SOUND ACTIVATED SWITCH INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
PagePac PAGEPAL V

PS 155 WIRELESS INTERCOM USER MANUAL

Advantium 2 Plus Alarm

Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output

Model SRMD Setra Remote Monitoring Display

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

PERF10 Rubidium Atomic Clock

MusicTel-60. Music on-hold SYSTEM. Installation Manual

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

CONTROL SWITCHER User s Manual (Preliminary)

AS-801 Promotion-On- Hold Segregator. Version 2.10

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

INSTALLATION & SERVICE MANUAL. Display Panel

PEDAL POWER. User s Manual

Single Station Remote Alarm

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

T-Extender E-Extender

F2400 FOM II Series Fiber Optic Modem Technical Manual

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

Water Leak Detection System

5 CHANNEL MIXER. S Class Signal Processors

PSC POWER STAR LiFE TM

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

LOXONE 12 Channel Amplifier

Unattended Answering Device Instruction Manual

Line Level Converter Box. S Class Signal Processors

MDC Series

AM/FM Component Stereo Receiver System ( ) Preparation Faxback Doc. # 18708

Contents. Safety Warnings... 1

User's Guide. Integrating Sound Level Datalogger. Model Introduction

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Installation & User Manual

GLOLAB Two Wire Stepper Motor Positioner

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

PERSONAL MONITOR MIXER/HEADPHONE AMP. S Class Signal Processors

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

PCM2000 Configuration Guide

Auto Dialer. Manual E-921APQ E-921GPQ

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

TIF-101 Telephone Interface Installation and Use

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

USER INSTRUCTIONS DESCRIPTION:

Zetron Desktop Microphone Manual F

Model: (Four Port) (Six Port) HDMI Selector Switches

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

40 Watt Mixer Amplifier Owners Manual with Media Player

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Digital FM/AM Receiver

Spectrum Technologies, Inc.

AUTODIALLER / QUICKDIALLER - SA132

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

SYSTEM MIX PLUS. Owner's Manual DIGITAL MUSIC CORPORATION

HM-W536 Install Guide

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

A/DA PEDAL PREAMP APP-1 USER S MANUAL

the promoh OPERATING MANUAL

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

Operation and Installation Manual

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Universal Wireless Effects Controller USER S GUIDE SA115

LDG SLS-2 Two-Port RJ45 Switch

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

CHAPTER 1. GETTING STARTED... 1

±15 V Current-Limited Power Supply

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

SingleNet Single Cable Control System

ALARM CLOCK RADIO FOR ipod/iphone

MR8 Loop System OWNER'S MANUAL

OCEAN TECHNOLOGY SYSTEMS

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

Tone Hammer 500. Owners Manual. Manual Version 1.0

USER GUIDE. Publication AP8509. Allen & Heath 1 XONE:K2 User Guide

Global Water Instrumentation, Inc.

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Load Cell Amplifier Module. Instruction Manual LCA

ER102. Emergency Crank Weather Radio Owner s Manual.

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

D287/D288/D292/D293A/D293E

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

Transcription:

6955 VALJEAN AVE, VAN NUYS, CA 91406 PH: (818)994-6498 / FAX: (818)994-6458 techsupport@louroe.com / www.louroe.com SOUND ACTIVATED SWITCH INSTALLATION AND OPERATING INSTRUCTIONS AD-1 POWER SUPPLY DESCRIPTION (2) RCA SINGLE CABLES The is a sound activated switch, based on sound pressure level, that can be used with the Louroe ASK-4 #101, any Louroe base station or as a stand alone with any Louroe Microphone. The provides an adjustable threshold that activates when the microphone is subjected to a noise or sound that exceeds the set threshold level. The unit has two sets of NO/NC relay contacts for activating a camera, light, machinery, etc. A Louroe base station is used if sound (audio) is to be monitored or recorded. The can accommodate a 10K balanced or 10K unbalanced input. All Louroe microphones produce an unbalanced 600 line level output. The length of release latching time can be set from 0.5 to 60 seconds. A built-in LED illuminates when the threshold setting has been exceeded and the unit is triggered. Contents Description Sound Activated Switch. Activates the audio and relay when a sound above the set threshold is detected. Usually connected between a base station and microphone. AD-1 listed AC ADAPTER. Supplies 12 Vdc to DA-1 U 2 Single RCA Cables For connecting RCA outputs to a base station and other audio receiving devices. Page 1 of 8

INSTALLATION AND OPERATING INSTRUCTIONS 1 2 3 SENSITIVITY SETTING A B1 B2 C MIC IN JP4 SOUND ACTIVATED SWITCH LATCH RELEASE TIME RELAY 2 RELAY 1 NO COM NC NO COM NC 11 10 9 8 4 12 Vdc L E OUROE LECTRONICS LINE OUT 7 5 TRIGGERED MIC OUT 6 Fig. 1 Panel Description [1] Sensitivity Setting Potentiometer Sets the level of sound for activating the switch. Rotating the potentiometer clockwise increases the sensitivity of the VOX switch. The more sensitive the setting, the less sound level is needed to trigger the unit. [2] MIC-IN Terminal Block Connects to remote microphone or other audio devices. May be connected to balanced or unbalanced audio source. Mic input is factory set for unbalanced connections. When using balanced audio source, remove jumper marked JP4. Louroe microphones are unbalanced and utilize terminals A, B1 and C. [3] Jumper JP4 jumper is removed when using a balanced audio source. (microphone with a 600 balanced output) [4] Power Jack + 12Vdc AC Adapter (supplied). [5] MIC IN/OUT Jack Unswitched audio output from remote microphone or other audio device (seldom used) can be monitored using audio jack. May also be used to accept audio from external sources without using the Mic Input Terminal Block[2]. [6] Triggered MIC Out Jack Switched audio output from remote microphone or other audio device can be monitored using RCA jack. No audio is produced until the unit is triggered. [7] Line OUT Jack Unswitched audio output level from RCA jack can be adjusted by rotating the Sensitivity Setting Potentiometer[1]. Rotating clockwise increases the threshold sensitivity as well as the audio output. Rotating counterclockwise decreases audio output. [8] Relay Output 1 3-Pin terminal block marked NO(normally open), COM (common), NC (normally closed). Provides relay closure when the unit is triggered. Maximum contact rating is 5A @ 30 Vdc or 5A @ 277 Vac. [9] Relay Output 2 3-Pin terminal block marked NO(normally open), COM (common), NC (normally closed). Provides a second relay closure when unit is triggered. [10] Latch Release Potentiometer Sets relay latching time. Rotate the potentiometer shaft slowly clockwise for more time release or counterclockwise for less. Time can be set from 0.5 to 60 seconds. [11] Alarm LED Illuminates when unit is triggered or is in alarm. Turns OFF when the latching time for the relay expires. Page 2 of 8

INSTALLATION AND OPERATING INSTRUCTIONS CONNECTIONS AND TEST (See sample interconnection diagram on page 4) The following connections and test procedures below use Louroe s Microphone and Base Station. If using microphone or audio receiving device from another manufacturer, refer to its installation and operating instructions. West Penn 452 is used as sample cable for this procedure. Red wire is 12Vdc Black wire is Audio Output Bare wire is Ground CONNECTING LOUROE MICROPHONE TO 1) CONNECT ONE END OF 2 CONDUCTOR SHIELDED CABLE TO 3-PIN BARRIER BLOCK OF REMOTE MICROPHONE AS FOLLOWS: a) Connect RED wire to terminal marked A of microphone. b) Connect BLACK wire to terminal marked B of microphone. c) Connect BARE wire (drain) to terminal marked C of microphone. 2) CONNECT THE OTHER END OF 2 CONDUCTOR CABLE TO THE MIC INPUT TERMINAL BLOCK [2] OF AS FOLLOWS: IF USING A LOUROE MICROPHONE (3 WIRE CONFIGURATION) a) Connect RED wire to terminal marked A of. b) Connect BLACK wire to terminal marked B1 of. c) Connect BARE (drain) wire to terminal marked C of. IF USING A MICROPHONE FROM OTHER MANUFACTURERS WITH 600 BALANCED OUTPUT (2-WIRE CONFIGURATION) a) Connect one wire to terminal B1 b) Connect one wire to terminal B2 c) Remove JP4 jumper from socket [3] CONNECTING TO A LOUROE BASE STATION (If applicable) 1) Using an RCA connector cable, cut the RCA plug off of one end. Connect the end with the RCA plug to the RCA jack marked Triggered MIC OUT[6] on the. 2) Connect the other end (stripped wire) of RCA cable to terminal block of base station marked A, B, C as follows 1 The larger wire of stripped end (with jacket) connects to terminal B of base station. 2 The copper wire (bare) goes to terminal C of base station. Terminal A of base station is not used with this application. TEST AND OPERATION 1) Plug 12Vdc power supply to Power Jack[4]. 2) Plug AC Adapter to a standard 115Vac wall outlet or power strip. 3) Rotate the Latch Release Potentiometer [10] clockwise to desired length of time. Latch time is from 0.5 to 60 seconds. 4) Turn ON power to the Louroe Base Station. A 12Vdc AC Adapter is included with base station. 5) Rotate the Volume Control Knob of the Base Station clockwise to increase the volume of audio. 6) Generate some noise at the area where the remote microphone is located. Rotate the Sensitivity Setting Potentiometer[1] clockwise to increase the level of audio sensitivity until the goes into alarm, as indicated by the illuminated Alarm LED[11]. The two relay outputs should all be closed. (COM - Common; NO - Normally Open; NC - Normally Closed) 7) If Triggered MIC Output Jack[6] is connected to the Base Station, audio from the microphone at the remote location will be present at the speaker as soon as the goes into alarm. Audio remains on until the time set for the latch release expires. 8) If the sound that initiated the alarm continues, the will re-activate for the time set and again shut off. This procedure will continue until the sound falls below the threshold level or ceases. Page 3 of 8

DE A INSTALLATION AND OPERATING INSTRUCTIONS INTERCONNECTION DIAGRAM FOR VERIFACT A MICROPHONE SOUND ACTIVATED SWITCH APR-1 AUDIO BASE STATION MODEL VERIFACT A N Microphone gain adjust: N is normal, L is low A B C L All Louroe Verifact Microphones are compatible with and are 600 unbalanced TERMINAL BLOCK IDENTIFIER FOR MICROPHONE (A) - 12Vdc Red wire (B) - Audio Output Black wire (C) - Ground Bare wire RED (A) BLACK (B1) BARE (C) WEST PENN 452 OR EQUIVALENT 2 COND. SHIELDED 22 GAUGE Verifact A Microphone shown as an example MAXIMUM DISTANCE BETWEEN MICROPHONE AND IS 1,000 FT (305m) 12 VDC Power supply Model TRIGGERED MIC OUT RCA PLUG TRIGGERED MIC OUT 12 Vdc L E OUROE LECTRONICS LINE OUT BARE (C) RELAY 1 NO COM NC B1 B2 C MIC IN SOUND ACTIVATED SWITCH RELAY 2 NO COM NC LATCH RELEASE TIME BLACK (B1) SENSITIVITY SETTING RED (A) TERMINAL BLOCK IDENTIFIER FOR (A) - 12Vdc (B1) - Unbalanced Audio (Louroe Microphone) (B2) - Balanced Audio (microphone from other manufacturers) (C) - Ground WIRING REQUIREMENTS 2 Conductor shielded cable, 22 gauge with a 24 gauge drain wire NOTE: Unshielded cable is not satisfactory for audio systems West Penn 452 or equivalent Stripped end of RCA cable SA U IN A M MIC INPUT A B C AUDIO +12 Vdc INPUT OUTPUT VAN NUYS, CA 12Vdc Power supply (included) Rear panel of APR-1 Audio Base Station Page 4 of 8

INSTALLATION AND OPERATING INSTRUCTIONS SPECIFICATIONS Current drain Audio input impedance Relay contact DC input Relay latch time Dimensions Weight Shipping Weight 70 ma 10K 5A @ 277 Vac or 5A @ 30Vdc 12Vdc, 500mA 0.5 to 60 seconds 6 1/8 L x 4 5/8 W x 1 7/8 H 7 oz 1lb Page 5 of 8

INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT NOTICE When this equipment is used as part of an audio monitoring system, the law requires that the public be given notice of AUDIO MONITORING ON THE PREMISES. A decal notice is included with each microphone shipped. AUDIO MONITORING On These Premises Federal Law References: Federal Regulations, US Code, Title 18. Crime and Criminal Procedure, Sec 2510. WARRANTY LOUROE ELECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship. Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment. This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS. This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation instructions provided by LOUROE ELECTRONICS. Returned shipments to LOUROE ELECTRONICS shall be at customer s expense. LOUROE ELECTRONICS will return the equipment prepaid via best way. Page 6 of 8

NOTES Page 7 of 8

INSTALLATION AND OPERATING INSTRUCTIONS MANUFACTURED IN THE Page 8 of 8