Miami Heat Pump HP Series Installation Guide



Similar documents
Ceiling Mount Air Handler Manual

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Service & Parts Manual

Timer Fan Speed. Mode. Power _0

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Oil and Coolant Circulating Heating System. Model - OCSM


OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

1 For All Non-Programmable Digital Thermostat

Air Conditioning Systems Warranty Manual. Version 1.8

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Installation Manual DIAPHRAGM WELL TANK

Dehumidifier Users manual. For Models: DH45S DH65S

10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures

, User s Manual

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

LOBOY 16 AIR CONDITIONERS

Electric Water Heater

Heat Pump Water Heater IOM Manual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Installation Manual Version 7.3 IMPORTANT:

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

1/3 HP Submersible Sump Pump with Vertical Float Switch

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Installation Manual DIAPHRAGM WELL TANK

Powerware Relay-Serial Card User s Guide

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Portable Air Conditioner

Panel Mounted Air Conditioners by Dantherm, Inc.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

United Technologies USER'S MANUAL. Split Type Room Air Conditioner

T-Series Air Conditioner T62 Model

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

USER S MANUAL HSC-24A

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

INSTANT HOT WATER RECIRCULATING SYSTEM

GLACIER POOL COOLERS, LLC OPERATOR INSTRUCTIONS, INSTALLATION AND SERVICE MANUAL

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

How To Warranty A Car From Nordyne

OWNER S Manual PRINTED IN CANADA 10/2009

OTF Oil Fired Pool Heater

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

Customer Support

Installation Guide Smart-UPS X External Battery Pack SMX120BP

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

CARING FOR YOUR WATER HEATER

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Installation, Maintenance, & Repair Series 4000B/LF4000B

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Engineering Specifications

Limited Warranty. BARD MANUFACTURING CO., INC. BRYAN, OHIO Dependable quality equipment... since 1914

Sun Vinyl New Construction Windows Homeowner's Warranty

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Geyser-R Heat pump water heater Installation manual

What you can expect from your Solar Hot Water System

WARRANTY CERTIFICATE Please complete the following details and retain with the original purchase docket

Wine Cooler with Thermo-Electric Cooling & Heating Technology

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

MAC FAUCETS. Owner s Manual. Models: FA444

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Evaluate, Clean, and Tune Guidance

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

ECOFILTER PUMP VAULT

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Dealer Sales & Service Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Transcription:

CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source Series provides the best combination of performance and efficiency available. Safety devices are built into each unit to provide the maximum system protection possible when equipment is properly installed and maintained. GENERAL DISCRIPTION- The HP Water Source Series is a refrigeration machine that in the heating mode efficiently extracts heat from a water source (source side) such as well, lake, boiler/tower loop, or closed loop ground heatexchanger. The unit transfers the heat to another flow of water (load side) the amount of heat added to the load side is greater than the amount taken from the source since the electrical energy supplied to the compressor is added to the output. The HP Water Source Series single package unit consisting of compressor water to refrigerant evaporator coil, expansion valve (WP-with revering valve), and control panel with all necessary protection and safety circuit. SAFETY CONSIDERATIONS- Installation and serving of this system can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service equipment. All other operations should be performed by qualified personnel. WARNING before performing service or maintenance operation on system, Turn off main power to unit. Electrical shock could cause PERSINAL INJURY OR DEATH WARNING - before performing service or maintenance operation on system, turn off main power to unit. Electrical shock could cause PERSONAL INJURY or DEATH MOVING AND STORAGE Move unit in normal up position as indicated on the carton. DO NOT STACK MORE THAN THREE UNITS HIGH. When the equipment is received, all items should be carefully inspected and checked against the bill of lading to be sure all crates and cartons have been received. Examine units for shipping damage. Units in question should be internally inspected. If unit is damaged the carrier should make the proper notation on the delivery receipt acknowledging the damage LOCATION-

The unit should be centrally located with respect to the distribution system. The unit should be installed within the applicable area. If not, unit will be exposed to severe freeze damage that the warranty will not cover. Servicing of the electrical controls is performed from the front. The compressor can be accessed from the back. A minimum of 24 clearance in front and back of the system should exist. If the unit is installed on a floor over a crawl space, it should not rest on long, unsupported floor joists. Vibration may be crested in the joist with the crawl space acting as an amplifier box, resulting in undesirable noise. A drain pan is recommended where water released during start-up or maintenance could cause damage to floors. CAUTION before installation verify that the plug in back of drain pan is properly in place and secured. CAUTION before installation verify that the plug in back of drain pan is properly in place and secured. INSTALLATION- 1. Uncrate the unit and remove from carton taking special care not to damage unit. 2. Inspect the equipment s internal components. All compressor sized units are recharged with refrigerant. 3. Connect water supply and return lines to water inlets and outlets. Flexible Hose may be used for waterline to reduce possible vibration and improve unit serviceability. Consult local codes. Make sure hose or pipe or pipes are suitable for system water Pressure and sized for proper flow rate. START-UP PROCEDURES- BEFORE ENERGIZING THE UNIT, CHECK THE FOLLOWING: High voltage power supply is correct and in accordance with specified nameplate ratings. Field wire and circuit protection are the correct size Low-voltage control circuit is correct. Piping system is complete and correct. Vibration isolation has been provided. Unit is serviceable Unit access panels are recurred in place. Thermostat is in OFF position. INITIAL UNIT START-UP Set thermostat to highest position. Set thermostat system switch to COOL compressor should not run.

Reduce thermostat setting until the compressor reversing valve, loop pump is energized. Adjust water flow utilizing pressure/temperature plugs. Turn thermostat system switch to OFF position. Unit should stop running and reversing valve should be energized. Leave unit off for approximately five (5) minutes to allow for pressure equalization. Turn thermostat to lowest setting. Set thermostat system switch to HEAT position. Adjust temperature setting upward until unit is energized. Check for vibration, leaks, etc. Set thermostat to maintain desired space temperature. Instruct the owner on system operation. TROUBLE SHOOTING - a. Check power supply for adequate voltage. b. Check control circuit for proper connection. c. Check for loose wires. d. Check run capacitor. e. Check internal compressor ground or open winding, after compressor is cool NOTE Shut power and restart CAUTION THIS IS FOR INDOOR USE ONLY. Open high pressure switch a. Check water flow. b. Check water temperature. c. Check for scold or fouled condenser Open low-pressure switch a. Check water flow. b. Check water temperature. c. Check for scolded or fouled condenser. d. Check for loss of refrigerant charge. NOTE- If lockout on safety circuit occurs, check lend side heat transfer surface for adequate size. Shut power and re-energized. INSUFFICIENT COOLING OR HEATING Check the thermostat for proper location. Avoid outside walls and drafts.

Check water flow. Check refrigerant charge. Check system components. OPTIONS HEAT RECOVERY PACKAGES A factory installed heat recovery package is available for portable water heating e.g. swimming pool applications. CONTROL OPTIONS Various controls options are available, such as time delay relays, random start relays, aqua stats, etc. Consult your dealer for application insistence. DUCT CONNECTION Use duct tape to connect ducts to the A/C unit. For return airflow, connect duct with adapter which will be sized according to the following table in order to avoid air flow restriction. MODEL WIDTH HEIGHT INCHES HP024V 16 20 HP031V 16 20 HPX036V 16 20 HPX041V 16 20 HPX048V 24 32 HPX060V 24 32 CAUTION- Galvanized pipe or fittings are not recommended for use with these units due to possible galvanic corrosion. All plumbing, both supply water and discharge water lines must be sized to handle the required water flow with a minimum pressure drop. Closed loop and pond applications require specialized design knowledge. No attempt at these installations should be made unless the dealer has received specialized training. Pipe will sweat if low temperature water is run through the supply and discharged lines. These lines should be insulated to prevent damage from condensation. Solenoid valves used should be a slow closing diaphragm type. If not, water hammer may occur on unit start up or shut down. Placing the solenoid valve on the outlet side of the system helps this situation. CAUTION-improper heat exchanger water flow due to piping valving or improper pump operation is hazardous to units and constitutes abuse that will void heat exchanger and compressor warranty.

An in-line water screen strainer is recommended where poor water quality may exist. Ball valves with hose connections are recommended for back-flushing and chemical cleaning of the evaporator/condenser. Field wiring must comply with local and national fire safety and electrical codes. Power to the unit must be within the operating voltage range indicated on the nameplate or on the performance data sheet. On three-phase units, phase must be balanced within 6% CAUTION- Operation of unit on improper line voltage or with excessive phase imbalance will be hazardous to the unit and constitutes abuse and is not covered by warranty. Properly sized fuses or HACR circuit breakers must be installed for branch circuit protection. See equipment-rating plate for maximum size. The unit is supplied with on opening for attaching conduits. Connect the ground lead to the ground lug in the control box. Connect the power leads as indicated in the wiring diagram. COOLING TOWER/BOILER APPLICATION- (SEE FIGURE #l & #2) The cooling tower and boiler water loop temperature is usually maintained between 50 F to 100 F to assure adequate cooling and heating performance. In the cooling mode, heat is ejected from the unit into the source water loop. A cooling tower provides evaporative cooling to the loop water thus maintaining a constant supply temperature to the unit. When utilizing open cooling towers, chemical water treatment is mandatory to ensure the water is free from corrosive minerals. A secondary heat exchanger (plate form) between the unit and the open cooling tower may also be used. It is imperative that all air be eliminated from the source closed loop side of the heat exchanger to insure against fouling. In the heating mode, heat is absorbed from the source water loop. A holler can be utilized to maintain the loop at the desired temperature, In a milder climates a flooded tower concept is often used. This concept involves adding make-up water to the cooling water sump to maintain the desired loop temperature. CAUTION-Water piping exposed to extreme low ambient temperature are subject to freezing. Units are equipped with female pipe thread fittings. Consult the specification sheets. Teflon tape sealer should be used when connecting to the unit to insure against leaks and possible condenser fouling. Do not over tighten the connections. Flexible hoses should be used between the unit and the rigid system to avoid possible vibration. Both valves should be installed in the supply and return lines for unit isolation and unit water flow rite balancing.

Pressure/temperature parts are recommended in both supply and return lines for system flow balancing. Water flow can be accurately set by measuring the refrigerant to water heat exchangers water side pressure drop. See specification sheets for water flow and pressure drop information. FIGURE # 1 COOLLING TOWER/BOILER APPLICATION (Source Side) 1. Ball Valves 2. Hose kits 3. P/T plugs 4. Load side Connection 5. Low-voltage control connection 6. Vibration pad 7. Line-voltage disconnect 8. Supply and return lines of central system FIGURE # 2 WELL WATER APPLICATION (Source Side) 1. Pressure tank 2. Ball valve 3. Solenoid valve 4. Hose kit 5. P/T plugs 6. Load side connections 7. Low-voltage control connection 8. Vibration pad 9. Line-voltage disconnect

20233 NE 15 th Court Miami Fl 33179 Phone (866) 407-8535 Fax: (866) 406-6603 TERM OF LIMITED WARRANTY General warrants only to the original purchaser of a HP Series water source heat pump by. will furnish a new or rebuilt part during the first year limited warranty for any parts supplied by which has failed due to workmanship or material defect within the warranty period. Warranty Registration Return the warranty registration form to immediately after installation of the system. If the warranty registration is not returned, the warranty period will begin on the date of shipment from. In any event, the warranty initiate date shall be no later than sixty (60) days from the date of shipment from. will provide 1. A new or rebuilt part during Two years limited warranty for any part supplied by which fails as a result of defects in workmanship or materials within 24 months from date of installation. 2. A new or rebuilt refrigerant circuit part, reversing valve, refrigerant to water heat exchanger, refrigerant- to air heat exchanger, high and low pressure refrigerant switches, refrigerant expansion device, check valve (if installed). Filter drier or desuperheater ( if installed), during limited warranty which has been supplied by and fails due to defect in workmanship or materials within 24 months from date of installation (compressor is covered for 60months under the same conditions as above). will not provide: 1. Transportation costs of replacement parts to the installation site. 2. The cost of labor, refrigerant, materials, or service incurred in removal of defective part or in obtaining and reinstalling of the new or rebuilt part. 3. Any item other than repair or replacement of the unit itself. APPLICABILITY The warranty is applicable only to HP Series that are purchased and installed in the United States. This warranty is not applicable to: 1. Air Filter, fuses and refrigerants. 2. Units or parts, which have been moved from the location where they were initially installed 3. Products on which payment is in default. 4. Products which have damages or defects resulting from improper installation, wiring, electrical characteristics or maintenance or caused by misuse, abuse or accident, fire, flood, alteration and/or misapplication of the unit, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortage beyond control of or an Act of God. 5. Any portion of the system not supplied by. 6. Products which the model or serial number has been removed or defaced. 7. Units which have suffered damages resulting from water contamination, use of corrosive fluids, erosion, operation at abnormal water temperature and/or flow and unauthorized opening of refrigerant circuit. OBTAINING WARRANTY PERFORMANCE Warranty is valid for licensed contractors only. Contact your local distributor for details will charge a handling fee any parts, repair or service required. All items will be charged F.O.B. factory. Note: Certain states do not allow limitation on how long an implied warranty lasts or the limitation or exclusion of consequential or incidental damages so the foregoing may not apply. This warranty gives you specific legal rights and you may also have other rights from state to state. Change in legislation of compressor may require an additional fee. Limitations The warranty given in lieu of all other warranties or fitness for particular purpose and merchantability shall be limited to the duration of this express warranty. Manufacturer expressly disclaims and excludes any liability for consequential or incidental damage fir breach of any express or implied warranty.

20233 NE 15 th Court North Miami Fl 33179 Phone (866) 407-8535 Fax: (866) 406-6603 Warranty Registration First Name: * Last Name: * Phone Number: * ( ) - E-mail Address: * Product Model: * Serial Number: * Receipt/ Order Number Purchase Date: * / / Purchased From: * Installer Name * Price Paid: $. End User Copy First Name: * Last Name: * Phone Number: * ( ) - E-mail Address: * Street Address: * Address Line 2: City: * State: * Postal Code: * - Country: * Product Model: * Serial Number: * Receipt/ Order Number Purchase Date: * / / Purchased From: * Installer Name * Price Paid: $. Please return this bottom portion to Miami Heat pump at the above address Or register on our website: www.miamihp.com/warrantyregistration.html