2 SN 3 CY 4 DH 5 L 6 Check-Power-Mode E5H - - - - D 8 - Execute-Drive-Diagnostic 90H - - - - D - Flush-Cache E7H - - - - D - Identify-Drive ECH - - - - D - Idle E3H - Y - - D - Idle-Immediate E1H - - - - D - Initialize-Drive-Parameters 91H - Y - - Y - Read-DM C8H or C9H - Y Y Y Y Y Read-Multiple C4H - Y Y Y Y Y Read-Sector(s) 20H or 21H - Y Y Y Y Y Read-Verify-Sector(s) 40H or 41H - Y Y Y Y Y Recalibrate 10H - - - - D - Security-Disable-Password F6H - - - - D - Security-Erase-Prepare F3H - - - - D - Security-Erase-Unit F4H - - - - D - Security-Freeze-Lock F5H - - - - D - Security-Set-Password F1H - - - - D - Security-Unlock F2H - - - - D - Seek 7XH - - Y Y Set-Features EFH Y 7 - - - D - 7

Table 2-1 Command set (2 of 2) Command Code FR 1 SC 2 SN 3 CY 4 DH 5 L 6 Set-Multiple-Mode C6H - Y - - D - Sleep E6H - - - - D - SMRT 0H Y Y Y Y D Standby E2H - - - - D - Standby-lmmediate E0H - - - - D - Write-DM CH - Y Y Y Y Y Write-Multiple C5H - Y Y Y Y Y Write-Sector(s) 30H - Y Y Y Y Y 1. FR - Features register 2. SC - Sector Count register 3. SN - Sector Number register 4. CY - Cylinder registers 5. DH - Drive/Head register 6. L - Logical lock ddress mode supported (see command descriptions for use) 7. Y - The register contains a valid parameter for this command. 8. For the Drive/Head register: Y means both the SFD and Head parameters are used D means only the SFD parameter is valid and not the Head parameter 8

2.2 S.M..R.T. S.M..R.T. is an acronym for Self-Monitoring, nalysis and Reporting Technology, an open standard allowing disk drives to automatically monitor their own health and report potential problems. It protects the user from unscheduled downtime by monitoring and storing critical drive performance and calibration parameters. Ideally, this should allow taking proactive actions to prevent impending drive failure. pacer devices use the standard SMRT command 0h to read data out from the drive to activate our SMRT feature that complies with the T/TPI-7 specifications. ased on the SFF-8035i Rev. 2.0 specifications, pacer SMRT defines vendor-specified SMRT ttribute IDs (0 ~ 5, and 0C). They represent Initial bad block count, ad block count, Spare block count, Maximum erase count, verage erase count and Power cycle. When the pacer SMRT Utility running on the host, it analyzes and reports the disk status to the host before the device reaches in critical condition. 9

3. Flash Management 3.1 Error Correction/Detection SFD 18P implements hardware ECC scheme based on the CH algorithm which can detect and correct up to 16 bits or 24 bits error in 1024 bytes. 3.2 ad lock Management lthough bad blocks on the flash media are already identified by the flash manufacturer, they can also be accumulated over time during operation. SFD 18P s controller maintains a table that lists those normal blocks with disk data, the free blocks for wear leveling, and bad blocks with errors. When a normal block is detected broken, it is replaced with a free block and listed as a bad block. When a free block is detected broken, it is then removed from the free block list and marked as a bad block. During device operation, this ensures that newly accumulated bad blocks are transparent to the host. The device will stop file write service once there are only two free blocks left such that the read function is still available for copying the files from the disk into another. 3.3 Wear Leveling The NND flash devices are limited by a certain number of write cycles. When using a FT-based file system, frequent FT table updates are required. If some area on the flash wears out faster than others, it would significantly reduce the lifetime of the whole SSD, even if the erase counts of others are far from the write cycle limit. Thus, if the write cycles can be distributed evenly across the media, the lifetime of the media can be prolonged significantly. This scheme is called wear leveling. pacer s wear-leveling scheme is achieved both via buffer management and pacer-specific static wear leveling. They both ensure that the lifetime of the flash media can be increased, and the disk access performance is optimized as well. 3.4 Power Failure Management The Low Power Detection on the controller initiates crucial data saving before the power supplied to the device is too low. This feature prevents the device from crash and ensures data integrity during an unexpected power-off. 3.5 T Secure Erase ccomplished by the Secure Erase (SE) command, which added to the open NSI standards that control disk drives, T Secure Erase is built into the disk drive itself and thus far less susceptible to malicious software attacks than external software utilities. It is a positive easy-to-use data destroy command, amounting to electronic data shredding. Executing the command causes a drive to internally completely erase all possible user data. This command is carried out within disk drives, so no additional software is required. Once executed, neither data nor the erase counter on the device would be recoverable, which blurs the accuracy of device lifespan. The process to erase will not be stopped until finished while encountering power failure, and will be continued when power is back on. 10

3.6 TRIM Made of millions of NND flash cells, SSD can be written into groups called pages in 4K size generally, but can only be erased in larger groups called blocks of 128 pages or 512K. These stipulations are partially the source of many performance issues. Until an address gets used again, the SSD has to keep track of every last bit of data that s written on it. The T-TRIM instruction tilts the balance in favor of the SSD. TRIM addresses a major part of the performance degradation issue over time that plagues all SSDs. TRIM enabled drive running an OS with TRIM support will stay closer to its peak performance over time. 11

4. Environmental Specifications 4.1 Environments SFD 18P environmental specifications follow the US Military Standard MIL-STD-810F, as shown in Table 4-1. Table 4-1 SFD 18P environmental specifications Environment Temperature Humidity Vibration Shock - Operating ltitude *Extended Temperature Specification 0 C to 70 C (Operating Standard); -40 C to 85 C (Operating ET*) -40 C to 100 C (Non-operating) 5% to 95% RH (Non-condensing) Sine wave: 5~55~5 Hz (X, Y, Z) Random: 10-2000 Hz, 16.3 G (X, Y, Z) cceleration: 1,500 G, 0.5 ms Peak acceleration: 50 G, 11 ms 80,000 ft 4.2 Mean Time etween Failures (MTF) Mean Time etween Failures (MTF) is predicted based on reliability data for the individual components in SFD drive. lthough many component MTFs are given in databases and often these values are not really accurate, the prediction result for SFD 18P is more than 2,000,000 hours. Notes about the MTF: The MTF is predicated and calculated based on Telcordia Technologies Special Report, SR-332, Issue 2 method. 4.3 Certification and Compliance SFD 18P drive complies with the following standards: CE EN55022/55024 FCC 47CFR Part15 Class RoHS MIL-STD-810F ST II (ST Rev. 2.6) Up to T/TPI-7 ( including S.M..R.T.) 12

5. Electrical Characteristics 5.1 Operating Voltage Table 5-1 lists the supply voltage for SFD 18P. Table 5-1 SFD 18P operating voltage Parameter Supply voltage Conditions 3.3V ±5% (3.135-3.465V) / 5V ±5% (4.75-5.V) 5.2 Power Consumption Table 5-2 lists SFD 18P power consumption. Capacity Mode ctive Mode (m) Idle Mode (m) 5.3 Electrostatic Discharge Table 5-2 SFD 18P power consumption (Typical) 8 G 16 G 32 G 64 G 128 G 610 920 978 800 600 290 300 303 300 0 Note: power consumptions may vary depending on different flash configurations or platforms. Table 5-3 Electrostatic discharge Item mount of Discharge Voltage Required Criteria Complied To Criteria (,,C) ir Discharge 10 10 +8kV -8kV Contact Discharge +4kV -4kV Indirect Discharge (HCP) +4kV -4kV Indirect Discharge (VCP Front) +4kV -4kV 13

Indirect Discharge (VCP Left) +4kV -4kV Indirect Discharge (VCP ack) +4kV -4kV Indirect Discharge (VCP Right) +4kV -4kV 5.4 Electrical Fast Transient/urst Table 5-4 Electrical Fast Transient/urst Inject Line Polarity Voltage kv Inject Time (Second) Inject Method Required Criteria Complied to Criteria L-N-PE ± 1kV 60 Direct Notes about 5.3 Electrostatic Discharge & 5.4 Electrical Fast Transient/urst The tests performed are from lowest level up to the highest level as required by standard, but only highest level is shown on the report. Meet criteria : Operate as intended during and after the test Meet criteria : Operate as intended after the test Meet criteria C: Loss/Error of function dditional Information: EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. The Contact discharges were applied at least total 200 discharges at a minimum of four test points. 14

6. Physical Characteristics Pin P1 Pin S1 Unit: mm Tolerance: ± 0.2 15

Pin S1 Unit: mm Tolerance: ± 0.2 16

7. Product Ordering Information 7.1 Product Code Designations P S 18P 6 x x x x C X X X Voltage lank: 5V L: 3.3V Temperature Range lank: Standard W: Extended Temperature Flash Type T: Toshiba C: Micron Version Control Capacities: 008G: 08 G 016G: 16 G 032G: 32 G 064G: 64 G 128G: 128 G pacer rand Solution version 1.8 inch Form Factor Serial T Flash Drive pacer Product Code 17

7.2 Valid Combinations SFD18P (voltage: 5V) Capacity Standard Extended Temperature 8 G PS18P6008G-CT PS18P6008G-CTW 16 G PS18P6016G-CT PS18P6016G-CTW 32 G PS18P6032G-CT PS18P6032G-CTW 64 G PS18P6064G-CC PS18P6064G-CCW 128 G PS18P6128G-CC PS18P6128G-CCW SFD18P (voltage: 3.3V) Capacity Standard Extended Temperature 8 G PS18P6008G-CTL PS18P6008G-CTWL 16 G PS18P6016G-CTL PS18P6016G-CTWL 32 G PS18P6032G-CTL PS18P6032G-CTWL 64 G PS18P6064G-CCL PS18P6064G-CCWL 128 G PS18P6128G-CCL PS18P6128G-CCWL Note: Valid combinations are those products in mass production or will be in mass production. Consult your pacer sales representative to confirm availability of valid combinations and to determine availability of new combinations. 18

Revision History Revision Description Date 0.1 Preliminary release 09/02/2011 0.2 dded 64G & 128G capacities 10/17/2011 Updated Product Ordering Information 0.3 Updated Product Ordering Information 11/17/2011 1.0 Official release 11/30/2011 1.1 Revised S.M..R.T information 03/23/2012 19

Global Presence Taiwan (Headquarters) U.S.. Japan Europe China India pacer Technology Inc. 4 th Fl., 75 Hsin Tai Wu Rd., Sec.1 Hsichih, New Taipei City Taiwan 221 R.O.C. Tel: +886-2-2698-2888 Fax: +886-2-2698-2889 amtsales@apacer.com pacer Memory merica, Inc. 386 Fairview Way, Suite102, Milpitas, C 95035 Tel: 1-408-518-8699 Fax: 1-408-935-9611 sa@apacerus.com pacer Technology Corp. 5F, Matsura ldg., Shiba, Minato-Ku Tokyo, 105-0014, Japan Tel: 81-3-5419-2668 Fax: 81-3-5419-0018 jpservices@apacer.com pacer Technology.V. ziëlaan 22, 5232 's-hertogenbosch, The Netherlands Tel: 31-73-645-9620 Fax: 31-73-645-9629 sales@apacer.nl pacer Electronic (Shanghai) Co., Ltd 1301, No.1,Xiaomuqiao Road, Shanghai, 200032, China Tel: 86-21-5529-0222 Fax: 86-21-5206-6939 sales@apacer.com.cn pacer Technologies Pvt Ltd, #1064, 1st Floor, 7th Main, 3rd lock Koramangala, angalore 560 034 Tel: +91 80 4152 9061/62/63 Fax: +91 80 4170 0215 sales_india@apacer.com 20