FICON to ESCON Converter Planning Specifications. Rev 052814



Similar documents
The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

How To Establish IPSec VPN connection between Cyberoam and Mikrotik router

SecureLinx Spider Duo Quick Start Guide

Storage System. Planning Checklist. EC E1, First Edition

QuickSpecs. HP IP Console Switch with Virtual Media Overview

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

V310 Support Note Version 1.0 November, 2011

How to Set Up Your NSM4000 Appliance

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

ALL-ZC-2140P-DVI PCoIP Zero Client Overview

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Cisco 1700 Router Overview

ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004

TrueAlarm Fire Alarm Systems

Configure VPN between ProSafe VPN Client Software and FVG318

TrueAlarm Fire Alarm Systems

Job Aid Pre-Installation Information S8500 Media Server

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

QuickSpecs. Models HP Server Console Switches

Use Shrew Soft VPN Client to connect with IPSec VPN Server on RV130 and RV130W

3500/22M Transient Data Interface

DFL-210/260, DFL-800/860, DFL-1600/2500 How to setup IPSec VPN connection

RSA Security Analytics. S4 Broker Setup Guide

DD670, DD860, and DD890 Hardware Overview

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

ALL-ZC-2321P PCoIP Zero Client Overview

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

Configure an IPSec Tunnel between a Firebox Vclass & a Check Point FireWall-1

Lab 4.4.8a Configure a Cisco GRE over IPSec Tunnel using SDM

VAC 50/60Hz Power Adapter

Reliable, Consistent, Quality

MDL 100S Product Description

VPNC Interoperability Profile

HP ProLiant DL380 G5 High Availability Storage Server

Chapter 5 Cubix XP4 Blade Server

* Rev A* PN Rev A 1

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

Configuring IPsec VPN with a FortiGate and a Cisco ASA

Setting Up the Cisco Unified IP Phone

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

QuickSpecs. HP 480/277 Volt Solutions. Overview

BR-800. ProHD Broadcaster. Easy Set-Up Guide V 1.01

CG2100 Carrier Grade Server. Document Revision 1.2

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

HP Server Console Switch with Virtual Media Overview

AVer EVC. Quick Installation Guide. Package Contents. 8. Mini Din 8 pin MIC Cable. 1. Main System. 9. HDMI Cable. 2. Camera. 10.

Cyberoam Configuration Guide for VPNC Interoperability Testing using DES Encryption Algorithm

Quick Start Guide. 500 Series Stackable Managed Switches

Configuring TheGreenBow VPN Client with a TP-LINK VPN Router

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Cisco Secure Control Access System 5.8

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

MCR1900 Media Converter 19-Slot Chassis

Connecting to the Internet. LAN Hardware Requirements. Computer Requirements. LAN Configuration Requirements

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Acano solution. Acano Solution Installation Guide. Acano. January B

QuickSpecs. HP IP Console Switches. Overview

Adit 3000 Series Part Guide

1U Multi-Function Fibre Enclosure

Pretium EDGE HD Solutions

InstaPATCH ZERO Solution Guide

GigaVUE-420. The Next Generation. Data Access Switch. Gigamon Systems. Intelligent Data Access Networking

Starting a Management Session

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Gigabit Switching Ethernet Media Converters - Product User Guide

Configuration Guide. How to establish IPsec VPN Tunnel between D-Link DSR Router and iphone ios. Overview

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Delphi+ System Requirements

SECURE Fiber Optic Products

ALL-ZC-2321P-PoE PCoIP PoE Zero Client Overview

STONEGATE IPSEC VPN 5.1 VPN CONSORTIUM INTEROPERABILITY PROFILE

Firewall Troubleshooting

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

CounterACT 7.0 Single CounterACT Appliance

ALL-AIO-2321P ZERO CLIENT

How to Determine the Right Fiber Optic Network Backup Switch For Your Application

FriendlyNET FX Slot Modular Switch. User s Manual

Pretium Connector Housings

Chapter 6 Basic Virtual Private Networking

3.5 EXTERNAL NETWORK HDD. User s Manual

Networking Devices. Lesson 6

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

IPsec VPN Application Guide REV:

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

Product Information D23m Digital I/O System

Global VPN Client Getting Started Guide

Cisco Expressway CE500 Appliance

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Broadband Phone Gateway BPG510 Technical Users Guide

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

PCIeBPMC (PCI/PCI-X Bus Compatible) Bridge based PCIe and PMC Compatible Adapter Carrier Front View shown with 1 installed fans model # PCIeBPMC-FAN2

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Barracuda Link Balancer

Transcription:

FICON to ESCON Converter Planning Specifications Rev 052814

FICON to ESCON Converter GENERATION 3 Solid State Drives in RAID1 Configuration Power ID Front View 0 1 2U Pull-out Status Panel FICON LC Duplex Ports ESCON Harness Ports Rear View B0 B1 0 1 Power Supplies 1 2 NIC Ports IMM Module / KVM Port ID Light

ESBT ESCON to B/T Module for Prizm ESCON Duplex Connector -OR- MT-RJ Connector What is ESBT? The Optica ESBT is an ESCON to Bus and Tag Converter module that allows attachment of parallel (Bus/Tag) devices to FICON channels via Prizm. The ESBT provides serial-to-parallel conversion for the Prizm ESCON ports and supports the attachment of a single parallel device. Note ESBT is functionally different than an Optica FXBT or an IBM 9034 and can only be used in conjunction with Prizm. The FXBT and 9034 are not interchangeable with the ESBT. The Optica FXBT and IBM 9034 ONLY attach to CHPID types CVC or CBY, while the ESBT attaches to a CNC channel type from Prizm and therefore any existing FXBT or 9034 MUST be replaced with an ESBT for connectivity to FICON channels.

Planning Specifications Power Prizm: Dual (2) Power Supplies with IEC-C14 AC outlets; 110/220 Volt; 50/60 Hz, auto-sensing (equipment side) Current = 110V-3.0 amps total / 220V-1.5 amps total (balanced across 2 Hot-Swap Power Supplies) Watts = 360; BTU = 1229 Power Cords: (2) P/N 14313; 110V NEMA 5-15P to IEC-60320-C13; 6 ft. (standard for North America) (2) country-specific power cords included (standard for all countries outside of North America) (2) P/N HSBS-1310; 110V/220V IEC-60320-C14 to IEC-60320-C13; 6 ft. PDU-style (standard) P/N 14313 P/N HSBS-1310 ESBT: (1) Power Supply with IEC-C14 AC outlet; 110/220 Volt; 50/60 Hz, auto-sensing (equipment side) Current = 110V-.2 amps / 220V-.1 amps Power Cords: (1) P/N 14313; 110V NEMA 5-15P to IEC-60320-C13; 6 ft. (standard for North America) (1) country-specific power cord included (standard for all countries outside of North America) (1) P/N HSBS-1310; 110V/220V IEC-60320-C14 to IEC-60320-C13; 6 ft. PDU-style (optional, must request) Dimensions Prizm: Height = 2U, 86.5 mm / 3.4 inches; Width = 445 mm / 17.5 inches; Depth = 746 mm / 29.4 inches Sliding rails and cable management kit standard with each unit, 19 inch rack mount compatible ESBT: Height = 5.08 cm / 2 inches; Width = 19.37 cm / 7.63 inches; Depth = 30.48 cm / 12 inches Optional 19 inch rack mount kit available, accommodates qty 8 ESBT s vertically

Cabling Planning Specifications ** The purpose of these cables is to convert the native hardware connector only ** They cannot be used for connecting 2 hardware elements ** Cables from Prizm to the I/O device or ESBT are supplied by the user Prizm FICON: LC Duplex Connector LX - Longwave GBICs (singlemode 9u,1310 nm - Yellow) SX - Shortwave GBICs (multimode 50u, 850 nm - Aqua 10G) ESCON: MT-RJ Connector Harness (standard); Multimode 62.5u ESCON Duplex Connector Harness (optional); Multimode 62.5u LX-Singlemode SX-Multimode PN: 27072-003M 4 Port MTP to MTRJ Harness (Standard) ESCON Harness connects to B0 or B1 and fans out to four ESCON connections. PN: 27099-003M 4 Port MTP to Duplex Harness (Optional) ESBT ESCON: MTRJ Connector or ESCON Duplex Connector (Both types in stock) Multimode 62.5u Bus & Tag: Proprietary Y Cable. If replacing Optica FXBT converter, existing Y cable can be re-used. If replacing IBM 9034 converter, a Y cable must be purchased with ESBT PN: 02-JT-6R-02M ESCON MTRJ (Plug) to Duplex (Jack) Conversion PN: 02-JQ-6R-002 ESCON MTRJ (Jack) to Duplex (Plug) Conversion Y cable P/N 149510

MTP B0 ESCON Ports 0-3 ** Prizm 1:2 only uses P0 & P1 of B0 Harness Prizm Port Layout and Assignments P0 = Address P1 = P2 = P3 = B0 B1 MTP B1 ESCON Ports 4-7 ESCON Harness Connections P0 = Address P1 = P2 = P3 = PN: 27072-003M 4-Port MTP to MTRJ Harness (Standard) ESCON Harness connects to B0 and/or B1 and fans out to four port connections. NIC-1 Maintenance default setting 192.168.253.250 Partially Configurable FICON LC Duplex NIC-2 Customer/VPN default setting 192.168.254.254 Fully Configurable 0 1 CHPID SW Port NIC-3/NIC-4 Not used CHPID SW Port IP KVM Maintenance Note: Prizm may be shipped with both Singlemode (longwave LX, 1310 nm) optics which can be identified by a BLUE locking bail, and Multimode (shortwave SX, 850nm) optics which can be identified by a BLACK locking bail. It is the responsibility of the installer to ensure proper optics are used. (Alternate optics are shipped in a BLACK accessory box) PN: 27099-003M 4-Port MTP to Duplex Harness (Optional) ESCON Harness connects to B0 and/or B1 and fans out to four port connections. locking bail Blue Black. Longwave (LX) Shortwave (SX) Yellow (9 micron) Aqua (50 micron) P/N 27059 P/N 27068

Prizm/ESBT ESCON Cabling Coupler fixed to connector Standard MTP Harness to MT-RJ PN: 27072-003M P R I Z m Standard MTP Harness to MT-RJ 27072-003M B0 0-3 MTP Optional MTP Harness to Duplex 27099-003M B1 4-7 MTP P0 P1 P2 P3 MT-RJ P0 P1 P2 No pins IO DEVICE ESBT Customer supplied jumper cables IO DEVICE ESBT Y-cable Y-cable IO DEVICE IO DEVICE Optional MTP Harness to Duplex PN: 27099-003M P3 ESCON Duplex Connectors and Conversion Cables MTP MTP Standard MTP Harness to MT-RJ 27072-003M B0 B1 Optional MTP Harness to Duplex 27099-003M P0 P1 P2 P3 P0 P1 P2 P3 Customer supplied MTRJ jumper cables No pins Customer supplied ESCON Duplex jumper cables Optica supplied MTRJ (Jack) to Duplex (Plug) Conversion Coupler fixed to connector No conversion needed? Optica supplied MTRJ (Plug) to Duplex (Jack) Conversion No pins PN: 02-JQ-6R-002 ESCON MTRJ (Jack) to Duplex (Plug) Conversion Ships with Duplex ESBT ESBT Duplex PN: 02-JT-6R-02M ESCON MTRJ (Plug) to Duplex (Jack) Conversion Ships with MT-RJ ESBT ESBT MT-RJ

IOCDS Example Supporting Prizm 2:8 (FICON Switched) ID MSG2='SYSS.IODF51-2008-02-27 15:47',SYSTEM=(2094,1), * TOK=('Z9HDC2',008000069B902094154706160108058F00000000,0* 0000000,'08-02-27','15:47:06','SYSS','IODF51') RESOURCE PARTITION=((CSS(0),(A000,5),(B430,7),(D000,1),(D100,2* ),(D200,3),(E300,4),(ICFB,F),(MVSR,8),(RESP,6))), * MAXDEV=((CSS(0),65280,0)) CHPID PATH=(CSS(0),34),SHARED, * PARTITION=((A000,B430,D000,D100,D200,E300,MVSR,RESP),(=)* ),SWITCH=02,PCHID=1D2,TYPE=FC CHPID PATH=(CSS(0),35),SHARED, * PARTITION=((A000,B430,D000,D100,D200,E300,MVSR,RESP),(=)* ),SWITCH=03,PCHID=1D3,TYPE=FC CNTLUNIT CUNUMBR=0510,PATH=((CSS(0),34,35)),CUADD=0, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=510,UNITADD=00,CUNUMBR=(0510),STADET=Y, * CNTLUNIT CUNUMBR=0511,PATH=((CSS(0),34,35)),CUADD=10, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=511,UNITADD=00,CUNUMBR=(0511),STADET=Y, * CNTLUNIT CUNUMBR=0512,PATH=((CSS(0),34,35)),CUADD=20, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=512,UNITADD=00,CUNUMBR=(0512),STADET=Y, * CNTLUNIT CUNUMBR=0513,PATH=((CSS(0),34,35)),CUADD=30, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=513,UNITADD=00,CUNUMBR=(0513),STADET=Y, * CNTLUNIT CUNUMBR=0514,PATH=((CSS(0),34,35)),CUADD=40, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=514,UNITADD=00,CUNUMBR=(0514),STADET=Y, * CNTLUNIT CUNUMBR=0515,PATH=((CSS(0),34,35)),CUADD=50, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=515,UNITADD=00,CUNUMBR=(0515),STADET=Y, * CNTLUNIT CUNUMBR=0516,PATH=((CSS(0),34,35)),CUADD=60, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=516,UNITADD=00,CUNUMBR=(0516),STADET=Y, * CNTLUNIT CUNUMBR=0517,PATH=((CSS(0),34,35)),CUADD=70, * UNITADD=((00,016)),LINK=((CSS(0),020E,030E)), IODEVICE ADDRESS=517,UNITADD=00,CUNUMBR=(0517),STADET=Y, * How to produce IOCDS Report HCD - ID, RESOURCE PARTITION, CHPID PATH, CNTLUNIT CUNUMBR, IODEVICE ADDRESS. - From your TSO session s Master Application Menu select HC HCD - Hardware Configuration Definition. - In the I/O definition file field type the name of the currently active IODF and select option 2 to activate or process configuration data. - From the Activate or Process Configuration Data menu select 3 to build an IOCP input dataset. - Select the appropriate processor by placing a / in the appropriate field in front of the processor ID and hit enter to continue. - Enter a title in the Title1 field and the IOCP destination dataset name. Ex. USERID.IODF02.JAN2909 and hit enter; this will submit the job to create the IOCP dataset. - You can then download the newly created dataset using your 3270 emulation or via FTP. Prizm Port B0,P0 (Port 0) Prizm Port B0,P1 (Port 1) Prizm Port B0,P2 (Port 2) Prizm Port B0,P3 (Port 3) Prizm Port B1,P0 (Port 4) Prizm Port B1,P1 (Port 5) Prizm Port B1,P2 (Port 6) Prizm Port B1,P3 (Port 7)

IOCDS Example Supporting Prizm 2:8 (No FICON Switch / Direct Connect) ID MSG2='SYSS.IODF51-2008-02-27 15:47',SYSTEM=(2094,1), * TOK=('Z9HDC2',008000069B902094154706160108058F00000000,0* 0000000,'08-02-27','15:47:06','SYSS','IODF51') RESOURCE PARTITION=((CSS(0),(A000,5),(B430,7),(D000,1),(D100,2* ),(D200,3),(E300,4),(ICFB,F),(MVSR,8),(RESP,6))), * MAXDEV=((CSS(0),65280,0)) CHPID PATH=(CSS(0),34),SHARED, * PARTITION=((A000,B430,D000,D100,D200,E300,MVSR,RESP),(=)* ), PCHID=1D2,TYPE=FC CHPID PATH=(CSS(0),35),SHARED, * PARTITION=((A000,B430,D000,D100,D200,E300,MVSR,RESP),(=)* ),PCHID=1D3,TYPE=FC CNTLUNIT CUNUMBR=0510,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=0, IODEVICE ADDRESS=510,UNITADD=00,CUNUMBR=(0510),STADET=Y, * CNTLUNIT CUNUMBR=0511,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=10, IODEVICE ADDRESS=511,UNITADD=00,CUNUMBR=(0511),STADET=Y, * CNTLUNIT CUNUMBR=0512,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=20, IODEVICE ADDRESS=512,UNITADD=00,CUNUMBR=(0512),STADET=Y, * CNTLUNIT CUNUMBR=0513,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=30, IODEVICE ADDRESS=513,UNITADD=00,CUNUMBR=(0513),STADET=Y, * CNTLUNIT CUNUMBR=0514,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=40, IODEVICE ADDRESS=514,UNITADD=00,CUNUMBR=(0514),STADET=Y, * CNTLUNIT CUNUMBR=0515,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=50, IODEVICE ADDRESS=515,UNITADD=00,CUNUMBR=(0515),STADET=Y, * CNTLUNIT CUNUMBR=0516,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=60, IODEVICE ADDRESS=516,UNITADD=00,CUNUMBR=(0516),STADET=Y, * CNTLUNIT CUNUMBR=0517,PATH=((CSS(0),34,35)), * UNITADD=((00,016)),CUADD=70, IODEVICE ADDRESS=517,UNITADD=00,CUNUMBR=(0517),STADET=Y, * How to produce IOCDS Report HCD - ID, RESOURCE PARTITION, CHPID PATH, CNTLUNIT CUNUMBR, IODEVICE ADDRESS. - From your TSO session s Master Application Menu select HC HCD - Hardware Configuration Definition. - In the I/O definition file field type the name of the currently active IODF and select option 2 to activate or process configuration data. - From the Activate or Process Configuration Data menu select 3 to build an IOCP input dataset. - Select the appropriate processor by placing a / in the appropriate field in front of the processor ID and hit enter to continue. - Enter a title in the Title1 field and the IOCP destination dataset name. Ex. USERID.IODF02.JAN2909 and hit enter; this will submit the job to create the IOCP dataset. - You can then download the newly created dataset using your 3270 emulation or via FTP. Prizm Port B0,P0 (Port 0) Prizm Port B0,P1 (Port 1) Prizm Port B0,P2 (Port 2) Prizm Port B0,P3 (Port 3) Prizm Port B1,P0 (Port 4) Prizm Port B1,P1 (Port 5) Prizm Port B1,P2 (Port 6) Prizm Port B1,P3 (Port 7)

Customer Management of Prizm Prizm Management Prizm is managed via a browser-based GUI Customer personnel can manage and monitor Prizm via any workstation attached to the customer s internal LAN. No client software or application required Prizm has two LAN interfaces: NIC1 and NIC2 NIC1 is used exclusively for on-site access by a service technician NIC2 is used by the customer for local access to the Prizm and/or by Optica for remote support access to the Prizm.

Optica Service Access Options for Prizm There are 3 possible service access scenarios for Optica (in order of preference): Remote VPN and Customer has local LAN access to Prizm Optica is given secure VPN access to Prizm units for providing the optimal level of maintenance and support to the customer. Remote VPN access allows Optica technicians to proactively and efficiently perform routine health checks and capture diagnostic and log information for troubleshooting in the event of a problem. No Remote VPN; Customer has local LAN access to Prizm Without VPN access, remote desktop sessions are the next best alternative using WebEx or similar application. Optica Support Engineers can remotely assist with Prizm management and/or support with coordination and oversight by customer personnel. In the absence of a WebEx session, Optica must rely on the customer to access the Prizm unit(s) independently to capture and email the necessary support information. No Remote VPN; No local LAN access to Prizm Access to Prizm is not available via VPN or local LAN connectivity and therefore can only be accomplished via a PC/laptop directly attached to the NIC1 port of Prizm. Optica provides telephone support to on-site personnel to collect and email the necessary support information to Optica. 11

Prizm Remote Access - VPN Optica requires access to HTTP(80) and SSH (22). VPN Tunnel Phase 1 and Phase 2 parameters Listed below are the parameters recommended for the Phase 1 and Phase 2 VPN settings. The parameters can be adapted to meet the customer s requirements. The customer should also provide the shared secret (pre-shared key) for Phase 1. VPN Phase 1 Policy Optica IP address: 74.92.211.203 Exchange mode: Main or Agressive Encryption: AES 256 Authentication: SHA-1 Auth. Method: pre shared key (to be provided by the customer) DH Group: Group 2 (1024bit) SA Lifetime: 28800 seconds VPN Phase 2 Policy Remote Endpoint: Customer VPN IP address Remote Encryption Domain: 74.92.211.193 mask 255.255.255.248 (Optica Technologies Support Subnet) Local Encryption Domain: To be set by the customer to include IP addresses for locally attached Prizm units SA Lifetime: 3600 seconds Encryption algorithm: AES 256 Integrity algorithm: SHA-1