SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe Installation Guide

Similar documents
2-Port RS232 Serial PCI with UART Quick Installation Guide

SATA II-150 PCI RAID

SATA II-150 PCI Quick Installation Guide

USB Port Hub Quick Installation Guide

USB 3.0 to 2.5" SATA HDD/SSD Mini Docking Quick Installation Guide

USB 3.0 & 2.0 Hub with Gigabit Ethernet and 5V/ 4A Adapter Quick Installation Guide

Serial ATA PCI Quick Installation Guide

DisplayPort 2-Port KVM Switch Installation Guide

DP Hi-Speed USB 4-Port PCIe Quick Installation Guide

USB 3.0 & Port Hub Quick Installation Guide

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

USB to Serial Quick Installation Guide

SuperSpeed USB 7-Port Hub Quick Installation Guide

SATA II PCIe RAID Quick Installation Guide

USB 3.0 to Gigabit Ethernet Adapter Installation Guide

USB 2.0 to SATA/IDE Quick Installation Guide

SATA II PCIe RAID Quick Installation Guide

USB 3.0 to SATA 3.5" Enclosure Installation Guide

USB to Serial Quick Installation Guide

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

Cool USB 2.0/eSATA to SATA Docking Duplicator Quick Installation Guide

IDE to SATA HDD Adapter Quick Installation Guide

Wireless-N High Power USB Wi-Fi Adapter Quick Installation Guide

FireWire 800 ExpressCard Quick Installation Guide

FireWire Hi-Speed USB Combo Quick Installation Guide

USB 2.0 Video Capture Device Quick Installation Guide

SATA-to-IDE Adapter Quick Installation Guide

SATA-to-IDE Adapter Quick Installation Guide

USB Port Extender Quick Installation Guide

USB 2.0 to DVI/VGA Pro Installation Guide

USB 3.0 to HDMI/DVI Dual Display Adapter Installation Guide

USB 3.0 to Multi Monitor Video Adapter Quick Installation Guide

4x1 USB HDMI KVM Switch Quick Installation Guide

USB 2.0 to VGA Quick Installation Guide

HDMI to 3G-SDI Converter Quick Installation Guide

Serial ATA 4-Channel RAID Quick Installation Guide

USB 2.0 Bay Media Card Reader Quick Installation Guide

ExpressCard 12-in-1 Reader/Writer Quick Installation Guide

USB 3.0 Flash Memory Card Reader Installation Guide

Wireless-N Wi-Fi Repeater/ Extender Quick Installation Guide

Micro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.

6-Port SATA II 150 PCI Host Card w/raid

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Solar Portable Battery Charger Quick Installation Guide

PCI SATA + PATA Raid Card

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Encore SATA2 RAID PCIe Card

Serial ATA RAID PCI Card

PCI ATA 133 RAID Controller Card. User Manual

SATA 150 RAID. user. Model MAN UM

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Serial ATA RAID PCI. User's Manual

1394 CardBus Quick Installation Guide

CF to Serial Adapter Quick Installation Guide

PCIe SATA 6G Raid Card

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering

SATA 6G PCIe Card User Manual Model: UGT-ST622

SATA PCI Express Adapter PEXSATA22I

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

The Sync and Charging Cable for Galaxy Tablets is a portable and easy-to-use sync and charging cable for a variety of Galaxy Tablets.

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

Serial ATA 2 Ports PCI Host

SSDNow For Desktops. Installation Guide

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

UltraATA 100 PCI RAID TM

esata 3.0Gbps RAID ExpressCard

SATA II 4 Port PCI RAID Card RC217 User Manual

2 Port esata or 4 Port SATA II PCI Express x4 Controller Card

2 Port PCI Express SATA 6Gbps Controller - 1x esata + 1x SATA

SATA/eSATA II PCI & PCI-E Card & CardBus

PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0

RocketRAID 600 Series 6Gb/s SATA RAID Host Adapters (RocketRAID 620 and RocketRAID 622)

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

IDE ATA/133 Controller

Low Profile Ultra ATA-133 RAID PCI Host

Rocket 640L/644L 6Gb/s SATA Host Adapter Quick Installation Guide

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

PCI SATA Controller Card Model: SY-PCI40010

Chapter 2 Installation

Guide to SATA Hard Disks Installation and RAID Configuration

1 Port PCI Express esata II Controller Card

ATA-133 IDE RAID Card. Version 1.1

DataCenter Gb/s SATA Host Adapter User Manual

2-Serial/1-Parallel Port PCI Adapter

Guide to SATA Hard Disks Installation and RAID Configuration

3-Port FireWire 800/400 PCI Host Card

PCI Express SATA / esata 6Gb/s RAID Card User Manual

HP SATA/SAS hard drive and Solid State Drive installation

Intel Rapid Storage Technology

Serial-ATA IDE Card. Version 1.0

Serial/ Parallel Combo PCi Card user manual

NVIDIA RAID Installation Guide

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

Ultra ATA 133 RAID PCI Pro

Transcription:

Introduction SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe Installation Guide The SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe is a high performance SATA host adapter which adds two Serial ATA 6Gb/s and two mini-sata SSD channels to your PCIe-equipped computer. Features and Benefits Compliant with Serial ATA specification, Revision 3.0 Connect up to 2 SATA HDDs and two internal mini-sata (msata) SSDs Built-in sockets for msata SSDs for space saving and superior drive performance Hybrid (HyperDuo) enables 80% of SSD performance at one-third the cost Hardware RAID to off load the host CPU for max performance. Supports RAID 0, 1 and 10 04-0925A 1

Supports Port Multiplier FIS-based and Native Command Queuing (NCQ) Supports TRIM to extend the life of SSDs for maximum durability Latch type msata connectors Tool-less msata SSD installation System Requirements Desktop PC with an available x4 (or larger) PCIe slot Windows 8 (32-/64-bit) / 7 (32-/64-bit) / Vista (32-/64-bit) / XP (32-/64-bit) /Server 2003 & 2008 (32/64-bit) / Server 2008 R2 Package Contents SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe Serial ATA data cables (2) Spare low profile bracket Driver CD Installation guide 2

Layout + - SATA 3 SATA 2 (msata SSD) (msata SSD) HDD LED pins (Front chassis LED) SATA 1 (top) SATA 0 (bottom) Figure 1: Layout Application Two msata SSDs installed to the SSD slot Figure 2: Application Two HDDs or SSDs connected to the internal SATA channels 3

Hardware Installation msata SSD Installation Install the msata SSD to the SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe before card installation. NOTE: Only msata SSDs can be used with the controller's msata SSD interface. Check your SSD's data sheet or manufacturer for more information. 1. Insert the msata SSD's msata interface into the controller's msata interface. See Figure 3a. 2. Gently push the bottom of the msata SSD down until it snaps into the slot. Make sure the msata SSD is secured by the holding buckles. Repeat steps 1 and 2 for the 2nd msata SSD, if needed. See Figure 3b. msata SSD msata SSD msata Interface Figure 3a Figure 3b 4

3. To uninstall the msata SSD, simply release it from the two holding buckles first, then the msata SSD can be removed from the controller's msata interface. PCIe Card Installation General instructions for installing the card are provided below. Since the design of computer cases and motherboards vary, refer to your computer's reference manual for further information, if needed. Static Electricity Discharge may permanently damage your system. Discharge any static electricity build up in your body by touching your computer case for a few seconds. Avoid any contact with internal parts and handle cards only by their external edges. 1. Turn OFF the power to your computer and any other connected peripheral devices. 2. Unplug the power cord from the back of the computer. 3. Remove your computer cover. 5

4. Remove the slot bracket cover from an available x4 or larger PCI Express slot. 5. Carefully align the card's bus connector with the selected PCI Express slot on the motherboard. Push the board down firmly, but gently, until it is well seated. 6. Replace the slot bracket holding screw to secure the card. SATA HDD Installation 1. Install your SATA hard disk drive(s) into the computer. 2. Connect the Serial ATA hard disk drive(s) to the system power supply. Note: For hard drives with both SATA power connector and legacy 4-pin connector, use either the SATA power connector or the legacy 4-pin power connector. Using both power connectors may damage the hard drive. 3. Connect one end of the Serial ATA cable to the hard disk drive. See Figure 4. 6

Serial ATA Data Cable Power Figure 4: SATA hard disk drive connections 4. Attach the other end of the Serial ATA data cable to the Serial ATA connector on the SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe. 5. Follow the same instructions to connect the second hard drive, if needed. Device connection is now complete. RAID Arrays This controller can be configured for HyperDuo*, RAID 0, 1 and 10, if needed. If you don't need HyperDuo, RAID 0, 1 or 10, please proceed to Driver Installation on page 14. RAID Arrays are setup in the BIOS. *Note: HyperDuo requires one, two or three SSD drives. 7

HyperDuo This array to be used with 1, 2 or 3 Solid-State drives (SSDs) + 1 SATA hard drive to leverage the speed of SSD with the storage capacity of a traditional SATA hard disk drive. 1. As the BIOS boots, press Ctrl+M when prompted to enter the RAID BIOS. 2. At the next screen select HBA 0: Marvell 0, press Enter. Select Configuration Wizard, then press Enter. 3. Use the Up or Down arrow key to choose a drive. Press the Spacebar to select the drive. Perform the same procedure with the other drive(s), you want to add to the array. When you are finished selecting the drives, press Enter. 4. Select HyperDuo or RAID Level, press Enter. Use the Up or Down arrow key to select either Safe (for fault tolerance) or Capacity (for the best read/write performance), then press Enter. 8

5. Use the Up or Down arrow key to select Next, then press Enter. When asked Do you want to create this virtual disk? press Y to select Yes, to save the array. 6. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS Setup? press Y to exit and reboot. RAID 0 (Striping) This RAID array to be used on New/Blank hard drives. Striping will destroy data on the hard drive. A minimum of 2 drives are needed to configure this array. 1. As the BIOS boots, press Ctrl+M when prompted to enter the RAID BIOS. 2. At the next screen select HBA 0: Marvell 0, press Enter. Select Configuration Wizard, then press Enter. 3. Use the Up or Down arrow key to choose a hard drive. Press the Spacebar to select the hard drive. Perform the same procedure with the other hard drive(s), you want to add to the array. When you are finished selecting the hard drives, press Enter. 9

4. Select HyperDuo or RAID Level, press Enter. Select RAID 0, then press Enter. 5. Use the Up or Down arrow key to select Next, then press Enter. When asked Do you want to create this virtual disk? press Y to select Yes, to save the array. 6. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS Setup? press Y to exit and reboot. RAID 1 (Mirror) Two drives are needed to make a Mirror. 1. As the BIOS boots, press Ctrl+M when prompted to enter the RAID BIOS. 2. At the next screen select HBA 0: Marvell 0, press Enter. Select Configuration Wizard, then press Enter. 3. Use Up or Down arrow key to choose a hard drive. Press Spacebar to select the hard drive. Perform the same procedure with the other hard drive. Once both hard drives are selected press Enter. 4. Select HyperDuo or RAID Level, press Enter. Select RAID1, then press Enter. 10

5. Use the Up or Down arrow key to select Next, then press Enter. When asked Do you want to create this virtual disk? press Y to select Yes, to save the array. 6. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS Setup? press Y to exit and reboot. RAID 10 (Mirror+Striping) Four drives are needed to make a RAID10. 1. As the BIOS boots, press Ctrl+M when prompted to enter the RAID BIOS. 2. At the next screen select HBA 0: Marvell 0, press Enter. Select Configuration Wizard, then press Enter. 3. Use Up or Down arrow key to choose hard drive. Press Spacebar to select the hard drive. Perform the same procedure with the other hard drives. Once all hard drives are selected press Enter. 4. Select HyperDuo or RAID Level, press Enter. Select RAID 10, then press Enter. 11

5. Use the Up or Down arrow key to select Next, then press Enter. When asked Do you want to create this virtual disk? press Y to select Yes, to save the array. 6. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS Setup? press Y to exit and reboot. Rebuilding a Failed Mirror Set When a failure to one member occurs, you will be notified by the RAID BIOS during boot up. The steps below will guide you in rebuilding a failed mirror set. 1. Replace the failed drive with one of equal or greater capacity, then boot the computer. 2. As the BIOS boots press Ctrl+M when prompted to enter the RAID BIOS. 3. Select New_VD, press Enter. Select Rebuild then press Enter. 4. Select the new hard drive under Free Physical Disks. 5. Press Spacebar to select hard drive, then press Enter. 12

6. When asked Do you want to rebuild with selected physical disk on this vd?, press Y to select Yes. The mirror will begin rebuilding. Do not interfere with the process until completion. 7. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS setup? press Y to exit and reboot. Deleting RAID Arrays Deleting a RAID array will destroy data on the hard drives. Please backup all data on your hard drive before deleting any RAID array. 1. As the BIOS boots press Ctrl+M when prompted to enter the RAID BIOS. 2. Select New_VD press Enter. Select Delete then press Enter. 3. When asked Do you want to delete this virtual disk? press Y to select Yes. 4. When asked Do you want to delete MBR from this virtual disk?, press Y to select Yes. 13

5. Press F10 to exit the BIOS. When asked Do you want to exit from Marvell BIOS setup? press Y to exit and reboot. Driver Installation This section provides information on how to install the drivers. Windows 8 (32-/64-bit) / Windows 7 (32-/ 64-bit) / Server 2008 R2 For New Installation 1. Setup the RAID array prior to Windows installation. If RAID is not required, go directly to step 2. 2. Follow Windows installation procedure. 3. At the Windows desktop: For Windows 8 / 7: Right click Computer, click Manage, click Device Manager. For Server 2008 R2: Click Computer, click Manage. Double click Diagnostics, click Device Manager. 4. Right click Marvell Console or Marvell Console ATA Device under Other devices, click Update Driver Software. 14

5. Click Browse my computer for driver software, insert the driver CD. Close the CD autoplay window if prompted. 6. For 32-bit: Type D:\Drivers\storport\i386, click Next. (Change D: to match your CD- /DVD-ROM drive letter) For 64-bit: Type D:\Drivers\storport\ amd64, click Next. (Change D: to match your CD-/DVD-ROM drive letter) 7. Click Close, then restart the computer. For Existing Installation 1. Setup the RAID array prior to driver installation and boot up to Windows. If RAID is not required, simply boot up Windows and go directly to step 2. 2. For Windows 8 / 7: Right click Computer, click Manage, click Device Manager. For Server 2008 R2: Click Computer, click Manage. Double click Diagnostics, click Device Manager. 3. Right click Marvell Console or Marvell Console ATA Device under Other devices, click Update Driver Software. 15

4. Click Browse my computer for driver software, insert the driver CD. Close the CD autoplay window if prompted. 5. For 32-bit: Type D:\Drivers\storport\i386, click Next. (Change D: to match your CD-/DVD-ROM drive letter) For 64-bit: Type D:\Drivers\storport\ amd64, click Next. (Change D: to match your CD-/DVD-ROM drive letter) 6. Click Close, then restart the computer. Windows Vista (32-/64-bit) / Server 2008 (32-/64-bit) For A New Installation 1. Setup the RAID array prior to Windows installation. If RAID is not required, go directly to step 2. 2. Follow Windows installation procedure. 3. After booting up the Windows, click Cancel at the Found New Hardware window. 4. For Windows Vista: Right click Computer, click Manage, click Continue, click Device Manager. 16

For Server 2008: Right click Computer, click Manage. Double click Diagnostics, click Device Manager. 5. Right click Marvell Console ATA Device under Other devices, click Update Driver Software. 6. Click Browse my computer for driver software. 7. Insert the driver CD. Close the CD autoplay window if prompted. 8. For 32-bit: Type D:\Drivers\storport\i386, click Next. (Change D: to match your CD-/DVD-ROM drive letter) For 64-bit: Type D:\Drivers\storport\ amd64, click Next. (Change D: to match your CD-/DVD-ROM drive letter) 9. Click Close, then restart the computer. For Existing Installation 1. Setup the RAID array prior to driver installation and boot up to Windows. If RAID is not required, simply boot up Windows and go directly to step 2. 17

2. At the Found New Hardware window, click Cancel. 3. For Windows Vista: Click Computer, click Manage, click Continue, click Device Manager. For Server 2008: Click Computer, click Manage. Double click Diagnostics, click Device Manager. 4. Right click Marvell Console ATA Device under Other devices, click Update Driver Software. 5. Insert the driver CD. Close the CD autoplay window if prompted. 6. Click Browse my computer for driver software. 7. For 32-bit: Type D:\Drivers\storport\i386, click Next. (Change D: to match your CD-/DVD-ROM drive letter) For 64-bit: Type D:\Drivers\storport\ amd64, click Next. (Change D: to match your CD-/DVD-ROM drive letter) 8. Click Close, then restart the computer. 18

Windows XP (32-/64-bit) / Server 2003 (32-/64-bit) Important: New Installation is not supported by Windows XP and Windows Server 2003. For Existing Installation 1. Setup the RAID array prior to driver installation and boot up Windows. If RAID is not required, simply boot up Windows and go directly to step 2. 2. At the Found New Hardware window, click No, not this time, click Next. Skip this step if not prompted. 3. Click Install from a specific location (advanced), click Next. 4. Check Include this location in the search, uncheck the other box. 5. Insert driver CD. For 32-bit: Type D:\Drivers\miniport\i386, click Next. (Change D: to match your CD-/DVD-ROM drive letter) For 64-bit: Type D:\Drivers\miniport\ amd64, click Next. (Change D: to match your CD-/DVD-ROM drive letter) 19

6. Click Finish. 7. Repeat steps 2-6. 8. Restart the computer. To Verify Windows Installation 1. Use Device Manager to verify installation. For Windows 8 / 7 / XP / Server 2003: Right click Computer or My Computer, click Manage, click Device Manager. For Windows Vista: Right click Computer, click Manage, click Continue. Click Device Manager. For Windows Server 2008 / 2008 R2: Right click Computer, click Manage. Double click Diagnostics, click Device Manager. 2. Double click System devices, Marvell Unify Configuration should be displayed. Marvell Storage Utility Follow the instructions below to install the Marvell Storage Utility GUI. 1. Double click MSUSetup in the GUI folder on your software CD. 20

2. At the User Account Control, click Yes or Continue. Skip this step if not prompted. 3. At Welcome to the Marvell MSU V4 Setup Wizard, click Next. 4. At License Agreement, select I accept the terms of the License Agreement, click Next. 5. Click Next again. 6. Change the Destination folder if you want to change it; otherwise, click Install. 7. Click Allow access at the Windows Security Alert. Skip this step if not prompted. 8. At the Completing the Marvell MSU V4 Setup Wizard, click Finish. 9. After successful installation, the MSU GUI is ready for use. Enable the software by double click on it. 10. Type in the Username and Password to log in. Username and Password are your Windows user name and password. If you have a user name but no password, please leave the password field blank. 21

Figure 5 11. After log in, you can access to the MSU user interface for further VD management. Refer to your UserGuide on the software CD for more details. Figure 6 22

Technical Support and Warranty QUESTIONS? SIIG s Online Support has answers! Simply visit our web site at www.siig.com and click Support. Our online support database is updated daily with new drivers and solutions. Answers to your questions could be just a few clicks away. You can also submit questions online and a technical support analyst will promptly respond. SIIG offers a 5-year manufacturer warranty with this product. This warranty covers the original purchaser and guarantees the product to be free of any defects in materials or workmanship for five (5) years from the date of purchase of the product. SIIG will, at our discretion, repair or replace (with an identical product or product having similar features and functionality) the product if defective in materials or workmanship. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Please see our web site for more warranty details. If you encounter any problems with this product, please follow the procedures below. A) If it is within the store's return policy period, please return the product to the store where you purchased from. B) If your purchase has passed the store's return policy period, please follow the steps below to have the product repaired or replaced. Step 1: Submit your RMA request. Go to www.siig.com, click Support, then REQUEST A PRODUCT REPLACEMENT to submit a request to SIIG RMA or fax a request to 510-657-5962. Your RMA request will be processed, if the product is determined to be defective, an RMA number will be issued. Step 2: After obtaining an RMA number, ship the product. Properly pack the product for shipping. All accessories that came with the original package must be included. Clearly write your RMA number on the top of the returned package. SIIG will refuse to accept any shipping package, and will not be responsible for a product returned without an RMA number posted on the outside of the shipping carton. You are responsible for the cost of shipping to SIIG. Ship the product to the following address: SIIG, Inc. 6078 Stewart Avenue Fremont, CA 94538-3152, USA RMA #: SIIG will ship the repaired or replaced product via Ground in the U.S. and International Economy outside of the U.S. at no cost to the customer. 23

About SIIG, Inc. Founded in 1985, SIIG, Inc. is a leading manufacturer of IT connectivity solutions (including Serial ATA and Ultra ATA Controllers, FireWire, USB, and legacy I/O adapters) that bridge the connection between Desktop/ Notebook systems and external peripherals. SIIG continues to grow by adding A/V and Digital Signage connectivity solutions to our extensive portfolio. SIIG products offer comprehensive user manuals, many user-friendly features, and are backed by an extensive manufacturer warranty. High quality control standards are evident by the overall ease of installation and compatibility of our products, as well as one of the lowest defective return rates in the industry. SIIG products can be found in computer retail stores, mail order catalogs, through major distributors, system integrators, and VARs in the Americas and the UK, and through e-commerce sites. PRODUCT NAME SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe FCC RULES: TESTED TO COMPLY WITH FCC PART 15, CLASS B OPERATING ENVIRONMENT: FOR HOME OR OFFICE USE FCC COMPLIANCE STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. THE PARTY RESPONSIBLE FOR PRODUCT COMPLIANCE SIIG, Inc. 6078 Stewart Avenue Fremont, CA 94538-3152, USA Phone: 510-657-8688 SATA 6Gb/s 2i+2 msata SSD Hybrid PCIe is a trademark of SIIG, Inc. SIIG and the SIIG logo are registered trademarks of SIIG, Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. All other names used in this publication are for identification only and may be trademarks of their respective owners. November, 2013 Copyright 2013 by SIIG, Inc. All rights reserved.