4.0 DESCRIPTION OF SOURCES

Similar documents
KRUGER ENERGY CHATHAM WIND PROJECT ENVIRONMENTAL SCREENING REPORT / ENVIRONMENTAL IMPACT STATEMENT. Appendix E. Environmental Noise Impact Assessment

As a minimum, the report must include the following sections in the given sequence:

How Noise is Generated by Wind Turbines The mechanisms of noise generation. Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury

ENVIRONMENTAL NOISE ASSESSMENT PUBNICO POINT WIND FARM, NOVA SCOTIA

MCS 020. MCS Planning Standards. For permitted development installations of wind turbines and air source heat pumps on domestic premises

Sound Power measurements according to IEC

Siemens Wind Turbine SWT The new productivity benchmark.

UNDERGROUND OPERATION INTEGRA COAL UNDERGROUND NOISE MANAGEMENT PROGRAM (NMP) EMS Incorporating a Noise Monitoring Protocol

Noise from large wind turbines (with focus on low frequencies)

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT.

V kw The turbine that goes anywhere

Acoustic Terms, Definitions and General Information

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

Case Study 5 Use of Wind Turbine Technology

ENERCON WIND TURBINES

Bergen, Norway BNAM May Modern passenger trains in Norway - are they as quiet as we think?

GUIDELINE ON BOUNDARY NOISE LIMIT FOR AIR CONDITIONING AND MECHANICAL VENTILATION SYSTEMS IN NON-INDUSTRIAL BUILDINGS

DATE: July 12, 2004 SUBJECT: Gaudet School Chiller Noise Survey Results

Noise Assessment For Proposed EfW & IBA Facility. Paving Way North Hykeham Lincolnshire. For. Fichtner Consulting Engineers. Acting on Behalf of

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A)

Sound Power Measurement

Mark Bliss, BKL Consultants Ltd. # Lynn Valley Road, North Vancouver, BC, V7J 2A2 Canada

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

MODEL ORDINANCE FOR WIND ENERGY FACILITIES IN PENNSYLVANIA. This Ordinance shall be known as the Wind Energy Facility Ordinance for [municipality].

There s power in wind: fact sheet

EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE

V MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology.

Wind turbine database: Modelling and analysis with focus on upscaling. Master s thesis in the Master programme Applied Mechanics

WIND TURBINE TECHNOLOGY

Potential Effects of Wind Turbine Generators on Pre-Existing RF Communication Networks SEAN YUN. June Software Solutions in Radiocommunications

Nordex SE. Capital Markets Day Products & Sales - Lars Bondo Krogsgaard

Noise. CIH Review PDC March 2012

Annex H6. Clocaenog Forest Wind Farm Cumulative Assessment Figures

In the matter of the Dundonnell Wind Farm EES Planning Panels Victoria Proponent: Trustpower Australia Holdings Pty Ltd

Direct and Reflected: Understanding the Truth with Y-S 3

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

Comparison of predicted and measured wind farm noise levels and implications for assessments of new wind farms

Sound Pressure Measurement

Vibration mitigation for metro line on soft clay

HVAC Acoustic Fundamentals

Aircraft cabin noise synthesis for noise subjective analysis

Outline. Introduction to Wind Energy. US Wind Energy Installations. ME 483 Alternative Energy Engineering II 1

UCCS PES/ENSC 2500: Renewable Energy Spring 2014 Test 3 name:

6th International Meeting on Wind Turbine Noise Glasgow April 2015 Wind Turbines A Changed Environment

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

THE MODELING AND CALCULATION OF SOUND RADIATION FROM FACILITIES WITH GAS FLOWED PIPES INTRODUCTION

An Installers Guide to

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

LRS - Application Form PRESIDENT OF THE OFFICE OF ELECTRONIC COMMUNICATIONS

1.0 Background 1.1 Historical background 1.2 Cost of wind turbines

V MW & V MW (OFFSHORE)

APPLICATION NOTE AP050830

A clean energy solution from cradle to grave

Relationship between Sound Pressure and Sound Power Levels

EXPERT REMANUFACTURED WIND TURBINE

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

Sound Attenuation INTRODUCTION

Wind Turbine Power Calculations

HYDROMATRIX Jebel Aulia - Sudan

Wind Energy Math Calculations Calculating the Tip Speed Ratio of Your Wind Turbine

Excerpts from: Performance, Duration and Acoustic test reports for the Skystream 3.7 wind generator

Build Green Schools. Click on this link for more information.

Siemens D7 platform 6.0-MW and 7.0-MW direct drive wind turbines. The new standard for offshore. siemens.com/wind

WWD-1 1 MW wind turbine

The Role of Acoustics in Curtain Wall Design:

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Mobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012

Schindler 3300 / Schindler 5300 Information on noise and vibration.

A Method for Generating Electricity by Fast Moving Vehicles

Façade acoustic design strategy Proposed residential development Irvin Avenue, Saltburn

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

Offshore Platform Powered With New Electrical Motor Drive System

CASE STUDY. History. National Renewable Energy Laboratory Testing Wind Turbine Power Generators using PULSE. United States of America

Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia Devine

V MW Making wind even more profitable

Active noise control in practice: transformer station

APPENDIX F VIBRATION TESTING PROCEDURE

Case Studies on Paper Machine Vibration Problems

INTERNATIONAL ANNEX III. Technical Details of Sound Signal Appliances

Lecture 4 Energy Conversion in Wind Turbine

PART VIII: ABSORPTIVE SILENCER DESIGN

Vibration Analysis Services. FES Systems Inc. 1

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

German Test Station for Remote Wind Sensing Devices

Company Profile. Office Prague: Magnety, s.r.o, Politickych veznu 1531/9, Prague

GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY.

Infrasound levels near windfarms and in other environments

Difference in levels of groundborne noise and vibrations between the T-1300 and MX-3000 metro trains in Oslo

Noise Control Solutions For Standby Power Generators

Acoustic and Visual Impacts of a 0.25 MW WTG at Huasai, Nakhon Si Thammarat in Southern Thailand

NORDEX USA, INC. GREAT LAKES SYMPOSIUM

Document number #12 DNS Authors #20 Telephone: Date #40 AUGUST 2013

WIND AND SOLAR ENERGY DEVELOPMENTS IN IRAN

The development of renewable energy, including wind, solar, and

Atmospheric Effects On Traffic Noise Propagation Behind Noise Barriers

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

How To Reduce Noise From A Test Screen

Manual Analysis Software AFD 1201

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Transcription:

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 8 4.0 DESCRIPTION OF SOURCES 4.1 KEC Transformer Station Kruger Energy plans to build a transformer substation near Bowers Line and Vanedie Road as part of the Project. This substation will contain one 110 MVA transformer within the chainlinked fenced area (See Figure 2 & 6) The manufacturer s data sheet for this transformer indicates a maximum sound emission level of 76 (A) measured in accordance with the IEEE standard C57.12.90-1999. This is the average sound pressure level measured at a distance of 2 m from the transformer cooling fans. The data sheet is attached in Attachment C. The noise contribution from the substation is calculated using the DataKustik CadnaA version 3.7 environmental noise prediction software. The calculations are based on established prediction methods approved by the MOE: ISO 9613-2 standard entitled Acoustics Attenuation of sound during propagation outdoors Part 2: General method of calculation. For this analysis, the noise contribution from the substation was added to the noise contributions of the wind turbines to assess the total cumulative effect of the Project. IEEE C57.12.90-1993 standard, Distribution, Power, and Regulating Transformers has been used to develop the noise modelling parameters. This standard outlines a nearfield sound level specification for the transformer. Each transformer in this study is modelled having five radiating area sources. Four of which are representative of the sides of the transformer, while the fifth represents the top. The vertical area sources have been modelled to have a maximum source height of 4.33 m, which is the overall height of the acoustical vertical area enveloping the transformer. ATTACHMENT C provides the manufacturer s drawings outlining the physical height of the transformer. This modelling protocol is in accordance with the IEEE standard.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 9 4.1.1 Potential Sources of Noise Transformer noise is comprised of casing noise emitted from the operating transformer itself and cooling fan noise. Transformer noise has a pronounced audible tonal quality and has been considered in the analysis that follows. 4.1.2 Transformer Station Noise Emission Rating The acoustic measurement surface of a transformer is 10.56 m long by 6.70 m wide by 4.33 m high. The CadnaA acoustic model surface is taken to be 0.3 m from the transformer tank or transformer cooling fan whichever is more outboard. The calculated sound power level for each vertical surface is based upon the area of the acoustic measurement surface. The horizontal area of the top of the transformer is modelled in accordance with the IEEE standard for large transformers; in which the top is representative of 25% of the total vertical measurement surface area. Therefore, the calculated sound power level for the top of the transformer is based on 37.39 m 2. The tables below outline the sound power spectrum that was used for each transformer s four vertical area sources and top horizontal surface. Table 3: Transformer Average Sound Pressure Level @ the measurement surface Octave Band Center Freq. (Hz) Chatham Transformer As per IEEE standard C57.12.90-1999 (spectrum in ) 31.5 Hz 72.6 63 Hz 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz 4k Hz 8k Hz A 66.6 73.6 70.6 Table 4: Calculated Sound Power for Transformer Faces Octave Band Center Freq. (Hz) Transformer Northeast Long Face (10.56m x 4.33m @ 76 A) (spectrum in ) Transformer Southwest Long Face (10.56m x 4.33m @ 76 A) (spectrum in ) Transformer Northwest Short Face (6.7m x 4.33m @ 76 A) (spectrum in ) Transformer Southeast Short Face (6.7m x 4.33m @ 76 A) (spectrum in ) Transformer Top Face (37.39 m 2 @ 76 A) spectrum in 31.5 Hz 89.2 89.2 87.2 87.2 88.3 78.6 64.6 45.6 41.6 37.6 76.0 A 63 Hz 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz 4k Hz 8k Hz A 83.2 83.2 81.2 81.2 82.3 90.2 90.2 88.2 88.2 89.3 87.2 95.2 81.2 62.2 58.2 54.2 87.2 95.2 81.2 62.2 58.2 54.2 85.2 93.2 79.2 60.2 56.2 52.2 85.2 93.2 79.2 60.2 56.2 52.2 86.3 94.3 80.3 61.3 57.3 53.3 92.6 A 92.6 A 90.6 A 90.6 A 91.7 A

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 10 The above listed spectrums correspond to the total sound power level for each of the vertical area sources used to model the transformer for the typical worst case operating scenario as zero to full load with all cooling equipment operating. It should be noted that this spectrum does not account for tonality. Thus, a 5 penalty, consistent with MOE guideline NPC 104, has been included in this analysis. Consequently, the overall source sound power including tonality was amended to be 97.6 (A) for the northeast or southwest face and 95.6 A for the northwest or southeast face for purposes of this analysis to maintain additional conservancy in the model results. Similar to the vertical face sources, this spectrum does not account for tonality from the top face. Thus, following the same methodology noted above, a 5 penalty was included in this analysis. This creates an overall source sound power level for the top of the transformer, including tonality, of 96.7 (A). The tonal adjusted value of 96.7 (A) is utilized in this analysis to maintain additional conservancy in the model results. 4.2 Port Alma Transformer Substation The Port Alma Substation is currently operating on Simpsons Line near KEPA turbine T9. This substation has one 110 MVA transformer with a 76 A maximum noise rating, which is the same as the planned transformer for the KEC substation. All noise calculations for this ENIA include the noise contribution from both the KEPA and KEC substations. 4.3 Blasting Noise and Vibration Although not certain at the time of writing, given the proximity of bedrock to the ground surface at KEC, it is very unlikely that Kruger will need to perform blasting operations during the construction of the Project. Should blasting be required, noise and vibration levels from any required blasting activities will be required to meet the MOE guideline as set out in MOE publication NPC 119. Based upon NPC 119, if the entity in charge of the blasting operation carries out routine monitoring of peak pressure level, the peak pressure level limit for sound concussion resulting from blasting can be 128. If the routine monitoring is not carried out, then the peak pressure level limit for sound concussion from blasting should be 120. Consistent with NPC 119, if the entity in charge of the blasting operation carries out routine monitoring of vibration, the peak particle velocity limit for vibration resulting from blasting can be 1.25 cm/s. If routine vibration monitoring is not carried out, then the peak particle velocity limit for vibration from blasting should be 1.00 cm/s.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 11 4.4 Wind Turbine Generators The Project will utilize Siemens model SWT-2.3-101, model SWT-2.3-101 Low Noise, model SWT-2.3-93, and model SWT-2.3-93 Low Noise wind turbines. These are turbines designed for medium and high-wind sites and are well suited for energy extraction in the Chatham Kent area. As evidenced by the model classification, the Siemens SWT 2.3-101 has a nominal rating of 2.3 MW. It has a three-bladed upwind rotor that drives an electric asynchronous generator via a planetary gear. Each blade has a length of 49 metres. The Siemens SWT 2.3-93 has a nominal rating of 2.3 MW. It has a three-bladed rotor that drives an electric asynchronous generator via a planetary gear. Each blade has a length of 45 metres. The low noise model turbines are standard wind turbines SWT-2.3-101 and SWT-2.3-93 which have been modified to maintain noise emission below a certain threshold level. The KEC low noise model turbines will maintain the noise levels listed in Table 6 and Table 8. The Siemens turbine is a variable speed, pitch regulated upwind turbine with active yaw control and three blade rotor. A separate hydraulic pitch cylinder for each blade is situated within the nacelle. The generator and associated gearing are housed in a nacelle that is mounted on an 80 m high tower. The nacelle units are equipped with yaw motors to turn the nacelle into the wind. Additional information on the Siemens turbines is provided in ATTACHMENT B. Turbine coordinates are listed in Table 9. 4.4.1 Potential Sources of Noise There are several sources that contribute to the sound emitted by a typical wind turbine. As the rotating blades of the turbine extract power from the air-stream, the blades experience lift and drag forces. These forces generate sound, much in the same manner as a rotating propeller or fan also known as aerodynamic noise. The sound is predominantly tonal, with the fundamental sound established by the blade passage frequency, which is the product of the total number of blades and the rotation rate. For the proposed turbines the blade passage has a maximum frequency of 1 Hz. This is well below the audible frequency range (i.e., 20 Hz to 16,000 Hz). INFRASOUND Sounds with frequency contents below 20 Hz are referred to as infrasound. There are many other sources of infrasound such as those generated by winds, waterfalls, and the sound of waves breaking on the beach. Measurements at 200 m from typical units have shown that the infrasound levels are well below the level of perceptibility [1], [2]. As noted above, there are no non-participating Points of Reception within 400 m of a wind turbine and thus the potential effect of infrasound is not anticipated.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 12 AMPLITUDE MODULATION Perceptible sounds are generated predominantly by mechanical bearings, the electric generator and a characteristic swoosh which is essentially higher frequency broadband noise that is amplitude modulated at a low frequency [3]. In contrast to the first-generation wind turbines, some 30 years ago, innovations in blade geometry, materials, and mechanical systems have significantly lowered the sound power levels of present generation wind turbines. A recent study of wind turbine noise amplitude modulation [3] by the University of Salford, UK found that amplitude modulation occurs between 7% and 15% of the time, but the causes of amplitude modulation are still open to debate therefore the causes are not fully understood and that amplitude modulation cannot be fully predicted by current state of the art. The Salford study concludes that further research is recommended to improve understanding of amplitude modulation. The MOE does not recommend a penalty be applied to wind turbine noise due to amplitude modulation, ref [17]. WIND SHEAR EFFECTS Vertical Wind shear, sometimes referred to as wind shear or wind gradient, is a vertical difference in wind speed and direction over a relatively short distance in the atmosphere. For acoustic purposes, vertical wind shear is used as a measure of the change in wind speed at various vertical heights above ground level. Wind shear has been accounted for in the KEC noise assessment by adjusting the standard neutral stability wind turbine emission to an emission which accounts for the site specific average summer nighttime wind shear exponent. This approach is consistent with the recommendations of the MOE s Noise Guidelines for Wind Farms [17]. WIND TURBINE TONALITY As outlined in the Windtest measurement report (Attachment B), for all wind speeds the tonal audibility ΔL a,k is a negative number. This means that the tonality is below the tonal audibility criterion curve L a. Therefore, tones are not audible and penalties are not appropriate. CSA 61400-11 clearly states how to measure tonal audibility but does not specify how to apply tonal penalties. Aercoustics recommends that ISO 1996-2 be used to apply tonal penalties for wind turbines because it is an accountable international standard that is a good extension of CSA 61400-11. Therefore, based on the Windtest reports along with ISO 1996-2, a wind turbine tonal penalty has not been applied for the KEC Wind Project.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 13 4.4.2 KEC Wind Turbine Noise Emission Rating The SWT 2.3-101 has a rotor speed of 6 to 16 rpm therefore the resultant blade passage frequency is 0.30 Hz. Siemens has provided Kruger with noise warrantees for the Siemens wind turbines for wind speeds of 6ms/ to 10m/s with a quality assurance of +/- 1 A. See Table 5, Table 6, Table 7, and Table 8 below and Attachment B. Typical noise emission spectrums for 6m/s, 7m/s, 8m/s, 9m/s and 10m/s wind speed, for wind at a 10m reference height was provided by Siemens (see Attachment B). Table 5, Table 6, Table 7, and Table 8 presents all the turbine noise emission spectrums that were used in the noise assessment calculations. Table 5: SWT 2.3-101, Sound Power Spectrums @ wind speeds from 6m/s to 10m/s Siemens SWT 2.3-101 Electrical Rating: 2.3 MW Hub Height (m): 80m Wind Shear coefficient: 0.30 Octave Band Sound Power Level () Manufacturer s Emission Levels Adjusted Emission Levels Wind Speed (m/s) 6 7 8 9 10 6 7 8 9 10 Frequency (Hz) 63 106.8 108.7 108.7 108.7 108.7 108.7 108.7 108.7 108.7 108.7 125 107.9 109.5 109.5 109.5 109.5 109.5 109.5 109.5 109.5 109.5 250 104.5 105.7 105.7 105.7 105.7 105.7 105.7 105.7 105.7 105.7 500 102.7 104.3 104.3 104.3 104.3 104.3 104.3 104.3 104.3 104.3 1000 99.7 101.1 101.1 101.1 101.1 101.1 101.1 101.1 101.1 101.1 2000 95.1 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 96.2 4000 87.9 89.2 89.2 89.2 89.2 89.2 89.2 89.2 89.2 89.2 8000 85.7 87.3 87.3 87.3 87.3 87.3 87.3 87.3 87.3 87.3 Total A 104.6 106.0 106.0 106.0 106.0 106.0 106.0 106.0 106.0 106.0 Table 6: SWT 2.3-101 Low Noise model, Sound Power Spectrums @ wind speeds 6m/s to 10m/s Siemens SWT 2.3-101, Low noise model Electrical Rating: 2.2 MW Hub Height (m): 80m Wind Shear coefficient: 0.30 Octave Band Sound Power Level () Manufacturer s Emission Levels Adjusted Emission Levels Wind Speed (m/s) 6 7 8 9 10 6 7 8 9 10 Frequency (Hz) 63 107.5 108.6 108.6 108.6 108.6 108.6 108.6 108.6 108.6 108.6 125 108.6 109.1 109.1 109.1 109.1 109.1 109.1 109.1 109.1 109.1 250 104.3 104.6 104.6 104.6 104.6 104.6 104.6 104.6 104.6 104.6 500 101.4 103 103 103 103 103 103 103 103 103 1000 98.3 100.1 100.1 100.1 100.1 100.1 100.1 100.1 100.1 100.1 2000 94.6 95.3 95.3 95.3 95.3 95.3 95.3 95.3 95.3 95.3 4000 87 88.6 88.6 88.6 88.6 88.6 88.6 88.6 88.6 88.6 8000 84.7 86.8 86.8 86.8 86.8 86.8 86.8 86.8 86.8 86.8 Total A 103.7 105.0 105.0 105.0 105.0 105.0 105.0 105.0 105.0 105.0

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 14 Table 7: SWT 2.3-93, Sound Power Spectrums @ wind speeds from 6m/s to 10m/s Siemens SWT 2.3-93 Electrical Rating: 2.3 MW Hub Height (m): 80m Wind Shear coefficient: 0.30 Octave Band Sound Power Level () Manufacturer s Emission Levels Adjusted Emission Levels Wind Speed (m/s) 6 7 8 9 10 6 7 8 9 10 Frequency (Hz) 63 107.6 109.7 110.5 110.4 110.4 110.5 110.4 110.4 110.4 110.4 125 108.3 109.5 109.4 109.3 109.3 109.4 109.3 109.3 109.3 109.3 250 107.6 108.8 108.6 108.5 108.5 108.6 108.5 108.5 108.5 108.5 500 101.6 103.3 103.6 103.5 103.5 103.6 103.5 103.5 103.5 103.5 1000 94.7 96.8 97.5 97.4 97.4 97.5 97.4 97.4 97.4 97.4 2000 90.5 92.3 92.8 92.7 92.7 92.8 92.7 92.7 92.7 92.7 4000 87.2 88.1 87.7 87.6 87.6 87.7 87.6 87.6 87.6 87.6 8000 83.1 85.3 86.1 86.0 86.0 86.1 86.0 86.0 86.0 86.0 Total A 103.4 104.9 105.1 105.0 105.0 105.1 105.0 105.0 105.0 105.0 Table 8: SWT 2.3-93 low noise model, Sound Power Spectrums @ wind speeds 6m/s to 10m/s Siemens SWT 2.3-93, low noise model Electrical Rating: 2.2 MW Hub Height (m): 80m Wind Shear coefficient: 0.30 Octave Band Sound Power Level () Manufacturer s Emission Levels Adjusted Emission Levels Wind Speed (m/s) 6 7 8 9 10 6 7 8 9 10 Frequency (Hz) 63 109.5 111.3 111.3 111.3 111.3 111.3 111.3 111.3 111.3 111.3 125 109.7 109.6 109.6 109.6 109.6 109.6 109.6 109.6 109.6 109.6 250 107.8 107.3 107.3 107.3 107.3 107.3 107.3 107.3 107.3 107.3 500 100.3 102 102 102 102 102 102 102 102 102 1000 93.2 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 2000 90.2 91.9 91.9 91.9 91.9 91.9 91.9 91.9 91.9 91.9 4000 85.8 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 87.6 8000 80.7 86.2 86.2 86.2 86.2 86.2 86.2 86.2 86.2 86.2 Total A 103.0 104.0 104.0 104.0 104.0 104.0 104.0 104.0 104.0 104.0 The site specific average summer nighttime wind shear exponent was provided by Helimax, wind engineering consultants for Kruger. Attachment B also presents a detailed noise measurement report by Windtest GmbH for a single Siemens SWT 2.3-93 wind turbine according to IEC 61400-11 acoustic measurement standard. This turbine is identical in all respects to the SWT 2.3-101 planned to be deployed on the project, with the exception of the rotor (blade length). The Windtest report for the 101 turbine is not yet available as per correspondence from the manufacturer, but will be provided as soon as it is made available. Kruger s agreement with Siemens includes a guarantee on the sound power level associated with the four turbine models being provided.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 15 Table 9: Wind Turbine Locations KEC Wind Turbines UTM Coordinates Identifier Equipment Make & Model X (m) Y (m) Remarks T45 Siemens SWT 2.3-101 391879.00 4678926.00 T46 Siemens SWT 2.3-101 low noise model 384831.00 4668445.00 2.2 MW T47 Siemens SWT 2.3-101 384190.00 4669818.00 T48 Siemens SWT 2.3-101 low noise model 382940.00 4670568.00 2.2 MW T49 Siemens SWT 2.3-101 382658.00 4670903.00 T50 Siemens SWT 2.3-101 382029.00 4671600.00 T51 Siemens SWT 2.3-101 387011.00 4667807.00 T52 Siemens SWT 2.3-101 386759.00 4668111.00 T53 Siemens SWT 2.3-101 382926.00 4673818.00 T54 Siemens SWT 2.3-101 388888.00 4667531.00 T55 Siemens SWT 2.3-101 low noise model 388653.00 4667799.00 2.2 MW T56 Siemens SWT 2.3-101 387925.00 4668258.00 T57 Siemens SWT 2.3-101 387359.00 4668713.00 T58 Siemens SWT 2.3-101 384656.00 4671681.00 T59 Siemens SWT 2.3-101 384248.00 4673243.00 T60 Siemens SWT 2.3-101 384811.00 4675339.00 T61 Siemens SWT 2.3-101 low noise model 388779.00 4670854.00 2.2 MW T62 Siemens SWT 2.3-93 low noise model 391803.00 4669417.00 2.2 MW T63 Siemens SWT 2.3-93 low noise model 391565.00 4669722.00 2.2 MW T64 Siemens SWT 2.3-101 low noise model 389323.00 4672224.00 2.2 MW T65 Siemens SWT 2.3-101 low noise model 389050.00 4672523.00 2.2 MW T66 Siemens SWT 2.3-101 low noise model 388406.00 4673040.00 2.2 MW T67 Siemens SWT 2.3-101 low noise model 388177.00 4673370.00 2.2 MW T68 Siemens SWT 2.3-101 387962.00 4673984.00 T69 Siemens SWT 2.3-101 387707.00 4674289.00 T70 Siemens SWT 2.3-101 low noise model 391179.00 4673005.00 2.2 MW T71 Siemens SWT 2.3-101 low noise model 390969.00 4673242.00 2.2 MW T72 Siemens SWT 2.3-101 low noise model 390830.00 4673616.00 2.2 MW T73 Siemens SWT 2.3-101 low noise model 390535.00 4673897.00 2.2 MW T74 Siemens SWT 2.3-101 388183.00 4675879.00 T75 Siemens SWT 2.3-101 388043.00 4676750.00 T76 Siemens SWT 2.3-101 low noise model 392929.00 4674092.00 2.2 MW T77 Siemens SWT 2.3-101 low noise model 391848.00 4677051.00 2.2 MW T78 Siemens SWT 2.3-101 390648.00 4675861.00 T79 Siemens SWT 2.3-101 391186.00 4675959.00 T80 Siemens SWT 2.3-101 391580.00 4676174.00

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 16 KEC Wind Turbines UTM Coordinates Identifier Equipment Make & Model X (m) Y (m) Remarks T81 Siemens SWT 2.3-101 391251.00 4676552.00 T82 Siemens SWT 2.3-101 389949.00 4676442.00 T83 Siemens SWT 2.3-101 389897.00 4676890.00 T84 Siemens SWT 2.3-93 low noise model 397118.00 4671713.00 2.2 MW T85 Siemens SWT 2.3-93 low noise model 396907.00 4671991.00 2.2 MW T86 Siemens SWT 2.3-101 393107.00 4675812.00 T87 Siemens SWT 2.3-101 394620.00 4675246.00 T88 Siemens SWT 2.3-101 396659.00 4674812.00 T_GG01 Enercon E82 394675.00 4680518.00 Swanton Windfarm T_GG02 Enercon E82 394842.00 4680338.00 Swanton Windfarm T_GG03 Enercon E82 395429.00 4679823.00 Swanton Windfarm T_GG04 Enercon E82 395613.00 4679614.00 Swanton Windfarm T_GG05 Enercon E82 395809.00 4679398.00 Swanton Windfarm 4.4.3 Swanton Wind Farm GenGrowth Renewable Inc. is building a five turbine wind farm near the northeast corner of the Kruger s KEC proposed wind farm. The total noise impact assessment on Kruger points of reception includes the noise impact from all transformers and all wind turbines, including the noise impact from all GenGrowth turbines from the proposed Swanton wind farm. Noise emissions and turbine locations for this assessment is based on the data from the Swanton Wind Farm Noise Report, prepared by Boralex. Table 10: Swanton Wind Farm Sound Power Spectrums @ wind speeds 6m/s to 10m/s for Enercon E82 Enercon E82 Electrical Rating: 2.0 MW Hub Height (m): 78m Wind Shear coefficient: 0.30 Octave Band Sound Power Level () Manufacturer s Emission Levels Adjusted Emission Levels Wind Speed (m/s) 6 7 8 9 10 6 7 8 9 10 Frequency (Hz) 63 108.3 110.5 110.9 110.9 110.9 110.9 110.9 110.9 110.9 110.9 125 103.8 106.2 108.3 108.3 108.3 108.3 108.3 108.3 108.3 108.3 250 102.8 104.8 103.6 103.6 103.6 103.6 103.6 103.6 103.6 103.6 500 99.1 101.5 101.5 101.5 101.5 101.5 101.5 101.5 101.5 101.5 1000 95.3 98.5 100 100 100 100 100 100 100 100 2000 87.8 91.3 93.6 93.6 93.6 93.6 93.6 93.6 93.6 93.6 4000 77 80.2 82.1 82.1 82.1 82.1 82.1 82.1 82.1 82.1 8000 78.4 78.8 79.3 79.3 79.3 79.3 79.3 79.3 79.3 79.3 Total A 100.7 103.3 104.0 104.0 104.0 104.0 104.0 104.0 104.0 104.0

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 17 5.0 NOISE ASSESSMENT RESULTS 5.1 KEC Transformer Station Impact Assessment DataKustik CadnaA environmental noise model generated the worst-case results shown in Table 11. These results include sound power levels that account for tonality and contributions of the wind turbines. As indicated in the Table, and applying the conservative application of Class 3 (rural) areas to all Points of Reception, the transformers are not expected to meet the applicable noise guidelines without the application of abatement measures. The receptors identified in Table 11 are the worst-case receptors, closest to the KEC transformer. Table 11: Total Noise Impact without Transformer Noise Controls, 6m/s wind speed Receptor Description Distance to Transformer (m) Calculated Sound Level (A) Allowable Level R2152 2 storey residence, (on Vanedie Road) 553 41.6 A 40.0 A R2143 2 storey residence, (on Vanedie Road) 621 40.8 A 40.0 A 5.1.1 Transformer Noise Controls In order to satisfy the sound level limits at the receptor locations, a local acoustical barrier was applied as shown on Figure 6, 6B, 6C. The barrier would encompass the area proximal to the north, west, and south faces of the transformers, leaving the east and top faces exposed for cooling. The barrier would have a nominal height of at least 5.0 m (at least 0.7m above the top surface of the core of the transformer, see Figure 6C). The acoustical barrier would be constructed using Durisol sound blocks, or equivalent. The acoustical wall should be free of any gaps, openings, or discontinuities, and should have a surface weight of at least 4lb/ft 2 (20kg/m 2 ). Furthermore, the barrier should be an absorptive barrier to ensure that reflections are not a concern. 5.1.2 Cumulative Noise Effect Based upon the above design considerations, the acoustical barrier was inserted into the to DataKustik CadnaA environmental noise model. The model generated results as shown in Table 12. The resultant predicted worst-case conditions, are applied against the Class 3 (rural) designation, and account for transformer tonality and contributions from all wind turbines including neighbouring GenGrowth proposed wind turbines and KEPA turbines. Table 12: Cumulative Noise Impact with Transformer Barriers, 6 m/s wind speed Receptor Description Distance to Transformer (m) Calculated Sound Level (A) Allowable Level R2152 2 storey residence, (on Vanedie Road) 553 39.2 A 40.0 A R2143 2 storey residence, (on Vanedie Road) 621 38.8 A 40.0 A

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 18 5.2 Wind Turbine Impact Assessment The noise impact at 427 receptor dwellings has been predicted using a formula based on ISO 9613-2 Part 2; consistent with the MOE s modelling requirements. The locations and sound power levels of all the wind turbine sources, the transformer station sources and the location of the receptors were integrated into a master data file. Noise was predicted based on the following noise modelling protocol: Average Summer Nighttime Temperature = 19C Average Summer Nighttime Humidity = 60% G = 0.70 global ground attenuation factor Sound Level Limit = 40.0 A @6m/s wind @ 10m agl, i.e. precision to 1/10th of decibel Turbine noise emission adjusted to KEC specific conditions of average summer nighttime wind shear exponent =0.30 Analysis to include only turbines within 5km of a receptor for those receptors whose closest Chatham turbine is within 1.5km Two storey dwelling = 4.5m receptor height @ center of dwelling Single storey dwelling = 1.5m receptor height @ 30m from building face of dwelling The noise assessment was based on all of the recommended procedures outlined in the MOE s Noise Guidelines for Wind Farms, October 2008 ref [17], except that the calculated attenuation due to atmospheric absorption was based on site specific average summer nighttime temperature and humidity provided by Helimax. This is consistent with the intent of the MOE s noise guideline which is to determine maximum rated output of the wind farm and reflect the principle of predictable worst case noise impact. The highest noise level for each receptor, which represents the worst-case prediction, is outlined below in the assessment summary Table 14. The programme computes the octave band levels at the receptors from all the sound sources, including the transformers. The resultant A-weighted sound pressure levels are then transferred to the site map that shows both source and receiver locations. The detailed maps showing the locations of the wind turbines, transformer station, and the receptors are found in Figure 3. Some of the residences of the landowners that have entered into an Option to Lease Agreement with Kruger were considered participating and excluded from further evaluation. This is consistent with the MOE Guidance Note contained in Attachment A. Maximum sound levels have been predicted at all 427 dwellings and detailed calculations are provided in Attachment D. The maximum predicted sound levels at all non-participating receptors are predicted to be within the MOE environmental noise limits for Class 3 (rural) areas.

KEC Wind Project Environmental Noise Impact Assessment 18 July 2009 19 5.3 Wind Turbine Summary Tables The sound power emitted by the wind turbines and transformer station, as well as their location with respect to the receptors determines the sound pressure levels induced by the operation of all Project components. The acoustic power of each wind turbine as provided by the manufacturer is shown in ATTACHMENT B. The total noise impact at each receptor, including all wind turbines and transformer stations, has been summarized in the noise assessment summary table (Table 14). The predicted sound pressure levels, as well as the sound level limits as set by either MOE NPC-205 or NPC 232, are included for easy reference. The noise impact from the simultaneous operation of all wind turbines and transformers is less than or equal to the sound level limit associated with NPC 232 (i.e., 40.0 A). RPZ2065 and RPZ3328 are participating receptors whose dwellings will be demolished and rezoned agricultural. RPZ2064 is a participating receptor zoned agricultural whose dwelling will be converted to a storage building. The noise assessment summary table presents the predicted sound levels for all 427 dwellings that are located within 1,500m of a KEC wind turbine. It should be noted that receptor numbers are not perfectly contiguous due to various changes to the participating/non-participating stakeholder list over the course of project design activities and screening of all receptors within 2,000 meters of the proposed Chatham turbine locations. The closest non-participating receptor dwelling is Rs2590 which is single storey dwelling located 554m from Chatham turbine # 86. All other non-participating receptor dwellings are more than 554m from a proposed Chatham wind turbine. Table 13: Summary Table Legend T45 to T88 = Chatham turbine # 45 to Chatham turbine #88 T1 to T44 = Port Alma turbine # 1 to Port Alma turbine #44 T_GG01 to T_GG05 = GenGrowth Swanton windfarm turbine # 1 to #5 RP2166 (coloured red) = participating Chatham residential receptor # 2166 R2034(coloured black) = nonparticipating Chatham residential receptor # 2034 RN2130(coloured black) = nonresidential Chatham receptor #2130 Rs1968(coloured black) = nonparticipating Chatham single storey residential receptor #1968 Subscript "s" designates single storey dwelling.n designates point of reception 30m north of dwelling face, 1.5m above ground.e designates point of reception 30m east of dwelling face, 1.5m above ground.s designates point of reception 30m south of dwelling face, 1.5m above ground.w designates point of reception 30m west of dwelling face, 1.5m above ground

KEC Wind Project Environmental Noise Impact Assessment: 18 July 2009 20 Table 14: Wind Turbine and Transformer Noise Assessment Summary Point of Reception ID Receptor Height Receptor Description GPS co-ords Distance to nearest Chatham Turbine (m) Turbine ID Calculated Sound Pressure Level (A) at Selected Windspeeds (m/s) Sound Level Limits (A) at Selected Windspeeds (m/s) Background Level <=6 7 8 9 10 <=6 7 8 9 10 NPC 232 R2008 4.5 Residence 382035 4670661 668 T49 39.2 39.2 39.2 39.2 39.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2009 4.5 Residence 383474 4670058 738 T48 38.9 38.9 38.9 38.9 38.9 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2010 4.5 Residence 384466 4669027 687 T46 38.2 38.2 38.2 38.2 38.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2011 4.5 Residence 384835 4669296 830 T47 37.3 37.3 37.3 37.3 37.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2012 4.5 Residence 385179 4669645 1004 T47 35.1 35.1 35.1 35.1 35.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2013 4.5 Residence 383204 4672127 1288 T50 35.3 35.3 35.3 35.3 35.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2014 4.5 Residence 382988 4673100 721 T53 37.3 37.3 37.3 37.3 37.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2015 4.5 Residence 383156 4672989 860 T53 36.5 36.5 36.5 36.5 36.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2016 4.5 Residence 386706 4669077 748 T57 38.7 38.7 38.7 38.7 38.7 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2017 4.5 Residence 384201 4672069 598 T58 39.1 39.1 39.1 39.1 39.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2018 4.5 Residence 383635 4673529 676 T59 39.2 39.2 39.2 39.2 39.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2019 4.5 Residence 385425 4671984 827 T58 35.7 35.7 35.7 35.7 35.7 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2020 4.5 Residence 385395 4672052 827 T58 35.8 35.8 35.8 35.8 35.8 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2021 4.5 Residence 387480 4669852 1145 T57 35.2 35.2 35.2 35.2 35.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2022 4.5 Residence 384045 4673795 588 T59 39.1 39.1 39.1 39.1 39.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2023 4.5 Residence 388036 4669345 926 T57 37.6 37.6 37.6 37.6 37.6 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2024 4.5 Residence 388148 4669379 1033 T57 37.1 37.1 37.1 37.1 37.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2025 4.5 Residence 388171 4669390 1057 T57 37.1 37.1 37.1 37.1 37.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2026 4.5 Residence 388193 4669397 1079 T57 37.0 37.0 37.0 37.0 37.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2027 4.5 Residence 388223 4669384 1094 T57 37.0 37.0 37.0 37.0 37.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2028 4.5 Residence 388234 4669401 1113 T57 36.9 36.9 36.9 36.9 36.9 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2029 4.5 Residence 388285 4669397 1151 T57 36.9 36.9 36.9 36.9 36.9 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2030 4.5 Residence 388513 4669472 1349 T56 36.6 36.6 36.6 36.6 36.6 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2031 4.5 Residence 388558 4669404 1309 T56 36.7 36.7 36.7 36.7 36.7 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2032 4.5 Residence 384376 4674106 872 T59 36.0 36.0 36.0 36.0 36.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2033 4.5 Residence 385517 4673261 1269 T59 33.0 33.0 33.0 33.0 33.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2034 4.5 Residence 388243 4670611 589 T61 38.6 38.6 38.6 38.6 38.6 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2035 4.5 Residence 384919 4674594 753 T60 36.5 36.5 36.5 36.5 36.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2038 4.5 Residence 386968 4672719 1373 T67 34.3 34.3 34.3 34.3 34.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes Compliance with Limit (Yes/No)

KEC Wind Project Environmental Noise Impact Assessment: 18 July 2009 21 Point of Reception ID Receptor Height Receptor Description GPS co-ords Distance to nearest Chatham Turbine (m) Turbine ID Calculated Sound Pressure Level (A) at Selected Windspeeds (m/s) Sound Level Limits (A) at Selected Windspeeds (m/s) Background Level <=6 7 8 9 10 <=6 7 8 9 10 NPC 232 R2039 4.5 Residence 387926 4671625 1150 T61 35.5 35.5 35.5 35.5 35.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2041 4.5 Residence 388282 4671699 980 T61 37.2 37.2 37.2 37.2 37.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2042 4.5 Residence 385619 4675302 809 T60 35.5 35.5 35.5 35.5 35.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2045 4.5 Residence 386192 4675717 1432 T60 32.0 32.0 32.0 32.0 32.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2048 4.5 Residence 390522 4671633 1337 T64 38.2 38.2 38.2 38.2 38.2 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2050 4.5 Residence 390895 4671675 1360 T70 38.3 38.3 38.3 38.3 38.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2053 4.5 Residence 391196 4671655 1350 T70 38.7 38.7 38.7 38.7 38.7 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2056 4.5 Residence 389894 4675392 888 T78 38.6 38.6 38.6 38.6 38.6 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2057 4.5 Residence 389967 4675382 833 T78 38.9 38.9 38.9 38.9 38.9 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2058 4.5 Residence 391026 4674545 813 T73 39.1 39.1 39.1 39.1 39.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2059 4.5 Residence 391134 4674568 899 T73 38.8 38.8 38.8 38.8 38.8 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2066 4.5 Residence 392065 4675485 843 T80 39.5 39.5 39.5 39.5 39.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2070 4.5 Residence 392328 4675695 788 T86 39.7 39.7 39.7 39.7 39.7 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2071 4.5 Residence 390092 4678303 1426 T83 33.0 33.0 33.0 33.0 33.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2075 4.5 Residence 394429 4673888 1371 T87 36.6 36.6 36.6 36.6 36.6 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2076 4.5 Residence 391008 4678112 1192 T45 35.3 35.3 35.3 35.3 35.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2078 4.5 Residence 394673 4674040 1207 T87 36.0 36.0 36.0 36.0 36.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2079 4.5 Residence 391438 4678091 944 T45 36.5 36.5 36.5 36.5 36.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2081 4.5 Residence 394817 4674256 1009 T87 36.1 36.1 36.1 36.1 36.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2083 4.5 Residence 391870 4678044 882 T45 37.0 37.0 37.0 37.0 37.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2084 4.5 Residence 396006 4673479 1484 T88 35.0 35.0 35.0 35.0 35.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2085 4.5 Residence 396091 4673453 1473 T88 35.0 35.0 35.0 35.0 35.0 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2086 4.5 Residence 392202 4677931 949 T77 36.4 36.4 36.4 36.4 36.4 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2088 4.5 Residence 392512 4678011 1113 T45 35.1 35.1 35.1 35.1 35.1 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2090 4.5 Residence 392637 4678002 1195 T45 34.5 34.5 34.5 34.5 34.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2091 4.5 Residence 392709 4677927 1228 T77 34.3 34.3 34.3 34.3 34.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes RZ2093 4.5 Zoned Agriculture 397097 4674442 573 T88 38.9 38.9 38.9 38.9 38.9 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2094 4.5 Residence 396281 4675554 833 T88 35.5 35.5 35.5 35.5 35.5 40.0 43.0 45.0 49.0 51.0 40.0 Yes R2095 4.5 Residence 397262 4674481 688 T88 37.3 37.3 37.3 37.3 37.3 40.0 43.0 45.0 49.0 51.0 40.0 Yes Compliance with Limit (Yes/No)