QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Similar documents
SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

Rexroth Hydraulic Pump A10VO Series User Manual

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

MODEL G300 BRAKE BLEEDER

1/3 HP Submersible Sump Pump with Vertical Float Switch

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OWNER S Manual PRINTED IN CANADA 10/2009

SSNICLRG SSNICSM PLNICLRG PLNICSM

SunMaxx Solar Filling Station Operating Instructions

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

3 WATT LED SPOTLIGHT Model No. SLM

Installation Instructions

Water Tec of Tucson Water Systems

PAINT SPRAY GUN WASHER

Installation Manual DIAPHRAGM WELL TANK

ClearView 100. Instruction Manual

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

User Manual (English)

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

BLAST CABINET ABRASIVE Rev SAVE THESE INSTRUCTIONS. Important Safety Instructions are included in this manual

SINGLE STAGE INLINE FIRE PUMP

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

accidents which arise due to nonobservance and the safety information herein.

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

What you can expect from your Solar Hot Water System

INSTALLATION AND INSTRUCTION MANUAL

Micron-Master EL Series Fogger

WARNING WARNING TABLE 1.

Ceiling Mount Air Handler Manual

100 Series Maxi Internal Filters. Instruction Manual

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

MODEL INSTALLATION INSTRUCTIONS

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

SYSTEM 3 MODULAR MEDIA FILTER

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

IMPORTANT INFORMATION SERIAL NUMBER

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

INSTANT HOT WATER RECIRCULATING SYSTEM

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

MP-4V Heavy Duty Riveter / 39048

15GAL STEEL OIL DRAIN WITH 110V PUMP

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

O W N E R S M A N U A L SERIAL NUMBER

MODEL # Introduction

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

RT-200 HI-TEST ROPE TESTER

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Low Voltage Pool Transformer

Maintenance Guide For Above Ground Pools

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Mini-led spotlight with magnetic base

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

PNEUMATIC PLANISHING HAMMER

55-Gallon Dispenser Package

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Advantium 2 Plus Alarm

Global Water Instrumentation, Inc.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Aqua Vac Pool Cleaners 1711 Longwood Road West Palm Beach, FL Attn: Warranty Records

Installation, Maintenance, & Repair Series 4000B/LF4000B

Air vacuum pump with r134a & r12/22

TITAN 13 x 2 ½ BRAKES

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Air Conditioning Systems Warranty Manual. Version 1.8

Pool FROG. Instruction Manual. ABOVE GROUND MINERAL SYSTEM FOR POOLS Patented Mineral Pool Sanitizer. Customer Service

Installation Manual DIAPHRAGM WELL TANK

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

OTF Oil Fired Pool Heater

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

123 Industrial Loop Road Paynesville, MN Phone:

B-AIR BLOWER CUB POWER MODEL # CP-1

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Owner s Manual & Safety Instructions

Battery Charger. Instruction Manual G

tire inflator with pressure gauge

The Storm 20-Gallon Wet/Dry Vac

ROTOR LOADER OWNER S MANUAL

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Miami Heat Pump HP Series Installation Guide

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Say Hello to Your Precision Cooker

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

PALLET JACK TON

Customer Support

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Transcription:

QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed and serviced by a qualified technician in accordance with all applicable codes and ordinances. Improper installation can create hazards which could result in property damage, serious injury or death. Improper installation will void the warranty. The NOTICE label indicates special instructions that are important but not related to hazards. Notice to Installer This manual contains important information about the installation, operation and safe use of this product. Once installation is complete, this manual must be given to the owner/ operator of this equipment.

TABLE OF CONTENTS SAFETY INFORMATION...2 SAND FILTER BREAKDOWN....2 INSTALLATION...3 MULTIPORT VALVE OPERATION...3 INITIAL STARTUP OF FILTER 4 BACKWASHING 5 MAINTENANCE 5 SPECIFICATIONS.6 TROUBLESHOOTING.6 SAFETY INFORMATION READ ALL WARNINGS BELOW. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH *RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS INJURY OR DEATH. DO NOT BLOCK SUCTION AT THE PUMP OR IN THE POOL AS THIS CAN CAUSE SEVERE INJURY OR DEATH 1. Sand Filters are designed to work with water at a temperature > than 32º F and < than 113ºF. The filter should never be operated outside of these temperatures or damage may occur. 2. The installation should be carried out in accordance to the safety instructions of swimming pools and the specific instructions for each location. 3. The user should make sure that the installation is carried out by qualified authorized professional and adhere to local code & regulations. Avoid Electrical Shock Do Not Use power extension cords. 4. Connect ONLY to a Ground-Fault Circuit Interrupter (GFCI) power outlet. Consult a qualified, professional electrician for safe and proper installation of the required electrical outlet. 5. The operating safety of the filter is only guaranteed if the installation and operation instructions are correctly followed. CAUTION Check to ensure that air is out of the system before operation. Any trapped air can cause the tank cover to explode which could result in death, serious injury, or damage to the system. 6. To reduce the risk of injury, do not permit children to use this product. Install the product at least 10 feet away from the pool to prevent children from using the system to access the pool. 7. Incorrectly installed equipment may fail, causing severe injury, property damage or death. 8. Chemicals and fumes can weaken Swimming Pool/ Spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury, property damage or death. Do not store pool chemicals near your equipment. Any modification of the filter requires the prior consent from the supplier s original replacement parts and accessories authorized by the manufacturer to ensure a high level of safety. The supplier assumes no liability for the damage and injuries caused by unauthorized replacement parts and accessories. 9. In the event of defective operation or fault, contact 877-278-2797 immediately for assistance. 10. DO NOT OPERATE THE SYSTEM WHILE THE POOL IS IN USE. 11. Never Allow Children to Operate this Equipment How the Sand Filter/Pump Works Incoming water from the piping system is automatically directed by the Multiport Valve to the top of the filter bed. As the water is pumped through the filter sand, dirt and debris are trapped by the filter bed, and filtered out. The filtered water is returned from the bottom of the filter tank, through the Multiport Valve and back through the piping system.

Preparation Before Installation 1. The filter should be placed on a level concrete slab, very firm ground, or equivalent. Ensure that the ground will not subside, preventing any strain from the attached plumbing. 2. Position the filter under consideration of the piping connections, so that it is convenient for operating and servicing. 3. Ensure that the compliance label is facing the front to allow easy identification in the case of service difficulties. How to Install the System INSTALLATION 1. Mount the pump to sand filter support by using bolts and nuts. 2. Install the drain plug assembly to sand tank as below pictures. 3. Press and turn the sand tank to mount it to sand filter support with correction direction (drain plug is at outside as below picture).

4. Insert the tube with the diffuser body inside the tank as above picture, then place the funnel on the tank s mouth and pour 45lbs of the No. 20 Silica Sand with particle size of 0.45 mm-0.55mm sand into the tank 5. Take away the funnel, and then clean really carefully the tank s neck and fix the valve with O-ring through flange clamp set. (the direction of PUMP port on valve needs to face pump out port) 6. Connect the sand tank to pump with hose, hose clamps and hose adaptors. Installation Notes 1. Ensure solvents are not excessively applied to fittings as this could run into O-ring and create sealing problems. 2. Do not over tighten fittings or adapters

HOW TO USE 1. Inspect all the connections have been made correct and are secure. 2. Depress top mount valve handle and rotate to BACKWASH position. 3. Prime and start pump according to pump instructions. NOTE: ALL SUCTION AND DISCHARGE VALVES MUST BE OPENING WHEN STARTING THE SYSTEM. FAILURE TO DO SO COULD CAUSE SEVERE PERSONAL INJURY. MAKE SURE THE FILTER VESSEL ARE FULLY FILLED THE WATER BEFORE STARTING UP THE PUMP OR IT WILL CAUSE THE PUMP DAMAGED. 4. Once water flow is steady out the waste line, run the pump for at least 2 minutes. The initial back-washing of the filer is recommended to remove any impurities of fine sand particles in the sand media. 5. Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear----about 1/2 to 1 minute. Turn pump off, set valve to FILTER position and restart pump. Your filter is now operating in the normal filter mode, filtering particles from the pool water. NOTES: 1. Note the initial pressure gauge reading when the filter is clean. (it will vary from pool depending upon the pump and general piping system). As the filter removes dirt and impurities from the pool water, the accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge reading is 8-10 PSI higher than the initial clean pressure you noted, it is the time to backwash (clean) the filter. 2. IMPORTANT: To prevent unnecessary strain on piping system and valving, always shut off pump before switching filter control valve position. 3. To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly. FILTER CONTROL VALVE FUNCTIONS: FILTER - Set valve to FILTER for normal filtering. Also use for regular vacuuming. BACKWASH For cleaning filter. When filter pressure gauge rises 8-10 PSI above start-up (clean pressure): Stop the pump, set valve to BACKWASH. Start pump and backwash until water in sight glass is clear. Approximately 2 minutes or less depending on dirt accumulation. Proceed to RINSE. RINSE After backwashing, with pump off, set valve to RINSE. Start pump and operate for about 1/2 to 1 minute. This ensures that all dirty water from backwashing is rinsed out of the filter to waste, preventing possible return to the pool. Stop pump, set valve to FILTER and start pump for normal filtering. WASTE To bypass filter for draining or lowering water level and for vacuuming heavy debris directly to waste.

Parts Listing Ref. No. Part No. Description QTY 1 98100-001 4-Way Valve 1 2 98101-001 Flange clamp 1 3 98102-001 O-ring 1 4 98103-001 Filter Tank 1 5 98104-001 Filter Assembly 1 6 98105-001 Drain plug 1 7 98106-001 sand filter support 1 8 98107-001 Screw and Nut 4 9 98108-001 O-ring 5 10 98109-001 Hose Adaptor 5 11 98110-001 Hose Clamp 2 12 98111-001 1 1/4 x 14 hose 1 13 98112-001 30GPM Pump 1 14 98113-001 Neck Fitting 1 15 98114-001 Pressure gauge 1 16 98115-001 Plug W/o-ring 1 1/2 1 17 98116-001 Basket 1

Limited Warranty For one (1) year from the date of purchase, manufacturer will repair or replace, at its option, for the original owner any parts of its filters ( Product ) which are found upon examination to be defective in materials or workmanship. This Limited Warranty covers parts only for a period of one (1) year. Please call 1-877-278-2797 for instructions. Be prepared to provide a receipt, the model number and serial number when exercising this limited warranty. Purchaser must pay all transportation charges on Products or parts submitted for repair or replacement. All non-warranty service charges are the responsibility of the original owner. Failure to pay for non-warranty service charges will void this Limited Warranty. This Limited Warranty does not cover Products that have been damaged as a result of accident, freezing, abuse, misuse, neglect, improper installation, improper maintenance or failure to operate in accordance with written instructions. All maintenance and service must be performed by service agents approved. Any unauthorized alteration or repairs will void this Limited Warranty. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer s customers for such damages. This Limited Warranty does not include freight charges for equipment or component parts, to and from the factory, services such as maintenance or inspection, repair or damage due to negligence such as freezing conditions, incorrect installation, nor acts of God. The liability shall not exceed the repair or replacement of defective parts under this Limited Warranty. This Limited Warranty also does not include unnecessary service calls due to erroneous operational reports, external valve positions, or electrical service. If a nonwarranty service call is made, and the homeowner is unwilling to pay for the service call, this Limited Warranty will be voided. This Limited Warranty is voided if the product is repaired or altered by any persons or agencies other than those authorized. This Limited warranty applies only within the continental USA. For warranty outside the continental USA. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST present a copy of the purchase receipt at the time of service. Please call 1-877-278-2797 for service or return authorization and instructions. DO NOT MAIL THIS FORM. Use this form only to maintain your records. MODEL NO. SERIAL NO. INSTALLATION DATE