On/Off Switch. Warning light. WISE System Architecture



Similar documents
Smart Solutions for Remote Monitoring and Alarms Active Ethernet I/O with Active OPC Server

3G Cellular RTU Solutions. Activate Your Remote Monitoring Application

Application Guide Guardian Over the NET Server Room Solution

Semaphore T BOX Applications in Data Center Facilities

WinCon Programmable Automation. Controller

Why Can t We Be Friends?

AutoLog ControlMan. Remote Monitoring & Controlling Service

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

WISE-4000 Series. WISE IoT Wireless I/O Modules

Touch HMI Devices. The Best Choice for Building/Factory/Machine/Home Automation. Introduction. Features. Touch HMI Devices.

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

4-CH Hybrid Digital Video Recorder

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW. EVEN MORE data acquisition and test stand automation

SCADA and Monitoring for Solar Energy Plant

SNMP I/O Devices Make Monitoring Environmental Conditions Easy. Austin Lin Product Manager Wayne Chen Technical Service Moxa Inc.


Integrated Building Management and Security System. Building Automation & Security.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

securityprobe 5E Standard

Optimize your simple machines... Modicon M218 Selection Guide

Simplify Data Acquisition with a Built-in LXI Web Server

Ultimate Server Client Software

CenterMind G+ Smart and Proactive Environment Monitoring

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

VS-100. PoE. H.264 PoE Video Server. H.264 Compression H.264 DI/DO. Compression Rate Comparison MJPEG MPEG4 H.264.

Monitoring & Control of Small-scale Renewable Energy Sources

HMS Industrial Networks. Putting industrial applications on the cloud

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

SMS GSM Alarm Messenger

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Passion for Innovation

Complete SCADA solution for Remote Monitoring and Control

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Comprehensive Data Center Energy Management Solutions

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

Comprehensive Data Center Energy Management Solutions

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

HMS Industrial Networks

Wireless solutions for water and wastewater management

Flexy-ble M2M router for remote access and data services. Industrial M2M Router.

How To Use Netbiter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Modbus Server SAMSUNG Air Conditioners

Tk20 Network Infrastructure

Introducing Tripp Lite s PowerAlert Network Management Software

Technical Training Module ( 30 Days)

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

H.264 Internet Video Server

IntesisBox Modbus Server SAMSUNG Air Conditioners

Process Alarm Solutions

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

Process Control and Automation using Modbus Protocol

Integrated Building Management and Security System. Building Automation & Security.

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

Electronic Control Devices The European Product Catalogue 2007

PE6108/PE6208/PE8108/PE8208

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Technical Information POWER PLANT CONTROLLER

PN5212/PN5320/PN7212/PN7320

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

IP Video Surveillance

NXL Series Inverters. HVAC Inverters made simple

Medical Vacuum Systems-PXMI

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Premium Server Client Software

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Technical Overview CM-16 Climate Monitor. Get yours direct at:

You were seeking a protocol translator. Eaton delivered a vital data flow processor.

IVS-200 Enter: intelligent "Enter" video analytics server. Model: IVS-200 Enter

Application/Connection Examples

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

HyperAccess Access Control System

Electronic Control Devices The European Product Catalogue 2007

securityprobe5es -X20

Intelligent Vibration Monitoring

Power & Environmental Monitoring

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

Remote monitoring & control solutions for cathodic protection rectifier

M2M/IoT Solutions.

Easy and efficient asset management for your business

AKCess Pro Server Management Software

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

ENC Enterprise Network Center. Intuitive, Real-time Monitoring and Management of Distributed Devices. Benefits. Access anytime, anywhere

Transcription:

2AR Groupe Rg2i Groupe 2AR Interfaces pour l informatique industrielle Produits et Solutions en Communication Industrielle Acquisition de Données et Transport de l Information 5 Rue Edmond Charpentier - 42000 Saint Etienne - France Tél: +33 (0) 4 77 92 03 56 - Fax: +33 (0) 4 77 92 03 57 Internet: http://www.rg2i.fr Email: info@rg2i.fr

WISE Introduction WISE (Web ) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. System Architecture IP Camera Email SMS Ethernet Ethernet Ethernet Control Center IF-THEN-ELSE Rule Engine Ethernet Rule Editing I/O and Sensors Pulse/Frequency On/Off Switch Warning light RTD sensor Thermometer WISE System Architecture Through Web browser, users can access Web server on WISE controllers to perform tasks such as logic rule edition and download. An IF-THEN-ELSE rule engine will be set up to manage and deploy logic rules for controllers. The rule engine will check whether the rules are valid or not and determine the execution of actions under specific conditions, for examples: setting up I/O channel values, perform Timer/Schedule tasks, sending Email/SMS message or sending CGI command under a specific condition. WISE series controller also provides wide range of hardware platforms and I/O modules that enable to support various I/O functions. It allows users to find best solutions to meet their requirements. In addition, through Modbus TCP/RTU protocol, SCADA package enables to control and monitor I/O channel or system status on WISE controller in real time. WISE-580x even provides more supports in I/O functions. It allows to connecting with a wide range of the XW-Board, I-7000 remote I/O modules and Modbus RTU slave modules; enables to freely choose the most suitable I/O modules. With the microsd card, it provides Data Logger function to real-time record the I/O channel data of the controller and allows to send the data files by FTP or Email at a scheduled time to the control center for further administration management or data analysis. Applications Building Automation Factory Automation Machine Automation Remote Maintenance/Diagnosis Environment Monitoring Facility Management

Features IF-THEN-ELSE logic rules execution ability WISE controller features an IF-THEN-ELSE logic rule engine, it offers up to 36 IF-THEN-ELSE rules for users to set up the logic content. After completing rule edition and downloading rules to the WISE controller, the rule engine will loop execute the rules in accordance with the execute order under specific conditions. No extra software tool is required WISE HMI interface runs on regular Web browsers. To edit control logic, it only requires a browser to connect to the Web server on WISE controller. No extra software tool installation is needed on the target PC. WISE Web User Interface No more programming WISE provides user-friendly Web UI pages for editing control logic on the controllers. It enables to implement logic edition by a few clicks on the mouse to set up and deploy logic rules without writing a single line of code. Offer various options for I/O channel settings WISE offers various options for I/O channel settings; for example: noise filter for DI signals, deadband setting for AI signals, linear scale setting, temperature degree in Celsius or Fahrenheit setting, power on value setting for DO channel, pulse output setting and DI/DO counter setting, etc. Click and get done! Provide Timer and Schedule operation WISE features Timer and Schedule functions: It allows user to schedule specific date or time for control logic execution, or perform specific tasks such as time delay. With calendar user interface provided, Schedule setting can be more efficient and flexible. CGI Command sending for surveillance system integration WISE provides CGI commands sending function. It provides integrated access to a wide variety of Web devices and surveillance systems. Recipe function for grouping a series of actions In addition to 3 THEN actions and 3 ELSE actions settings WISE provides for each rule, Recipe function is provided for easily grouping a series of actions. A series of actions can be saved in a Recipe action and will be executed when the IF- THEN-ELSE condition is matched. WISE Schedule setting page

Advanced P2P function between WISE controllers (WISE-71xx, WISE-790x and WISE-4000 only) WISE offers P2P function that enables WISE controllers to directly communicate with other remote WISE controllers on networks. The controllers can freely share their status information such as I/O channel value, DI/DO counter or Internal Register to each others. The P2P operations can be incorporated into WISE logic rules as condition statements or action statements for condition evaluation criteria or action executions. Real-time alarm notification & remote monitoring via SMS or Email WISE supports SMS and Email functions for real-time message notification function. The message sending action can be added to the logic edition as part of logic control to provide real-time message notification to the related personnel when an event occurs. Advanced P2P function Seamless integration with SCADA WISE supports Modbus TCP/RTU protocol for users to perform realtime monitoring and control of the controllers. Through Modbus TCP/ RTU, it allows SCADA package seamlessly integrate with WISE and enables total solutions for remote monitoring and control. Real-time receive and execute SMS command (WISE-5801 only) WISE-5801 is equipped with SMS command receiving function. It allows to receive the SMS commands sent by specific phones numbers to perform tasks such as real-time I/O channel value monitoring, I/ O channel value modification and logic rules execution (triggered by SMS), etc. Support Modbus RTU slave module (WISE-580x only) WISE-580x allows to connect with devices that support Modbus RTU protocol for I/O monitoring. The ability to connect with Modbus RTU slave devices enables the flexibility and scalability for system implementation and allows to meet various requirements of the applications from the clients. WISE-5800 System Architecture Email function SMS alarm notification Ethernet Ethernet RS-232 for Serial HMI Control Center Rule Editing IP Camera E-mail Data Logger Local Bus for XW-Board RS-485 for I-7000 Series and Modbus RTU Slave Devices Analog I/O Module Temperature Measurement Module Digital I/O Module Relay Output Module Counter/ Frequency Module 0101001 Analog Digital Pulse/Frequency RTD Sensor Thermometer Relay Output ON/OFF Switch Warning Light

Data Logger operation (WISE-580x only) With the microsd card, WISE-580x provides Data Logger function to real-time record the I/O channel data of the controller and sends the data files by FTP or Email to the control center for further administration management or data analysis. Active I/O sending function (WISE-580x only) In addition to the Modbus TCP/RTU slave function that enables SCADA software (or HMI device) to poll the I/O channels data of the WISE controller, now WISE-580x provides Active I/O sending function. Based on the Active I/O sending function, WISE-580x allows to send the I/O channels data of the controller actively to SCADA software (or HMI device) by event trigger (I/O channel data changed) or periodic cycle. This function will improve the efficiency of the data communication between WISE controller and SCADA software (or HMI device). Data Logger function Please note: The SCADA software (or HMI device) must provides Modbus TCP slave function to receive the I/O channels data sent by WISE. DI Channel AI Channel Internal Register DI Counter DO Counter Timer Schedule P2P Rule Status IF Conditions ON, OFF, ON to OFF, OFF to ON, Change =, >, <, >=, <= (value) =, >, <, >=, <= (value), Change Timeout, Not Timeout In Range, Out of Range DI, AI, DI counter, DO counter, IR Enable, Disable WISE IF-THEN-ELSE Rule Engine Active I/O sending function THEN / ELSE Actions DO Channel ON, OFF, Pulse Output AO Channel Internal Register Change the value DI Counter DO Counter Reset Timer Schedule Start, Reset SMS Email Send CGI Commands Recipe Execute P2P DO(On/Off), AO, IR Data Logger Start, Stop, One-Time Log Rule Status Enable, Disable The overview of IF-THEN-ELSE rule engine

WISE Web Application Story Tunnel Monitoring System The security maintenance in a tunnel is a tough work and it is time-sensitive. For it always requires to monitor a wide range of areas in the tunnel, if all monitoring jobs only rely on manual operations when a disaster happened, it might cause delays and lead to huge losses. WISE-5800 allows to connect to various I/O modules and is able to response to the emergency in real-time. In this case, the WISE-5800 controllers are installed in various segments in the tunnel and are connected to smoke/ temperature sensors, warning lights, sprinklers, ventilation fans and other equipments. The logic rules that in response to emergency situations could be pre-set in WISE-5800, and when smoke and high temperature are detected, the fire fighting procedures will be triggered; the sprinklers will be automatically turned on to put out the fire; the ventilation fans will be started to take away the smoke; and will turn on the warning lights and open the security doors to guide people in the tunnel away from the emergency scene. The related information will be gathered in back-end control center, and will send out notification to all controllers in all segments of the tunnel for traffic control and management. Greenhouse Automation Solution Greenhouse cultivation represents a very important role in modern agriculture. As the greenhouse usually is equipped with various high-tech equipments, management tend to be very complex. A fully automated greenhouse control systems bring obvious benefit such as labor saving, but far more i m p o r t a n t l y, i t e n a b l e s improved quality of produce and information gathering that will make difference between earning a profit or suffering substantial losses. WISE-5800 allows to connect to various I/O modules for thermocouple inputs that allow realtime monitoring of the temperature and humidity in the greenhouse; the DO module can be connected to various greenhouse facilities. It will real-time detect the greenhouse status and in response to sensors connected; the control system will automatically adjust vent position, fans, heating, fogging, shading, lighting, irrigation frequency, irrigation nutrient levels and CO2 levels, etc. WISE-5800 will tirelessly monitor the key environmental factors that affect crop quality and will make constant changes that a grower could not possibly achieve the same consistency level. In addition, WISE controller also support Modbus TCP protocol so that information can be instantly transmitted to the control center and makes real time monitoring of the overall status for each greenhouse more efficiently.

Facility Management System As the advance in science and technology development, the power system and the network system have become essential parts of modern life. No matter in the buildings, factories, or even outdoors, there are always control rooms with devices installed for power and network management and control. Due to the control rooms are always filled with all kinds of expensive devices and usually under high loading operations; the monitoring of temperature and humidity, and power consumption management become important issues for the whole system. WISE-5801 can be used for monitoring the unmanned facility room. WISE-5801 allows to connect to ICP DAS I-7000 and Modbus RTU slave modules; therefore it is able to connect with thermometer, hygrometer, air conditioner, warning devices and power meters. Logic rules for daily regular maintenance in the control room can be set on WISE-5801, such as: When the room temperature is getting too high and being detected, the air conditioning equipments will be turned on and a real-time alarm message will be sent to related personnel. Set up the rotation schedule for air conditioning devices to take turns operating to ensure the air conditioning devices won t be damaged due to prolonged operation. If an air conditioning device is detected to be damaged, the back-up air conditioning will be turned on for redundant operation and a real-time alarm message will be sent to related personnel. In addition, it allows to connect to WISE-5801 by SCADA software to perform the control, monitoring and collection of the I/O channel data of the facilities. And the power consumption of facilities in the control room can be statistically calculated in order to manage the electricity usage and cost as well. Disaster Prevention System In factories, most facilities and devices involved are all subject to overheating damage. From improper site wiring, lightning strikes, to overrun motors, a wide variety of overheating issues threaten systems and peripherals constantly. To ensure the safety of personals/devices, eliminate unnecessary machine downtime and achieve maximum productivity, it is necessary to build an automated system that enables real-time monitoring and disaster prevention. WISE controller provides a total solution for disaster prevention/monitoring system that will detect temperature for various devices in the factory in real time. It also enables communication between devices that will initiate immediately actions in response to emergencies. For example, in response to pre-set critical temperature threshold, the system Disaster Prevention System TC-K Type Temp. Input Devices Auto Shutdown when overheated, Restart when normal will take actions such as auto-stop the devices, turn on the temperature reduction devices, and send alarm or email to the related personnel. WISE controller also support Modbus TCP protocol so that information can be instantly transmitted to the control center and makes response to emergencies and real time monitoring of the overall factory operation more efficiently. Email Internet Modbus TCP Control Room

Environment Monitoring System As the advance of civilization causing heavy Environment Management System industrial and commercial activities, there are growing concerns about environmental issues; among them, wastewater treatment is one of the most emphasized areas for it involves IP Camera complicated process and considerable Pump number of devices needed during operations. In order to achieve reliable, high-performance, SMS efficient and cost-effective result, automation approaches are essential to wastewater Limit Switch WISE-5801 Rain Gauge treatment solutions. ICP DAS WISE-5801 controllers features real-time monitoring and reliable SMS function that is perfect for use in wastewater treatment applications. It takes only a few clicks to configure logic control that enables automation and optimization of wastewater treatment operations, such as: auto-detect the level of the sedimentation tank and response immediately based on the wastewater level. For example, when the wastewater level drops, the floodgate will be opened to load wastewater to desired level; and if the wastewater accumulates in the tank reaches a certain level, it will start the pumps to process treatment until the level decreases. In addition, WISE-5801 also allows sending SMS alarm message regarding current water level to the related personnel for immediately response. Production Line Management Eliminating unnecessary machine downtime, Product Line Management System ensuring maximum productivity and maintaining appropriate stock are keys to successful product line management. WISE Control Room controller features flexible logic functions and WISE-7126 WISE-7142 is an easy-to-learn and easy-to-use tool for creating cutting edge applications that makes it easy to take full control of your product line management.icp DAS offers full-range I/ O modules that works with WISE controller that enables to connect with product line WISE-7126 devices in various applications. The logic engine on controllers make it possible to set up different automation process by just a few clicks, for example: by connecting conveyer WISE-7142 to WISE controllers, it allows to hold the conveying of semi-finished product during the manufacturing process for further processing; measure productivities statistics, or notify the operators ready for next steps. In addition, WISE controller can also be set to detect and response immediately when an error occurs during the manufacturing process to avoid the waste of raw materials or equipment damage. WISE controller also support Modbus TCP protocol so that information can be instantly transmitted to the control center and makes real time monitoring the overall production line status more efficiently. Modbus TCP

Specification ICP DAS provides various WISE controllers for users to choose from to meet their demands for use in various industrial applications: Hardware WISE-71xx Intelligent I/O Controller Model Name WISE-7105 WISE-7115 WISE-7117 WISE-7118Z WISE-7119 WISE-7126 Pictures OS Built-in Software CPU Ethernet Port MiniOS7 WISE Firmware 16-bit CPU 10/100 Base-TX with PoE (Power over Ethernet) DI - - - - - 2 I/O Channel DO 4-4 6 4 2 AI 8 7 8 10 8 6 AO - - - - - 2 Over Voltage Protection 110 VDC/VAC - 240 Vrms 240 Vrms 240 Vrms 240 Vrms Note Support Thermistor Support RTD - Support Thermocouple Input - Model Name WISE-7142 WISE-7144 WISE-7151 WISE-7152 WISE-7160 WISE-7167 Pictures OS Built-in Software CPU Ethernet Port MiniOS7 WISE Firmware 16-bit CPU 10/100 Base-TX with PoE (Power over Ethernet) I/O Channel DI - 8 16 8 6 - DO 16 (Sink Type) 8 (Sink Type) - 8 (Source Type) 6 (Power Relay) 8 (Power Relay) Note - DI for Sink & Source Type -

WISE-790x Intelligent I/O Controller WISE-4000 Intelligent SMS I/O Controller Model Name WISE-7901(D) WISE-7902(D) WISE-4000(D) Pictures OS Built-in Software CPU MiniOS7 WISE Firmware 16-bit CPU Ethernet Port 10/100 Base-TX with PoE (Power over Ethernet) 10/100 Base-TX SMS - GPRS/GSM Quad-band 850/900/1800/1900 MHz I/O Function Support ICP DAS I/O expansion board (X-Board): X107,X109, X110, X111, X202, X203, X303, X304, X305, X308, X310, X324 Support ICP DAS FRnet remote I/O modules: FR-2053T, FR-2054T, FR-2057T 3 Digital inputs, 3 Digital outputs & 8 Analog inputs Note WISE-790xD is WISE-790x with LED Display WISE-4000D is WISE-4000 with LCD Display WISE-580x Intelligent Data Logger (with SMS) I/O Controller Model Name WISE-5800 WISE-5801 Pictures OS Built-in Software CPU Ethernet Port MiniOS7 WISE Firmware 16-bit CPU 10/100 Base-TX SMS - GPRS/GSM Quad-band 850/900/1800/1900 MHz Data Logger I/O Function Support period recording or event trigger recording with 2G microsd card Support I/O expansion board (XW-Board) by local bus Two options for remote I/O modules by RS-485 interface Support ICP DAS I-7000 series and DL series remote I/O modules (up to 16 ). Support Modbus RTU slave modules (up to 10 )

Software Model Name WISE-71xx WISE-790x WISE-4000 Pictures I/O Function Built-in 7901 With X-Board, 7902 With FRnet Built-in Rule Configuration Website IF-THEN-ELSE Logic Rule Internal Register Timer / Email / Recipe / CGI Command Connect with SCADA or HMI (Support Modbus TCP protocol) Schedule - SMS Operation - - SNTP Time Synchronization - (SMS Alarm message sending only) Data Logger - Active I/O - P2P Function Model Name WISE-5800 WISE-5801 Pictures I/O Function Rule Configuration Website IF-THEN-ELSE Logic Rule Internal Register Timer / Email / Recipe / CGI Command Connect with SCADA or HMI XW-board, I-7000 & DL modules, Modbus RTU devices (Support Modbus TCP& Modbus RTU protocol) Schedule SMS Operation - SNTP Time Synchronization Data Logger Active I/O (More Powerful) (SMS Alarm message sending & SMS Command receiving) P2P Function - Note :Two utilities are provided for all WISE series controller : WISE Rule Utility for logic rules import & export operation. WISE Firmware Uploader for WISE firmware upgrade operation.

The Real-Time automatic logic control & data recording controller in local site. Why WISE? No extra software tool is required; all operations can be done through the Web browser No programming is required. Dramatically reduce the labor and cost spent on system development Provide various hardware platforms and wide range of I/O modules that allows users to find best solutions IF-THEN-ELSE logic rules execution ability Fully automation functions supported I/O channel monitoring and control Timer/Schedule operation SMS/Email message sending, CGI command sending, SMS command receiving Recipe function for group action operation Seamless integration with SCADA through Modbus TCP/RTU protocol Automatically perform data logger operation and send back data files Active I/O operation for efficient data communication Contact Information website:http:// or www.icpdas.com e-mail:service@icpdas.com Headquarters in Taiwan No. 111, Guangfu N. Rd., Hukou Township, Hsinchu County, 30351, Taiwan TEL: 886-3-597-3366 FAX: 886-3-597-3733 Hsintien office in Taiwan 7 Fl.-2, No. 137, Lane 235, Baociao Rd., Xindian District, New Taipei City, 23145, Taiwan TEL: 886-2-8919-2220 FAX: 886-2-8919-2221 Europe ICP DAS-EUROPE GmbH website: http://www.icpdas-europe.com/ TEL: +49 (0) 7121-14324-0 FAX: +49 (0) 7121-14324-90 Shanghai (China) Suite B, Floor 6, Xin'an Building, 200 Zhenning Rd., Shanghai TEL: 86-21-6247-1722 FAX: 86-21-6247-1725 Beijing (China) Suite 6212B, Floor 2, Kangde Building, 17 Shangdiliu St., Haidian District, Beijing TEL: 86-10-6298-0933 FAX: 86-10-6296-2890 USA ICP DAS USA, Inc. website: http://www.icpdas-usa.com TEL: 1-310-517-9888 x101 FAX: 1-310-517-08