SITRANS T measuring instruments for temperature

Similar documents
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

J TB/TW Temperature limiter, temperature monitor

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Combining perfect senses and intelligence for every degree and condition

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. Dimensions

Solenoid Valve Island Type 3965

Technical Information RIA14

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. Dimensions

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

2.12. page Products for Explosion hazardous Environment

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

3DLevelScanner II TECHNICAL DATA SHEET

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

SITRANS F flowmeters SITRANS F M

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

TEIP11 I/P signal converter for standard signals. Measurement made easy

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Redundancy Module QUINT-DIODE/40

Duct Humidity Transmitter

Rosemount 333 HART Tri-Loop

Triple Waveband Infra-Red Flame Detection

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Differential Charge Amplifier

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

CompactLogix Power Supplies Specifications

Pressure transmitter For general industrial applications Model A-10

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Instruction Manual. T3111 T3111L T3111P T3111Ex

SITRANS F flowmeters SITRANS F M. Transmitter MAG 5000/ /32 Siemens FI Overview

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 333 HART Tri-Loop

Linear Luminaire with LED Series EXLUX 6402/2

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Type testing

Waveguide Access Point WGA631. Product Guide

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Design. Function. Transmitter. Operating and display panel. HART communication. Master

Electronic Pressure Switch EDS 300

How To Use A Flowmeter

RTD Temperature Probe for the Food/Pharmaceutical Industry

Vario-Series Accessories

1788 Linking Device Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

FCS-MBx-SG Megablock series*

Rosemount 751 Field Signal Indicator

Digital inductive conductivity transmitter

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

MINI MCR-SL-R-UI(-SP)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

T0118 T2118 T3118. Instruction Manual

Analog signal converters CC-E I/I Current / current isolators

TTF300 Field-mount temperature transmitter

TTH300 Head-mount temperature transmitter

Terminal Boxes Series 8146

Compact pressure switch Flameproof enclosure Ex d Model PCA

Explosion proof enclosures

1756 ControlLogix Chassis Specifications

Plastic tube flowmeters Series PT/PS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Series 8146/5-V37 and Series 8150/5-V37

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Digital input modules

SEISMIC VELOCITY TRANSDUCER T1-40

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Flow switches Series AD/VH

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

HERZ-Thermal Actuators

S300 Series Dust Monitors

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

DS 600. A contact free flux gate based current measurement sensor 600A rms

SITRANS F flowmeters SITRANS FUS080. Flowmeter FUE380 with approval. 4/202 Siemens FI Overview

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

NX safety stand-alone

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Transcription:

Overview Siemens AG 009 Wide range of approvals for use in potentially explosive atmospheres. "Intrinsically safe, non-sparking and flameproof" type of protection, for Europe and USA Our field devices for heavy industrial use FOUNDATION fieldbus PROFIBUS PA The temperature transmitter works where others can t cope. Benefits For universal use as a transmitter for resistance thermometers, thermocouple elements, Ω or mv signals Rugged two-chamber enclosure in die-cast aluminium or stainless steel Degree of protection IP67 Can be mounted elsewhere if the measuring point - is not easily accessible - is subject to high temperatures - is subject to vibrations from the system - or if you want to avoid long neck tubes and/or protective tubes Can be mounted directly on American-design sensors Application The can be used everywhere where temperatures need to be measured under particularly harsh conditions. Which is why users from all industries have opted for this field device. The rugged enclosure protects the electronics. The stainless steel model is even resistant to sea water and other aggressive elements. The inner workings offer high measuring accuracy, universal input and a wide range of diagnostic options. Function Features General Polarity-neutral bus connection 4-bit analog-digital converter for high resolution Electrically isolated Version for use in hazardous areas Special characteristic Sensor redundance Transmitter with PROFIBUS PA communication Function blocks: x analog Transmitter with FOUNDATION fieldbus communication Function blocks: x analog and x PID Functionality: Basic or LAS Mode of operation The following function diagram explains the mode of operation of the transmitter. The only difference between the two versions of the (7NG7-... and 7NG8-...) is the type of field bus protocol used (PROFIBUS PA or FOUNDATION fieldbus). Optional inputs: - Resistance thermometer - Thermocouple - mv sensor - Resistance-based sensors Transformer Input Input Differential Mean value Redundancy Terminal temperature Engineering units Diagnostic functions Table linearization Polynomial linearization Process calibration 6 Electrically isolated Input Input 5 4 A/D converter CPU Communication Ex power circuit Bus connection Internal Pt00 EEPROM Complex configuration Correction coefficient Factory settings - PROFIBUS PA protocol (7NG7) or - FOUNDATION Fieldbus protocol (7NG8) with TH400, function diagram Siemens FI 0 00 /65

Siemens AG 009 System communication Bus terminator Bus terminator with TH400 PA with TH400 FF with TH400, communication interface Technical specifications Input Analog/digital conversion Measurement rate Resolution Resistance thermometer Pt5... Pt000 to IEC 6075/JIS C 604 Measuring range Ni5... Ni000 to DIN 4760 Measuring range Cu0... Cu000, α = 0.0047 Measuring range Line resistance per sensor cable Sensor current Sensor fault detection Sensor break detection Sensor short-circuit detection Resistance-based sensors Measuring range Line resistance per sensor cable Sensor current Sensor fault detection Sensor break detection Sensor short-circuit detection <50ms 4-bit -00... +850 C (-8... +56 F) -60... +50 C (-76... +48 F) -50... +00 C (-58... +9 F) Max. 50 Ω Nominal 0. ma Yes Yes, < 5 Ω 0 Ω... 0 kω Max. 50 Ω Nominal 0. ma Yes Yes, < 5 Ω PROFIBUS PA Segment coupler FOUNDATION Fieldbus Segment coupler Thermocouple To IEC 584 Type B Type E Type J Type K Type N Type R Type S Type T to DIN 470 Type L Type U to ASTM E988-90 Type W Type W5 External cold junction compensation Sensor fault detection Sensor break detection Sensor short-circuit detection Sensor current in the event of open-circuit monitoring mv sensor - voltage input Measuring range Input resistance Output Filter time (programmable) Update time Measuring accuracy Accuracy is defined as the higher value of general values and basic values. General values Type of input All Measuring range 400... 80 C (75... 08 F) -00... +000 C (-48... +8 F) -00... +000 C (-48... +8 F) -00... +00 C (-48... +9 F) -80... +00 C (-9... +7 F) -50... +760 C (-58... +00 F) -50... +760 C (-58... +00 F) -00... +400 C (-8... +75 F) -00... +900 C (-8... +65 F) -00... +600 C (-8... + F) 0... 00 C (... 47 F) 0... 00 C (... 47 F) -40... +5 C (-40... +75 F) Yes Yes, < mv 4 µa -800... +800 mv 0 MΩ 0... 60 s < 400 ms Absolute accuracy ±0.05 % of measured value Temperature coefficient ±0.00 % of measured value/ C Basic values Type of input Basic accuracy Temperature coefficient Pt00 and Pt000 ±0. C ±0.00 C/ C Ni00 ±0.5 C ±0.00 C/ C Cu0 ±. C ±0.0 C/ C Resistance-based sensors ±0.05 Ω ±0.00 Ω/ C Voltage source ±0 µv ±0. µv/ C Thermocouple, type: ±0.5 C ±0.0 C/ C E, J, K, L, N, T, U Thermocouple, type: ± C ±0.05 C/ C B, R, S, W, W5 Cold junction compensation ±0.5 C /66 Siemens FI 0 00

Siemens AG 009 Reference conditions Warming-up time Signal-to-noise ratio 0 s Min. 60 db Calibration condition 0... 8 C (68... 8 F) Conditions of use Ambient conditions Permissible ambient temperature -40... +85 C (-40... +85 F) Permissible storage temperature -40... +85 C (-40... +85 F) Relative humidity 98 %, with condensation Insulation resistance Test voltage 500 V AC for 60 s Continuous operation 50 V AC/75 V DC Electromagnetic Compatibility NAMUR NE EMC 004/08/EC Emission and EN 66-, EN 66--5 Noise Immunity Design Weight Approx..5 kg (. lb) without options Dimensions See "Dimensional drawings" Enclosure materials Die-cast aluminium, low in copper, GD-AlSi or stainless steel Polyester-based lacquer for GD AlSi enclosure Stainless steel rating plate Electrical connection, sensor connection Mounting bracket (optional) screw terminals Cable inlet via M0 x.5 or ½-4 NPT screwed gland Bus connection with M plug (optional) Steel, galvanized and chromeplated or stainless steel Degree of protection IP67 to EN 6059 Auxiliary power supply Power supply Standard, Ex "d", Ex "na", Ex "nl", 0.0... V DC XP, NI Ex "ia", Ex "ib" 0.0... 0 V DC In FISCO/FNICO installations 0.0... 7.5 V DC Power consumption < ma Max. increase in power consumption in the event of a fault < 7 ma Certificates and approvals Explosion protection ATEX EC type test certificate ZELM 99 ATEX 0007 Type of protection II () G Ex ia IIC T4/T6 "intrinsic safety i" (version: 7NGx-xxxx) Conformity statement ZELM 07 ATEX 49 "Operating equipment that is nonignitable and has limited energy" type of protection (version: 7NGx-xxxx) II G Ex na [nl] IIC T4/T6 II G Ex nl IIC T4/T6 EC type test certificate CESI 99 ATEX 079 "Flame-proof enclosure" type of II G Ex d IIC T5/T6 protection (version: 7NGx- 4xxxx) Explosion protection: FM for USA FM approval FM 0774 Type of protection XP, DIP, NI and S XP / I / / BCD / T5,T6; Type 4X (version 7NGx-5xxxx) DIP / II, III / / EFG / T5,T6; Type 4X NI / I / / ABCD / T5,T6; Type 4X S / II, III / / FG T5,T6; Type 4X Communication Parameterization interface PROFIBUS PA connection - Protocol A&D profile, Version.0 - Protocol EN 5070 Volume - Address (for delivery) 6 - Function blocks x analog FOUNDATION fieldbus connection - Protocol FF protocol - Protocol FF design specifications - Functionality Basic or LAS -Version ITK 4.6 - Function blocks x analog and x PID Factory setting For SITRANS TH400 PA Sensor Pt00 (IEC) Type of connection -wire circuit Unit C Failure mode Last valid value Filter time 0 s PA address 6 PROFIBUS Ident No. Manufacturer-specific For SITRANS TH400 FF Sensor Pt00 (IEC) Type of connection -wire circuit Unit C Failure mode Last valid value Filter time 0 s Node address Siemens FI 0 00 /67

Siemens AG 009 Selection and ordering data Order No. Temperature transmitter in field enclosure 7 N G 7-7 770 7 with fieldbus communication and electrical isolation, with documentation on CD Integrated transmitter SITRANS TH400 with PROFIBUS PA - without Ex protection 7 0 - with EEx ia (ATEX) 7 - with EEx nal for zone (ATEX) 7 - total device EEx d ) 7 4 - total device according to FM 7 5 (XP, DIP, NI, S) ) (available soon) SITRANS TH400, with FOUNDATION fieldbus - without Ex protection 8 0 - with EEx ia (ATEX) 8 - with EEx nal for zone (ATEX) 8 - total device EEx d ) 8 4 - total device according to FM 8 5 (XP, DIP, NI, S) ) (available soon) Enclosure die-cast aluminium A stainless steel precision casting E Connections/cable inlet screwed glands M0x.5 B screwed gland s ½-4 NPT C Mounting bracket and fastening parts none 0 made of steel stainless steel Further designs Order code Please add "-Z" to Order No. and specify Order code(s) and plain text. Customer-specific operating data Y0 ) Inscription on measuring point label Measuring point number/tag (max. char.) Y 5 ) Measuring point description (max. char.) Y ) Bus address Y 5 ) Test report (5 measuring points) C 4) Bus connection M plug (metal), without mating connector M 0 0 5) M plug (metal), with mating connector M 0 5) ) Without cable gland. ) Y0: Please specify all data that does not correspond to factory settings (see above) (e.g. Y0 = thermocouple element type K; internal cold junction; PA address: 5). ) Y5, Y, Y5: If no order is placed for Y0, these data are only noted on the measuring point label and are not programmed in the transmitter. 4) Can only be ordered together with Y0 (it is essential to specify the measuring range). 5) Not available for explosion protection EEx d or XP. Selection and ordering data Order No. Accessories CD for measuring instruments for temperature A5E00645 with documentation in German, English, French, Spanish, Italian and Portuguese, and parameterization software SIPROM T (included in delivery with ) SIMATIC PDM parameterization software see Sec. 9 also for with TH400 PA Mounting bracket and fastening parts Made of steel for 7NG.-..B.. 7MF4997-AC Made of steel for 7NG.-..C.. 7MF4997-AB Made of stainless steel for 7NG.-..B.. } 7MF4997-AJ Made of stainless steel for 7NG.-..C.. 7MF4997-AH Connection board A5E09790 }Available ex stock. Factory setting: for SITRANS TH400 PA: - Pt00 (IEC) with -wire circuit - Unit: C - Failure mode: last valid value - Filter time: 0 s - PA address: 6 - PROFIBUS Ident No.: manufacturer-specific for SITRANS TH400 FF: - Pt00 (IEC) with -wire circuit - Unit: C - Failure mode: last valid value - Filter time: 0 s - Node address: /68 Siemens FI 0 00

Siemens AG 009 Dimensional drawings 44 (5.67) 8* (5.4) 5 (.05) 50* (.97) 55 (.7) 8 (.0) 0 (0.79) b 80 (.5) 00* (.94) 6 Ø 80 (.5) 5 4 7 (.8) 50 (.97) 7 (4.6) 68 (.68) 0 (4.7) a 6,5 (.44) 7 (9.) (4.84) Ø 50... 60 (.97....6) Sensor connection (screwed gland M0x,5 or ½-4 NPT) Blanking plug Electrical connection (screwed plug M0x,5 orr ½-4 NPT), optional M plug 4 Terminal side, bus connection 7 05 (4.) 5 Terminal side, sensor 6 Protective cover (without function) 7 Mounting bracket (optional) with clamp securing to a vertical or horizontal pipe with TH400, dimensions in mm (inches) Siemens FI 0 00 /69

Schematics Siemens AG 009 Resistance thermometer Thermocouple Resistance Two-wire system ) Internal cold junction compensation Two-wire system ) Three-wire system Cold junction compensation with external Pt00 in two-wire system ) Three-wire system Four-wire system Cold junction compensation with external Pt00 in three-wire system Four-wire system Mean-value/differential or redundancy generation x two-wire system ) Mean value, differential or redundancy generation with internal cold junction compensation Mean value, differential or redundancy generation resistor in two-wire system ) resistor in three-wire system Voltage measurement Mean-value/differential or redundancy generation sensor in two-wire system ) sensor in three-wire system Mean value, differential or redundancy generation and cold junction compensation with internal Pt00 in two-wire system ) One voltage source ) Programmable line resistance for the purpose of correction. Measurement of mean value, differential and redundancy with voltage sources with TH400, sensor connection assignment /70 Siemens FI 0 00