Capacitance Meter ( microfarad ) Model NCM-20 INSTRUCTION MANUAL

Similar documents
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Thyristor-controlled power supplies and battery chargers

User Manual for CH-PFC76810

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

13 Watt PORTABLE SOLAR POWER KIT

AutoRanging Digital MultiMeter

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

How To Use A Power Supply Unit (Upu)

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Manual Ranging MultiMeter

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

User Guide. Model Insulation Tester / Megohmmeter

Ground Resistance Clamp On Tester

Automatic Voltage Regulator User s Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Photovoltaic Solar Energy Unit EESFB

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

TMS TANK MANAGEMENT SYSTEM

INFRARED QUARTZ WALL HEATER

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Achat 115MA full-range speaker. user manual

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

instabus KNX / EIB System System E F G H

Operating Instructions

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Product Information Sheet UH28CS-12kV Hi Pot Tester

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Battery Power Inverters

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

How To Use A Cdm250 Digital Multimeter

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Kit Watt Audio Amplifier

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Achat 212 H-SUB passive subwoofer. user manual

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

WSD130 SOLDERING STATION

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

What is a multimeter?

Instruction manual. Electrobloc EBL 100-2

PowerGem Pro Uninterruptible Power Supply

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

How To Build A Low Voltage Capacitor Lvcp

Gemini II. Subwoofer System OWNERS MANUAL

LOXONE 12 Channel Amplifier

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Emergency lighting units EM powerled

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Manual. Solar Fountain Mobile Phone Charger

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Measurement of Capacitance

19 LED Tube Controller ORDERCODE 41003

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

12 Volt 30 Amp Digital Solar Charge Controller

OUTPUT CABLE CONNECTIONS:

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

User s Manual Before using the inverter, you need to read and save the safety instructions.

Current Monitoring Kit QUICK START GUIDE

UT202A Operating Manual. Contents

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Electronic Pressure Switch EDS 300

User Manual 1K/2K/3K Online UPS

Power Capacitor Units for improved power quality

DALI RC BASIC SO. Control unit Operating instructions

Powerware 5110 UPS User s manual

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

Current Monitoring Kit

Battery Chargers. Revised 8/00 Form Number FORM NO / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

Episode 126: Capacitance and the equation C =Q/V

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

Energy Management Energy Meter Type EM23 DIN

Power your CPAP machine no matter where your world takes you!

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

PART 1 - INTRODUCTION...

= V peak 2 = 0.707V peak

Uninterruptible Power Supply

Features, Benefits, and Operation

Transcription:

Capacitance Meter ( microfarad ) Model NCM-20 INSTRUCTION MANUAL

Capacitance Meter NCM-20 USER S MANUAL 1. GENERAL 1.1 Introduction 1.2 Commissioning 1.3 Technical Specification 1.4 Accessories 2. OPERATING INSTRUCTIONS 2.1 Introduction 2.2 Charging 2.3 Calibration 2.4 Measurements 3. PRINCIPLE OF OPERATION 3.1 Display Unit 3.2 Generator Unit 4. MAINTENANCE 4.1 Introduction 4.2 Operation Check 4.3 Operations of Maintenance 4.4 Destruction and Recycling Page 2 of 13

Figure 1: Capacitance Meter with Accessories 1. GENERAL 1.1 Introduction Capacitance Meter NCM-20 is specially designed for capacitance measurements of rack-mounted capacitor units without the need of disconnecting any wiring between the units. Comparing the measured capacitances the units with blown fuses can be easily located in the bank. NCM-20 is battery operated and portable comprising separate display and generator units and is well suited for field use. The measured capacitance is displayed by a 3 ½-digit LCD display module on the display unit. The generator unit includes a build-in calibration capacitor. The meter with accessories is shown in Fig. 1. 1.2 Commissioning The meter is ready for use after calibration, provided there is enough charge in the batteries of Display and Generator Unit to carry out the measurements. The meter is calibrated using an internal calibration capacitor located in the generator unit. It is recommended to always charge the batteries before starting a major measurement procedure. Page 3 of 13

1.3 Technical Specification Connections: 1. Display Unit Battery charger 15VAC Current clamp for measurement of a capacitor unit 2. Generator Unit Voltage clips for supplying the measurement voltage 111.86 Hz 1.4 VAC to the bank, 4-wire measurement principle is used Battery charger 15VAC Supply capacity of the Generator Unit is 2000 μf Measuring ranges: Measurement voltage: 111.86 Hz, 1.4 VAC Range Display 2000 μf 0 1999 μf 200 μf 0 199.9 μf 20 μf 0 19.99 μf ± 1% of reading ± 2 digits Operating temperature range: -10 C +50 C Maintenance-free sealed lead-acid battery, Generator Unit: 12V 1.2Ah Yuasa NP1.2-12, Display Unit: 6V 1Ah Yuasa NP1-6 appr. 8 h with fully charged batteries depending on bank size Charging time: 10 16 h with discharged batteries 230VAC/15VAC 10.5VA, other primary voltages upon request Dimensions: Weights: Current clamp: Display unit: 170 x 80 x 115 mm Generator unit: 190 x 135 x 230 mm Casing: 450 x 350 x 250 mm Display unit: 0.95 kg Generator unit: 2.36 kg Casing: 4 kg Chauvin-Arnoux B08-PI: 2 kg Page 4 of 13

1.4 Accessories The meter is packed into an aluminium casing with the following accessories (Fig. 2): Display Unit Generator Unit Current clamp Measurement voltage clips Carrying strap for Display Unit Suspension strap for Generator Unit Battery charger 230VAC/15VAC Charger interconnection cable User s manual Figure 2: Meter casing Page 5 of 13

1 2 3 8 charge Capacitance Meter NCM-20 Display Unit I27.6 Capacitance [ µf ] power range + calibration - 7 4 5 6 Figure 3: Display Unit 1. Charge indicator 5. Range selector button 2. Power ON-OFF pushbutton 6. Calibration pushbutton 3. Calibration pushbutton 7. Current clamp connector 4. Display 8. Charger socket 1 2 3 CHARGER 1 CHARGER 2 15 Vac OFF ON OVERLOAD POWER VOLTAGE CLIPS 6 5 4 Figure 4: Generator Unit 1. Charge indicator 5. Charger sockets, 2. Overload indicators connected in parallel 3. Connector for voltage clips 6. Carrying handle, 4. Power switch capacitance label Page 6 of 13

2. OPERATING INSTRUCTIONS 2.1 Introduction The display and generator of the meter are implemented as separate battery-operated units which facilitates the easy use of the meter. The generator voltage clips are connected to the wiring of the capacitor bank and the generator can be placed to a suitable location using the suspension strap. The display unit can be hanged in the operator s neck with the carrying strap provided enabling measurement actions at difficult locations, e.g. when using ladders. 2.2 Charging It is a good practise always to start measurements by charging the batteries of Display and Generator Unit. The units can be simultaneously charged with the same charger by interconnecting the units with charger interconnection cable as presented in Fig. 5. Avoid storing the unit with discharged or halfdischarged batteries since a fully charged battery provides longer service time. A red led is provided on both units as charge indicator. The led is illuminated as charging is in progress and goes off when the battery gets fully charged. If the battery voltage in the Generator Unit is too low, the internal protection circuit prevents the operation of the Generator. Do not leave the Generator on after measurements because the it may deep-discharge the battery. Figure 5: Charging of the batteries Page 7 of 13

The charger can be also used separately with either of the units. There are two charger connector sockets on the side of the Generator Unit, one can be used for connection of the mains charger and the other for providing charge to the Display Unit using the interconnection cable provided. 2.3 Calibration Before starting measurements the display unit must be calibrated using the internal calibration capacitor for maximum measurement accuracy. When calibrating with the internal capacitor the range selection must be set to 200 μf (Fig. 3: button 5). The voltage clips must be connected to the generator unit during calibration to ensure the best calibration accuracy. The clips can be left unconnected, avoid short-circuiting the clips. The current clamp is switched around the carrying handle of the generator unit (see Fig. 6) and the reading of the display unit is adjusted with the calibration pushbuttons (Fig. 3: buttons 3 and 6) to match with the value marked on the top of the generator unit. Figure 6: Calibrating the meter Page 8 of 13

2.4 Measurements The measurement is started by connecting the voltage clips of the generator to the wires connecting capacitor units in parallel. Make sure that the capacitors to be measured are fully discharged before connecting the voltage clips as discharging the capacitor to the generator output may damage the generator. Please refer to the Instruction Manual of the capacitor bank Also avoid short-circuiting the clips as the internal protection fuse may blow. Make sure that both jaws of the clip make a good contact to the wires. The generator should be connected to the center of the parallel-connected capacitor units so that the current supplied by the generator will be equally divided between all units in the bank to maximize accuracy. Now the generator and display units can be switched on (Fig. 3: button 2 and Fig. 4: switch 4). Check that the both overload leds at the side of the Generator Unit (Fig. 4: 2) are off, otherwise the generator may be overloaded or in shortcircuit. The generator and display units should be kept powered for appr. 15 minutes before starting the actual measurements to let the measurement voltage and display to stabilize. After the warmup the calibration procedure presented in section 2.3 should be carried out. When the meter is calibrated, the actual measurements can take place. The capacitor unit is measured by selecting a proper measuring range (Fig. 3: 5) and placing the current clamp on the bushing of the capacitor unit and the value can be read out after some seconds as the reading is stabilized. The current clamp should be positioned as far as possible from wires to the lower part of the insulator as the current in wires can weaken the measuring accuracy. Page 9 of 13

Fig. 7 shows a practical measurement action. Fig. 7: Practical capacitor measurement Page 10 of 13

Fig. 8 shows a diagram of capacitance measurement. Figure 8: Diagram of capacitance measurement 3. PRINCIPLE OF OPERATION 3.1 Display Unit The capacitance is directly proportional to the AC current flowing through the capacitor to be measured provided the voltage across the unit is constant. The current is measured with a current clamp and converted into voltage in the display unit. The voltage signal is filtered with a narrow 111.86 Hz bandpass filter to remove the disturbing frequency components. The filtered signal is rectified and indicated with a digital DC voltmeter. The basic block diagram of the display unit is presented in Fig. 9. The voltage applied to the input of the voltmeter is scaled appropriately in proportion with the measured capacitance to obtain a direct capacitance reading in microfarads. Page 11 of 13

Figure 9: Block diagram of the Display Unit 3.2 Generator Unit The voltage required in capacitance measurement is generated with the Generator Unit. The power stage comprises a bridge-connected switching amplifier capable of feeding a considerably large capacitive load, max. 2000 μf. The output of the generator is 1.4 VAC with the frequency of 111.86 Hz. The frequency has been chosen so that it is properly off-tuned from the fundamental and harmonics of the mains frequency to facilitate good suppression of unwanted disturbing frequencies. The output voltage is stabilized so that the voltage drift is minimal making accurate measurements possible. The block diagram is presented in Fig. 10. Figure 10: Block diagram of the Generator Unit 4. MAINTENANCE 4.1 Introduction The capacitance meter is designed to require minimal maintenance and, when operated properly, its life expectancy is long. The most vulnerable part is the current clamp which should be handled with utmost care. Page 12 of 13

4.2 Operation check The operation of the meter can be checked with the following simple procedure: 1. Switch on the generator. Observe the two red indicator lights on the side panel (Fig. 4: 2). The other should light when switching the unit on and go out after a few seconds. If this happens, the generator is probably operational. Another method to check the operation of the generator is to measure the output voltage which should be around 1.4 1.5 VAC with the frequency of 111.86 Hz. The indicator lights can be on if the load is too high or in short-circuit. If the battery is discharged, the generator will not start, in this case charge the battery. 2. Switch on the display unit and clip the current clamp around the carrying handle of the generator as presented in section 2.3. The display should indicate a reading close to the capacitance of the calibration capacitor adjustable to the correct value with the calibration pushbuttons. 3. Switch off the generator. The display should decrease to zero. 4. If the display unit operates as described in 2. and 3., it is in working condition. 4.3 Operations of maintenance Generator Unit: If the output voltage of the unit is measured to be zero, the internal protection fuse is probably blown. Open the cover and check the fuse on the circuit board. Replace with a new one when required. The fuse rating is 6.3 x 32 mm 7 A, fast acting. Display Unit: There are no user-maintainable parts in the unit. Current clamp (concerns model Midori CT-65): The air gaps of the current clamp must be held clean. Dust and foreign particles can cause erraneous readings. The gaps can be cleaned e.g. by drawing a piece of paper through the gaps. No abrasive material, e.g. sandpaper must not be used. The thin plates can bend easily and the clamp will not close properly. In this case the plates must be carefully realigned in order to close without using excessive force. Opening and closing can be facilitated by a squeeze of lubricating oil (CRC-56 or equivalent) between the plates. Check regularly the condition of all the cables of the meter. If the meter has got wet e.g. in field use, do not store it tightly closed but first let the moisture to evaporate. If the meter is to be stored for a long period of time, the batteries must be fully charged prior to storing. 4.4 Destruction and recycling The cases of the Display and Generator units are made of ABS plastic and can be recycled or destructed in accordance with the local regulations. The carrying case is made mostly of aluminium and can be recycled. The printed circuit boards contain no recyclable parts and must be disposed as electronics waste. The batteries are to be treated as hazardous waste and must be disposed accordingly.