Siemens Has Your Answers

Similar documents
Mammography Applications for MAMMOMAT 1000/3000 Nova

Mammomat Inspiration Mammomat Inspiration Prime

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT TECHNICAL MANUAL /11 LAT LAT SIN DEX. kv kv. mas. mas CTL

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Measuring Size and Distance in Digital Mammography

X-Mind. Instinct for perfection

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Digital panoramic X-ray for practical diagnostics

A Breakthrough in Breast Specimen Imaging

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM

X-ray Imaging Systems

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

The professional for your diagnostics.

Quality Control of Full Field Digital Mammography Units

KS-70. Catheterization Table GENERAL

Luminos Agile A RADical new way in fluoroscopy Answers for Life

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

IAEA-TECDOC-1447 Optimization of the radiological protection of patients: Image quality and dose in mammography (coordinated research in Europe)

Mammography. What is Mammography?

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

MEDICAL IMAGING. 90/30 Remote Controlled RF System

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Digital Dental X-ray. Midmark Animal Health Products

Data. microcat +SPECT

Digital Breast Tomosynthesis QC Requirements

Needle crystal detector technology in mammography further dose reduction and clinical image quality with

X-ray Imaging Systems

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Quality Control and Maintenance Programs

Performance testing for Precision 500D Classical R/F System

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Development of High-sensitivity and High-resolution Digital Mammography System AMULET

MS6000 Microform Scanner

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

BREAST CHARACTERISTICS AND DOSIMETRIC DATA IN X RAY MAMMOGRAPHY - A LARGE SAMPLE WORLDWIDE SURVEY

Purchasing a cardiac CT scanner: What the radiologist needs to know

DR Retrofit Kit 1417 WL Configuration Integrated PACS

Digital Mammography Update: Design and Characteristics of Current Systems

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

Global Business Unit Address. Siemens Medical Solutions USA, Inc N. Barrington Road Hoffman Estates, IL Telephone:

Annual MQSA Inspection Questions NMQAAC April 19, 2004

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Pipe Cutting and Beveling Clamshells

The wait is over CS D. 3D imaging is now available for everyone

View of ΣIGMA TM (Ref. 1)

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

The digital fluoroscopy all-rounder for your radiology department. AXIOM Iconos MD.

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

Page: 1 of 6 Page: 1 of 6

AXIOM Artis U The little big one for universal angiography and cardiology applications

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Mammography: Dosimetry ACMP Annual Meeting Virginia Beach Saturday, May 2, 2009 Lawrence N. Rothenberg, Ph.D. Department of Medical Physics Memorial

The Convenient and Compact CR System for Veterinary Practices

Dose Measurement in Mammography; What are we measuring? David E. Hintenlang, Ph.D. DABR University of Florida

Digital radiography conquers the veterinary world

Supports screening, diagnostic, and multimodality workflows

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

Evolve LED Area Light

EQUIPMENT REQUIREMENTS AND QUALITY CONTROL FOR MAMMOGRAPHY

Cardius. XPO Series. Cardius 3 XPO

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Infrared Thermography Not a Useful Breast Cancer Screening Tool

Phoroptor VRx Digital Refraction System

DENTAL Cone beam 3D X-RAY SYSTEM with

AngiX III FD Boost your confidence beyond the clinical. gehealthcare.com

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Reducing the risk of work-related musculoskeletal disorders in mammography screening

ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

I SEE THE FUTURE

user's manual _19

RVG Full range imaging for diagnostic confidence ROBUST DESIGN SUPERIOR ERGONOMICS NEW IMAGE PROCESSING TOOLS ENHANCED WORKFLOW

MATRIX borehole logging system

Transcription:

Siemens Has Your Answers MAMMOMAT 3000 Nova clinical solutions are multipurpose, reliable, and full of high-performance features. The system provides excellent return on investment and is scalable to suit all environments from the private clinic to the multi-department institution. Siemens also protects your investment MAMMOMAT 3000 Nova is upgradeable at any time. Please contact your local Siemens representative for more information on MAMMOMAT 3000 Nova and other top-quality systems for Women s Health. Siemens reserves the right to modify the design and specifications contained herein without prior notice. Siemens-Elema AB SE-171 95 Solna, Sweden Tel: +46-8-730-7473 E-mail: mammography.info@elema.siemens.se Internet: http://siemensmedical.com/mammo Art.nr. 65 79 994 Order No. A91003-M1270-B02-4A00 Printed in Sweden WS1101

s Because she deserves the very best MAMMOMAT 3000 Nova

2

Partners in Women s Health Care Whether we are captivated by international breast cancer statistics or touched by the personal experiences of our own patients, it is clear that breast care challenges are diverse and numerous. Your breast care systems must enable you to handle your patients' needs with confidence, speed and efficiency from screening and diagnosis through therapy. MAMMOMAT 3000 Nova, an anchor system in Siemens spectrum of breast care solutions, expands the MAMMOMAT legacy by offering screening, diagnostic work-up, and stereotactic biopsy capabilities in a single unit. MAMMOMAT 3000 Nova is a high performance, reliable mammography system. It is patient- and user-friendly, and yields the highest quality images. If your goal is to accurately diagnose breast disease in its earliest, most treatable stages, then you couldn't have a better partner than Siemens - - or a more versatile mammography system than MAMMOMAT 3000 Nova. 3

One system for all procedures from screening through interventional diagnostics MAMMOMAT 3000 Nova offers the most versatile technology for breast imaging and biopsy guidance. Its open design, integrated features, and work-horse reliability ensure the highest performance. Because it is a screening unit, diagnostic work-up system and stereotactic biopsy unit all in one, MAMMOMAT 3000 Nova maximizes system utilization potential, return on investment and space savings. Imagine the efficiency of using one system for: Screening Special Views Magnification Stereotactic biopsy, fine needle and core Needle localization Specimen radiography Stereotactic biopsy can be performed with the patient in a comfortable sitting or recumbent position. The system accommodates biopsy between +120 and 165, in steps of 15. Mammogram, mlo view Stereotactic biopsy, patient seated With the functions of a dedicated biopsy system and the versatility to handle all mammography procedures, MAMMOMAT 3000 Nova is an investment which pays for itself, over and over again. 4 Stereotactic biopsy, patient recumbent

Ergonomic design and handling patient-friendly and user-friendly Siemens engineers added new design elements, softer lines and a fresh look for MAMMOMAT 3000 Nova, while preserving the highly-appreciated features and options of our proven M3000. Superior Accessibility The slim tube-head design and narrow base allows easy, proper positioning of patients, including those in wheelchairs. Excellent ergonomic conditions are preserved for both operator and patient, even during biopsy procedures. between angle settings every angle from cc to the inverted 180 without readjusting the height. Pivoting Buckys The unique dual Bucky design enables quick and easy switching between 18x24 and 24x30 cm formats. When the object table is changed, the appropriate collimation automatically pre-selects. Additionally, either object table can be manually replaced with the stereotactic device or magnification table. Isocentricity Motorized isocentric movement offers precision and time-savings when positioning patients. Because the swivel arm moves isocentrically, the object table remains at the proper height between projections. Change Generous gantry free-space The 65-cm gantry opening (SID) allows easy patient positioning and accommodates popular biopsy devices. For example, the minimally-invasive vacuumassisted Mammotome core biopsy system can be mounted in the vertical position in the stereotactic device in line with the direction of compression for the shortest distance and greatest accuracy in reaching the lesion. 5

Advanced features in an advanced system Opcomp Optimized Compression No More, No Less Women used to complain about uncomfortable traditional mammography. Now there is Opcomp optimized compression. This exclusive Siemens feature, standard on MAMMOMAT 3000 Nova, senses breast thickness and compressibility. It compresses as long as the breast is soft and pliable, then stops precisely when image quality is maximized. Opcomp spares your patient unnecessary discomfort, and ensures consistent and reproducible compression technique. Opcomp is easy to operate - when the optimal value is reached, the green indicator light on the floor display is activated, and the system is ready for exposure. Opdose Optimized dose Mo/Mo, Mo/Rh, W/Rh Siemens invented the dual-track X-ray tube, with Molybdenum and Tungsten anode materials in 1994, and it has gained popularity with every installation. The Opdose system autoselects the best anode/filter combination (Mo/Mo, Mo/Rh, W/Rh), and the lowest dose, according to individual breast characteristics. This is particularly important for younger women whose breasts normally have higher density and often require higher dose. By selecting W/Rh in appropriate cases, Opdose can save up to 60% dose over a comparable Mo/Mo exposure. 6

Technical specifications MAMMOMAT 3000 Nova Generator High-voltage wave form: Exposure voltage: mas range: Exposure times: Multipulse 23kV to 35kV, adjustable in increments of 1kV Mo X-ray tube: 2mAs to 560 mas (mas-mode) up to 600mAs (AEC-mode) Mo/W X-ray tube: 2mAs to 710 mas (mas-mode) up to 752 mas (AEC-mode) From 10 ms to 4s From 10 ms to 7s for magnification technique Automatic exposure control Automatic exposure control (AEC): Detectors: Accuracy of optical density (2-6 cm): Density correction: Film-screen combinations: Microprocessor controlled, transparency compensation Semi conductor detector ± 0.15 OD from the mean optical density for predefined filmscreen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kv). ± 3 exposure points, adjustable in 1/8 step increments 2; User selectable on the generator control panel (H/D). X-ray tube assembly X-ray tube (Mo resp. Mo/W): Tube current (Mo resp. Mo/W): Molybdenum/Tungsten rotating anode tube with Beryllium window, P40 Mo/W four focus tube with nominal focal spot value 0.1/0.3 (star pattern), 0.15/0.3 (DIN/IEC 336/1993) Molybdenum max. large focal spot: 150 ma at 25 kv, max. small focal spot: 28 ma at 25 kv. Tungsten max. large focal spot. 188 ma at 25 kv, max. small focal spot 34 ma at 25 kv. Total heat storage capacity: 1 100 00 Joule (1 500 00 HU)(IEC 613/1989) Anode heat storage capacity: 120 000 Joule (162 000 HU)(IEC 613/1989) Anode speed: 8 800 r.p.m. Filter: Mo tube : 30µm Molybdenum, 25µm Rhodium Mo/W tube: 30µm Molybdenum, 25µm Rhodium, 50µm Rhodium X-ray stand Height adjustment: Motorized, 650 mm to 1350 mm floor to object table (in all angles) Swivel range: +135 / -180 Rotation of swivel arm: Motorized, isocentric Source to Image Distance (SID): 65 cm Film formats: 18cm x 24cm, 24cm x 30cm (15 mm thick Mammography cassettes according to DIN 6832/IEC 406). Automatic collimation to film format Grid: Reciprocating; Pb 4/27 (4:1 ratio, 27 lines/cm) Compression device: Opcomp, motorized compression initiated via footswitch or manual adjustment 7

Compression force: Maximum motorized force 200N Magnification technique: Factor of 1.5 and 1.8 Power supply: 110V, 208V, 230V, 240V, 277V, ± 10%, 1-phase; 208V, 230V, 277V, 400V ± 10%, 2-phase; 50 Hz or 60 Hz Fuse: 35A at 110V 20A at 208V to 400V Stereotactic biopsy device Accuracy for 100mm: Needle position in steps: Biopsy field size: Compression opening: Accommodates needle lengths: Needle holders: Open needle holders (localization): Film size: Cassettes: Weight, biopsy unit: Weight, evaluation unit: x,y,z 1.0 mm 0.1 mm 58 x 40 mm 0-140 mm from 30mm to 175mm 0.7mm (22G), 0.9mm (20G), 1.2mm (18G), 1.65mm (16G) 2.1mm (14G), 2.5mm ( 13G), 0.9mm (20G), 1.2mm (18G) 18cm x 24cm DIN 6832 / IEC 406 (15mm thickness) 12 kg 12 kg Installation Information X-ray stand including base plate: Generator with control console and radiation shield: Free standing radiation shield 300 kg 141 kg, 0.3mm Pb Eq. 46 kg, 0.1mm alt. 0.3mm Pb Eq. 8

A platform for the digital future Opdima Digital biopsy and spot imaging As the gold standard, Opdima offers the industry's largest field of view (49x85mm) and superior detector resolution for optimum clinical utility and image quality. Near real-time display sends the image quickly to the workstation for post-processing, diagnosis, target-setting, etc. With substantial time-savings versus film, Opdima means higher patient throughput and improved patient tolerance. The upgradeable MAMMOMAT 3000 Nova can be configured with Opdima initially or added later. MAMMOMAT 3000 Nova with Opdima FFDM Full-Field Digital Mammography 9 Digital imaging has many advantages over film postprocessing, image enhancement, better workflow and more efficient image transfer/archival and retrieval processes. But because of its very high requirements for image quality, resolution and viewing, mammography has been called the last modality to go digital. A guaranteed upgrade path ensures that your investment today is secure MAMMOMAT 3000 and MAMMOMAT 3000 Nova are the platforms for future digital technology.