PERFORMANCE, RELIABILITY AND SPEED Increase quality and efficiency with energy efficient, user friendly control of motors from 0.37 to 75 kw. The VLT AutomationDrive FC 360 is a general purpose drive that provides precise and efficient motor control in a wide range of industrial applications. Built-in features help owners save space in installations, time in setup and effort in daily maintenance. The result is a powerful and versatile solution that increases process efficiency and quality in a cost-efficient package. Designed for challenging environments Using advanced coating and quality internal electronics protection, the FC 360 has the rugged characteristics demanded by the textile, plastics, rubber, food, beverage and building materials industries. Maximize productivity An easy to use control panel in English and Chinese saves valuable time in commissioning and maintaining the drive, and enables owners to maximize uptime and save energy. 3
The basic design profile of the VLT AutomationDrive FC 360 reduces the number of code numbers needed for ordering, making the process easier Built on the success of the tried and tested VLT platform that Danfoss developed and launched in the 1960 s, the VLT AutomationDrive FC 360 shares the same technical heritage as the popular and versatile VLT AutomationDrive FC 300 series. Developed to meet a general purpose operation profile the drive lacks the expandability of its larger sibling, but still delivers powerful performance out of the box. Due to the fact that all Danfoss frequency converters follow the same basic design and operating principle, existing owners and users of VLT drives will instantly feel at home when operating the VLT AutomationDrive FC 360. Compact design for easy installation Delivered as standard with IP 20 protection. The compact, lightweight design helps optimize panel space as a result of side-by-side mounting with zero clearance. Save time on setup Easy parameter setup makes the path to energy savings both short and simple, and can be carried out with an enhanced numeric LCP or graphical control panel that supports English and Chinese. Targeted application guides walk users through the setup of a new application and ensure accuracy and precision. 4
HIGH RELIABILITY Coated Printed Circuit Boards Special high level 3C3 Printed Circuit Board (PCB) coating as standard provides higher reliability in harsh environments to prevent premature failures and downtime. The lifetime of the drive is also increased as a result of the IED61721-3-3 conformal coating. 55 C Working Temperature VLT AutomationDrive FC 360 is designed to operate at 45-50 C ambient temperature at full load (depending on model) and 55 C with derating. This means there is no need to install extra cooling equipment or oversize the drive, resulting in cost savings. Efficient heat management A unique cooling concept ensures that there is no forced air flow over the electronics. This reduces the risk of downtime, while strengthening stability in daily operation. By preventing dust and particles from accumulating on the small internal components and legs, the risk of short circuits is significantly reduced, especially in humid environments. COATED PCB The VLT AutomationDrive FC 360 is delivered with a 3C3 class coated PCB as standard to strengthen reliability. EASY CLEANING An easy to remove fan of the drive makes it easy to keep dust from affecting the drive s ventilation. 5
450 kg force at 0.6 Hz. The high torque performance of a 0.75 kw VLT AutomationDrive FC 360 fully meets the demands for tensile testing at Samuya Technocrates in India. Reduced Harmonics A built-in DC choke reduces harmonics to less than 43% (ThiD) and significantly extends the lifetime of the DC capacitor. 6
Optimized for industrial processes Extruders Escalators Winders Material Handling Centrifuge separators Pumps Fans Smart Logic Control Smart Logic is a simple and clever way to keep the drive, motor and application working together. The smart logic controller monitors a specific event, and when it occurs, it triggers a predefined action which is monitored for 20 steps, before returning to step 1. The Smart Logic Controller can monitor any parameter that can be defined as true or false, providing users with significant freedom to tailor the control strategy to their specific needs. This includes digital commands and logic expressions, where sensor outputs can influence operation using parameters such as temperature, pressure, torque, flow, time, load, frequency, voltage, and others, combined with the operators >, <, =, and and or as logical statements. Expand with control and feedback modules Fieldbus communication in VLT AutomationDrive FC 360 is integrated in the control card. In addition, the drive can be expanded with options for additional control and encoder feedback. With the VLT Encoder Input MCB 102 and VLT Resolver Input MCB 103 the VLT AutomationDrive FC 360 can receive encoder feedback from either a motor or a process. Time saving setup VLT Motion Control Tool MCT 10 The VLT AutomationDrive FC 360 can be configured and monitored with Danfoss own VLT Motion Control Tool MCT 10 software. This provides plant managers with a comprehensive overview over the system at any point in time and a high level of flexibility in configuration and monitoring. MCT 10 is a windows based engineering tool with a clearly structured interface that provides an instant overview of all the drives in a system of any size. The software runs under Windows and enables data exchange over a traditional RS 485 interface or fieldbus (PROFIBUS, PROFINET). Parameter configuration is possible both online and offline, and the software can be configured to link to the system s electrical diagrams or operating manuals. This helps to reduce the risk of incorrect configuration while offering fast access to troubleshooting. Maximise uptime High level 3C3 printed circuit board as standard Max. ambient temperature without derating: 45-50 C (depending on model). No forced air over electronics reduces contamination risk Removable fan enables fast and easy cleaning 7
INTEGRATED FEATURES The VLT AutomationDrive FC 360 is designed to provide maximum uptime and reliability in a wide range of environments. Built-in Brake Chopper A built-in brake chopper up to 22kW saves money and panel space. Pulse Input as Speed Reference VLT AutomationDrive FC 360 offers the capability to convert pulse input as a speed reference, avoiding the need to purchase an analog signal module for PLC. 2 Central Winder FC 360 supports central winder functionality, eliminating the need for a special module in the programmable logic control (PLC). 1 6 3 Built-in PID Controller The built in PID controller calculates an error value as the difference between a measured process variable and a desired setpoint. 5 4 8
1 Designed for use in ambient temperatures up 45-50 C without derating. Max. ambient temperature 55 C 2 No forced air over PCB 7 9 3 Class C3C coated components for increased reliability in harsh environments (IEC 6072 1-3-3) 4 Removable fan 5 EMC compliant meets class C3 with limit A2 (EN 55011) as standard 6 Built-in brake chopper up to 22 kw 7 Fieldbus embedded in control card (Profibus, Profinet) 8 8 I/0 number and functions - 7DI / 2AI / 2AO / 2 DO - Pulse input as speed reference - Pulse feedback and 24V encoder feedback - 24V (100 ma) - 12V 9 Display options - Enhanced numeric LCP - Graphic LCP supports English and Chinese - Blind cover * Full automatic motor adaptation (AMA) optimizes compatibility between frequency converter and motor in VVC+ mode * Built-in Smart Logic Controller * RFI Swtich * Not visible on picture 9
SPECIFICATIONS (Basic unit without extensions) Main supply (L1, L2, L3) Supply voltage 380 480 V -15%/+10% Supply frequency 50/60 Hz ±5% Displacement power factor (cos ф) > 0.98 Switching on input supply L1, L2, L3 0.37-7.5 kw maximum 2 times/min. 11-75 kw maximum 1 time/min. Harmonic disturbance Meets EN 61000-3-12 Output data (U, V, W) Output voltage Output frequency Switching on output Ramp times 0 100% of supply voltage 0-500 Hz 0-200 Hz under VVC+ Mode Unlimited 0.05-3600 sec Digital inputs Programmable digital inputs 7 Changeable to digital output 2 (Terminal 27,29) Logic PNP or NPN Voltage level 0 24 V DC Maximum voltage on input 28 V DC Input resistance, Ri Approx. 4 kω Scan interval 1 ms * 2 can be used as digital outputs Analogue output Programmable analogue outputs Current range at analogue output Max. load to common at analogue output (clamp 30) Accuracy on analogue output Control card RS485 interface Max. load (10 V) Max. load (24 V) 2 0/4 20 ma 500 Ω Max. error: 0.8 % of full scale Up to 115 kbaud 15 ma 100 ma Relay output Programmable relay outputs 2 Max. terminal load (AC) on 1-3 (break), 1-2 (make), 250V AC, 3 A 4-6 (break) power card Max. terminal load (AC) on 250V AC, 3 A 4-5 (make) power card Min. terminal load on 1-3 (break), 1-2 (make), 250V AC, 0.2 A 4-6 (break), 4-5 (make) power card Analog inputs Analogue inputs 2 Modes Voltage or current Voltage level Current level Accuracy of analog inputs Pulse/encoder inputs Programmable pulse/ encoder inputs Voltage level Pulse input accuracy (0.1 1 khz) Encoder input accuracy * Utilize some of the digital inputs 0 to +10 V (scaleable) 0/4 to 20 ma (scaleable) Max. error 0.5% of full scale 2/1 0 24 V DC (PNP positive logic) Max. error: 0.1% of full scale 4Hz-32kHz Surroundings/external Enclosure Vibration test Max. relative humidity Ambient temperature Galvanic isolation of all Aggressive environment Fieldbus communication Standard built-in Fieldbus built-in control card variants IP20 1.0 g 5-95% (IEC 721-3-3; Class 3K3 (noncondensing) during operation max. 55 C with derating I/O supplies according to PELV Class 3C3 FC Protocol Modbus RTU PROFIBUS PROFINET Digital outputs Programmable digital/pulse outputs Voltage level at digital/frequency output Max. output current (sink or source) Maximum output frequency at frequency output Accuracy on frequency output * Utilize 2 digital inputs 2 0 24 V DC 40 ma 4Hz to 32 khz Max. error: 0.1% of full scale 10
CONNECTION EXAMPLES The numbers represent the terminals on the drive 3 Phase power input +10V DC 91 (L1) 92 (L2) 93 (L3) 95 PE 50 (+10 V OUT) 3) Switch Mode Power Supply 10Vdc 24Vdc 15mA 100mA + - + - (U) 96 (V) 97 (W) 98 (PE) 99 (-UDC) 88 (+UDC) 82 (BR) 81 Brake resistor Motor 130BC438.11 0/-10V DC - 0/4-20 ma 0/-10V DC - 0/4-20 ma 53 (A IN) 54 (A IN) relay1 03 02 240V AC, 2A 55 (COM A IN) 12 (+24V OUT) 01 relay 2 2) 06 18 (D IN) P 5-00 24V (NPN) 0V (PNP) 05 04 240V AC, 2A 19 (D IN) 20 (COM D IN) 27 (D IN/OUT) 24V 24V (NPN) 0V (PNP) 24V (NPN) 0V (PNP) 1 2 ON (A OUT) 45 (A OUT) 42 ON=Terminated OFF=Open Analog Output 0/4-20 ma 29 (D IN/OUT) 0V 24V 24V (NPN) 0V (PNP) 5V S801 0V 32 (D IN) 33 (D IN) 0V 24V (NPN) 0V (PNP) 24V (NPN) 0V (PNP) RS-485 Interface (N RS-485) 69 (P RS-485) 68 (COM RS-485) 61 RS-485 31 (D IN) 24V (NPN) 0V (PNP) (PNP) = Source (NPN) = Sink 1 Built-in braking chopper available from 0.37-22 kw 2 Relay 2 is 2 pole for J1-J3 and 3 pole for J4-J7. Relay 2 of J4-J7 with terminal 4,5,6, same NO/NC logic as Relay 1. 3 Dual DC choke in 30-75 kw 4 Switch S801 (bus terminal) can be used to enable termination on the RS-485 port (terminals 68 and 69). The diagram shows the port terminals of the VLT AutomationDrive FC 360. The numbers indicated refer to the terminal numbers of the drives. Users can set the mode of the analogue inputs 53 and 54 by setting software parameters. The FC 360 features a RS485 interface as standard. The RS485 terminations are integrated in the drive (S801). PROFIBUS DP or PROFINET can be specified by configuring different control cassettes when ordering. To switch from NPN to PNP logic for the digital signals, use parameter 5-00. 11
POWER, CURRENTS AND ENCLOSURES T4 380 480 V (High overload) T4 380 480 V (Normal overload) FC 360 kw Amp. 380-439V 440-480V Dimensions [mm] Frame size J1 J2 J3 J4 J5 380-480 V Power size [kw] 0.37-2.2 3.0-5.5 7.5 11-15 18.5-22 Dimensions [mm] B b C A a D IP 20 /Chassis FC 360 kw Amp. 380-439V 440-480V HK37 0.37 1.2 1.1 HK55 0.55 1.7 1.6 HK75 0.75 2.2 2.1 H1K1 1.1 3.0 2.8 J1 H1K5 1.5 3.7 3.4 H2K2 2.2 5.3 4.8 H3K0 3.0 7.2 6.3 H4K0 4.0 9.0 8.2 J2 H5K5 5.5 12 11 H7K5 7.5 15.5 14 J3 H11K 11 23 21 Q11K 11 23 21 J4 H15K 15 31 27 Q15K 15 31 27 H18K 18 37 34 Q18K 18 37 34 J5 H22K 22 42.5 40 Q22K 22 42.5 40 IP 20/Chassis J4 J5 130BC449.10 12 Height A 210 272.5 272.5 317.5 410 Width B 75 90 115 133 150 Depth C (with option B) 168 (181) 168 (181) 168 (181) 245 (258) 245 (258) Mounting holes a 198 260 260 297.5 390 b 60 70 90 105 120 Mounting screw M4 M5 M5 M6 M6
ORDERING TYPE CODE FOR VLT AutomationDrive FC 360 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] FC-360 X SXX X X [1] Application 360 VLT AutomationDrive FC 360 [2] Power Size HK37 HK55 HK75 H1K1 H1K5 H2K2 H3K0 H4K0 H5K5 H7K5 H11K/ Q11K H15K/ Q15K H18K/ Q18K H22K/ Q22K See ratings data on page 11 for power ratings [3] AC Line Voltage T4 [4] Enclosure 3 x 380/480 V AC (High overload) 3 x 380/480 V AC (Normal overload) For cabinet mounting: E20 IP 20/Chassis [5] RFI Filter (EN 55011) H2 RFI-Filter class A2 [6] Braking X No brake IGBT B Built-in brake IGBT * 0.37-22kW built-in; 30-75kW not [7] Display (Local Control Panel) X No LCP, blind cover * Following accessories available: NLCP, GLCP and blind cover [8] Conformal Coating (IEC 721-3-3) C Conformal coating on all PCBs [9] Mains Input D Load sharing terminals [10] Cable X Standard Cable Entry [13] Fieldbus embedded in control cassette AX No fieldbus option A0 PROFIBUS AL PROFINET [14] B Option (Application) BX No application option * VLT Encoder Input MCB102 and VLT Resolver Input MCB 103 available as accessories Please note that not all combinations are possible. Find help for configuring your drive with the online configurator at driveconfig.danfoss.com Based on your selection, Danfoss manufactures the desired VLT AutomationDrive FC 360 to your specification. You will receive a fully assembled frequency converter, tested under full load conditions. 13
380 480 VAC Enclosure IP 20 J1 J2 J3 HO HK37 HK55 HK75 H1K1 H1K5 H2K2 H3K0 H4K0 H5K5 H7K5 Typical Shaft Output [kw] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 Typical Shaft Output at 460 V [HP] 0.5 0.75 1.0 1.5 2.0 3.0 4.0 5.5 7.5 10.0 Output Current (3 x 380 440 V) Continuous [A] 1.2 1.7 2.2 3.0 3.7 5.3 7.2 9.0 12 15.5 Output Current (3 x 441 480 V) Output Power (400 V AC) Output Power (460 V AC) Max. cable size (Mains, motor, brake and load sharing) Max. Input Current (3 x 380 440 V) Max. Input Current (3 x 441 480 V) Continuous [A] 1.1 1.6 2.1 3 3.4 4.8 6.3 8.2 11 14 Intermittent [A] 1.9 2.7 3.5 4.8 5.9 8.5 11.5 14.4 19.2 24.8 Continuous [kva] 0.8 1.2 1.5 2.1 2.6 3.7 5.0 6.2 8.3 10.7 Continuous [kva] 0.9 1.3 1.8 2.5 2.8 4.0 5.2 6.8 9.2 11.6 [mm 2 ] ([AWG]) 4 mm 2 Continuous [A] 1.2 1.6 2.1 2.6 3.5 4.7 6.3 8.3 11.2 15.1 Continuous [A] 1.0 1.2 1.8 2.0 2.9 3.9 4.3 6.8 9.4 12.6 Intermittent [A] 1.9 2.6 3.4 4.2 5.6 7.5 10.1 13.3 17.9 24.2 Max. pre-fuses [A] 10 25 32 Environment Estimated power loss at rated max. load [W] 52.4 113.9 150.8 Weight IP 20 [kg] 2.3 2.3 2.3 2.3 2.3 2.5 3.6 3.6 3.6 4.1 Efficiency 97,6% 97,9% 98% Enclosure IP 20 J4 J5 IP 20 J4 J5 HO H11K H15K H18K H22K NO Q11K Q15K Q18K Q22K Typical Shaft Output [kw] 11 15 18 22 11 15 18 22 Typical Shaft Output at 460 V [HP] 15 20 25 30 15 20 25 30 Output Current (3 x 380 440 V) Continuous [A] 23 31 37 42.5 23 31 37 42.5 Output Current (3 x 441 480 V) Output Power (400 V AC) Output Power (460 V AC) 6Max. cable size (Mains, motor, brake) Max. Input Current (3 x 380 440 V) Max. Input Current (3 x 441 480 V) Continuous [A] 21 27 34 40 21 27 34 40 Intermittent [A] 34.5 46.5 55.5 63.8 25.3 34.1 40.7 46.8 Continuous [kva] 15.9 21.5 25.6 29.5 Continuous [kva] 17.5 22.5 28.3 33.3 [mm 2 ] ([AWG]) Continuous [A] 22.1 29.9 35.2 41.5 Continuous [A] 18.4 24.7 29.3 34.6 Intermittent [A] 33.2 44.9 52.8 62.3 16 mm 2 16 mm 2 Max. pre-fuses [A] 50 80 Environment Estimated power loss at rated max. load [W] 331.5 457.7 Weight IP 20 [kg] 9.4 9.5 12.3 12.5 9.4 9.5 12.3 12.5 Efficiency 97.8% 97.9% 14
OPTIONS AND ACCESSORIES VLT Control Panel LCP 21 The numerical control panel offers an excellent MMI interface to the drive. Status messages Quick menu for easy commissioning Parameter setting and adjusting Hand-operated start/stop function or Automatic mode select Reset function Ordering number: 132B0255 VLT Brake Resistors MCE 101 Energy generated during braking is absorbed by the resistors, protecting electrical components from heating up. Danfoss brake resistors are optimized for the FC-series and general versions for horizontal and vertical applications are available. Enclosure protection as IP20 and up to IP65 Build-in thermo switch Versions for vertical and horizontal mounting UL-recognized only types for vertical mounting VLT Encoder Input MCB 102 A universal option for connection of encoder feedback from either a motor or a process. Feedback for asynchronous or brushless servo (Permanent Magnet) motors. Encoder module supports: Incremental encoders SinCos encoders as Hyperface Power supply for encoders RS422 interface Connection to all standard 5 V incremental encoders Spring-loaded connection VLT Resolver Input MCB 103 Supports resolver feedback for asynchronous or brushless servo (Permanent Magnet) motors. Primary Voltage...2 8 Vrms Primary Frequency...2.0 khz 15 khz Primary current max...50 ma rms Secondary input voltage...4 Vrms Spring loaded connection Other accessories VLT Blind Cover Ordering number: 132B0262 VLT Numeric LCP IP55 Mounting Kits Ordering number: 132B0102 VLT Decoupling for frame size J2&J3 Ordering number: 132B0259 VLT Decoupling for frame size J4&J5 Ordering number: 132B0260 VLT Decoupling for frame size J1 Ordering number: 132B0258 15
What VLT is all about Danfoss VLT Drives is the world leader among dedicated drives providers and still gaining market share. Environmentally responsible VLT products are manufactured with respect for the safety and well-being of people and the environment. All frequency converter factories are certified according to ISO 14001 and ISO 9001 standards. All activities are planned and performed taking into account the individual employee, the work environment and the external environment. Production takes place with a minimum of noise, smoke or other pollution and environmentally safe disposal of the products is pre-prepared. UN Global Compact Danfoss has signed the UN Global Compact on social and environmental responsibility and our companies act responsibly towards local societies. Impact on energy savings One year s energy savings from our annual production of VLT drives will save the energy equivalent to the energy production from a major power plant. Better process control at the same time improves product quality and reduces waste and wear on equipment. Dedicated to drives Dedication has been a key word since 1968, when Danfoss introduced the world s first mass produced variable speed drive for AC motors and named it VLT. Twenty five hundred employees develop, manufacture, sell and service drives and soft starters in more than one hundred countries, focused only on drives and soft starters. Intelligent and innovative Developers at Danfoss VLT Drives have fully adopted modular principles in development as well as design, production and configuration. Tomorrow s features are developed in parallel using dedicated technology platforms. This allows the development of all elements to take place in parallel, at the same time reducing time to market and ensuring that customers always enjoy the benefits of the latest features. Rely on the experts We take responsibility for every element of our products. The fact that we develop and produce our own features, hardware, software, power modules, printed circuit boards, and accessories is your guarantee of reliable products. Local backup globally VLT motor controllers are operating in applications all over the world and Danfoss VLT Drives experts located in more than 100 countries are ready to support our customers with application advice and service wherever they may be. Danfoss VLT Drives experts don t stop until the customer s drive challenges are solved. Danfoss Automatic Controls Management Co., Ltd, 20th Floor, Block C, Hi-Tech building, 900 Yi Shan Road, 200233 Shanghai, China Tel. +86 021 6151 3000, Fax +86 021 6151 3100, www.danfoss.com.cn, E-mail: shanghai@danfoss.com DKDD.PB.304.A1.02 VLT is a trademark of Danfoss A/S PE-MMSC 2013.01