MK Application. Features. Applicable Literature. Pneumatic Valve Actuator General Instructions

Similar documents
POWERS Controls No. 4 Pneumatic Damper Actuator

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

MP8000 Series Pneumatic Valve Actuators

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat

Fisher 657 and 667 Diaphragm Actuators

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

POWERS CONTROL RC 195 Single Input Receiver-Controller

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Baumann Way Bronze or Stainless Steel Control Valve

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

RC 195 Multiple Input Receiver-Controller

Part I - Installation

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

WE-350 Series ¼ Turn Electric Actuator

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Dissolved Oxygen Sensors

1805 Series Relief Valves

VG7000 Series Bronze Control Valves

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Operating Instructions

Retrofit with Siemens

Fisher 377 Trip Valve

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Submersion/Insertion Toroidal Sensor

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Baumann Mikroseal Control Valve

Fisher 249 Caged Displacer Sensors

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Your safety and the safety of others are very important.

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

CEILING CASSETTE FAN COIL UNIT

167D Series Switching Valves

Multipurpose Ball Valves

General Purpose ph/orp Sensors

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Product/Technical Bulletin

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

KNC Model 3666 Automatic Pressure Calibration System

SELECTION, APPLICATION & MAINTENANCE

Series 71, 72, and 76 Modutrol IV Motors

How To Drive A Compact Serie 1

PNEUMATIC CONTROLS Selection and Description

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Baumann Flexsleev Sanitary Control Valve

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

VG2000 Series Cast Iron Flanged Globe Valves

A-4000 Oil Indicator

Type 119 Control Valve

Pneumatic Actuators. Crafted without compromise, to make your life easier. The Leader in Actuator Technology

High Performance Visible Laser Diode Scanners

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Connecting the Channel A

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

IOM SERIES 820-E/P Electro-Pneumatic Positioner

V46 Pressure-Actuated Water-Regulating Valve

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Solenoid Valve Type 3962

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Reaction Torque Sensor

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Baumann Little Scotty Bronze Control Valve

Absolute Rotary Encoder E6CP

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

Bubble King. User Manual

LED...A Q Series Sealed High-Intensity

MODEL G300 BRAKE BLEEDER

A99B Series Temperature Sensors

IMPORTANT DOCUMENTATION DO NOT DISCARD!

AMPSEAL* Automotive Plug Connector and Header Assembly

2006 JUDY SERVICE GUIDE

T5000 T000 LCD Digital Fan Coil Thermostat

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Access Server Rack Cabinet Compatibility Guide

Series Hose Reels

Model 43AP Pneumatic Controller, Style B

V47 Series Temperature Actuated Modulating Water Valves

Projector Dowser Userʼs Manual Part # 4160

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Y7230A CO 2 Alarm System

2006 HEADSHOK Service Video #1

VOYAGER 570G. 744A Sprayer Control

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CETAC Z-Drive Assembly

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

TECHNICAL DATA. Dry 122a. November 12, 2013

Transcription:

MK-2690 Pneumatic Valve Actuator General Instructions Application For proportional pneumatic control of 1/2" to 1-1/4" VB-111 and VB-9xxx series valves. Features Compact size with 6 in. 2 (39 cm 2 ) effective area. Rugged die cast aluminum housing. Replaceable beaded molded neoprene diaphragm. Applicable Literature Environmental Controls Cross-Reference Guide F-23638 Environmental Controls Reference Manual F-21683 Environmental Controls Application Manual F-21335 AV-400 Valve Linkage General Instructions F-19073 Printed in U.S.A. 1/10 Copyright 2010 Schneider Electric All Rights Reserved. F-13893-7

SPECIFICATIONS Actuator Inputs Compatible With: Proportional pneumatic signal. See Table-1. Start Point, Non-adjustable. Air Connections: 1/8" FNPT located on side of housing. Actuator Outputs Mechanical: Stroke, 1/2" (12.6 mm) nominal. Environment Ambient Temperature Limits: Shipping, -40 to 220 F (-40 to 104 C). Operating, -20 to 220 F (-29 to 104 C). Humidity: 5 to 95% RH, non-condensing. Location: NEMA Type 1 indoor only. Maximum Air Pressure: 30 psig (207 kpa). Spring: Retracts actuator shaft and raises valve stem on loss of air pressure. Springs provided in AV-400 linkage (order separately). Table-1 Spring Ranges. Actuator Part Number MK-2690 psig Nominal Spring Range* (Spring Color Code) kpa 3 to 7 (Yellow) 21 to 48 5 to 10 (Black) 34 to 69 8 to 13 (Blue) 55 to 90 *Nominal (no load) condition, spring ranges based on 1/2" (13 mm) maximum stroke, provided by AV-400 linkage (order separarely). ACCESSORIES AK-42309-500 Positive positioner and linkage; use with MK-2690-0-0-1 or MK-2690-0-0-2 models only AV-400 Valve linkage TOOLS TOOL-95-1 Pneumatic calibration tool kit MAINTENANCE PARTS PNV-102 Diaphragm 2 Copyright 2010 Schneider Electric All Rights Reserved. F-13893-7

INSTALLATION Inspection Requirements Mounting Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. Job piping diagrams Tools (not provided): 1-5/8" open-ended wrench Appropriate screwdriver Training: Installer must be a qualified, experienced technician CAUTION: Make all connections in accordance with the piping diagram. Do not exceed ratings of the device(s). Avoid locations where excessive moisture, corrosive fumes, or vibration is present. The MK-2690 is generally installed in an upright position. When connecting to the control air line the actuator may be swiveled to any convenient position above the center line of the valve body. N O T E The actuator should be removed from the valve body during valve installation. Installing Actuator on Valve Body 1. Position actuator assembly over valve stem and spring and secure with mounting nut. (See Figure-1.) 2. Swivel actuator to convenient position for piping. 3. Connect air supply to actuator. For information on valve linkage assembly, see General Instructions for AV-400 linkage (F-19073). Mounting Nut Figure-1 Actuator Assembled to Valve Body with Linkage. Removing Actuator from Valve Body 1. Loosen mounting nut. (See Figure-1.) 2. Lift actuator straight up until it clears the valve spring. N O T E When removing the actuator, make sure that the piston is not pulled out of the diaphragm. 3. Lay the actuator on its top until it is to be installed. F-13893-7 Copyright 2010 Schneider Electric All Rights Reserved. 3

MAINTENANCE FIELD REPAIR Regular maintenance of the total system is recommended to assure sustained optimum performance. Replacing Actuator Diaphragm 1. Disconnect air supply to actuator. 2. Loosen mounting nut. (See Figure-3.) 3. Lift the actuator off the valve body and linkage. 4. Place actuator on its top, and remove two (2) lower housing screws. Remove lower housing. 5. Remove piston from actuator. 6. Turn actuator housing over and remove the diaphragm retaining screws. 7. Remove diaphragm and its retainer from actuator housing by pulling them straight out from housing. (See Figure-2 and Figure-3.) 8. Remove diaphragm retainer from old diaphragm and install new diaphragm. 9. Place diaphragm and retainer in housing and secure with two screws. 10. Place the actuator housing on its top (open side up) and center the piston on the diaphragm. (See Figure-2.) 11. Pull protrusions on diaphragm through mating holes on piston. (See Figure-2.) 12. Push the piston down evenly, rolling diaphragm around piston. Be certain to position the piston squarely on diaphragm with equal distances from piston to housing sides. (See Figure-2.) 13. Install lower housing to the actuator housing with two retaining screws. 14. The actuator is now assembled. (See Figure-1.) 15. Install actuator on valve body. Actuator Housing Piston Diaphragm evenly positioned around piston Diaphragm Diaphragm Retainer Diaphragm Retainer Screws Figure-2 Positioning Piston in Diaphragm (shown with actuator in the inverted position). 4 Copyright 2010 Schneider Electric All Rights Reserved. F-13893-7

Diaphragm Retainer Screws Actuator Housing Diaphragm Retainer Diaphragm Piston Lower Housing Lower Housing Screws Valve Body Mounting Nut Figure-3 Exploded View of MK-2690. F13893-7 Copyright 2010 Schneider Electric All Rights Reserved. 5

DIMENSIONAL DATA All dimensions in inches (millimeters in brackets). See Figure-4. Top View 2-1/4 (57) 3-9/16 (90) 5 (127) Side View Figure-4 MK-2690 Pneumatic Actuator. 6 Copyright 2010 Schneider Electric All Rights Reserved. F-13893-7

F-13893-7 Copyright 2010 Schneider Electric All Rights Reserved. 7

On October 1st, 2009, TAC became the Buildings business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. Copyright 2010, Schneider Electric All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. F-13893-7 Schneider Electric 1354 Clifford Avenue P.O. Box 2940 Loves Park, IL 61132-2940 www.schneider-electric.com/buildings