WHITE PAPER December, 2001



Similar documents
By: Mohsen Aminifar Fall 2014

Analysis of xdsl Technologies

Broadband 101: Installation and Testing

DSL Variations. NEXTEP Broadband White Paper. Broadband Networks Group. Definitions and differences of Digital Subscriber Line variations.

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Intel System Engineers Documents. DSL General Overview

Residential Broadband: Technologies for High-Speed Access To Homes

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE TSAC WORKING GROUP ON NEW STANDARDS AND POLICY (NSP)

Implementing Fast Ethernet

Digital Subscriber Line (DSL) Requirements

Residential Broadband: Technologies for High-Speed Access To Homes

How To Get High Speed Internet In Australia

ADSL or Asymmetric Digital Subscriber Line. Backbone. Bandwidth. Bit. Bits Per Second or bps

Connection Services. Hakim S. ADICHE, MSc

Network Neutrality Statement

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Wireless Links - Wireless communication relies on radio signals or infrared signals for transmitting data.

Network Design. Yiannos Mylonas

INTRODUCTION TO DSL CHAPTER THE TELEPHONE LOOP PLANT. 1.1 The Telephone Loop Plant. 1.2 DSL Reference Model. 1.3 The Family of DSL Technologies

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

1 Which network type is a specifically designed configuration of computers and other devices located within a confined area? A Peer-to-peer network

Network Topologies. Network Topologies

Enhanced Category 5 Cabling System Engineering for Performance

Gigabit Ethernet: Architectural Design and Issues

CWNA: Official Certification Guide Unit 1 Introduction to Wireless LANs

ADSL BROADBAND BASICS FOR THE DOMESTIC USER. The Main Limitations of ADSL Broadband are as follows.

Nexus Technology Review -- Exhibit A

How DSL Works. by Curt Franklin

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

The Evolution of the U.S. Telecommunications Infrastructure Over the Next Decade

XDSL and DSLAM Access Technologies

DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting

Gigabit Ethernet on Copper Cabling Infrastructures

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

(Refer Slide Time: 2:10)

INTERNET CONNECTIVITY

Black Box Explains: DSL

Exam questions. 1. Which of the following are true regarding xdsl? Choose three. It uses a portion of the existing phone line.

VDSL (VERY HIGH DATA BIT RATE DIGITAL SUBSCRIBER LINE)

Chapter 5. Data Communication And Internet Technology

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

A General Glossary of Telecommunications Terminology

Chapter 4 Connecting to the Internet through an ISP

Next Generation of High Speed. Modems8

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Technical Paper. Digital Subscriber Line (DSL): Using Next Generation Technologies to Expand Traditional Infrastructures

How to Choose the Right Cable Category

ECE Chapter 1

1.264 Lecture 34. Telecom: Connecting wired LAN, WAN. Next class: Green chapter 17. Exercise due before class

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

EFM Copper (EFMC) Tutorial. June 2004

Data Link Layer. Page 1. Ethernet

Ethernet. Ethernet Frame Structure. Ethernet Frame Structure (more) Ethernet: uses CSMA/CD

HDSL Basics. HDSL Basics. Introduction. HDSL Overview

Chapter 1. Introduction. 1.1 Research Motivation and Objective

Ethernet Passive Optical Networks EPON

Telecommunications, Networks, and Wireless Computing

Introduction to Digital Subscriber s Line (DSL)

Introduction to Digital Subscriber Line Technology

Characterization of a new copper cable for next generation DSL systems

Frame Burst Adjusting for Transmitting Video Conference in Gigabit Ethernet

ADSL over ISDN, DAML, and Long Loops

Appendix A: Basic network architecture

Fundamentals of Telecommunications

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

DSL: An Overview. By M. V. Ramana Murthy. All Rights Reserved

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Digital Subscriber Line (DSL)

11/22/

TR-013 Interfaces and System Configuration for ADSL Central Office Issue: 1.0 Issue Date: January 1999

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Digital Subscriber Line

How To Get A Phone In The United States

Acterna DSL Services Tester TPI 350+ Application Highlights

E1-E2 (EB) Chapter 8A. Broadband Services

SYSTIMAX Copper Solutions Designed for the Digital Generation

SHDSL in Ericsson ENGINE Access Ramp

Voice Grade Copper. Characteristics, problems and spectral management. EFM July, 2001 Hugh Barrass (Cisco Systems) With Thanks to:

Fast Ethernet and Gigabit Ethernet. Computer Networks: Fast and Gigabit Ethernet

EXAMPLES AND PROBLEMS. Competence Based Education Internet Protocols

Analysis Techniques for Loop Qualification and Spectrum Management

DSL and Cable Modem Networks

Security & Surveillance Cabling Systems

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Data Communications Competence Center

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Introduction to Ethernet

10BaseS: Ethernet transport over standard twisted pair wire

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

COMPLETE YOUR GO-TO-MARKET PLAN BUSINESS SOLUTIONS BARRY DERRICK PRODUCT MARKETING MANAGER

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

Computers Are Your Future Prentice-Hall, Inc.

V101. VDSL LAN Extender

Objectives. Remote Connection Options. Teleworking. Connecting Teleworkers to the Corporate WAN. Providing Teleworker Services

EECC694 - Shaaban. Transmission Channel

Transcription:

Is Superior Essex Outside Plant Copper Cable Rated Category 3? The applicability of the Category 3 specification to outside plant cables is sometimes misunderstood. This white paper examines that issue, as well as the differences between typical OSP and Premises data protocols and their applicability to OSP cables. Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 1 of 6

Superior Essex Copper OSP (Outside Plant) cables are designed and guaranteed to meet all applicable industry standards for OSP installations (i.e., Rural Utility Service or RUS, Bellcore, American National Standards Institute or ANSI, Insulated Cable Engineers Association or ICEA). These OSP standards are designed to handle the applications used predominantly in OSP environments for distances up to and exceeding 20,000 feet; including T1, DSL, and ISDN. The standards used for OSP cables include requirements for pair-to-pair capacitance unbalance and far-end crosstalk, which are not specified parameters within the Category (CAT) 3 cable standards. In contrast, the TIA/EIA CAT 3 cable standard was designed primarily for premises installations, and specifically for local area network (LAN) applications with distance limitations. The typical data protocol used over CAT 3 cables, 10BASE-T Ethernet, has a maximum distance limit of 328 feet between electronics. This distance limitation is a function of the 50 microsecond round trip delay requirements of 10BASE-T Ethernet. Extend any CAT 3 cable run more than 328 feet and the cable has lost its CAT 3 designation and should not be used for 10BASE-T Ethernet transmissions. In an OSP environment, where distances typically exceed 328 feet, CAT 3 has very limited applicability to OSP cables. While Superior Essex copper OSP cables are not designed around the TIA 568A CAT 3 standard, they typically do meet the electrical requirements of CAT 3 and they are fully capable of carrying 10BASE-T Ethernet signals the maximum distance allowed by the standard 328 feet. However, aside from specific situations that require an outside plant 10BASE-T Ethernet network drop, CAT 3 has no relevance to the copper OSP cable used for POTS (Plain Old Telephone Service) or T1 applications. OSP Cable and Wire Applications Outside plant copper cable and wire products currently used throughout the United States are manufactured to specifications that have evolved through years of iterations of either Bellcore or RUS standardization activities. A typical loaded voice grade customer loop can be extended from the central office to the customer premises, potentially a distance of 100,000 feet or more. The cable has been designed for both short and long distance transmissions. Active transmission products placed on outside plant cable systems in use today have been designed to take full advantage of non-loaded outside plant cable products under the Bellcore or RUS standardization specifications. Higher frequency systems such as T1, T1-C, ISDN, HDSL, ADSL and VDSL are examples of transmission systems specifically intended for use on non-loaded standard outside plant cable products. Figure 1 shows the distance and data rate relationship for these protocols over copper and fiber. The improvement in both distance and data rate capacity per protocol is the result of electronics with improved noise/error correcting techniques. The protocols used over OSP cables are designed for point-to-point communications over long distances, as opposed to network protocols, (like Ethernet) which are designed to accommodate multiple users over short distances. This difference between protocols has resulted in key differences in electrical characteristics between OSP cables and LAN cables. Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 2 of 6

250 Previous Copper Limit Data Rate (Mb/s) 25 2.5 0.25 VDSL T-1 ADSL 8M Traditional Voice and Data Communications HDSL2 DDS Fiber Optic Transmission Current Copper Limit ADSL 1.5M ISDN Analog Modems 1 2 3 4 5 Loop Length (Miles) Figure 1: OSP Protocol Data Rates and Distances LAN Cable and Wire Applications Premises category-rated cables (CAT 3, 5, 5e and 6) are designed for high frequency transmission systems in indoor premises environment. Premises category-rated cables are capable of carrying several different protocols, the most common of which is Ethernet. CAT 3 cables can at most meet the requirements of 10BASE-T Ethernet (10 Mbps data rate) and have a maximum cable distance of 328 feet (including patch panel connections). CAT 5 cables are capable of carrying 100BASE-TX Ethernet (100 Mbps data rate) and CAT 5e cables are capable of carrying 1000BASE-T (Gigabit Ethernet). CAT 5 and 5e cables also are used for many other network protocols including 155 Mbps ATM and 622 Mbps ATM. The application versatility of CAT 5 and 5e cables has allowed them to virtually replace CAT 3 cables for network environments. This advantage for CAT 5/5e cables also applies to OSP LAN installations. CAT 5 and 5e cables designed for OSP installations are available from Superior Essex and are strongly recommended over cables with CAT 3 designation when a LAN protocol is planned to run over the installed cable. The data rate limitations of CAT 3 cables can restrict the network capacity unnecessarily, or worse, force an upgrade of the installed cable at considerable cost so that 100 Mbps Ethernet or Gigabit Ethernet may be employed. In contrast to most OSP protocols, LAN protocols (over copper twisted pairs) are typically distance restricted. This is mainly a consequence of the design of the Ethernet protocol. The Ethernet protocol is also called Carrier Sense Multiple Access with Collision Detection (CSMA/CD). Every set of rules is best understood by characterizing its worst case. The worst case for Ethernet starts when a Personal Computer (PC) at the extreme end of one wire begins sending data. The electric signal passes down the wire through repeaters, and just before it gets to the last station at the other end of the LAN, that station (hearing nothing and thinking that the LAN is idle) begins to transmit its own data. A collision occurs. The second station recognizes this immediately, but the first station will not detect it until the collision signal retraces the path all the way back through the LAN to its starting point. The time it takes for this to occur is called round trip delay (see Figure 2). Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 3 of 6

Collision Station 1 Station 2 Round Trip Delay Station 1 Station 2 Figure 2 Any system based on collision detection must control the time required for the worst-case round trip delay through the LAN. As the term Ethernet is commonly defined, this round trip is limited to 50 microseconds (millionths of a second). At a signaling speed of 10 million bits per second, this is enough time to transmit approximately 500 bits. At 8 bits per byte, this is about 64 bytes. To make sure that the collision is recognized, the Ethernet protocol requires that a station must continue transmitting until the 50 microsecond period has ended. If the station has less than 64 bytes of data to send, then it must pad the data by adding zeros at the end. In this way, it is possible to translate the 50 microsecond limit and other electrical restrictions into rules about cable length, number of stations, and number of repeaters. The maximum length of wire for an Ethernet LAN is 328 feet of copper wire including patch panel connections. However as the limit is worked out, it is ultimately a reflection of the constraint on the worst-case round trip delay due to the protocol employed. Category cables are highly specialized to ensure that any data transmissions are kept near the theoretical maximum speed of copper wire and that interference between copper pairs is minimized. The selection of improper insulation materials can slow down signals and could cause collisions because the round trip delay would have been exceeded at the maximum cable distances. 10,000 Data Rate (Mb/s) 1,000 100 10 1 UTP Copper Transmission Gigabit Ethernet 1000BASE-T Fast Ethernet 100BASE-T Ethernet 10BASE-T Fiber Optic Transmission Home Phone Line Networks 100 200 300 400 500 Wire Distance (Feet) Figure 3 Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 4 of 6

Differences The basic difference between LAN cable and OSP cable product design is the intended installation length. LAN cables are optimized for a maximum 100 meters (328 feet) installation distance. OSP cables are optimized for longer distances with load coil treatment as far as 100 thousand feet in length. Figures 1 and 3 are graphical representations of the difference between OSP cable and LAN cable capabilities for data rates and distances. Note the difference in scale between the two and the fact that OSP distances are nearly a magnitude of order longer than those for LAN s. The copper limits for data rates continue to increase as new technology in microprocessors allows more complex line code encryption, but distance constraints have remained constant for Ethernet protocols during this progression (see Figure 4). Terabit Ethernet Bit Rate ATM 155 Mb/s Gigabit Ethernet 10 Gb/s Gigabit Ethernet 1 Gb/s ATM 622 Mb/s Ethernet 10 Mb/s Token Ring 16 Mb/s CDDI 100 Mb/s Fast Ethernet 100 Mb/s 1979 1985 1993 1994 1995 1997 00 Figure 4: Local Area Network Data Rate Trends Parameters such as Structural Return Loss (SRL), Propagation Delay, Velocity of Propagation and Propagation Delay Skew are extremely important when transmitting high frequency signals over very short distances found in the premises LAN applications. As installation lengths increase, such as are found in the outside plant, these parameters offer little meaning. It must be noted that in all other electrical requirements, those for OSP are actually a bit tighter, mostly because OSP cables cover a much greater range of pair and gauge sizes as well as the longer installation lengths involved and temperature extremes. For example, OSP is tested for Far End Cross talk and Pair-to-Pair Capacitance Unbalance. Premises LAN product specifications do not include these requirements. As described above, there are logical differences in the end point transmission requirements of Premises and OSP systems based on the intended application environment. The below application chart shows the applicability of select Superior Essex cable types to each transmission application. Note that the LAN protocols are limited in all cases to less than 328 feet in distance. 02 Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 5 of 6

Transmission Application at 24 AWG Copper OSP Bellcore/ RUS Superior Essex Products by Application OSP Broadband CAT 5 OSP Broadband CAT 5e Premises CAT 3** Premises CAT 5e** Premises CAT 6** T-1 Yes Yes Yes Yes Yes Yes T1-C Yes Yes Yes Yes Yes Yes ISDN 192 Kb/s Yes Yes Yes Yes Yes Yes IDSL Yes Yes Yes Yes Yes Yes HDSL Yes Yes Yes Yes Yes Yes ADSL 1.5 Mb/s Yes Yes Yes Yes Yes Yes ADSL G.Lite Yes Yes Yes Yes Yes Yes SDSL 192 Kb/s Yes Yes Yes Yes Yes Yes VDSL 13 Mb/s Yes Yes Yes Yes Yes Yes RADSL Yes Yes Yes Yes Yes Yes HDS 1.5 Mb/s Yes Yes Yes Yes Yes Yes SHDSL Yes Yes Yes Yes Yes Yes HDSL2 1.5 Mb/s Yes Yes Yes Yes Yes Yes 10BASE-T* Ethernet Yes Yes Yes Yes Yes Yes 100BASE-T* Ethernet No Yes Yes No Yes Yes 1000BASE-T* Ethernet No No Yes No Yes Yes Yes = Product appropriate for application and distance No = Product not guaranteed for application and distance Consult transmission vendor during design phase for product details. *Distance transmission is limited to less than 328 feet. **Premises cables are not guaranteed for long distance transmission of OSP applications. Summary Aside from the specially designed CAT 5 and 5e OSP cables from Superior Essex, OSP copper cables have been designed around the applications used for long distance (over 20,000 feet) communications and not premises LAN applications. However, these OSP cables, while not guaranteed to meet all electrical specifications of CAT 3, are typically adequate for 10 Mbps Ethernet installations up to the maximum distance of 328 feet. Outside of this situation, the CAT 3 specification does not apply to the transmission requirements of protocols used in OSP applications and is not the proper standard to measure OSP cable capabilities. Toll Free 800.551.8948 Fax 770.657.6807 SuperiorEssex.com/Comm Page 6 of 6