STANDARD CONSTRUCTION JOINT DETAILS

Similar documents
Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Concrete Waterproofing Systems

The AQUAFIN Approach to Concrete Repair

SECTION STORM DRAINAGE SYSTEM

Section SEWER PIPE INSTALLATION AND TESTING

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Wastewater Capital Projects Management Standard Construction Specification

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

Chapter. Restoration of Damaged Structures

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

Concrete Waterproofing Systems. Integral Protection.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry

Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

The minimum reinforcement for the stem wall is the placement of:

School Construction Authority Architecture & Engineering

Complete Waterproofing Protection from Rooftop to Basement. Crack Injection, Joint Waterproofing, Waterproofing Membranes

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Best Basement Water Management Practices

Free-Form Concrete Pool

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Concrete Waterproofing by Crystallization. General Construction Foundations

SECTION ABANDONMENT OF SEWER MAINS

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

T R A N S F E R A B L E F U L LY

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

State of Connecticut Department of Public Health RADON PROGRAM

constructive solutions Fosroc total waterproofing protection of below-ground structures

Seattle Public Schools Building Excellence IV Projects Under Construction

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

LAYING BLOCK AND BRICK

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

How To Install An Overhead Sewer

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

SikaProof A Technology

WATERPROOFING SikaProof -A TECHNOLOGY

SECTION STORM DRAIN SYSTEM

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

Hunter College school of Social Work Thesis Proposal

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

SANITARY SEWER SPECIFICATIONS

WATERPROOFING PRODUCTS

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

Specification Underground Services - Subdivisions. Issue 12

Excerpts from the Canadian National Building Code (NBC)

COMMONLY USED RESIDENTIAL BUILDING CODES

Waterproofing construction Joints

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

USER GUIDE Easier, Safer, Betta! WATERPROOFING

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

C O N C R E T E WAT E R P R O O F I N G B Y C RY S TA L L I Z AT I O N

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

WATERPROOFING BASEMENTS

Comment Form on Proposed Gut Rehabilitation Alternatives

Chapter 2 Basis of design and materials

Rehabilitation of an Aging Concrete Reservoir Adit Tower

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

Protect Your Home From Flooding. A guide for Lethbridge Residents

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

Reference: BRM A0 July 18 th, Cursory Visual Review of Various Below Grade Spaces and Exposed Foundation Walls

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Swimming Pool Tiling Specialists

R E S I D E N T I A L H O U S I N G

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION NONREINFORCED CONCRETE SEWER PIPE

If stepping is required, step at 180mm as seen in this picture.

WATERPROOFING OF WET ROOMS

INSPECTION FINDINGS. for. Paragon Condominiums 2102 W 31 st Avenue Denver, Colorado. Inspection Date: August 8, Perfonned By: Drew Schneider

Requirements for Building Application Submission

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Water Damage & Repair

What Causes Foundation Leaking?

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

SECTION ABANDONMENT OF WATER MAINS. A. Conform to requirements of Section Submittals.

Stormwater/Wetland Pond Construction Inspection Checklist

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

General Construction Foundations. Concrete Waterproofing by Crystallization

INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

Basement Waterproofing in Existing Buildings

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

Think Of Us First! When It s Time to Distribute Your Plans

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Transcription:

STANDARD CONSTRUCTION JOINT DETAILS Not subject to hydrostatic pressure Reinforcing continuous through joint. Nominal x 4 (50 mm x 00 mm) or x 6 (50 mm x 50 mm) key centered in joint. Subject to hydrostatic pressure Reinforcing continuous through joint. Nominal x 4 (50 mm x 00 mm) or x 6 (50 mm x 50 mm) key centered in joint. Walls & Slabs Step Step Joint Waterproofing: Clean joint thoroughly. Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Sealing Strip: Clean pre-formed groove thoroughly. Apply Xypex Concentrate slurry to groove at the rate of.5 lb./sq. yd. (0.8 kg/m ). Fill groove with Xypex Concentrate Dry-Pac and pack tightly. Pre-formed groove may be offset to either side of joint. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

STANDARD CONSTRUCTION JOINT DETAILS Not subject to hydrostatic pressure Nominal x 4 (50 mm x 00 mm) or x 6 (50 mm x 50 mm) key centered in joint. Reinforcing continuous through joint. Subject to hydrostatic pressure Reinforcing continuous through joint. Nominal x 4 (50 mm x 00 mm) or x 6 (50 mm x 50 mm) key centered in joint. Walls / Slab Interface Step Step Joint Waterproofing: Clean joint thoroughly. Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Sealing Strip: Clean pre-formed groove thoroughly. Apply Xypex Concentrate slurry to groove at the rate of.5 lb./sq. yd. (0.8 kg/m ). Fill groove with Xypex Concentrate Dry-Pac and pack tightly. Pre-formed groove may be offset to either side of joint. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

CONCRETE WALL AND SLAB BELOW GRADE Step Step Step Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ) then fill slot to surface with Xypex Concentrate in Dry-Pac form. Apply one coat of Xypex Concentrate to wall and slab surfaces as indicated at the rate of.5 lb./sq. yd. (0.8 kg/m ). Where poor drainage conditions exist or high hydrostatic pressures are anticipated, also apply a coat of Xypex Modified to wall and slab surfaces at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

FOUNDATION WALL INSIDE APPLICATION Step Step Step Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Apply one slurry coat of Xypex Concentrate to wall and slab surfaces as indicated at the rate of.5 lb./sq. yd. (0.8 kg/m ). Where poor drainage conditions exist or high hydrostatic pressures are anticipated, also apply a coat of Xypex Modified to wall and slab surfaces at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 4

RETAINING WALL Step Step Step Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Apply one coat of Xypex Concentrate to wall face and over sealing strip at the rate of.5 lb./sq. yd. (0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 5

C O N C R E T E B L O C K WA L L B E L O W G R A D E E X T E R I O R A P P L I C AT I O N MEGAMIX I Step Step Step Prior to placement of the concrete wall and slab, apply one slurry coat of Xypex Concentrate to joint surfaces at the rate of lb./sq. yd. ( kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb/sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. To exterior wall surface and footing apply one coat of Xypex Concentrate at the rate of.0 lb./sq. yd. (.0 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Megamix I at the rate of.5 lb./sq. yd. (5.5 kg/m ). Note: Because of the variances in the quality of concrete block (e.g. cement, content, porosity, etc.), please consult your Xypex technical representative. Schematic diagram shows Xypex coatings application only and does not depict the standard requirements for waterstops, expansion joint sealants, or pointing repairs that may be required. Refer to Standard Specifications for further information. 6

CONCRETE BLOCK WALL BELOW GRADE INSIDE APPLICATION MEGAMIX I Step Step Step Prior to placement of the concrete wall and slab, apply one slurry coat of Xypex Concentrate to joint surfaces at the rate of lb./sq. yd. ( kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb/sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. To inside wall surface apply one coat of Xypex Concentrate at the rate of.0 lb./sq. yd. (.0 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Megamix I at the rate of.5 lb./sq. yd. (5.5 kg/m ). Note: Because of the variances in the quality of concrete block (e.g. cement, content, porosity, etc.), please consult your Xypex technical representative. Schematic diagram shows Xypex coatings application only and does not depict the standard requirements for waterstops, expansion joint sealants, or pointing repairs that may be required. Refer to Standard Specifications for further information. 7

CONCRETE BLOCK WALL ABOVE GRADE EXTERIOR APPLICATION Step Apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ). Coating should extend to ground level. Where poor quality block is encountered, a second coat of Xypex Concentrate should be applied at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Wall sections should be defined before application and each of these sections should be completed during the same day to obtain maximum uniformity in appearance. Because of the variances in the quality of concrete block (e.g. cement content, porosity, etc.), please consult your Xypex technical representative. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the alternative use of Xypex Dry Shake (DS-Series), Xypex Additive (Admix C-Series) or Xypex Megamix I, where 8

PARKING DECK Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To slab, apply one coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 9

ROOF / PLAZA DECK Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To slab and adjacent curb wall apply one coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Use appropriate material for protection against sudden thermal changes. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 0

ELEVATOR PIT / SUMP PIT Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step Apply one slurry coat of Xypex Concentrate to walls and floor slab at a rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). For hydraulic elevators, please contact your Xypex representative for detail drawings. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

PLANTER Step Step Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ) to all interior wall and floor surfaces. After slurry coat has set but while it is still green, apply a cove strip of Xypex Modified mortar over interior slab/wall construction joint. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

TUNNEL Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To all ceiling, wall, and floor surfaces, apply one slurry coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

SWIMMING POOL Step Step Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. To pool deck and all interior wall and floor surfaces, apply one slurry coat of Xypex Concentrate at a rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set but while it is still green, apply a coat of Xypex Modified at a rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). In new construction, Xypex Concentrate DS- or Xypex Admix is recommended for pool deck and floor surfaces. Please refer to product data sheets. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 4

SEWAGE PLANT CLARIFIER TANK Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To all ceiling, wall, and floor surfaces, apply one slurry coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set, but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 5

SEWAGE PLANT DIGESTER TANK Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To all wall and slab surfaces, apply one slurry coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set, but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 6

RESERVOIR / WET WELL Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To interior walls, slab and exterior of roof area, apply one slurry coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set, but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 7

UNDERGROUND VAULT / DRY WELL Step Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of.0 lb./sq. yd. (.0 kg/m ). Step In sealing strip, apply one coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill slot to surface with Xypex Concentrate in Dry-Pac form. Step To interior floor areas and exterior walls and roof, apply one slurry coat of Xypex Concentrate at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After the Concentrate has set, but while it is still green, apply a coat of Xypex Modified at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 8

PRECAST CONCRETE MANHOLE 4 4 PATCH N PLUG Step Step Step Step 4 Place block in joints to allow 0.5-0.75 in. ( - 9 mm) gap between precast sections. Fill exterior gap with Xypex Patch n Plug grout. Apply one slurry coat of Xypex Concentrate to the interior gap at the rate of.5 lb./sq. yd. (0.8 kg/m ), then fill gap to surface with Xypex Concentrate in Dry-Pac form. Apply one slurry coat of Xypex Concentrate to interior of bottom ring, floor and exterior walls at the rate of.5 -.5 lb./sq. yd. (0.65-0.8 kg/m ). After placement of concrete trough, apply one slurry coat of Xypex Concentrate at the rate of.5 lb./sq. yd. (0.8 kg/m ) to its surface. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 9

STANDARD METAL PIPE DETAIL Step Apply Xypex Concentrate slurry to the groove at the rate of.5 lb./sq. yd. (0.8 kg/m ). Step Fill groove to surface with Xypex Concentrate in Dry-Pac form and pack tightly. Brush Dry-Pac liberally with water and apply a Xypex Concentrate slurry over the Dry-Pac at the rate of.5 lb./sq. yd. (0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the 0

FERRO-CEMENT BOAT / CAISSON / FLOATING DOCK Step Step Apply one slurry coat of Xypex Concentrate to hull exterior, gunwhales, and all exterior decks at the rate of.5 lb./sq. yd. (0.8 kg/m ). Apply one coat of Xypex Modified to interior surface of hull at the rate of.5 lb./sq. yd. (0.8 kg/m ). In the case of sealed, hollow-core caissons, step is eliminated and the Concentrate slurry coat in step should extend over entire exterior of unit. Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the

BRIDGE 4 Step Step Step Step 4 Apply one slurry coat of Xypex Concentrate to structural slab at the rate of.5 lb./sq. yd. (0.8 kg/m ). Apply one slurry coat of Xypex Concentrate to joint surface between parapet wall and bridge deck at the rate of.0 lb./sq. yd. (.0 kg/m ). Xypex must be applied no more than 4 hours prior to concrete placement. Apply a cove strip of Xypex Modified mortar over slab/wall construction joint so that the cove extends in. (5 mm) up the wall and in. (5 mm) out on to the deck surface. Apply one slurry coat of Xypex Concentrate to wall surfaces at the rate of.5 lb./sq. yd. (0.8 kg/m ). Note : Schematic diagram shows Xypex application details only and does not depict standard Note : Schematic drawing shows Xypex Coating application. Specifier may consider the