Trinity Feature: T1/E1 Configuration



Similar documents
Trinity Feature: DSL Configuration

SRX 210 Services Gateway T1 Interface Configuration

Configuring E1 and T1 Interfaces

Configuring E1 and T1 Interfaces

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module

Chapter 4 T1 Interface Card

1. Overview. 2. F-bit Utilization

T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software

PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

This document describes the Livingston implementation of the Simple Network Management Protocol (SNMP) and includes the following topics:

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

Channelized E1 and Channelized T1 Setup Commands

Appendix D T1 Overview

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

! encor en etworks TM

Cisco T1 Layer 1 Troubleshooting

Loop-IP6700 TDMoEthernet

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

T3 Mux M13 Multiplexer

24-Port Channelized E1/T1 Line Card Overview

Tenor SNMP Implementation

- T-Carrier Technologies -

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

DS2155 T1/E1/J1 Single-Chip Transceiver

Event counters in NOVA

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Figure 1 - T1/E1 Internet Access

Network Management System and ICB Management System Software for T1 User s Guide

Atlas Event Logging Explanation

Loop-IP6700 TDMoEthernet

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

TDMoEthernet. Description

Quick Start Guide. Vpacket 5100/6100 Voice/Data Router SIP with PRI/ISDN Procedure Release 2.1.1

NetVanta Series (with Octal T1/E1 Wide Module)

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

Configuring T1 and E1 WAN Interfaces

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

WAN Module Installation and User Guide

SNMP Network Node Manager (NNM) Setup Guide

DXC Family. Multiservice Access Node FEATURES

Total Access SHDSL T1/E1 Line Terminating Unit Installation and Maintenance Practice

LifeSize Networker Installation Guide

G.703 Fractional T1 Access Unit. User Guide

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

2-port STM-1/OC-3 Channelized E1/T1 Line Card for Cisco Series Internet Routers

Bidirectional wireless communication using EmbedRF

ANT-20, ANT-20E Advanced Network Tester PDH MUX/DEMUX

TAM Port T1 Access Multiplexer

Software User Guide UG-461

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network

T-BERD 107A. T-Carrier Analyzer

BROADBAND AND HIGH SPEED NETWORKS

T1 Networking Made Easy

DS26303 OCTAL 3.3V T1/E1/J1 SHORT HAUL LIU PRODUCT BRIEF

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

PRI (T1/E1) Call Recorder User Manual Rev 1.0 (December 2013)

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

IPmux-1E TDM Pseudowire Access Gateway

ZLS50110/1/4. Demonstration Software User Guide. Revision Number: 1.0

Easy Smart Configuration Utility

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Cisco 2- and 4-Port Clear Channel T3/E3 Shared Port Adapters Version 2

Configuring Voice and Data Support on VWIC3s

Initial configuration Vega 400 E1/T1 (SIP)

The Common Test Patterns described below are used to test DS1 interfaces upon initial installation and after repair.

Initial configuration Vega 400 E1/T1 (H.323) Gatekeeper Mode R7

Loop-IP6702 TDMoEthernet

Octal T1-10/100 RIOP Installation Guide

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

Configuring Serial Interfaces

Troubleshooting Layer 2 Protocols over T1 Using the CLI

Cisco Channelized T1/E1 and ISDN PRI Modules

ADMINISTRATION GUIDE Cisco Small Business

Troubleshooting Layer 2 Protocols Over T1 Using the CLI

Loop-V4300 MINI DACS E1/ T1 CONVERTER

DAHDI User Guide. Schmooze Com Inc.

Cisco IOS Software Configuration for the 6-Port Channelized T3 (T1) Line Card

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

MicroLogix 1100 Embedded Web Server

BroadCloud Adtran Total Access Quick Start Guide

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

VALIANT COMMUNICATIONS LIMITED

OPERATION FIC SOC (USOC) JACK T1 CSU Interface 04DU9-1SN 6.0N RJ48C 04DU9-1ZN

PARADISE DATACOM APPLICATION NOTE CONTROL AND MONITOR OF DISTANT END TERMINAL USING LOCAL MODEM WEB USER INTERFACE EVO_AN_001

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

PDA Software Manual For the Windows CE and Mobile Operating Systems

Free-To-Guest (FTG) File Manager User Guide

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Managed Switch Quick Start Guide

How To. Configure E1 links. Introduction. What information will you find in this document?

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

Transcription:

Trinity Feature: Reference Guide Appendix Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com Part Number: 07MTRINT1E1-APD, Rev. C Revised: February 24, 2012

Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA tel: +1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007 web: www.patton.com e-mail: support@patton.com Copyright Copyright 2012, Patton Electronics Company. All rights reserved. Notice The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.

Appendix Chapter contents Overview...4 Configuration Overview...4 Web Management Interface (WMI)...6 Configure Clocking...6 Manage Ports...6 Port Configuration...7 Mode.... 7 Configuration Settings... 7 Data Channels... 8 Port Status...9 Port History...9 Line Interface (CLI)...10 Configuring the Clock Source...10 Selecting T1 or E1 Mode...10 Configuring T1 or E1 Applications...10 Creating Data Channels...11 Showing Configuration and Status...12 Clearing Errors and Performance History...13 Using Test Modes...13 3

Overview This chapter describes how to configure T1/E1 on the Trinity platform. Note The menu, commands, and features for your model may vary slightly from what is shown in this manual. Some models may not include all of the features mentioned. Refer to the model s User Manual, available online at www.patton.com/manuals, to see which features are available. Configuration Overview T1 and E1 ports are used for framing and signaling data. T1 and E1 are TDM protocols. T1 is used primarily in the USA. Its frame consists of 1 framing bit and 24 timeslots that can carry data. E1 is used in most other countries. Its frame consists of 1 timeslot used for frame synchronization and 31 timeslots that can carry data. In some models, the T1/E1 timeslots are mapped to data channels that can then be used to transport PPP packets. Configuring Data channels over the T1/E1 ports is done using the following steps: 1. Configure Clocking: T1/E1 clocking is a global setting - the clocking is used for all ports. Both the clock source and the fallback mode must be configured. Clock Source - Internal: Use the internal clock as the clock source at all times. - Primary/Secondary: Use the clock recovered from the primary port, the clock recovered from the secondary port, or the internal clock. When to use which clock source depends on the fallback mode and the link state of the primary and secondary ports. Fallback Mode None: Use the primary clock source while the port is up. Otherwise, use the internal clock. Fallback: Use the primary clock source until the port goes down. Then, use the secondary clock while the port is up, and the internal clock otherwise. To use the primary clock source again, the fallback condition must be manually reset. Fall-Forward: Use the primary clock source while the port is up. Use the secondary clock source while the primary port is down. Use the internal clock while both the primary and secondary ports are down. 2. Select the Mode: T1 or E1. Note You cannot change the mode while there are any data channels mapped to the port. 3. Configure the T1 or E1 Application: Configure framing, line code, application, line build out, and lossof-signal threshold. Enabled: Normal operation or power down the port. Framing: There are five framing formats available, two for T1 and three for E1: - D4 (T1 only) Overview 4

- ESF (T1 only) - Clear interface (E1 only): G.703. This is actually unframed. All timeslots carry data. - Basic Frame (E1 only): G.703/G.704. This can also be referred to as fractional. - CRC4 Multi-frame (E1 only) Line Code: There are three line codes available: - AMI (both T1 and E1) - B8ZS (T1 only) - HDB3 (E1 only) Application: This specifies the receiver sensitivity. Longer cables require greater receiver sensitivity. - Short-haul: Typically 655 feet and shorter cable length. - Long-haul: Typically longer than 655 feet cable length. Line Build Out: This only applies to T1 mode. It specifies the transmit pulse attenuation. This is used to prevent cross-talk in the far end. For short-haul applications, the value is set according to the cable length in feet. Valid settings are 0-133 ft., 133-266 ft., 266-399 ft., 399-533 ft., and 533-655 ft. For long-haul applications, the value is set in decibels. Valid settings are 0.0 db, -7.5 db, -15.0 db, and -22.5 db. LOS (Loss-of-Signal) Threshold: This only applies for long-haul applications, both in T1 and E1 mode. If the signal drops below the specified level, LOS will be reported. The level may be between -48 db and -4 db, inclusive. 4. Create data channels: Map data channels to selected T1 or E1 timeslots. These data channels can then be used as the transport for a PPP interface. The timeslots are specified using commas and dashes. For example: 1-3,5,7-8 maps the data channel to timeslots 1, 2, 3, 5, 7, and 8. Note You cannot remove a data channel while it is bound to a PPP interface. In addition to the above configuration, the following test modes are available: Local Analog Loopback: This is not useful for the 288x. Local Digital Loopback: This is not useful for the 288x. Network Loopback: This loops the clock and data received from the line back to the line. This can be used to allow the far end to run a bit error rate test (BERT) to test the link. To configure T1/E1 through the WMI, see the section Web Management Interface (WMI) on page 6. To configure T1/E1 through the CLI, see the section Line Interface (CLI) on page 10. Overview 5

Web Management Interface (WMI) To reach the main page, click on Interface Configuration > T1/E1 in the main menu. Figure 1. screen Configure Clocking To configure the clock source: 1. Choose an option from the Primary Clock drop-down menu. Internal: Use the internal clock as the clock source. Primary/Secondary: Use the clock recovered from the primary port, the clock recovered from the secondary port, or the internal clock. When to use which clock source depends on the fallback mode and the link state of the primary and secondary ports. 2. Select an option from the Fallback Mode drop-down menu. None: Use the primary clock source while the port is up. Otherwise, use the internal clock. Fallback: Use the primary clock source until the port goes down. Then, use the secondary clock while the port is up, and the internal clock otherwise. To use the primary clock source again, the fallback condition must be manually reset. Fall-Forward: Use the primary clock source while the port is up. Use the secondary clock source while the primary port is down. Use the internal clock while both the primary and secondary ports are down. Note The clock will fall-forward to the primary clock source when the primary clock source comes back up. 3. Click Update. Manage Ports To view the configuration screen for a T1/E1 port: 1. Click on the link of the port that you would like to configure in the Port column. 2. The link will lead to the port s status screen. On the port status screen, click on the Configuration tab. Web Management Interface (WMI) 6

Port Configuration Mode. To configure the mode of a port: 1. Choose either T1 or E1 from the Mode drop-down menu. Note When switching modes, you need to delete any existing data channels, and then create any desired data channels. 2. Click Update. Configuration Settings. To edit the configuration settings for a T1/E1 port: 1. Set the following options to configure a T1/E1 port: Enabled: Select Enabled to enable the port; select Disabled to disable a port. Framing: T1 Mode: Select D4 or ESF. E1 Mode: Select Clear interface, Basic Frame, or CRC4 Multi-frame. Line Code: T1 Mode: Select AMI or B8ZS. E1 Mode: Select AMI or HDB3. Application: Select Short Haul or Long Haul. Short Haul: Typically 655 feet and shorter cable length. Long Haul: Typically longer than 655 feet cable length. Line Build Out: For short-haul applications. select 0-133 ft., 133-266 ft., 266-399 ft., 399-533 ft., or 533-655 ft.. For long-haul applications. select 0.0 db, -7.5 db, -15.0 db, or -22.5 db. This only applies to T1 mode. It specifies the transmit pulse attenuation. This is used to prevent crosstalk in the far end. For short-haul applications, the value is set according to the cable length in feet. For long-haul applications, the value is set in decibels. LOS Threshold: Select from a range of even-numbered intervals between -4.0 db to -48.0 db. This only applies for long-haul applications, both in T1 and E1 mode. If the signal drops below the specified level, LOS will be reported. Loopback: Select Off, Local Analog, Local Digital, or Network. The Loopback options are test modes for T1/E1 configuration. The Network Loopback loops the clock and received data from the line and back to the line. This loopback mode can be used to allow the far end to run a bit error test to test the link. Web Management Interface (WMI) 7

2. Click Update. Figure 2. T1/E1 Port Configuration Settings Data Channels. To add a data channel: 1. Enter a number in the Channel field of the Data Channels table. This number is used to identify the channel. 2. Enter the number of timeslots in the Timeslots box. For T1 ports, the valid timeslots are from 1 to 24. For E1 ports, the valid timeslots are from 1 to 31 except when the framing type is clear-interface, in which case the timeslots must be exactly 0-31. 3. Enter a description (optional) (such as a location or other characteristic) in the Description field. If no description is specified, the system will use the default description (Data Channel). 4. Click the Add button in the Delete column. To delete a data channel: 1. Select the checkbox for the interface in the Delete column of the Data Channels table. 2. Click Delete. Figure 3. Adding and Deleting Data Channels Web Management Interface (WMI) 8

Port Status To view the status of a T1/E1 port: 1. Click on the link of the port that you would like to configure in the Ports table on the main T1/E1 page, or, from a port configuration page, click on the Status tab. 2. Click Clear Errors to clear and refresh the status of a port. Figure 4. Port Status Port History To view the history of a port: 1. Click on the link of the port that you would like to configure in the Ports table on the main T1/E1 page, or, from a port configuration page, click on the History tab. 2. Click Clear History to clear and refresh the history of a port. This will clear the performance history of the selected port, but not the error counters. Figure 5. Port History Web Management Interface (WMI) 9

Line Interface (CLI) Configuring the Clock Source Table 1. T1/E1 - Clock Source - CLI s Trinity# configure controller t1e1- clocking source primary internal Trinity# configure controller t1e1- clocking source primary <port> Trinity# configure controller t1e1- clocking source secondary <port> Trinity# configure controller t1e1- clocking mode {no-fallback fallback fallforward} Trinity# configure controller t1e1- clocking reset fallback Trinity# configure controller t1e1- clocking show Set the clock source as internal. All ports slave from the internal clock. In internal clock mode, the secondary clock source and fallback mode are ignored. Select a primary clock source. Select a secondary clock source. Select the fallback mode. Manual reset fallback. This is only valid if the fallback mode is set to fallback. Show the clocking settings. Selecting T1 or E1 Mode Table 2. T1/E1 - Mode - CLI s Trinity# configure controller t1e1 <port> Trinity[t1e1-0]# mode {t1 e1} Enter the configuration mode for the specified port. Select T1 or E1 mode. Configuring T1 or E1 Applications Trinity[t1e1-0]# framing {d4 esf clear-interface fractional crc} Trinity[t1e1-0]# [no] shutdown Trinity[t1e1-0]# line-code {ami b8zs hdb3} Trinity[t1e1-0]# application {short-haul long-haul} Trinity[t1e1-0]# line-build-out {0-133 133-266 266-399 399-533 533-655 0.0-7.5-15.0-22.5} Table 3. T1/E1 - Applications - CLI s Set the framing. D4 and ESF are valid T1 frames. Clear-interface (G.703), fractional (G.703/G.704), and CRC4 Multiframe are valid E1 frames. Power up/down the port. Set the line code. AMI is valid for both T1 and E1. B8ZS is valid for T1 only. HDB3 is valid for E1 only. Select short haul (typically less than 655 feet cable) or long haul application. Set the line build out in order to prevent cross-talk in the far end. This is only valid in T1 mode. Line Interface (CLI) 10

Table 3. T1/E1 - Applications - CLI s Trinity[t1e1-0]# los-threshold <-48 - -4> Set the loss-of-signal threshold in db. This is only valid in longhaul applications (both T1 and E1). Creating Data Channels Table 4. T1/E1 - Data Channels - CLI Trinity[t1e1-0]# channel <id> timeslots <timeslots> Map the specified timeslots to a data channel. Timeslots should be specified using dashes and commas. For example, 1-3,5,7-8 specifies timeslots 1, 2, 3, 5, 7, and 8. In T1 mode, the valid timeslots are from 1 to 24. In E1 mode, the valid timeslots are from 1 to 31 except when framing is clear-interface, in which case the timeslots must be exactly 0-31. Once the data channel is created, a PPP interface can use it. Note When changing between T1 and E1 modes, the data channels are no longer valid for two reasons: The timeslots may be invalid. For example, 1-31 is a valid timeslot selection for E1, but not for T1. The same T1/E1 timeslot maps to a different timeslot internally on the pulse-code modulation (PCM) highway. A data channel should not be deleted if a PPP interface is using it. Line Interface (CLI) 11

Showing Configuration and Status Table 5. T1/E1 - Show Configuration & Status - CLI Trinity[t1e1-0]# show Trinity# show controller t1e1 0 Enter the show mode. Show the configuration, the status, and the data channels. configuration: t1 esf (b8zs) short-haul, 0.0 db line build out normal operation status: link up alarms: clear errors: lcv=0 pcv=0 lcv=0 pcv=0 cs=0 data channels: channel 0 : 1-24 Trinity[t1e1-0]# show history Show the performance history counters (most recent at the top). ES SES SEFS UAS CSS LES BES DM ------ ------ ------ ------ ------ ------ ------ ------ 1: 0 0 0 0 0 0 0 0 2: 0 0 0 0 0 0 0 0 3: 0 0 0 0 0 0 0 0 4: 0 0 0 0 0 0 0 0 5: 7 0 0 0 7 7 0 0 Trinity# show interface data [<interface>] If an interface is not specified, show all data channels and their port/timeslot map. If an interface is specified, show packet counters. channel 0 is up, line protocol is up MTU 9236 ARP disabled Multicast disabled Rx Statistics 0 bytes in 0 packets 0 errors 0 drops, 0 overruns 0 multicast packets Tx Statistics 180 bytes in 10 packets 0 errors 0 drops, 0 collisions 0 carrier errors Line Interface (CLI) 12

Clearing Errors and Performance History Table 6. T1/E1 - Clearing Errors - CLI Trinity[t1e1-0]# clear errors Trinity[t1e1-0]# clear history Clear all status for the selected port. This will clear not only error counters, but also performance history. Clear the performance history for the selected port, but leave the error counters unaffected. Using Test Modes Table 7. T1/E1 - Test Modes - CLI Trinity[t1e1-0]# loopback {off localanalog local-digital network} Start or stop a loopback.the network loopback will loop data received on the line back to the line. Line Interface (CLI) 13