Straight / Angulated Multi-Unit System

Similar documents
Standard Internal Hex

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Regular C/X Prosthetics. Prosthetics

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

NARROW DIAMETER implant

Implant Parts. A Radford Heath Guide 1

One Abutment - One Time

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

procedures & products NOBELESTHETICS including Procera

Restorative Guidelines

Gl GinGival level implant

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Multi-unit abutment bar overdenture

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Simpl Implant Abutments with Atlantis CAD CAM Technology

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

GINGIVAL LEVEL implant

Implant systems Systematically perfect

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

platform shifting Nobel Biocare is shifting gingival beauty to the next level

ExFeel Internal Excellent Feeling, Excellent Implant!

Implant Bar Overdenture Utilizing Locator Attachments

screw-retained single crowns using custom-cast abutments

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

All-on-4 treatment concept with NobelSpeedy Groovy

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

About DENTSPLY Implants

How To Use A Cresco

DENT IMPLANT restoring qualit S: of LIfE

CENÍK produkce CORTEX dental implants pro rok Cat.No. Název položky: Cena bez DPH: Cena s DPH:

screw-retained crown using a PEEK temporary abutment

SCD Case Study. Treatment Considerations for Implant Rehabilitation


STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

State-of-the-art for your prostheses

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Straumann Dental Implant System. Fax Order Form Collection.*

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

prosthetic technique manual

The IMZ Implant System

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Procedures & Products. NobelEsthetics

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

Prosthodontist s Perspective

LOCATOR BAR ATTACHMENT SYSTEM

AT THE RIGHT PRICE. ONE SIZE FITS ALL. FRICTION For a secure connection. BONEADAPT For immediate stability.

Laboratory Solutions. Optimization By Design

Edentulous patients. Straumann Dental Implant System

Guidance for implant removal. Straumann Dental Implant System

ball abutment overdenture: chairside pick-up using existing denture

Procedures & Products Powered by Procera. All-on-4

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

ERA. Attachment Systems. A SNAP to Use and Maintain

NobelActive. procedures and products

Attachments And Their Use In Removable Partial Denture Fabrication

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

TRI-CAM Implant System

Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases

DENTAL IMPLANTS. Product Catalog SCIENCE OF AESTHETICS IMPLANTS

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Self-Aligning Lowest Profile

What is a dental implant?

páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

ATLANTIS abutments as individual as your patients

Don t Let Life Pass You By Because Of Oral Bone Loss

Encode Restorative System Procedure & Laboratory Manual

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

PureForm Ceramic System. Emulating nature. The perfect disguise.

Restoring quality to life. Dental implants. A naturally better solution. Patient Education

Implants in your Laboratory: Abutment Design

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Dental Implants - the tooth replacement solution

Accelerated Patient Rehabilitation

Titanium Base for CAD/CAM For single-tooth and bridge solutions

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

IMPLANT DENTISTRY EXAM BANK

March 20, Dear Mr. Chen:

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Like natural teeth. Treatment procedure with dental implants SINGLE TOOTH REPLACEMENT

Modern Tooth Replacement Strategies & Digital Workflow

BICON DENTAL IMPLANTS

Transcription:

Straight / Angulated Multi-Unit System MIS Corporation. All Rights Reserved.

2. MIS Multi-Unit screw-retained abutments provide a superior yet simple prosthetic solution for screw-retained full and partial prosthetic appliances in almost every clinical scenario. These low profile connections come in different insertion angles and in varying gingival heights for surgical efficiency and exceptional aesthetic outcomes. 100% compatibility is assured using MIS implants in all connections types and platforms. Multi-Unit abutments are made of biocompatible Titanium Alloy Ti 6Al-4V and are tested for strength and durability. The MIS high quality surface finish ensures a precision fit. All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher. Warning: MIS products referred to in this document should be used by licensed dentists only.

3. Advantages Accurate Allows more precise impression-taking Special gripping bar for stable insertion Versatile Choice of insertion angles and cuff heights Corresponding prosthetic components engineered for fit Predictable Low profile with no sharp edges for better soft tissue healing Exceptional aesthetic results and reliability

4. Straight Multi-Unit Abutments Simple and easy to use, straight Multi-Unit abutments provide screw-retained restorative solutions for every clinical scenario in which implants with a divergence of up to 40º are used. Designed to fit all MIS implant connection types for optimal fit between abutment seat and implant connection. Straight Multi-Unit Abutment Package: Plastic gripping bar Straight abutment Insertion Path: Straight Multi-Unit abutments can be used with implants with divergence of up to 40º. 4.8mm 4.8mm ^ 40 ^ 2mm 2mm 1-5mm 1-5mm Internal Hex. Connection Conical Connection * Recommended tightening moment of 30 Ncm.

5. Straight Multi-Unit Abutments Insertion Procedure Do not exceed 30Ncm A B C A Use the plastic gripping tool to attach the abutment to the implant. B Remove the plastic tool with a slight bending movement. C Tighten abutment to 30Ncm using the ball attachment anchor key (MT-RB225) and torque wrench (MT-RI040).

^ ^ 6. Angulated Multi-Unit Abutments The perfect solution in cases where angulation correction is required, angulated Multi-Unit abutments are simple and easy to use. Options include: 17º angulation for use with implants with a divergence of up to 75º. 30º angulation for use with implants with a divergence of up to 100º. Angulated Multi-Unit Abutment Package: Metallic gripping bar Angulated abutment Insertion Path: 4.8 4.8 17º Multi-Unit abutments can be used with implants with divergence of up to 75º. 17 30 ^ 75 ^ 21 2.10mm 21 2.10mm 2.40mm H 1mm 3mm H 1mm 30º Multi-Unit abutments can be used with implants with divergence of up to 100º. 100 Internal Hex. Connection Conical Connection * Recommended tightening moment of 20 Ncm.

7. Angulated Multi-Unit Abutments Insertion Procedure Do not exceed 20Ncm A B C A Use the metallic gripping tool to position the abutment, and use the Multi-Unit key (MT-MUR02) to attach the abutment to the implant with a clockwise screwing motion. B Remove the metallic gripping tool with a counterclockwise movement. C Tighten abutment to 20Ncm using the Multi-Unit key (MT-MUR02) and torque wrench (MT-RI040). To screw in or unscrew angulated abutments, insert the Multi-Unit key into the lateral opening at the side of the abutment as shown.

8. Prosthetic Options Restorative options include single crowns, multiple-unit bridge restorations and full overdentures. Fixed, screw-retained bridge Low profile enables a variety of insertion options.

9. MIS supports two main types of overdenture restoration methods: Removable-bar restorations and fixed, screw-retained prosthetic devices. Both methods allow easy placement and can be removed as needed for oral hygiene treatment. Fixed, screw-retained prosthetic device Improved prosthetic support. Increased inter-implant distance. Removable, bar-retained overdenture Standard impression method. Standard restorative components. Improved esthetics.

CAD/CAM cementing cap MU-CC480 Gold bar coping abutment MU-BGC48 Plastic cylinder MU-CP048 Screw for angulated Multi-Unit EM-SA001 Healing cap MU-H4480 Impression coping, closed tray MU-IT480 Multi-Unit direct gold MU-MG480 Impression coping, open tray MU-I0480 Prosthetic Products Offering greater restorative flexibility, a special line of prosthetic components has been designed for both straight and angulated Multi-Unit abutments. Scanning abutment MU-SP001 Multi-Unit free rotation titanium temporary cylinder MU-TO480 Prosthetic gold screw MU-G0220 Analog MU-RSM48 Multi-Unit key MT-MUR02 Ball attachment anchor key MT-RB225 Prosthetic screw MU-S0220 Torque wrench MT-RI040 Multi-Unit abutments are made of titanium alloy Ti 6Al-4V ELI. This product is delivered non-sterile and must be sterilized prior to use by autoclave at 134ºC (273ºF) for 6 minutes. Do not exceed 134ºC during sterilization.

All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher. Warning: MIS products referred to in this document should be used by licensed dentists only.

MC-MUA08 Rev.5 02/2015 MIS Implants Technologies Ltd. www.mis-implants.com MIS Quality System complies with international quality standards: ISO 13485:2003 - Quality Management System for Medical Devices, ISO 9001: 2008 Quality Management System and CE Directive for Medical Devices 9342//EEC. Please note not all products are registered or available in every country/region.