M1500. Forta SPECIFICATIONS. Actuator for Valves. M1500 is an electro-mechanical actuator for the control of two-way and three-way plug valves in:

Similar documents
HERZ-Thermal Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Air damper actuators

EBS852 (Contrac) Power Electronic Unit

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Assisted lift operated 2/2-way solenoid valves Type EV250B

Digital input modules

Electronic Control Devices The European Product Catalogue 2007

Quick Connect. quick - simple - efficient.

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

MINI MCR-SL-R-UI(-SP)

Power Supplies 3. SDN-P DIN Rail Series

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

3/2-way Solenoid Valve, direct-acting, NC or NO

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Telephone- and leased line modem for industrial applications TD-36

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Servo Info and Centering

J TB/TW Temperature limiter, temperature monitor

Electronic Control Devices The European Product Catalogue 2007

CompactLogix Power Supplies Specifications

Duct Humidity Transmitter

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

49 Series - Relay interface modules A. Features

Pluggable interface relays CR-P Pcb relays

Color Mark Sensor with Red or Green LED E3S-VS

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Programming Logic controllers

48 SERIES Relay interface modules 10 A

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Model: DC-A2IO Advanced HVAC Controller

Data sheet ECC 12 and 22

SINEAX U553 Transducer for AC Voltage

RRV934. Multi-controller. Synco living

Waveguide Access Point WGA631. Product Guide

Rack mounted telephone- and leased line modem for industrial applications

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TAC I/NETTM MR-AHU-HP. Application Specific Controller

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Actuator for modulating control AME 435

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

650W Single Output Power Supply

Digital inductive conductivity transmitter

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Electronic overload relay EF19 and EF45

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

IO-RM3 3-Stage Relay Module

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Combi switchbox with integrated 3/2 way pilot valve

Speed Control Relays SX2

Redundancy Module QUINT-DIODE/40

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

MANTA Piston Distributor for Oil and Fluid Grease

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PHOENIX CONTACT Features

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Remote Monitoring and REC 501 Control Unit Product Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

How To Use A Flowmeter

TX OPEN RS232/485 module

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Cable Plug acc. to DIN EN , Form A

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Electronic overload relay EF65, EF96 and EF146

38 Series - Relay interface modules A

PCS0100en Persy Control Services B.V. Netherlands

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Cross-beam scanning system to detect slim objects. 100 mm in

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Overview of types. Technical data

Kit Watt Audio Amplifier

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

ABB i-bus KNX Fan Coil Controller FC/S 1.1

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

3DLevelScanner II TECHNICAL DATA SHEET

40.3. Control Relays and Timers

Transcription:

01 Actuator for Valves is an electro-mechanical actuator for the control of two-way and three-way plug valves in: domestic hot water systems heating systems air handling systems is either controlled by an increase/decrease 3-point floating signal or by a modulating 0 1 control signal. odulating control makes for a faster positioning of the actuator. SPECIFICATIONS Part numbers...see the table on the next page Supply voltage... +25%/ -20%, 50 60 Hz Power consumption... average 24 VA Transformer sizing.... 5A Running time odulating 9 25 mm (0.35-1 in.)...15 s odulating 25 32 mm (1-1.26 in.)...20 s odulating 32 52 mm (1.26-2.05 in.)...30 s Increase/decrease... 300 s/60 s Stroke................. 9 52 mm (0.35-2 in.) Factory set stroke.... 20 mm (0.79 in.) Thrust.... 1500 N (337 lbf.) Duty cycle.... max. 20%/60 minutes Analog input Voltage...0 1 Impedance... min 100 kω Digital inputs VH VC Voltage across open input............. Current through closed input... 5 ma Pulse time.... min. 20 ms Output 1 Voltage... DC ±0.3 V Load.... 25 ma, short-circuit proof Output Voltage... 2-1 (0-100%) Load... 2 ma Ambient temperature Operation... 10 +50 C (14 F - 122 F) Storage... 10 +50 C (14 F - 122 F) The electronic circuitry of the actuator ensures that the running time is the same, regardless of the stroke of the valve in question. It is easy to mount and connect the actuator. It can be mounted directly onto TAC s control valves, without any mounting kit. For Satchwell valves use L2SV linkage (see accessory). The working range of the actuator is adjusted automatically depending on the stroke of the valve. The electronic circuitry of the actuator then takes care of the adjustment of the valve end positions. The actuator is supplied by. It can provide a position indicator signal 2-1 and a DC voltage supply for older TAC controllers. Ambient humidity... max. 90% RH Enclosure rating... IP 54 Sound power level... max. 40 dba Standards Emission.... EN 50081-1:1992 Immunity.... EN 50082-1:1992 Heat... IEC-68-2-2 Humidity... IEC-68-2-3 Cold... IEC-68-2-1 Vibration... IEC-68-2-6 aterial Housing... aluminium Cover... ABS/PC plastic Color...aluminium/black Weight... 1.8 kg (3.96 lb.) Dimensions (mm).refer to the table on the next page

02 PART NUBERS Designation Explanation Part Number modulating control signal or increase/decrease signal 880-0450-000 -S2 modulating control signal or increase/decrease signal and end point switches 880-0451-000 DIENSIONS mm (in) 117 (4.60) 173 (6.81) 243 (9.57) 315 (12.40) 82 (3.235) Fig 1 44 (1.73) FUNCTION The actuator The brushless DC-motor of the actuator turns a screw via a gear wheel. The motor receives a control signal from a controller. The screw gets a linear movement which moves the stem of the valve. FUNCTION Control signal can either be controlled by an increase/ decrease signal or by a variable direct voltage. If an increase/decrease signal is used, the actuator normally moves inwards on an increase signal and outwards on a decrease signal, see Settings. anual operation handle raised (AUTO) anual operation There is a manual operation handle on the actuator, see figure 2. When it is lowered, the motor stops. Then, the actuator can be operated manually if the handle is turned. The actuator is supplied with the manual operation lowered. Position feedback actuators are equipped with a 2 1 DC position feedback signal, where 2 V always corresponds to the closed position and 1 to the open position (depending of switch nr.1). End point switches When actuators are controlled in sequence, it is possible to use the end point switches that have set positions. They will toggle when the valve is fully open or fully closed, respectively. Fig 2 anual operation handle LOWERED (AN) factory supplied

03 OUNTIN The actuator may be mounted horizontally, vertically and in any position in between, but not upside down, see figure 3. OUNTIN N.B. Do not use the actuator for the DN15 valves V298, V282, V294, V384, V386 and V394. To mount the actuator on a valve, slide the actuator onto the valve neck, thus making the square nut on the valve spindle fit into the groove on the cross bar. Then slide the brace into the groove on the valve neck and secure the nuts. Hot media hazard. Before removing actuator from valve or opening the valve, ensure that the valve control medium is isolated and relive the pressure. Work should only be carried out by a competent engineer. CONNECTIONS Fig 3 When T exceeds 120 we reccomend to mount the actuator between 45 and in horizontal position (see drawing) CONNECTIONS Block Function Description Supply voltage 24V AC rtm Supply voltage Input Control signals Input, neutral (VH, VC short-circuited VH Increase to ) VC Decrease Supply for RC 1 DC Feedback signal 1 23 4 56 7 89 0-100% N.B. When installed with three conductors, where the control signal reference is connected to, the motor current of the actuator will cause varying voltage loss in the cable and thus in the reference level., which has a highly sensitive control signal input, will detect the varying signal and follow it, which makes it difficult for the actuator to find a stable position. This variation may be accepted in simplified installations on the following conditions: the cables between the controller and actuator are shorter than 100 m (328 ft.), the cross-sectional area is larger than 1.5 mm2 (AW 16) and the cables are only connected to one actuator. Please refer to the figures labelled Simplified installation for wiring instructions. Cable lengths The cables to, and 1 should be max. 100 m (328 ft.) and have a cross-sectional area of min. 1.5 mm² (AW 16). Other cables should be max. 200 m (656 ft.) and have a cross-sectional area of min. 0.5 mm² (AW 20). Terminal block VH VC1 VH VC 1 24 V~

04 WIRIN EXAPLES K1 K2 KC VH VC Increase/decrease control odulating control, supply to the controller (TAC 239W, TAC 6711, TAC Xenta, TAC 8000, TAC 230U, TAC 2000, TAC 9000, TAC 77xx) Normal installation (4 wires to the actuator) Short cable installation (3 wires to the actuator) 1 1 Normal installation (5 wires to the actuator) 1 1 Short cable installation (4 wires to the actuator) odulating control, DC supply to the controller (TAC 218E/R, TAC 221L, TAC 228R/RL/ RF, TAC 239W, TAC 258R/RL, TAC 268R/ RL/RF) + OUT 1 Normal installation (5 wires to the actuator) + OUT PU 1 cabinet odulating control, galvanically isolated output in the controller (TAC 6501, TAC 6505) PU unit installation (4 wires to the actuator) Fig 6

05 Function in the OFF pos. ON position Description SETTINS 1 In Out Valve closing screw direction 2 odulating Increase/decrease Control (not at Sequence) 3 Sequence Sequence control 4 0-1 2-1 Voltage range 5 0-5 V, 2-6 V 5-1, 6-1 Part of voltage range 6 60 s 300 s Running time 7 Normal Inverted Direction of movement 8 Normal Linear/Logarithmic Valve characteristic 9 Operation End position adjust (mom.) Operation/End position adjustment Fig 8 IN OD ñ ñ ñ 0-10 0-5, 2-6 60 s NOR NOR OP O 1 2 3 4 5 6 7 8 9 N OUT INC SEQ 2-10 5-10, 6-10 300 s INV LIN/L ADJ There are nine switches in a row on the circuit board. On delivery ( Factory ), all switches are in the OFF position. 1 Valve Closing Screw Direction IN / OUT IN direction of movement is used when the screw of the actuator moves inwards to close the valve. 4 Voltage range 0-10 / 2-10 ou can choose whether to use the control signal voltage range 0-1 or 2-1. 5 Part of voltage range 0-5, 2-6 / 5-10. 6-10 ou can choose which part of a voltage range to use, the lower one 0-5 V (2-6 V) or the upper one 5-1 (6-1). OUT direction of movement is used when the screw of the actuator moves outwards to close the valve. Note = 2 V at close valve. 2 Control signal OD / INC TAC can either be controlled by a variable direct voltage, a so called modulating signal (OD), or by an increase/decrease signal (INC). 3 Sequence or parallel control / SEQ With sequence (or parallel) control (SEQ), two actuators/valves can be controlled by only one control signal. For each of these you can choose which part of the voltage range to use, the upper one, 5-1 (6-1) or the lower one, 0-5 V (2-6 V). If the switch NOR / INV is in the NOR position, the higher voltage corresponds to 100% flow and the lower one to 0%. With NOR / INV in the INV position you will get the opposite function. Note If sequence or parallel control is not used, the switch / SEQ must be in the OFF position, as the switch OD / INC is not valid during sequence or parallel control. If the switch is in the NOR position, the higher voltage corresponds to 100% flow and the lower one to 0%. To achieve the opposite function, the switch should be put in its INV position. 6 Running time 60 s / 300 s With increase/decrease control, you can choose a running time between 60 s or 300 s. With modulating control, the running time is always 15 s / 20 s / 30 s depending of stroke valve. 7 Direction of movement NOR / INV When normal direction of movement is used, the screw of the actuator moves inwards when the control voltage decreases or if the actuator gets a decrease signal. With the switch NOR / INV, the direction of movement can be changed. 8 Linearization NOR / LIN/L The motorized valve characteristics can be modified. If you wish for the characteristics to be affected, the setting LIN/L will make the characteristics of an equally modified percentage (EQ) valve almost linear. On the other hand, with LIN/L a motorized valve equipped with a linear valve will operate with Quick open characteristics. This means that with a small control signal, the valve will be almost completely open.

06 Note For the actuator to register new settings of the switches, the supply voltage must be cut or the manual operation handle lowered, the settings done, and then the handle raised again. Please refer to illustration on page 2. (This does not apply to the switch OP/ADJ). 9 End position adjustment OP / ADJ This switch is only used to adjust the end positions when the actuator is commissioned. omentarily put the switch in the ON position. The actuator will automatically find the end positions of the valve. ACTUATOR INSTALLATION Before installing it is necessary to remove the antistatic protection placed under the cover. The switches on the circuit board should be set before the actuator is installed. There are no other switches or potentiometers that should be set or adjusted. To make an end position adjustment, you only have to switch the switch»op/adj«into its ADJ position, when the supply voltage has been turned on, and then back to its OP position. When an end position adjustment is made, closes the valve and opens it fully. The adjustment is finished by the actuator closing the valve again; the electronic circuitry then adjusts the stroke and the running time to the valve. The set values are stored in the EEPRO of the actuator so that they will remain after a loss of voltage. When the end position adjustment is complete, the actuator starts to control the valve according to the control signal. AINTENANCE The actuator is maintenance-free. ACCESSORIES S2-... 880-0104-000 CIrcuit board.... 1-001-0677-0 Linkage Satchwell valves L2SV.... 880-0124-000 See data sheet Valves and actuators Summary (F-10-06) On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. All brand names, trademarks and registered trademarks are the property of their respective owners.