Operating Instructions / Manual

Similar documents
Certificates. ET-xx8 MT-xx8. SERIES 400 Panel PC SERIES 500 Thin Clients. R. STAHL HMI Systems GmbH Im Gewerbegebiet Pesch Köln

HARTING econ 3000 Introduction and features

HARTING mcon 1000 Introduction and features

HARTING mcon 3000 Introduction and features

Series 8146/5-V37 and Series 8150/5-V37

Terminal Boxes Series 8146

Inductive sensor NI10-M18-Y1X-H1141

Plug and Socket Devices SolConeX 16 A Series 8570

MCR1900 Media Converter 19-Slot Chassis

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Plug and Socket Devices CES 63 A Series 8579

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

10/100/1000 Base-T to Gigabit Fiber Media Converter

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Technical Data. Dimensions

Control and Distribution Boxes made of Stainless Steel Series 8150

My first Hirschmann: The SPIDER family of switches.

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Perle 10/100 Ethernet Media Converters

Operating Instructions

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

HARTING econ 4000 Introduction and features

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Linear Luminaire with LED Series EXLUX 6402/2

Perle Gigabit Fiber to Fiber Media Converters

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Cable Plug acc. to DIN EN , Form A

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Ixia Net Optics 10G Regen Tap

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

1756 ControlLogix Chassis Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Redundancy Module QUINT-DIODE/40

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Perle Fast Fiber to Fiber. Media Converters

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

CompactRIO crio-9052

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PoE+ Extender Switch User's Manual. Rev W

IMC-101 Series Hardware Installation Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

2.12. page Products for Explosion hazardous Environment

Operating Instructions

Gigabit Switching Ethernet Media Converters - Product User Guide

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

TX OPEN RS232/485 module

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Power Supplies 3. SDN-P DIN Rail Series

QuickSpecs. Models. ProCurve Mini-GBICs Overview. ProCurve Gigabit-LX-LC Mini-GBIC. ProCurve Gigabit-LH-LC Mini-GBIC

DeltaV Control Network Hardware

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Perle Protocol Transparent Media Converter Modules

Explosion proof enclosures

2G-1.1.0, 200M-2.0.3, 200M-1.0.1

IFS SP-PoE Splitter User Manual

User Guide. HDMI Active Cable Extender. DVI-7370c

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

HP ProCurve High-Speed Transceivers Installation Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Terminal Box. Specifications TNCN

Microcor Wireless Transmitter (MWT)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Solenoid Valve Island Type 3965

TX2123 RS485 TO ETHERNET ADAPTOR

FCC COMPLIANCE STATEMENT

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

Operating Instructions

Technical Information RIA14

G-TAP A Series // Data Sheet

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Flameproof Audible Signal 115 db (A) Series YA90

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

ProCurve Switch 1400 Series

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Transcription:

Operating Instructions / Manual SK-DRAG-GBIC-SX SK-EL1000-2GU-3TX-4SX-opis SK-EL1000-2GU-3TX-4LX-opis R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Document Version: 01.00.01 Issue date: 10.02.2016

Publisher Publisher Publisher and copyright holder: R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Registered place of business: Cologne Court of registration: District court Cologne, HRB 30512 VAT number: DE 812 454 820 Phone: (switchboard) +49 (0) 221 76 806-1000 (hotline) - 5000 Fax: - 4100 E-mail: (switchboard) office@stahl-hmi.de (hotline) support@stahl-hmi.de All rights reserved. This document may not be reproduced in whole or in part except with the written consent of the publisher. Subject to alterations. Any warranty claims are limited to the right to demand amendments. Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation. We reserve the right to change our products and their specifications at any time, provided it is in the interest of technical progress.the information in the current manual (online or on CD / DVD) or in the operating instructions included with the equipment applies. Trademarks The terms and names used in this document are registered trademarks and/or products of the companies in question. Copyright 2016 by R. STAHL HMI Systems GmbH. Subject to alterations Page 2 of 12 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016

Table of contents Table of contents Description Page Publisher 2 Table of contents 3 1 Preface 4 2 Product details 4 3 Type allocation 4 3.1 Type marking 4 4 Technical data 5 5 Conformity to standards 6 6 Marking 6 7 Permitted maximum values 6 7.1 Inherently safe optical interface 6 8 Installation safety information 7 9 Connection diagrams 8 9.1 SK-DRAG-GBIC-SX 8 9.2 SK-EL1000-2GU-3TX-4SX-opis 8 10 Declaration of EC conformity 9 11 Release notes 11 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016 Page 3 of 12

Preface 1 Preface These Operating Instructions / manual contain information in the Gigabit Ethernet Switches and how they are commissioned. 2 Product details The Ethernet Switches dealt with in this documentation are "unmanaged" Ethernet Switches with a gigabit connection and a different number of connections. They can be mounted on a DIN rail and have various LEDs. These Ethernet Switches are used when series ET-/MT-4x7 or ET-/MT-5x7 HMI units are connected to a communication system via the FO connection. 3 Type allocation Since the beginning of 2013, the T-series devices have been allocated new type names according to the following pattern: To avoid having to re-write certifications, the names in the certificates remain the same, but the devices receive new names. In the interest of a clear link between device type and certificate, both device names are listed on the type plate from 01.04.2013 onwards. 3.1 Type marking Old (certificate) T-Ex-KVM*-MM* T-Ex-KVM*-MM* T-Ex-KVM*-SM* New SK-DRAG-GBIC-SX SK-EL1000-2GU-3TX-4SX-opis SK-EL1000-2GU-3TX-4LX-opis * = alphanumeric or symbolic characters without relevance to explosion protection. NOTICE The Ethernet Switches described in this document are associated equipment and as such covered by the certificates of the ET-xx7 (T-Ex) main devices. Page 4 of 12 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016

Technical data 4 Technical data Product version / definition SK-DRAG-GBIC-SX SK-EL1000-2GU-3TX-4SXopis SK-EL1000-2GU-3TX-4LXopis Picture Function / Equipment Version Single Port Fiber Switch Quad Port Fibre Switch Quad Port Fibre Switch Ethernet interface Copper (TX) 10/100/1000Base-TX Plug type RJ45 Quantity 4 3 3 Optical fibre 1000Base-SX 1000Base-LX Plug type LC Quantity 1 4 4 Cable type Multi-mode Multi-mode Single mode Core diameter 50 / 62.5 µm 9 µm Outer diameter 125 µm Type of protection Intrinsically safe (Ex op is) Wavelength 850 nm 1310 nm Radiant power 0.22 mw Max. radiant power: 35 mw Data cable lengths Copper (TX) up to 100 m (330 ft) via CAT5 cable Optical fibre up to 500 m (1,640 ft) up to 10,000 m (32,808 ft) LEDs Power (green) Error (red) Link / activity (green) Speed (green) Power supply Redundant Connections via screw terminals Voltage supply 12-48 VDC 12-65 VDC Power 5.5 W 8 W Ambient conditions Operating temperature range -10 C to +60 C -30 C to +55 C (14 F to 140 F) (-22 F to 131 F) Storage temperature range -40 C to +85 C (-40 F to 185 F) Relative humidity 5 to 95 %, non-condensing Enclosure Metal Stainless steel, powder-coated Dimensions (W x H x D) [mm] (inch) 30 x 140 x 95 70 x 130 x 145 (1.18 x 5.51 x 3.74) (2.76 x 5.12 x 5.71) Weight 850 g (1.87 lbs) R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016 Page 5 of 12

Conformity to standards 5 Conformity to standards The Ethernet Switches comply with the following standards and directive: 6 Marking Manufacturer Type code Standard Directive 94/9/EC Classification 2. Supplement EN 60079-0 : 2009 General requirements IEC 60079-0 : 2007 EN 60079-28 : 2004 Optical radiation IEC 60079-28 : 2006 Electromagnetic compatibility Directive 2004/108/EC acc. to EN 61000 CE classification: c 0158 R. STAHL HMI Systems GmbH SK-DRAG-GBIC-SX SK-EL1000-2GU-3TX-4SX-opis SK-EL1000-2GU-3TX-4LX-opis Testing authority and certificate number: BVS 11 ATEX E 102 X Ex classification: ATEX guideline 94/9/EC IECEx IECEx TUR 11.0075X e 7 Permitted maximum values 7.1 Inherently safe optical interface Optical fibre Ethernet Multi mode Wavelength Radiant power max. radiant power: 850 nm 0.22 mw 35 mw II (1) G [Ex op is Ga] IIC II (1) D [Ex op is Da] IIIB [Ex op is Ga] IIC [Ex op is Da] IIIB Single mode Wavelength Radiant power max. radiant power: 1310 nm 0.22 mw 35 mw Page 6 of 12 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016

Installation safety information 8 Installation safety information When electrical equipment and installations are being operated, parts inevitably will be under dangerous levels of high voltage. Consequently, only electric experts or trained personnel under the supervision and instruction of electric experts may carry out any work on electric installations and equipment according to electric and technical rules. Switch off the systems and end-devices and makes sure they are de-energizd. Click the device onto a DIN EN mounting rail and check it is safely mounted! Only use the corresponding FO connection plugs. We draw your attention to the fact that any connection with a wrong connector may cause damage to the optical connections! Please also note that plugs with a locking device may only be mounted in a specific, defined position. Do not look into the optical sender! The focused and, depending on its wavelength, visible or invisible ray of light may damage your eyes! Connect the incoming fibre optic cable with the optical receiver and the outgoing optical fibre cable with the optical sender of the optical fibre system. Use the enclosed plug to protect the sender and receiver of the FO system against dirt and dust when not installed / not in use. Do not bend the FO cable too far and take note of the bending radius specified by the manufacturer. If bent too far, the cable may be damaged and / or the communication between the FO transducers can no longer be guaranteed. Switch on the operating voltage for the FO system. The systems require an operating voltage of 24 VDC connected at terminals VDC1 or VDC2 and GND. VDC1 and VDC2 are redundant voltage supply inputs with pole reversal protection. At the place of installation voltage must not exceed 250 V and short-circuit current must not exceed 1500 A. R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016 Page 7 of 12

Connection diagrams 9 Connection diagrams 9.1 SK-DRAG-GBIC-SX hazardous areas Power Optical fibre connection optional connections 9.2 SK-EL1000-2GU-3TX-4SX-opis hazardous areas Power Optical fibre connection optional connections Optical fibre connections Page 8 of 12 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016

Declaration of EC conformity 10 Declaration of EC conformity R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016 Page 9 of 12

Declaration of EC conformity Page 10 of 12 R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016

Release notes 11 Release notes The chapter entitled "Release Notes" contains all the changes made in every version of the Operating Instructions / manual. Version 01.00.00 Original version of the manual / operating instructions Version 01.00.01 Changing file name, exchange of characters "HM" with "OI" Changing of address and phone numbers Addition of IECEx data Addition of "Declaration of EC conformity" Text and formal corrections R. STAHL HMI Systems GmbH / OI_HM_GBIC_Switches_en_V_01_00_01.docx / 10.02.2016 Page 11 of 12

R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Phone: (switchboard) +49 (0) 221 76 806-1000 (Hotline) - 5000 Fax: - 4100 E-mail: (switchboard) office@stahl-hmi.de (hotline) support@stahl-hmi.de www.stahl.de www.stahl-hmi.de