LFS / LFS-mA CONFIGURATION

Similar documents
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

IntesisBox KNX LG Air Conditioning

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

MLC TM Maximum Productivity and Versatility for Control without Compromise!

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

+ A B V B NO NC V COM PV PV

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

J TB/TW Temperature limiter, temperature monitor

Multi-Range Programmable DC Power Supplies 9115 Series

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

PRODUCT PROFILE FEATURES

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

Model: DC-A2IO Advanced HVAC Controller

Multi-Range Programmable DC Power Supplies 9115 Series

PIEZOMETER AIRFLOW MEASURING RING

HERZ-Thermal Actuators

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Power Meter Series 700

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Safety technique. Emergency stop module BO 5988 safemaster

T0118 T2118 T3118. Instruction Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electronic Control Devices The European Product Catalogue 2007

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

Digital Pressure Measuring Instrument MDR480

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

IntesisBox KNX Mitsubishi Heavy Industries AC

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

KNX Panasonic Air Conditioners

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

NC-12 Modbus Application

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Programming Logic controllers

1 Serial RS232 to Ethernet Adapter Installation Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Short information Parameters are programmed via front-side membrane keypad

Dyeing Programmer DP - 01

Contents. Document information

TC 1818a. Operating Guide. Control Module SWM-015.5

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Wahl C50 Calibrator FEATURES

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

1.44 kw Programmable DC Power Supplies XLN Series

UDC2500 Universal Digital Controller. Specification. Overview. Features. Analog Inputs /04 Page 1 of 13

THERMAL MANAGEMENT SOLUTIONS

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Quick Connect. quick - simple - efficient.

ACS-30-EU-EMDR-10-MOD

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

MODEL T48-1/16 DIN TEMPERATURE CONTROLLER

User Manual Auto Tuning PID Temperature Controller

TC-9102 Series Surface Mount Temperature Controllers

CompactLogix Power Supplies Specifications

Voltage Regulator SPAU 341 C. Product Guide

IntesisBox KNX Modbus RTU master

Smart DeviceNet Remote I/O Terminals

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Process Alarm Solutions

MOUNTING AND OPERATING INSTRUCTIONS

Digital input modules

Transmitter Interface Program

CQM1-SF200/CS1W-SF200

Multifunction devices

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Transcription:

LFS / LFS-mA IP 65 (*) and NEMA 4X (*) front protection. SMART function for the self-tuning of control parameters. Proprietary algorithm for heating/cooling control with automatic setting of control parameters according to the selected cool transferring media (air, oil or water). Universal input (TC, RTD, mv, ma, 5V and 10V). Up to 2 independent alarms programmable as process alarm, band alarm or deviation alarm with automatic or manual reset of the alarm condition. Masking of the alarms during start up or after a set-point change. Manual control mode, output can be set in % of the power. 2 independent ramps (ramp up and ramp down) for set point change. Output failure detection alarm with load current measurement (OFD function). (*) Test were performed in accordance with CEI 70-1 and NEMA 250-1991 STD. CONFIGURATION By front keyboard or through RS 485 serial link How to order the configuration program - For LFS relay: 6ER.LFS.RLY.CON - For LFS-mA: 6ER.LFS.0MA.CON 2

SDDE - DDE Communication Driver for ERO Devices How can you simply interface ERO instruments to a PC running Windows? Now it is quick and inexpensive by using SDDE driver developed by ERO Electronic to make available as Windows objects the process data handled by the instruments as well as their run-time and configuration parameters. The integration of Ero instruments in the Windows work environment allows to link them to any Windows based package (In- Touch, Fix, Us-Data, Lab-View), or to build up your own application by using any other tool like Visual Basic, Excel, Word. HOW TO ORDER Protocol type: MODBUS 6ER.SDD.EMT.LFS polling/selecting 6ER.SDD.EDR.VOO PROGRAMMABLE PROTOCOLS ModBus, JBus, ERO (RS 485) AUTO TUNING AND SELF-TUNING FUNCTION These instrument are equipped with a proprietary self-tuning algorithm named SMART. During start-up and control, monitoring continuously the process variable, the smart is able to adjust automatically the P.I.D. parameters according to the response of the process variable. The advantage of this continuous self-tuning algorithm is the ability to operate without injecting any artificial change into the system. During start-up The SMART implements the selftuning function calculating the value of the P.I.D.parameters in order to optimize the set point approach and decrease overshoot. During control The SMART implements the selftuning function updating, if necessary, the P.I.D. parameters according to the type of response due to a set point change or to a load change. 3

LFS / LFS-mA Output Programmable output level limiter Start-up Programmable time duration of the output level limiting Programmable output maximum rate of change Time Soft Start function This function allows to gradually pre-heat the controlled process in order to increase the heater life. In order to use this function, it is necessary to program the level of power output to be used during pre-heating and its time duration. The alarm masking function assures that no false indication will occur during pre-heat. With these instruments is also possible to program the output power maximum rate of change in order to avoid thermal shock during normal operation. Set point Two independent and programmable ramp (up and down ramp) for set point changes Time Two independent ramps (ramp up and ramp down) for set point changes This product family allows to program a ramp for increasing a set point and a ramp for decreasing a set point. This solution is essential where it is necessary to produce a gradual set point variation. Moreover, a process may need an heating speed different from cooling. First set point change Second set point change Read-out Programmable constant offset Adjusted curve Real curve Measure OFFSET on the measured value These instruments offer the possibility to program a constant offset applied to the measured value in order to re-align the measured value with the real value of the process. Ex. In many cases it is quite difficult to place your sensor in an ideal position. The incorrect positioning of the sensor may produce a measured value that is not a true representation of the process value. REAR OF BOARD VERSION 4 The LFS family product encompasses also the rear of board version for omega DIN rail mounting in accordance with EN 50022 (35 x 7.5 mm or 35 x 15 mm). This version was designed in order to simplify the installation, to reduce the panel space and to reduce the wiring cost. Furthermore the rear of board mounting will protect the instrument from possible tampering with the settings. The current trend aimeid to improve the quality of production, discards reduction and the machinary efficiency optimization, has driven many manufacturers to separate the control (which it is yet executed by PLC) from the regulation (removed from PLC to dedicated instrumentation). As a matter of fact, dedicated instrumentation guarantees high speed and accuracy while the separation of functions allows to relieve the very complicated PLC programs. In addition to advantages previously described, rear of board instrumentation allows to safeguard: - the dimensions and layout of the control panel, - the machine operativity, - continuity of the product. Moreover, the LFS-mA may be used as a transmitter, offering at the same time, the analogical (4-20 ma) and digital (RS 485) retransmissions, besides the 2 threshold alarms. The electronic circuitry installed into the rear of board instruments is the same used for panel version and therefore offer the same electrical characteristics, functionality and ease of use which have brought success for the panel version.

UPPER DISPLAY It shows the actual measured value or the selected parameter value. LOWER DISPLAY During the run time mode it shows the operative set point. - In manual mode it shows the output level. - During parameter modifications it shows the abbreviated name of the selected parameter. OUT 1 For LFS - lit when OUT 1 is ON. For LFS ma - flashing with a duty cycle proportional to the power outputs. REM Lit when device is controlled by serial link. OUT 2 Lit when OUT 2 is ON or alarm 1 is in alarm condition. C Lit when the process variable is shown in Celsius degree. OUT 3 Lit when OUT 3 is ON or alarm 2 is in alarm condition. F Lit when the process variable is shown in Fahrenheit degree. MAN Flashing when the instrument is in MANUAL mode. SMRT Lit when the SMART algorithm is active. SP2 Lit when SP2 is operative. DIMENSIONS AND PANEL CUT-OUT STANDARD VERSION REAR-OF-BOARD VERSION 5

LFS / LFS-mA Case: Front protection: Installation: Rear terminal board: Dimensions: Weight: Power supply: (switching mode) Power consumption: Insulation: Common mode rejection ratio: Normal mode rejection ratio: Electromagnetic compatibility and safety requirements: Installation category: D/A conversion: Sampling time: Accuracy: Operative temperature: Storage temperature: Humidity: Protections: self-extinguishing material according to UL 746C standard. - designed and tested for IP 65 (*) and NEMA 4X (*) for indoor locations (when panel gasker is installed). - IP 20 for rear of board version. - (*) Test were performed in accordance with IEC 529, CEI 70-1 and NEMA 250-1991 STD. - panel mounting version by means of tie rods. - Rear of board version on wall or omega DIN rail. with screw terminals, connection diagram and safety rear cover. 48 x 48 mm (according to DIN 43700); depth 122 mm. 250 g. max. (1 lb.). from 100 to 240 V A.C. 50/60 Hz (+10% to -15% of the nominal value) or 24 V AC/DC (±10% of the nominal value). 8 VA. a double or reinforced insulation is guaranteed between the power supply input and all the instrument inputs and outputs. 120 db @ 50/60 Hz. 60 db @ 50/60 Hz. This instrument is marked CE. Therefore, it is conforming to council directive 89/336/EEC (reference harmonized standard EN-50081-2 and EN-50082-2) and to council directives 73/23/EEC and 93/68/EEC (reference harmonized standard EN 61010-1). II. dual slope integration. - for linear inputs = 250 ms. - for TC or RTD inputs = 500 ms. ±0.2% f.s.v. @ 25 C and nominal power supply voltage. from 0 to +50 C. from -20 to +70 C. from 20% to 85% RH not condensing. 1) WATCH DOG for automatic reset. 2) DIP SWITCHES for configuration and calibration parameters. MEASURING INPUTS All the inputs are factory calibrated and selectable by front keyboard. Thermocouples Type: J, K, L, R, S, N, T are keyboard programmable. Engineering unit: C and F keyboard programmable. Burn out: Detection of input opening (wires or sensor) with underrange or overrange selectable. Cold junction: automatic compensation for an ambient temperature between 0 and 50 C. Cold junction compensation error: 0.1 C/ C. Input impedance: > 1 MΩ. Calibration: according to IEC 584-1. STANDARD RANGES TABLE TC type C Range F L 0 / 400,0 L 0 / 900 0 / 1650 J -100,0 / 400,0 J -100 / 1000-150 / 1830 K -100,0 / 400,0 K -100 / 1200-150 / 2190 N -100 / 1400-150 / 2550 R 0 / 1760 0 / 3200 S 0 / 1760 0 / 3200 T -199,9 / 400,0-330 / 750 NOTE: For TC inputs it is possible to select a measuring range, within the standard input range, with a minimum span of 300 C or 600 F. In this way it is possible to increase the sensibility of the control parameters. RTD input RTD type : Pt 100 3 wires connection. Calibration: according to DIN 43760. Line resistance: Max 20 Ω/wire with no appreciable error. Engineering unit: C and F keyboard programmable. Burn out: Detection of sensor opening and of one or more wires opening. Detection of sensor short circuit. STANDARD RANGES TABLE C F -199.9/ 400,0-199.9/ 400,0-200 / 800. -330 / 1470 NOTE: For RTD inputs it is possible to select a measuring range, within the standard input range, with a minimum span of 100 C or 200 F. In this way it is possible to increase the sensibility of the control parameters. 6

ma and V linear inputs ma input (standard): 0-20 ma or 4-20 ma keyboard programmable. Read-out: keyboard programmable from -1999 to 4000. Decimal point : programmable in any position. STANDARD RANGES TABLE Input Impedance 0-20 ma > 5 Ω 4-20 ma > 5 Ω 0-60 mv > 1 MΩ 12-60 mv > 1 MΩ 0-5 V > 200 kω 1-5 V > 200 kω 0-10 V > 400 kω 2-10 V > 400 kω LOGIC INPUTS SET POINTS These instruments are equipped with a logic input to be used to select between main set point and auxiliary set point (SP or SP2) Note: this function excludes the current transformer input (Output 1 load break down alarm). (For LFS-Relay only). Two set points are available: main set point (SP) - auxiliary set point (SP2) Set point transfer Transfer from SP to SP2 and viceversa may be driven by logic input (contact closure). Note: Set point limiters: the transfer may be done by a step transfer or by a ramp with two different programmable rates of rise (ramp up and ramp down). set point low limit and set point high limit are programmable. ALARMS Output action: direct or reverse function programmable. Alarm functions: each alarm can be configured as process alarm, band alarm or deviation alarm. Alarm reset: automatic or manual reset programmable on each alarm. Alarm indications: 2 indicators lit when the respective alarm is ON. Alarm outputs: 2 relay SPST. Contact rated at 2 A, 250 V AC on resistive load. Process alarm Operative mode: minimum or maximum programmable. Threshold: programmable in engineering unit within the whole range. Hysteresis: programmable from 0.1% to 10.0% of the input span. Band alarm Operative mode: Inside or outside programmable. Threshold: programmable from 0 to 500 units. Hysteresis: programmable from 0.1% to 10.0% of the input span. Deviation alarm Operational mode: High or low programmable. Threshold: programmable from -500 to +500 units. Hysteresis: programmable from 0.1% to 10.0% of the input span. OUTPUT "TURN OFF" FUNCTION This function allows to disable the control output. Therefore, it removes power from the controlled load and makes the instrument to operate as an indicator. Therefore, this function allows to maintain the monitoring of the process variable even when the load is OFF. When the control mode is resumed, the instrument will become operative as follows: the integral component of the output signal will be set to zero and the soft start and the alarm masking functions will be enabled. SERIAL INTERFACE Type: isolated RS-485. (optional) Protocol type: MODBUS, JBUS, ERO polling/selecting. Baud rate: keyboard programmable from 600 to 19200 BAUD. Byte format: 7 or 8 bit programmable. Parity: even, odd or none programmable. Stop bit: one. Address: from 1 to 95 for ERO protocol from 1 to 255 for all the other protocols Output voltage levels: according to EIA standard. ACCESSORIES Code RS-232/RS-485 converter with 110/220 V AC power supply CON.VX3.200.000 RS-232/RS-485 converter with 120/240 V AC power supply CON.VX6.200.000 7

LFS relay Push the pushbutton the display shows the load current in Ampere TC or RTD Push pushbuttons the power outputs is turned OFF OIL AIR WATER CONTROL ACTION Algorithm: PID + SMART Type: One (heating) or two (heating and cooling) control outputs. Proportional Band: programmable - from 1.0% to 100.0% of the input span for process with one control output. - from 1.5% to 100% of the input span for process with two control outputs Setting a PB equal to 0 the control action becomes ON/OFF. Hysteresis (for ON/OFF control action): programmable from 0.1% to 10.0 % of the input span. Integral time: programmable from 1 second to 20 minutes or excluded. Derivative time: programmable from 1 second to 10 minutes or excluded. Integral preload: programmable - for one control output, from 0 to 100% of the output range - for two control outputs, from -100% to +100% of the heating/cooling output range. Out 1 cycle time: from 1 second to 200 seconds. AUTO/MANUAL mode: selectable by front pushbutton or logic input. AUTO/MANUAL transfer: bumpless method type Two control outputs (heating/cooling) Relative out 2 gain: keyboard programmable from 0.20 to 1.00 referred to the proportional band. Out 2 cycle time: from 1 second to 200 seconds. Overlap/dead band: keyboard programmable from -20% (dead band) to +50% (overlap) of the proportional band. NOTE: by setting, during configuration procedure, the proper cooling medium: (air, oil or water) the instrument will set automatically the output 2 parameters. CONTROL OUTPUTS This instrument is equipped with 2 independent outputs programmable as: - heating + alarm 1 - heating + cooling In addition to the standard outputs, it can be equipped with an optional output (OUT 3) programmable as: - alarm 2 output - alarm 2 output + OFD alarm output. Type: time proportioning Updading time: - for linear inputs = 250 ms - for TC or RTD inputs = 500 ms. Direct/reverse action: keyboard programmable. Output level indication: the instrument displays separately the output 1 level (heating) and the output 2 level (cooling). Output status indication: two indicators (OUT 1 and OUT 2) are lit when the respective output is in ON condition. Output level limiter: for one control medium: from 0 to 100%. For two control mediums: from -100 to +100%. This function may be operative at instrument start up for a programmable time (To avoid thermal shock and/or preheating the plant). 8

Relay outputs Output cycle time: programmable from 1s to 99 s. Output 1 (heating): SPDT contact with rated current 3 A at 250 V AC on resistive load. Output 2 (cooling): SPST contact with rated current 2 A at 250 V AC on resistive load. Output 3 (optional): SPST contact with rated current 2 A at 250 V AC on resistive load. Logic voltage for SSR driver (output 1 only): logic level 0: Vout < 0.5 V DC. logic level 1: 14 V < Vout < 24 V DC (@ 20 ma) maximum current = 20 ma. OFD FUNCTION (Optional) The instruments equipped with this feature are capable to measure by means of a CT, the out 1 running current. - During the ON period of the output 1, the instrument measures the out 1 running current and it generates an alarm condition when this current is lower than a pre-programmed threshold value (a low current shows a partial or total break down of the load or of the actuator). - During the OFF period of the output 1, the instrument measures the leakage current running in the load and it generates an alarm condition when this current is higher than a pre-programmed threshold value (an high leakage current shows a short circuit of the actuator). Input range: 50 ma AC. Scaling: programmable from 10 A to 100 A (with 1 A step). Resolution: - for full scale up to 20 A: 0.1 A. - for full scale from 21 A to 100 A: 1 A. Active period: - for relay output: NO or NC programmable - for SSR output: logic level 1 or 0 programmable. Minimum active period to perform the measurement: 400 ms. Note: this function excludes the logic input (external set point selection). HOW TO ORDER Optional ACCESSORIES MODEL LFS = Dual 4 digit display INPUT 9 = TC, RTD, 20 ma, 60 mv, 5 V and 10 V (*) CONTROL ACTION 3 = PID + SMART MAIN OUTPUT 1 = Relay 6 = SSR OUTPUT 2 1 = Relay (*) it is possible to select, by jumpers, the input full scale among 20 ma, 60 mv, 5 V or 10 V; all ranges are factory calibrated. CURRENT TRANSFORMER MODEL CTR = Current transformer CTR PRIMARY CURRENT 1 = 10 A 2 = 25 A 4 = 50 A 5 = 100 A This accessory is applicable only to models with OFD alarm function. OPTIONS 0 = No options 1 = Alarm 2 2 = Alarm 2 + OFD 2 = (or logic input) 3 = Alarm 2 + optoisolated RS 485 4 = Alarm 2 + optoisolated RS 485 + OFD (or logic input) POWER SUPPLY 3 = 100 240 V A.C. 5 = 24 V A.C. or D.C. REAR TERMINAL BLOCK VERSION 0 = Standard R = Rear-of-board STANDARD VERSION REAR-OF-BOARD VERSION LFS 9 3 1 0 0 9

LFS ma 4-20 ma LINEAR OUTPUT PROGRAMMABLE 2 set points selectable by contacts analog retransmission of the measured value or control output or analog retransmission of the operative set point CONTROL ACTION Algorithm: PID + SMART Type: One (heating) or two (heating and cooling) control outputs. Proportional Band: programmable from 1.0% to 200.0% of the input span. Setting a PB equal to 0 the control action becomes ON/OFF. Hysteresis (for ON/OFF control action): programmable from 0.1% to 10.0 % of the input span. Integral time: programmable from 1 second to 20 minutes or excluded. Derivative time: programmable from 1 second to 10 minutes or excluded. Integral preload: programmable - for one control output, from 0 to 100% of the output range - for two control outputs, from -100% to +100% of the heating/cooling output range. Out 1 cycle time: from 1 second to 200 seconds. AUTO/MANUAL mode: selectable by front push-button or logic input. AUTO/MANUAL transfer: bumpless method type Two control outputs (heating/cooling) Relative out 2 gain: keyboard programmable from 0.20 to 1.00 referred to the proportional band. Out 2 cycle time: from 1 second to 200 seconds. Overlap/dead band: keyboard programmable from -20% (dead band) to +50% (overlap) of the proportional band. NOTE: by setting, during configuration procedure, the proper cooling medium: (air, oil or water) the instrument will set automatically the output 2 parameters. CONTROL OUTPUTS 10 This instrument is equipped with 3 independent outputs programmable as follows: OUT 1 OUT 2 OUT 3 linear (ma) relay relay Heating AL 1 AL 2 Heating Cooling AL 2 Heating AL 1 Cooling Cooling AL 1 AL 2 Cooling Heating AL 2 Cooling AL 1 Heating Retransm. Heating AL 2 Retransm. AL 1 Heating Retransm. Cooling AL 2 Retransm. AL 1 Cooling Retransm. Heating Cooling Retransm. Cooling Heating Retransm. AL 1 AL 2

Updading time: Action: Output level indication: - for linear inputs = 250 ms - for TC or RTD inputs = 500 ms. direct/reverse programmable by front keyboard. the instrument displays separately the output 1 level (heating) and the output 2 level (cooling). Output status indication: the OUT 1 LED will flash with a duty cycle proportional tp the output 1 power. Two indicators (OUT 2 and/or OUT 3) are lit when the respective output is in ON cindition. Output level limiter: for one control medium: from 0 to 100%. For two control mediums: from -100 to +100%. This function may be operative at instrument start up for a programmable time (To avoid thermal shock and/or preheating the plant). OUTPUT 1 Type: optoisolated 0-20 ma or 4-20 ma programmable. Function: programmable as: - control output (heating or cooling) - retransm. of the measured value - retransm. of the operative set point. Scaling: programmable from -1999 to 4000. Maximum load: 500 Ω. Resolution: - 0.1% when used a control output - 0.05% when used as analog retransmission. Digital filter: it is possible to enable digital filter, on the output retransmission, with the same time constant for the read-out. Output level indication (as control output only): from 00.0 to 100%. Output status indication: the indicator OUT 1 flashes with a duty cycle proportional to the output level. OUTPUT 2 Type: relay SPST contact (NO or NC selectable by jumper). Function: programmable as: - control output (heating or cooling) - alarm 1 output. Output cycle time (when used as control output): programmable from 1 s to 99 s. OUTPUT 3 Type: relay with SPST contact with rated current 2 A at 250 V AC on resistive load. Function: programmable as: - control output (heating or cooling) - alarm 2 output. Output cycle time (when used as control output): programmable from 1 s to 99 s. HOW TO ORDER MODEL LFS = Dual 4 digit display INPUT 9 = TC, RTD, 20 ma, 60 mv, 5 V and 10 V CONTROL ACTION 3 = PID or SMART OUTPUT 1 7 = ma linear programmable as heating, cooling or analog retransmission OUTPUT 2 1 = Relay OPTIONS 1 = Alarm 2 3 = Alarm 2 + optoisolated RS 485 POWER SUPPLY 3 = 100-240 V A.C. 5 = 24 V A.C. or D.C. REAR TERMINAL BLOCK STANDARD VERSION REAR-OF-BOARD VERSION VERSION 0 = Standard R = Rear-of-board LFS 9 3 7 1 0 0 11