T Series. The most reliable HVAC system for transit is now better than ever.

Similar documents
IV. Rear Mount System

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

HVAC units for tramways, trains and metros Proven performance, high reliability and low life cycle cost

XIV. Electrical / Electronics

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Diesel Engine Driven Generators Page 1 of 6

Installation Manual CLIFC Fan & Coil Variable Speed

Electronically Controlled Clutchless or Variable Drive Compressors

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

HP switch LP switch Discharge thermo Comp. Surface thermo

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Refrigeration Series for Direct Drive Truck

FOXAIR 60/50 ALL MODELS

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Air conditioning, electrical testing

Air-cooled Chillers with High Speed Centrifugal Compressors


1 Temperature Derating Guide

CC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N A

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

, User s Manual

This slide is hidden. It will not show up during presentation.

Bus Air Conditioning and Heating Unit

Basic Nameplate Information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Air Conditioning 101. STN Presentation AC101

A Practical Guide to your Warranty Plus Plan for Vehicle Powered units

Digi-Motor Installation Guide

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LOBOY 16 AIR CONDITIONERS

Refrigeration Compressed Air Dryer Buran Ultrapulse

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EFFECTIVE OCTOBER Atwood Furnaces. and Digital Thermostats

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

york air-conditioning products Residential & VRF News 2015

32VFD Variable Frequency Drives for Centrifugal Chillers

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Introduction. Motor Types

Air Conditioning System

Wynn s Extended Care

Air Conditioning Sign-Off Sheet

6. Diagnostics for A/C System Malfunction

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

MAC-120HE-01 Air-Cooled Chiller

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Heating and Air Conditioning

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

TWE+TTA TWE+TWA T.R.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Tim Sisson - Trane HVAC OVERVIEW

CE6500 Energy Recovery Ventilator

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Air Conditioning Systems

FULL DC INVERTER SYSTEMS

ASE 7 - Heating, Ventilation, and Air Conditioning. Module 8 Diagnosis, Testing & Repair

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

Explosion-Proof Electric Unit Heaters

Rotary screw compressors kw 5,5 7, , bar MODULO

2013 Tier 4 Compliant. High capacity and reliability. Low fuel consumption and noise. Let Vector units energize your bottom line.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

Unidrive M Energy Savings

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

CRAC Precision climate control units for data centres

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

SPEED CONTROL SYSTEM

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

C18 ACERT Fire Pump Tier bkw/ rpm

FTQ. Daikin Inverter Ducted Heat Pump

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

ECOCIAT. Domestic hot water heat recovery unit

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Product Data. Split System Cooling F-EN. March 2015

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Heavy Duty Industrial Air Compressors

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Why and How we Use Capacity Control

AIR-CONDITIONER SPLIT TYPE

Aerosphere Midibus. Air Conditioning System. Operation Manual. Aerosphere Midibus 05/2013 P.N A

Commercial Gas Furnace Upflow

Transcription:

T Series The most reliable HVAC system for transit is now better than ever.

High performance and reliability for more than 30 years T-Series: The HVAC design that changed an industry. Low life cycle costs Performance proven components provide long service life and minimum maintenance for low life cycle costs. Lightweight Lightweight all aluminum frame, blowers, coil headers and compressor reduce bus stress and fuel consumption. Easy to service Convenient service access to all major components. Simplified electrical troubleshooting with microprocessor controls. Removable access panels and a convenient rear window location provide easy access to unit components for repairs or maintenance. Same major components and options across platform. T Series units have many of the same internal components in the electrical and refrigeration systems, assuring a readily available supply of parts and parts interchangeability to lower costs and minimize downtime. Easy to install T Series units are easy to install and service because of the compact, one-piece design. Proven dependability You know you re getting a dependable, reliable bus air conditioning and heating system that can lower your operating and maintenance costs and keep your bus riders cool. Best Value, Best Performance.

Thermo King offers system diversity to fit your individual requirements. Unmatched versatility to meet customer specifications 2 Refrigerant Options R134a R407C A 3 Motor Options Brushless Wound Field Permanent Magnet B 3 Compressor Options X426/X430 S391 Screw S616 Screw C Unit A B C Weight (Depth) (Height) (Width) T 14 683 mm 902 mm 1636 mm 168 KG (26.9 ) (35.5 ) (64.4 ) (370 lbs) T 15 658 mm 963 mm 1618 mm 173 KG (25.9 ) (37.9 ) (64.4 ) (380 lbs) The Best Solution Available for CNG Rear Mount Applications!

T-Series Standard Features Why pay for more than you want. Thermo King provides standard features designed to meet your needs. Thermo King s IntelligAIRE III Control System Delivers Industry-Leading Capability with Unmatched Ease-of-Use 3 Multiple zones can be controlled using identical expansion modules via CAN network and interconnected software 3 Expanded CAN communication capability to plug directly into the vehicle s J1939 network 3 Operator-friendly display and pressure modules for improved control and diagnostics Four simple modules remove complexity for operators and technicians 1 2 3 PRESSURE PSIG SUCT 1 DISCH 1 SUCT 2 DISCH 2 Display Module Pressure Display Module Main Module IO Module High Performance R-407C Environmentally safe alternative that provides more BTUs of cooling per HP used R-134a Refrigerant Environmentally-friendly solution The Thermo King X430 Compressor Engineered exclusively for transport applications Built for extended service life Field repairable Additional Standard Features Evaporator fan motor - Heavy-duty, double shafted industrial permanent magnetic motor with replaceable bearings and brushes - 27V, 1.15 hp, 1700 rpm (high speed) - Drives two large, high airflow, forward curved, centrifugal blowers Condenser fan motors - Two, heavy-duty, industrial permanent magnet motors with replaceable bearings and brushes - 27V,.75 hp, 1900 rpm (high speed) - Each motor drives a 457 mm (18 in.) diameter axial flow fan

T-Series Optional Features Take control of your operating costs with these cost-saving options available only from Thermo King. Thermo King Brushless Motors 114-lb. Weight Reduction for Improved Fuel Economy! Designed Specifically for Mobile Air Conditioning Lower Your Operating Costs Eliminates High Brush Maintenance Costs Fewer Parts to Maintain and Replace - Electronic Package is Integral to Motors, Eliminating External Controllers, Harnesses, Terminals and Studs for Lower Costs Advanced Diagnostics Provide Failure Mode Indication PRESSURE PSIG SUCT 1 DISCH 1 SUCT 2 DISCH 2 IntelligAIRE III Electronic Pressure Display Module Touchpad displays four different pressure readings Simplifies problem diagnosis and pre-trip inspections S391/S616 Screw Compressors Exclusive oil management system for increased reliability Fewer moving parts than reciprocating compressors Lower noise levels and vibration than reciprocating compressors Programmable capacity control for fuel savings Electronic Energy Management System Provides fuel savings with X426, X430 and X640 reciprocating compressors Programmable electronic capacity control reduces the parasitic load on the engine High Performance Clutch Long-life sealed bearing More torque for heavyduty applications Extended maintenance intervals Additional Optional Features Wound field condenser & evaporator fan motors Modulating water valve 125 amp, 27V dc batteryless alternator (independently powers fan motors and controls)

T Series Specifications Evaporator Airflow* * 0 mm (0 in.) water column external static pressure High speed fan - 3814 m 3 /hr (2250 cfm) Low speed fan - 2366 m 3 /hr (1400 cfm) * *Consult factory for optional airflow on high speed or low speed fan operation. Performance Data System net cooling capacity with 35 C (95 F) ambient, and 26.7 C (80 F) db, 19.5 C (67 F) wb evaporator return air (50% RH): Refrigerant HFC R-407c* Compressor Net System Capacity RPM Btu/hr KCal/hr HP 1000 66,700 16,808 7 1800 88,400 22,277 15 2400 97,300 24,520 21 2800 101,000 25,452 24 Refrigerant HFC-134a* Compressor Net System Capacity RPM Btu/hr KCal/hr HP 1000 45,700 11,516 6 1800 73,600 18,547 12 2400 83,900 21,143 15 2800 86,000 21,672 18 * Nominal cooling system capacities shown above may vary depending upon the specific T Series unit model (frame size) selected. Consult factory for more specific performance data for your application. System Heating Capacity 24,696 KCal/hr (98,000 Btu/hr) @ 8 GPM & 160 F water Electric Power Requirements AT 27V dc High speed fan: 106 amps (high speed evaporator and condenser fans) Power source: Bus alternator or Thermo King batteryless alternator (options below) Unit Operation W/Driver Mode Switch Reheat: Compressor clutch continuously engaged, boost pump and water control valve cycling is controlled by thermostat. Cool: Compressor clutch cycles On/Off on demand of thermostat. Vent: Evaporator fan operation only. Heat: Boost pump and water control valve cycle on demand of thermostat. Compressor clutch off. Add Thermo King s T-Series HVAC System to Your Specification Today!

T-Series All-Electric HVAC Options Help Drive Energy Efficiency and Sustainability in Your Organization! TEA Series TE Series Power Circuit - Alternator Powered Electric Unit 150-600 VAC 3PH Alternator Voltage Regulator 700 VDC Regulated DC Supply Inverter Inverter Inverter 300-500 VAC 3PH Variable Frequency 45Hz-75Hz 100-500 VAC 3PH Variable Frequency 15Hz-75Hz 100-500 VAC 3PH Variable Frequency 15Hz-75Hz 24 VDC Compressor 1 Compressor 2 Condenser 1 Motor Condenser 2 Motor Evaporator Motor Coolant Pump Controller 2A / 24 VDC Generator Battery Pack Disconnect Switch Power Circuit - Typical Hybrid Electric 350DC Inverter Bus Charging System Shore Power 230 VAC 24 VDC 230 VAC 3PH Compressor 1 23 A Compressor 2 23 A Condenser 1 2.8 A Condenser 2 2.8 A Evaporator 4.6 A Controller 2 A Bus Charging System For use on standard diesel engine-driven buses. For use on hybrid electric and all-electric buses. Engine driven 600 VAC Alternator For complete All-Electric specifications, see your local Thermo King dealer or call 952-887-2241

Ingersoll Rand s Climate Solutions sector delivers energy-efficient HVACR solutions for customers globally. Its world class brands include Hussmann, a manufacturer of refrigeration and food merchandising solutions, Thermo King, the leader in transport temperature control and Trane, a provider of energy efficient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes. Distributed by: TK 30274-3-PL (9-11) 2011 Ingersoll-Rand, plc Printed in U.S.A.