RET B + RF Electronic dial setting thermostat with LCD display User & Installation Instructions

Similar documents
Drayton Digistat +2RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Drayton Digistat +2RF/+3RF

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Wireless 7 Day Programmable Room Thermostat

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

MAKING MODERN LIVING POSSIBLE. Electronic 7 Day Programmable Room Thermostat TP7000 Range. User Guide. Danfoss Heating

User Manual THR840DUK Digital Thermostat

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Installation & User Instructions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

RF 1. Contents: Connecting diagram. Detailed information:

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

BEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Wireless Thermostats 230v and Battery Operated Instruction Manual

evohome Wireless Radiator Zoning Kit Installation & User Guide

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

=============================== WARNING

PD 100A. Printing data system

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Remote Controller Manual

Stove Guard Kit User Manual

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Installation Guide for Hive Active Heating

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

KD-204. Telephone Remote Switch. Operating Instructions

EBDSPIR-PRM, EBDSPIR-PRM-IP

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

HERZ-Thermal Actuators

Digistat RF Troubleshooting Procedure

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

HORNET Remote Control Systems

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

T5000 T000 LCD Digital Fan Coil Thermostat

GB/DAS User Instruction

Product and Application Description

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

IN-OUT Thermometer with Cable Free Sensor and Clock

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

GSM Alarm System User Manual

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Unica for KNX system 226

STERILIZERS, LABORATORY DRYING OVENS

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

LT-82 Stationary IR Transmitter

REMOTE CONTROL MANUAL

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power Socket (2 Gang)

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

User s Manual Before using the inverter, you need to read and save the safety instructions.

Operating instructions IV / 2007

TC-9102 Series Surface Mount Temperature Controllers

CS488-R51I13A

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Quick start: Energy Switch EU

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

HYDRUS ULTRASONIC METER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Installation Guide. DEVIreg 530. Electronic Thermostat.

Instruction manual for models:

Please refer to the chapters below for detailed information about all aspects of the products usage.

HCE80/HCC80/HCE80R/HCC80R

Safety Warnings and Guidelines

Operating Instructions. Room temperature controller

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Wireless Home Security Alarm System AM 500

Wireless Indoor/ Outdoor Thermometer

MAGICAR M871A. Car alarm with two-way remote User s guide

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Wireless Powerlink II Receiver Set Active

Manual & Technical Documentation V1.1

Indoor Remote Controlled Power Points

igadgitz Bluetooth Audio Transmitter & Receiver (BTT009 / U3442) User Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

User Guide. 4 wire Earth Resistance Tester Model GRT300

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Transcription:

RET B + RF Electronic dial setting thermostat with LCD display User & Installation Instructions Certification Mark

2 GB F D ES DK NL G P LT I Installation Instructions 3-9 User Instructions 10-14 Instructions d installation 15-20 Instructions d utilisateur 21-23 Installationsanweisungen 24-29 Inbetriebnahme-Instruktion 30-32 Instrucciones de instalación 33-38 Instrucciones del usuario 39-41 Instruktions vejledning 42-47 Brugervejleding 48-50 Installatie handleiding 51-56 Instructiesevoor Gebruik 57-59 Ïäçãßåò åãêáôüóôáóçò 60-65 Ïäçãßåò ñþóçò 66-68 Instrukcja instalacji 69-74 Instrukcja Użytkownika 75-77 Montavimo instrukcijos 78-83 Informacija Vartotojui 84-86 Istruzioni per l uso 87-92 Istruzioni per l utente 93-95

Installation Instructions GB Features RET B (RF) / RET B-LS (RF) / RET B-NSB (RF) Contact rating 10-230 Vac, 3 (1) (excl. North America) Contact rating (N.America) 10-24 Vac, 50/60Hz, 3(1)A Temperature Accuracy ±1 C Contact Type SPDT Type 1B Transmitter frequency 433.92 MHz (RF models) Transmitter range 30m max (RF models) Power Supply 2 x AA/MN1500 alkaline batteries Control Pollution Situation Degree 2 Rated Impulse Voltage 2.5 kv Designed to meet BS EN 60730-2-9 (EN 300220 for RF) Ball Pressure Test 75 C Temperature Range 5-30 C Dimensions (mm) 85 wide x 86 high x 42 deep Installation Instructions Important note RF products: Ensure that there are no large metal objects, such as boiler cases or other large appliances, in line of sight between the transmitter and receiver as these will prevent communication between thermostat and receiver. 3

GB Mounting Installation Instructions 4 Fix at a height of 1.5m approx from the floor, away from draughts or heat sources such as radiators, open fires or direct sunlight.

Wiring (not RF models) GB RET-B (3050 12/01) Installation Instructions 5

GB Installation Instructions DIL switch settings Slide the DIL switches to the settings required (see below) Heating selection COOL ON/OFF 6 CYCLES F Cooling selection HEAT CHRONO 3 CYCLES C ON/OFF - boiler switches ON when below set temperature and OFF when above CHRONO - energy saving feature which fires the boiler at regular intervals to maintain a set temperature, achieving a constant ambient environment for the user. COOL NO DELAY 4 MIN DELAY F HEAT COMPRESSOR DELAY 2 MIN DELAY C use 6 Cycles for radiator systems use 3 Cycles for underfloor heating 6

Locking & Limiting Receiver Wiring (RF only) RX1 RX2 and RX3 GB Installation Instructions ELECTRONICS ELECTRONICS N L 1 2 3 4 COM ZONE 1 ON ZONE 1 OFF A B C 1 2 3 4 5 6 N L COM ZONE 1 ON Note: 1) For mains voltage operated systems, link terminal 2 to mains live supply 2) Power supply to unit must not be switched by timeswitch ZONE 1 OFF ZONE 2 ON ZONE 3 ON TERMINAL 6 RX3 ONLY 7

GB Installation Instructions Commissioning (RF only) If the thermostat and the receiver have been supplied together in a combined pack, the units have been paired in the factory and no commissioning is required (RX1 only). Step 1 RET B-RF Position the setting dial to number 1. Remove dial, press & hold LEARN button for 3 seconds (located under setting dial). Do not replace the setting dial yet NOTE: Thermostat now transmits signal continuously for 5 mins. LEARN Step 2 RX1 8 Press and hold buttons PROG and CH1 until green light flashes.

Step 3 RX2/RX3 For RX2 or RX3 repeat steps 1 and 2 for each thermostat and channel, leaving at least 5 mins between the commissioning of each thermostat. Step 4 RET B-RF To replace the thermostat setting dial, position the dial to number 1. GB Installation Instructions 9

GB User Instructions 10 What is a room thermostat?... an explanation for householders. A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.

The heating system will not work if a timeswitch or programmer has switched it off. The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature say 18 C and then turn it up by one degree each day until you are comfortable with the temperature. You won t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly. GB User Instructions 11

GB User Instructions User Instructions Display The LCD displays actual room temperature until the setting dial is moved. Setting the temperature Turn setting dial to required temperature. The selected temperature will flash in the LCD to signify it is showing set temperature. After a short period the display stops flashing and shows actual room temperature. Thermostat status (heat mode only) 12 A flame symbol will be lit whenever the thermostat is calling for heat.

Thermostat status (cool mode only) A snowflake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to flash, the thermostat output is delayed for a short period to prevent compressor damage. Low battery indication A battery symbol will flash in the display when batteries require replacement. Batteries should be replaced within 15 days, after which the thermostat will turn off the load it is controlling. When this happens Of will be displayed. IMPORTANT: alkaline batteries must be used. GB User Instructions 13

GB User Instructions RET B-LS model only This model is fitted with an Auto/Off switch. When the switch is set in I position the thermostat controls at the temperature set by the setting dial. When set to O the thermostat output is turned off and Of is displayed. RET B-NSB model only This model is fitted with a Day/Night switch. When the switch is set to the Sun Symbol, the thermostat controls at the temperature set by the setting dial. When set to the Moon symbol, the thermostat controls at 4 C below the temperature set by the setting dial. 14 NOTE: if used to control cooling, thermostat controls 4 C higher, with switch in MOON position.

www.danfoss.com/businessareas/heating 15 Part No 25693v09 07/07