Subminiature Load Cell Model 8417



Similar documents
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Mounting Instructions. Torque Transducer. A en

Series 6000 Torque measured metal bellow coupling

Series 7500 Torque Sensor

The Do s and Don ts of Pressure Transducers

Reaction Torque Sensor

OPERATION MANUAL. Torque Sensor Models 8627, 8628, 8632

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

HERZ-Thermal Actuators

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Operating instructions

n Measuring range 0... ± 0,02 Nm to 0... ± 1000 Nm n Low linearity deviation of ± 0.05 % F.S. n Intelligent operating state indicator

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Adjustment functions for both span and shift have been incorporated

Torque Transducers MEASURING ELECTRONIC

THE STRAIN GAGE PRESSURE TRANSDUCER

Series 510 Submersible Level Transmitters

MCE380: Measurements and Instrumentation Lab. Chapter 9: Force, Torque and Strain Measurements

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Operation Manual For NDJ-8S Digital Rotary Viscometer

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

T0118 T2118 T3118. Instruction Manual

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

BroadBand PowerShield. User Manual

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

3-Component Measuring System

LCWM Glossary. Mettler Toledo LCWM Glossary

Advantium 2 Plus Alarm

Load Cell Amplifier Module. Instruction Manual LCA

Sense it! Connect it! Bus it! Solve it! EncoderS

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Contents. Document information

Description. Dimensions. Features. precision works better

Pressure Transducer to ADC Application

Mounting instructions. Force transducer. A en

How To Power A Schen

289 SERIES FLOW METER TRANSMITTERS

PALLET JACK TON

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Electronic Pressure Switch EDS 300

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

9. Force Measurement with a Strain gage Bridge

Electronic Pressure Switch EDS 3000

U15. Data sheet. Force Transducer. Special features. Mounting dimensions of the connection variants. B en

Weight Measurement Technology

Submersion/Insertion Toroidal Sensor

SDX Submersible Depth Transmitter User Manual

An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems

Digital inductive conductivity transmitter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Active Vibration Isolation of an Unbalanced Machine Spindle

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

SIMRAD SD10 Sailboat Drive

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Load Cell Troubleshooting

How To Read A Pipe From A Sensor

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

How to measure absolute pressure using piezoresistive sensing elements

Profile rail guides LLR

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Cable Solutions for Servo and Variable Frequency Drives (VFD)

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

About this Manual. Support for Your Product

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Load Cell Accuracy in Relation to the Conditions of Use

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

QR12 (1.22 ) Diameter Optical Encoder

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Picture 1 Lead Color Code Lead Function V-Link Function V-Link Pin Table 2 Picture 2 Node Commander software

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

TECHNICAL DATASHEET Incremental Encoder RI 58-H

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

ADM1TE 5/30A DIN rail single phase two wire energy meter

Transcription:

w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection... 2 2.4 Storage... 2 3. Principle of operation... 3 3.1 Spring element... 3 3.2 Mechanical design... 3 3.3 Function of the strain gauge... 4 3.4 Strain gauge wiring... 4 3.5 Deflection full scale... 6 3.6 External forces... 6 3.7 Overload protection... 6 4. Installation... 6 4.1 Surrounding mechanical parts and fastening... 7 4.1.1 Adaptation... 7 4.1.2 Mounting... 8 4.2 Electrical system, evaluation instrumentation... 9 5. Measuring chain adjustment... 10 5.1 Using the data of the test and calibration report... 10 5.2 Using calibration offset (shunt calibration)... 10 5.3 Using a physical magnitude... 10 5.4 Using a strain gauge simulator... 11 5.5 Using a precision voltage source... 11 6. Note... 12-1 / 12 -

w Technical Product Information 1. Introduction The load cells in the model 8417 series are primarily designed for the measurement of force in production equipment, using Newtons (N) as the unit of measurement. The local gravitational acceleration (g 9.81 m/s²) must be taken into account when determining masses. 2. Preparing for use 2.1 Unpacking Inspect the sensor carefully for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. Keep all packaging materials for inspection by the representative of the manufacturer or delivery company. Only transport the model 8417 sensors in their original packaging or in packaging of equivalent quality. 2.2 Using the instrument for the first time Only connect the sensor to instrumentation amplifiers that are fitted with a safety transformer according to EN 61558. Note: Transmitters connected to the outputs or other devices that are galvanically connected to the sensor's signal lines must also be fitted with safety transformers according to EN 61558. 2.3 Grounding and potential connection All connecting wires (including the cable screening braid) are electrically insulated from the sensor body. The insulation resistance between the connecting wires and the sensor body is measured. The test certificate states that the minimum resistance is greater than 10 MΩ (test voltage 45 V). - 2 / 12 -

2.4 Storage The sensor must be stored under the following conditions only: dry no condensation temperature between 0 C and 60 C Note: Provided the storage conditions have been observed, no special steps need to be taken after storage and prior to commissioning. 3. Principle of operation The sensor operates with the aid of a spring element. The force to be measured deforms the spring element elastically. This deformation is transformed into an electrical signal by strain gauges. They, together with the spring element, constitute the measuring element of the sensor. 3.1 Spring element The spring element is the most important mechanical part of a load cell. Its purpose is to take the force being measured and convert it into a linear extension. It relies on the elastic properties of the material in order to determine the force indirectly. The materials of which load cells are made must satisfy other conditions in addition to their elastic properties. As a result, only a small number of carefully selected materials come into question for high-quality load cells. burster is going one step further than this, using mainly materials from the aeronautical industry that satisfy additional quality requirements in the place of DIN materials. - 3 / 12 -

3.2 Mechanical design In the 8417 devices, a horizontally mounted elastic membrane is used as the spring element. Strain gauge Figure 1: horizontally mounted membrane of 8417 This elastic membrane is deflected by the applied force, resulting in a reduction in the sensor s overall height. This deformation cannot be seen by the naked eye. It is measured by strain gauges. In the 8417 devices, the strain gauges are mounted on the underside of the spring element. This ensures that they are subject to the same deformation as the spring element. 3.3 Function of the strain gauge The electrical resistance of a wire rises with increasing length and falling crosssection. When a wire is pulled, it becomes thinner and longer both of these effects result in an increase in its electrical resistance. This is the principle on which the function of strain gauges is based. In practice, however, strain gauges do not consist of a single wire, but of a metal foil laminated onto a carrier material. The metal foil is etched to create a meandering structure (see. Figure 2:). Figure 2: Foil strain gauge Special techniques are used to mount strain gauges manufactured in this way onto the surface of the spring element. - 4 / 12 -

3.4 Strain gauge wiring In order to reduce undesirable influences on the measurement, the strain gauges in the model 8417 a re connected as a Wheatstone bridge. Figure 3: illustrates this wiring in a simplified form. white -ε ε +U yellow a -U green a ε -ε brown Figure 3: Full-bridge strain gauge In addition to the four strain gauges shown here, compensation resistors to reduce the effect of temperature and balancing resistors to balance the bridge circuit are also incorporated. Depending on the sensor model, further resistors for the purpose of standardizing the rated characteristic are integrated into the cable or the connector. The output voltage of the sensor at maximum load, U a, is calculated as follows: U a= c x U b U b : excitation voltage c: characteristic value (sensitivity) of the sensor. The sensitivity parameter "c" can be found in the test report. It is approx. between 5 and 30 mv/v for sensors of the range 0... 200 N. For Sensors of the range 0... 500 N it is approx. 1.2 mv/v. - 5 / 12 -

If excitation voltages (U b ) in the range of 5 V DC are used, 0... 100 % loading of the sensor yields output voltages (U a ) between 0 and 150 mv or between 0 and 6 mv, dependent on the sensor s range. 3.5 Deflection full scale For sensors with diaphragm, the load lowers the middle of the measuring element. This deformation, known as the deflection full scale, is so small that it cannot be seen with the naked eye. For sensors of the model 8417, it is in the range of up to 60 µm a t max. load. T he deflection is directly proportional to the load. 3.6 External forces CAUTION! Sensor will be damaged! Avoid vibrations, even if the loads caused by these vibrations are less than the rated maximum. Design your measuring system in such a way as to prevent these external forces. Note: External forces, acting on the sensor, adulterate the result materially! External forces here refer to any force that acts outside the sensor's axis of symmetry - transverse forces, bending moments and twisting moments in particular. 3.7 Overload protection Diaphragms are sensitive to overload. Install an overload protection mechanism. Place the sensor on a spring using a guided base support. The spring deflection increases the measurement travel. It is then easier to implement a mechanism for restricting travel. Provide pressure limiters for any hydraulic or pneumatic cylinders acting on the sensor. Absolutely avoid any load that applies a sudden force (pulse). - 6 / 12 -

The high spring constant of the sensor results in high negative accelerations for moving objects. This generates extremely high forces. If, despite precautions, the sensor has been overloaded, you will notice this immediately by a change in the output signal for the zero point. Get the sensor checked out if you notice a change in the signal of 5 % or more (higher or lower) while no load is present. 4. Installation 4.1 Surrounding mechanical parts and fastening 4.1.1 Adaptation sensors are fitted into the surrounding structure by means of the external threading. In each case, there is an "active" and a "passive" side. The passive side is always tightly joined to the sensor, forming one unit with it. Note: Force should only be applied to the sensor through the outer threads. The internal thread of parts fitted to the machine may but does not have to contact the shoulder underneath the external thread. Even parts that are fitted onto the sensor can create unacceptable external forces as a result of their own weight. The axes that transmit forces must therefore be held by bearings or guides. These bearings or guides must be located as near as possible to the sensor. Secure these threads by clamping, locking or using adhesive against loosening. - 7 / 12 -

4.1.2 Mounting CAUTION! Damage to the measuring element! Offset in position or angle causes damages. The two internal threads that hold the sensor must be axially aligned. There must be no offset in either position or angle. Fastening the sensor You must connect the sensor to the evaluation electronics before you begin. Observe the display during assembly. This will help you to avoid overloading the measuring element. Manually screw the sensor into the internal thread provided. Maximum torque for assembly 1 Nm. If the cable outlet is to point in a particular direction: Align the sensor as desired. Fix the sensor in this position. You can fix the sensor in its position using assembly adhesive or a counterscrew. - 8 / 12 -

4.2 Electrical system, evaluation instrumentation CAUTION! If the cable sheath is damaged, fluids can penetrate and damage the sensor. For this reason: Take suitable precautions to relieve the bending stress exerted by the connecting cable on the cable bushing at the sensor housing. In particular, pulsating or alternating loads acting on this bushing will damage it and hence the cable will come loose. Make sure that you lay the cables with sufficiently large bend radii. Avoid vibration on the cables. Protect the cables from strain. Protect the sensor from vapors and liquids. The output signal of the 8417 normally lies between 0 and 6 mv. Hence for a measurement accuracy of 1 % you will need a resolution of approx. 20 µv or better. Hence the sensor, cables and measurement electronics, will pick up interference. The following points apply to the sensor's electrical connection: Locate the sensor, the cable and the measuring instrument outside the fields of high-energy equipment. This includes transformers, motors, contactors, frequency converters and so forth. Otherwise the electromagnetic fields from such equipment will act with their full effect on the measuring chain, causing incorrect measurements. Lay the measuring lines separately from high-power cables. If the measuring lines are laid parallel to such cables, interference will be coupled in inductively and capacitatively. In some cases it will be helpful to place an extra shield as additional protection over the measuring cable, or to lay it in a metal tube or pipe. - 9 / 12 -

5. Measuring chain adjustment The sensors of the model 8417 are calibrated ex works. Because of this, every sensor has an individual test and calibration report. However, you basically have to align every following electronic to the particular sensor. After this adjustment you have done a basic adjustment of the measuring chain. 5.1 Using the data of the test and calibration report Depending on the type of the following electronic, you are able to insert the data of test and calibration report directly or you have to use strain gauge simulator or a shunt resistor. With the help of this strain gauge simulator or a shunt resistor you are able to pretend the electric values to the electronic. 5.2 Using calibration offset (shunt calibration) Function During shunt adjustment, a precision resistor (the calibration shunt) is connected between the negative pin of the signal input and the negative pin of the reference supply voltage. The imbalance thus created in the bridge circuit corresponds to a specific change in length, i.e. to a particular load applied to the load cell. An offset, defined in this way, appears at the same time in the output signal, and can be used to adjust the entire measurement chain. The magnitude of the change in the output signal, and the value of the associated calibration shunt, can be found in the sensor's test certificate. 5.3 Using a physical magnitude Function The sensor is subjected to a known physical magnitude. In this way, the calibration is carried out over the entire measuring chain, consisting of the sensor and display device or amplifier. - 10 / 12 -

Adjustment Remove any load from the sensor. Adjust the zero. Load the sensor with a known reference weight. Adjust the reference scale value. If desired, we can prepare factory calibration or recalibration certificates for the sensor or for the entire measuring chain. These measurements are carried out at the factory on measurement installations. 5.4 Using a strain gauge simulator Function A strain gauge simulator is a bridge simulation circuit, built from precision resistors, which can be put into various output states. The strain gauge simulator (e.g. the burster strain gauge simulator model 9405) is connected to the instrumentation amplifier instead of the sensor. 5.5 Using a precision voltage source Note: The supply voltage of full-bridge strain gauge sensors affects the result of the measurement. It is possible that the actual supply voltage will vary slightly from the rated supply voltage. If you want to verify the proper function of the instrumentation amplifier using a voltage source, you must measure the sensor supply voltage with a precision digital voltmeter, and then calculate the calibration voltage. Function The sensor is simulated by a precision voltage source (e.g. the burster DIGISTANT model 4411 or 4423), which you connect to the instrumentation amplifier. - 11 / 12 -

6. Note Exclusion of warranty liability for operating manuals All information in the present documentation was prepared and compiled with great care and reproduced subject to effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measured value sensors made by burster praezisionsmesstechnik (hereinafter referred to as "product") are the results of targeted development and meticulous research. As of the date of delivery, burster provides a warranty for the proper condition and functioning of these products covering material and production defects for the period specified in the warranty document accompanying the product. However, burster excludes guarantee or warranty obligations as well as any liability beyond that for consequential damages caused by improper use of the product, in particular the implied warranty of success in the market as well as the suitability of the product for a particular purpose. Furthermore, burster assumes no liability for direct, indirect or incidental damages as well as consequential or other damages arising from the provision and use of the present documentation. 810-008417EN-5170-041515 - 12 / 12 -