USB pressure transmitter With USB adapter and software Model CPT2500

Similar documents
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Precision digital pressure gauge Model CPG1500

Hand-held thermometer Model CTH7000

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Compact pressure switch Flameproof enclosure Ex d Model PCA

Datalogger DL/N 70 Version:

Electronic Pressure Monitoring New Products

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Test equipment for temperature and its reduction

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Features. Picture. Specifications

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Bimetal thermometer Model 52, industrial series

Impedance 50 (75 connectors via adapters)

Conductive Level Switch FK 2 Technical Data:

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Differential Pressure Transmitter Model DPT-10

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

T0118 T2118 T3118. Instruction Manual

Relative and absolute pressure switch type 529

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Digital inductive conductivity transmitter

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Electronic Pressure Switch EDS 300

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Electronic Pressure Switch EDS 3000

How To Use A Flowmeter

Vacuum drying oven for non-flammable solvents

1 Technical Description Lokal-200PC

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Bypass level indicator With magnetic display Model BNA

The PACE5000 Modular Pressure Controller/Indicator

Instruction Manual. T3111 T3111L T3111P T3111Ex

Rosemount 333 HART Tri-Loop

KNC Model 3666 Automatic Pressure Calibration System

Measurement Solutions for Refrigeration Technology.

USB-500/600 Series Low-Cost Data Loggers and Accessories

Precision Pressure Indicator Model CPG2500

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Control- and feedback head for integrated mounting on Robolux valves Type 2036

AXIS 262+ Network Video Recorder

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

JOFRACAL Temperature and Pressure Calibration Software

2.24. Pump Controller 704. Data Sheet

Rosemount 333 HART Tri-Loop

Plastic tube flowmeters Series PT/PS

Data-logger evaluation software GSoft V2.8

ViewLinker USB 2.0 Graphics Adapter

USB-500/600 Series Low-Cost Data Loggers and Accessories

Data Sheet PS1B Pressure Switch

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

3/2-way Solenoid Valve, direct-acting, NC or NO

Incubator with mechanical convection

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Electronic Product Catalog

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Multi-Range Programmable DC Power Supplies 9115 Series

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

is then retained absolutely without interruption.

VENTIsupport Version 1

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Combi switchbox with integrated 3/2 way pilot valve

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Fast closing valve Series 75

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Temperature Datalogger Users Manual

Pressure switches for gas and air Pressure sensors

Micro Motion 3098 Gas Specific Gravity Meter

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Software and Display instruments

SITRANS F flowmeters SITRANS F M

Version 30 Installation

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

USB/RS485 converter cable, complete

PHOENIX CONTACT - 03/2007

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

MINIMAT-EC-Servo Screwdriver Spindles

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

PACE Modular Pressure Controller

Digital Pressure Measuring Instrument MDR480

Hydraulic Control Solutions

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

NI USB-5681 RF Power Meter Specifications

TEIP11 I/P signal converter for standard signals. Measurement made easy

TORKEL 820 Battery Load Unit

Transcription:

Calibration technology USB pressure transmitter With USB adapter and software Model CPT2500 WIKA data sheet CT 05.01 Applications Calibration service companies and service industry Quality assurance Recording and monitoring of pressure processes Measurement of pressure peaks Special features Recording interval can be set from 1 ms... 10 s Measuring ranges from 0... 25 mbar to 0... 1,000 bar Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate) No external voltage supply required Software for recording of measured values, calibration and evaluation Model CPT2500 USB pressure transmitter with model CPA2500 USB adapter Description Extensive application possibilities The CPT2500 USB pressure transmitter is suitable for connection to any PC with a USB port, via the CPA2500 USB adapter. For the USB adapter there are stainless steel pressure transmitters available with measuring ranges up to 1,000 bar. The USB adapter automatically detects the measuring range of the currently connected pressure transmitter and ensures a highly accurate pressure measurement. Functionality The measurement interval for pressure recording can be set in the range of 1 ms... 10 s. With a recording interval of more than 5 ms the following data is recorded in addition to the current measured value: the mean value over the recording interval the maximum and minimum value during the recording interval Thus pressure peaks within the overall recording interval can be very easily identified. It is also possible to set start and stop conditions for the recording. In this way it is possible to detect pressure peaks with a resolution of up to 1 ms. The CPT2500 is a thus very well suited to all applications where, over a limited time span, pressure processes must be recorded and analysed with high resolution. Software The USBsoft2500 and USB ScanSoft software are delivered as standard with the USB adapter. With it, all settings for recording the pressure process can be made. The recorded measured values can be graphically displayed and evaluated. In addition to the USBsoft2500 and USB ScanSoft software, WIKA-CAL calibration software for calibration tasks is also available. Using this software, the data is automatically transferred into a printable calibration certificate. Furthermore, WIKA-CAL also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. For data transfer, a USB interface is available. WIKA data sheet CT 05.01 05/2014 Page 1 of 6 Data sheets showing similar products and accessories: Hand-Held pressure indicator; model CPH6200; see data sheet CT 11.01 Hand-Held pressure indicator; model CPH6300; see data sheet CT 12.01 Test pumps, hydraulic; CPP-Series; see data sheet CT 91.05 Hand test pump, pneumatic; model CPP30; see data sheet CT 91.06 Calibration software; WIKA-CAL; see data sheet CT 95.10

Complete service case For easy transport and safe storage, the USB adapter is delivered in a compact transport case, which can also hold one or more pressure transmitters. Certified accuracy For each reference pressure sensor, the accuracy for the complete measuring chain is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a DKD/DAkkS calibration certificate for this instrument. Specifications USB pressure transmitter model CPT2500 (complete measuring chain) Measuring range mbar 0... 25 0... 40 0... 60 0... 100 0... 160 0... 250 0... 400 0... 600 Overpressure limit mbar 500 500 500 1,000 1,500 2,000 2,000 4,000 Burst pressure mbar 1,000 1,000 1,000 2,000 2,000 2,400 2,400 4,800 Resolution dependant on pressure range (max. 4 1/2-digit) Measuring range bar 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 0... 16 0... 25 Overpressure limit bar 5 10 10 17 35 35 80 50 Burst pressure bar 6 12 12 20.5 42 42 96 96 Resolution dependant on pressure range (max. 4 1/2-digit) Measuring range bar 0... 40 0... 60 0... 100 0... 160 0... 250 0... 400 0... 600 0... 1,000 Overpressure limit bar 80 120 200 320 500 800 1,200 1,500 Burst pressure bar 400 550 800 1,000 1,200 1,700 2,400 3,000 Resolution Type of pressure Accuracy of the measuring chain dependant on pressure range (max. 4 1/2-digit) Relative pressure, {absolute pressure from 0... 25 bar abs. and vacuum from -1... +24 bar} 0.2 % FS (resolution 4-digit); {optional: 0.1 % FS (resolution 4 1/2-digit)} { } Items in curved brackets are optional extras for an additional price. Rererence pressure sensor model CPT2500 Process connection 1) G ½ B; {flush diaphragm (G 1 for 0.1 up to 1.6 bar) or various connection adapters on request} Pressure units mbar, bar, Pa, kpa, MPa, mmhg, psi, inhg (0 C), inhg (60 F), mws; (depending on the measuring range, selectable) Material Wetted parts Stainless steel or Elgiloy, (> 25 bar with additional NBR seal) 2) Flush diaphragm version: stainless steel {Hastelloy C4}; O-ring: NBR {FKM/FPM or EPDM} Internal transmission fluid Synthetic oil (only for measuring ranges up to 16 bar or flush diaphragm) {Halocarbon oil for oxygen applications}; {Listed by FDA for food industry} Sensor specification Accuracy per year 0.2 % of span at reference conditions 3) Compensated range 0... 80 C Mean temperature coefficient Measuring rate 0.2 % of span/10 K (outside of reference conditions) 1,000 measurements/s Permissible ambient conditions Medium temperature -25... +100 C 4) Operating temperature -20... +80 C Storage temperature -40... +100 C 4) Relative humidity 0... 95 % r. h. (non-condensing) Case Material Dimensions Weight Stainless steel see technical drawings approx. 220 g { } Items in curved brackets are optional extras for an additional price. 1) As an oxygen version, a flush diaphragm model is not available. In an oxygen version, the model CPT2500 is only available in gauge pressure ranges 0.25 bar, with media temperatures between -10 +50 C and using stainless steel or Elgiloy wetted parts. 2) For pressure measuring ranges 0... 25 mbar, 0... 40 mbar and 0... 60 mbar all wetted parts are made of stainless steel, silicium, aluminium, gold, silicone. 3) Reference conditions: 15... 25 C 4) For pressure measuring ranges 0... 25 mbar, 0... 40 mbar and 0... 60 mbar the medium temperature and storage temperature are limited to +80 C. Page 2 of 6 WIKA data sheet CT 05.01 05/2014

USB adapter model CPA2500 Communication PC connection Standard USB connector (type A) Electrical sensor connection Circular connector, 7-pin, M16 x 0.75 Recording interval Recording options 1 ms... 10 s, adjustable via software selectable start/stop conditions, pre-trigger, stop-delay Voltage supply Power supply Supply via USB port Permissible ambient conditions Operating temperature -25... +50 C Storage temperature -25... +70 C Relative humidity 0... 95 % r. h. (non-condensing) Case Dimensions Weight see technical drawings approx. 120 g CE conformity, approvals, certificates CE conformity for the model CPT2500 USB pressure transmitter Pressure equipment directive 97/23/EC, module A, pressure accessory EMC directive 2004/108/EC, EN 61326 Emission (group 1, class B) and interference immunity (commercial applications, laboratories, service centres and workshops) CE conformity for the model CPA2500 USB adapter EMC directive 2004/108/EC, EN 61326 Emission (group 1, class B) and interference immunity (controlled electromagnetic environment) Approvals GOST-R Import certificate, Russia Certificates Calibration Standard: 3.1 calibration certificate per DIN EN 10204 Option: DKD/DAkkS calibration certificate Approvals and certificates, see website Dimensions in mm USB adapter model CPA2500 Lumberg KV 70 USB connector type A WIKA data sheet CT 05.01 05/2014 Page 3 of 6

Dimensions in mm USB pressure transmitter model CPT2500 USBsoft2500 and USB ScanSoft configuration and evaluation software The USBsoft2500 software is required for the operation of the model CPT2500 USB pressure transmitter in connection with the model CPA2500 USB adapter. This enables the configuration of the pressure transmitter as well as the selection of the various recording settings. The software also allows different start/stop conditions to be defined, in order to easily identify, for example, a single pressure peak. Graphical evaluation of the measured data (including mean, min- and max-values), in addition the measured data can also be exported to other software. Several series of measurements can be displayed in a single chart. Using software USB ScanSoft, several CPT2500 in combination with model CPA2500 USB adapter can be run parallel. For each CPT2500 one CPA2500 is required. Performance data Recording interval of 1 ms... 10 s Data export to other programs e.g. Excel Languages: German, English, Spanish and Czech System requirements for USBsoft2500 CPU with at least 1 GHz At least 20 MB free hard disc space CD-ROM drive At least 256 MB RAM Windows operating system 95, 98, NT 4.0 (with Service Pack 3.0 or higher), 2000, XP, Vista or 7 USB port System requirements for USB ScanSoft CPU with at least 1.2 GHz At least 100 MB free hard disc space CD-ROM drive At least 1 GB RAM Windows operating system XP (SP 3), Vista (SP2) or 7 (SP1) USB port Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Page 4 of 6 WIKA data sheet CT 05.01 05/2014

WIKA-CAL calibration software Easy and fast creation of a high-quality calibration certificate The WIKA-CAL calibration software is used for generating calibration certificates or logger protocols for pressure measuring instruments and is available as a demo version for a cost-free download. A template helps the user and guides him through the creation process of a document. In order to switch from the demo version to a full version of the respective template, a USB key with the template has to be purchased. The pre-installed demo version automatically changes to the selected full version when the USB key is inserted and is available as long as the USB key is connected to the computer. Creation of calibration certificates for mechanical and electronic pressure measuring instruments A calibration assistant guides you through the calibration Automatic generation of the calibration steps Generation of 3.1 certificates in accordance with DIN EN 10204 Creation of logger protocols User-friendly interface Languages: German, English, Italian and more due with software updates For further information see data sheet CT 95.10 Calibration certificates can be created with the Cal-Template and logger protocols can be created with the Log-Template. Cal Demo Generation of calibration certificates limited to 2 measuring points, with automatic initiation of pressures via a pressure controller. Cal Light Generation of calibration certificates with no limitations on measuring points, without automatic initiation of pressures via a pressure controller. Log Demo Creation of data logger test reports, limited to 5 measured values. Log Creation of data logger test reports without limiting the measured values. WIKA data sheet CT 05.01 05/2014 Page 5 of 6

Scope of delivery USB pressure transmitter model CPT2500 USB adapter model CPA2500 Software USBsoft2500 and USB ScanSoft Transport case Operating instructions 3.1 calibration certificate per DIN EN 10204 Options DKD/DAkkS certified accuracy Sensors for oxygen applications Accessories Connection adapters Various pressure adapters MINIMESS quick-connect process connection system Transport case with USB pressure transmitter and USB adapter Pressure generation Pneumatic test pumps Hydraulic test pumps Software WIKA-CAL calibration software Ordering information Model / Unit / Measuring range / Accuracy / Process connection / Extension cable / Type of certificate / Accessories / Additional order information 2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 6 of 6 WIKA data sheet CT 05.01 05/2014 05/2014 GB WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de