Hydrostatic Level Measurement Waterpilot FMX 165

Similar documents
Features. Picture. Specifications

Liquid Level Limit Switch liquiphant T FTL 20

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ATL Fuel Level Sender Probes

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PART 1 - INTRODUCTION...

Conductive Level Switch FK 2 Technical Data:

Micro Motion Model D and DL Coriolis Flow and Density Meters

Duct Humidity Transmitter

Data Sheet PS1B Pressure Switch

Electromagnetic Flow Meter

Temperature Switch Thermophant T TTR 31, TTR 35

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Micro Motion 3098 Gas Specific Gravity Meter

Relative pressure transmitter type 520

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

LC/LCD ranges level controllers

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

2.12. page Products for Explosion hazardous Environment

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital inductive conductivity transmitter

Electronic Pressure Switch EDS 3000

CAPACITIVE LEVEL METERS CLM 36

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Technical Information RIA14

Proximity Transmitters and Seismic Vibration Transmitters

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

FAQ s on Siemens Magmeters

Models SFP33 & SFP32 Pressure Transmitters

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

2.24. Pump Controller 704. Data Sheet

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

SITRANS F flowmeters SITRANS F M

Electronic Pressure Switch EDS 300

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Electronic Pressure Monitoring New Products

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

PRODUCT PROFILE FEATURES

Inductive sensor NI10-M18-Y1X-H1141

Redundancy Module QUINT-DIODE/40

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Pressure transmitter For general industrial applications Model A-10

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Relative and absolute pressure switch type 529

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Technical Data. Dimensions

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Subminiature Load Cell Model 8417

Mass Flow Meters & Controllers

Datalogger DL/N 70 Version:

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

S300 Series Dust Monitors

3DLevelScanner II TECHNICAL DATA SHEET

Plastic tube flowmeters Series PT/PS

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

How To Use A Flowmeter

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Instruction Manual. T3111 T3111L T3111P T3111Ex

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic Flow Switches

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Typical Aluminum GFM Mass Flow Meter

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Solenoid Valve Island Type 3965

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Series 510 Submersible Level Transmitters

Sanitary Type Electronic Flow Switches

Operating Instructions for Plastic Flow Meter. Model: KSK

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

TEIP11 I/P signal converter for standard signals. Measurement made easy

OPTIMASS 6000 Technical Datasheet

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Rosemount 333 HART Tri-Loop

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

ALARMLINE ANALOGUE Linear Heat Detection System

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

The Do s and Don ts of Pressure Transducers

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Transcription:

Technical Information TI 90F/4/ae Operating instructions 017509-1000 Hydrostatic Level Measurement Waterpilot FMX 165 Low-cost and reliable cable probe with ceramic measuring cell Standard instrument for level measurement in wells and sewage treatment plants Application Areas The Waterpilot FMX 165 is a hydrostatic pressure sensor for level measurement of water and wastewater. The FMX 165 has nine permanently calibrated measuring ranges from 1.5 psi to 300 psi (0.1 bar to 0 bar) to ensure use in all standard applications including deep wells, water towers, and sewage treatment plants. Features and Benefits With its high electrical and mechanical stability, the Waterpilot FMX 165 fulfills all plant construction standards. Ceramic measuring cell - extremely resistant to overload, alternating loads and aggressive media Support cable with hard-wearing conical seal of the probe tube and climatic protection in the pressure compensation tube Permanent hermetically sealed submersible cable probe Potted electronics with 4 to 0 ma output signal and integrated overvoltage protection The Power of Know How

RIA 450 FMX 165 Measuring system Complete measuring system The complete measuring system consists of the FMX 165 Waterpilot and a 1 to 30 VDC power supply. Transmitters: 1 RIA 450 contactor for the power supply and or 3 point control. 3 Display and documentation of measurement data with printers and registration units from. Junction box: Junction box with terminal strip, including three terminals and GORE-TEX filter, NEMA 4X. 1 3 FMX 165 Deep well measurement % + E Power RIA 450 Process Indicator Power Chart Recorder Deep well measurements with the FMX 165 Waterpilot The FMX 165 can be connected to a junction box, especially if the probe cable is terminated outdoors. The junction box can be ordered as part of the system or as an accessory. Junction box

Operating Principle Ceramic measuring cell The ceramic measuring cell is oil-free, i.e. the process pressure acts directly on the ceramic diaphragm of the FMX 165 and causes it to move by a maximum of 0.001 (0.05 mm). A pressure dependent change in capacitance is measured by the electrodes in the ceramic substrate and the diaphragm. Ceramic cell advantages: Completely safe in vacuum Guaranteed overload resistance up to 40 times nominal pressure Extremely high chemical resistance Installation Mounting Point Support cable The cable probe should be installed in an area free from flow and turbulence. A guide tube should be used (internal diameter approximately.56 (65 mm), in order to prevent the probe from swinging from side to side in adverse conditions. Lower the cable probe slowly into the process liquid The probe should not touch the shaft or walls of the tube; a plastic guide tube is recommended for very turbulent liquids. The connecting box must be mounted outside the shaft with the connection cable leading to the control room. Slip-resistant cable with steel wire braiding and PE insulation Maximum length without additional strain relief, 656 feet (00 m) Minimum bending radius, 7.87 (00 mm) Mechanical construction Pressure compensation tube 0.87" () 0.43" (11) Support cable 6.89" (175).05" (5) 7.48" (190) 1.18" (30) 1.89" (48) Max..05" (5) Mounting clamp 1.65" (4) Probe housing 3

Electrical connection 1 to 30 VDC GND 4 to 0 ma R L Red Black Electrical connection of FMX 165 Shielded instrument cable is recommended Terminal housing with Gore-Tex filter FMX 165 - x G x xx x FMS 165 - x K x xx x Terminal housing including three terminals and filter Terminal housing including three terminals and filter plus 316L mounting clamp.16" (55).36" ± 0." (60 ±0.5) 4.7" (10) 0.1" (3) Dummy plug M 0x1.5 4.6" (108.) 0.18" ( 4.5) 1.98" (50.) ~1.18" (~30) GORE-TEX filter Clamp for 0.0001 to 0.004 in (0.08 to.5 mm ) M 0x1.5 Junction box 4

Input Measured variable Measuring range Level by measuring the hydrostatic pressure of a column of liquid Permanently set from 1.5 to 90 psi (0.1 bar to 0 bar) refer to Ordering Information for individual ranges Output Output signal Evaluating units Load 4 to 0 ma Connections to transmitter power units, relay contactors or recorder units Maximum 900 Ω Accuracy Reference conditions Conformity error Long-term stability Thermal variation Temperature coefficient According to DIN 16 086 Including repeatability and hysteresis, 0.% full scale (according to limit point method) 0.1% full scale per year Zero signal and output span ± 1% of span Zero signal and output span 0.15%/10 K of span Operating conditions, environment Operating temperature range Storage temperature Ingress protection Electromagnetic compatibility Process temperature range Process pressure range 3 to 158 F (0 to 70 C) -4 to 176 F (-0 to 80 C) Connection box, NEMA 3 (IP 54) Interference emission to EN 50081-1 Interference immunity to EN 5008- and NAMUR industrial standard, with 10 V/m Endress+ Hauser recommendes the use of shielded instrument cable. 3 to 158 F (0 to 70 C) Refer to measuring range, page 6 Mechanical construction Probe housing Support cable Seal Process diaphragm Mounting accessory Weight Measuring cell 316Ti SS Slip-proof cable with steel braiding, insulated with polyethylene (PE), minimum bending radius 7.87 (00 mm) maximum length 656 feet (00 m) without additional strain relief Viton Al O 3 aluminum oxide ceramic Steel mounting clamp, with galvanized pressed metal jaws Probe without supporting cable, 1.1 lb (0.5 kg) Mounting clamp with connection box, 1.1 lb (0.5 kg) Support cable, 0. lb per 3 foot (0.1 kg/m) Fill fluid - Oil-free, dry sensor Power supply Certificates and approvals Supply voltage Explosion protection 1 to 30 VDC PTB: EEx ia IIC 5

FMX 165 load curve R tot/ Ω 900 0 1 30 U / V Measuring range psi (bar) ft H O (meters H O) Max. overload 0 to 1.5 (0 to 0.1) 0 to 3 (0 to 1) 58 psi (4 bar) 0 to 3 (0 to 0.) 0 to 6 (0 to ) 87 psi (6 bar) 0 to 6 (0 to 0.4) 0 to 15 (0 to 4) 87 psi (6 bar) 0 to 9 (0 to 0.6) 0 to 0 (0 to 6) 145 psi (10 bar) 0 to 14.5 (0 to 1) 0 to 30 (0 to 10) 145 psi (10 bar) 0 to 9 (0 to ) 0 to 60 (0 to 0) 61 psi (18 bar) 0 to 59 (0 to 4) 0 to 150 (0 to 40) 36 psi (0 bar) 0 to 145 (0 to 10) 0 to 300 (0 to 100) 580 psi (40 bar) 0 to 90 (0 to 0) 0 to 600 (0 to 00) 580 psi (40 bar) 6

Ordering information FMX 165 Waterpilot FMX 165-1 3 4 5 Probe length 1 Certificates A Standard G ATEX II G EEx ia IIC T6 C ATEX II 3G EEx na II T6 Mechanical connection D Extension cable only E Mounting clamp, 316 L SS G Terminal box, NEMA 4X, with filter K Mounting clamp, 316 L SS, with terminal box, NEMA 4X with filter Y Other 3 Material of probe housing A 316Ti SS 4 Measuring cell and ranges psi (bar) 01 0 to 1.5 (0 to 0.1) 0 0 to 3 (0 to 0.) 04 0 to 6 (0 to 0.4) 06 0 to 10 (0 to 0.6) 10 0 to 15 (0 to 1) 0 0 to 30 (0 to ) 40 0 to 60 (0 to 4) 11 0 to 145 (0 to 10) 0 to 300 (0 to 0) 70 Adjust 0 to upper range full scale value in psi (bar) ft H O (mh O) A0 0 to 3 (0 to 1) A1 0 to 6 (0 to ) A 0 to 15 (0 to 4) A3 0 to 0 (0 to 6) A4 0 to 30 (0 to 10) A5 0 to 60 (0 to 0) A6 0 to 150 (0 to 40) A7 0 to 300 (0 to 100) A8 0 to 600 (0 to 00) AA Adjust 0 to upper range full scale value in fth O (mh O) 5 Probe cable length A Length in meters, PE cable, can be shortened (state length in meters) B 10 m extension cable, PE, can be shortened C 0 m extension cable, PE, can be shortened E 30 ft extension cable, PE, can be shortened F 60 ft extension cable, PE, can be shortened G Length in feet, PE cable, can be shortened (state length in feet) K 10 m extension cable, FEP, can be shortened L 0 m extension cable, FEP, can be shortened I Length in meters, FEP cable, can be shortened (state length in meters) M 30 ft extension cable, FEP, can be shortened N 60 ft extension cable, FEP, can be shortened P Length in feet, FEP cable, can be shortened (state length in feet) Probe length as required, measured from tip of probe. 7

For application and selection assistance, call 888-ENDRESS For total support of your installed base, 4 hours a day, call 800-64-8737 Visit us on our web site, www.us.endress.com United States, Inc. 350 Endress Place Greenwood, IN 46143 Phone: (317) 535-7138 888-ENDRESS FAX: (317) 535-8498 Canada Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Phone: (905) 681-99 800-668-3199 FAX: (905) 681-9444 Mexico Paseo del Pedregal No. 610 Col. Jardines del Pedregal 01900, Mexico D.F. Mexico Phone: (55) 568-405 FAX: (55) 568-7459 The Power of Know How TI 90F/4/ae/06.04 004, Inc.