Industrial Cooling Systems

Similar documents
Electronic Flow Switches

A Guide to Trouble-Free Cooling Towers

Sanitary Type Electronic Flow Switches

COOLING WATER MANAGEMENT

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

By: Jaap Hoogland SPX Cooling Technologies GmbH. CW /Jaap Hoogland/ Seawater Cooling Tower Circuits 1

B-Series Temperature Switches

Nirvana. Cycling Refrigerated Dryers

2014 Service Technician Training Program Closed Loop Systems

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

CONTROL OF LEGIONELLA AUDIT PROFORMA

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Flow switches Series AD/VH

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Alfa Laval PureBallast 3.1

In-Line Electronic Flow Switches

Plastic tube flowmeters Series PT/PS

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

Steam System Best Practices Condensate System Piping

OPTIMASS 1400 Technical Datasheet

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

AIR CONDITIONING TECHNOLOGY

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

BRAZED PLATE INSTALLATION MANUAL

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

In-Line Electronic Flow Switches

Two-Phase Evaporative Precision Cooling Systems

Control of legionella bacteria in water systems

How To Clean Up A Reactor Water Cleanup

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Wastewater Reuse. Typical treated wastewater is:

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Dew-Point Measurement Solutions

2.12. page Products for Explosion hazardous Environment

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Cooling Towers: Understanding Key Components of Cooling Towers and How to Improve Water Efficiency

Power consumption (kw)

COMBIMASS. Technical Data COMBIMASS eco-bio +

AIR-CONDITIONERS CONDENSATE RECOVERY SYSTEM FOR BUILDINGS

ThermoStar Refrigeration Air Dryers

OPTIMASS 6000 Technical Datasheet

IGEMA BOILER LEVEL & TDS CONTROLS

TABLE OF CONTENT

MC4-50 Feeding System

Benchmark. WASH l RINSE l PASSIVATE l DRY. Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service

IMMERSION MANAGEMENT SERVICE KG

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Heating Water by Direct Steam Injection

REGULATORS 175/153 Series

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

HVAC Processes. Lecture 7

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

Closed Circuit Cooling Towers

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Thermostatic valve Type AVTA

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

MUELLER FALLING FILM CHILLERS

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

VACUUM REFRIGERATION SYSTEMS

TABLE OF CONTENT

ThermoSorb Desiccant Dryers

Technical data. Danfoss DHP-A

presents Hydraulic Separation Beyond Primary / Secondary Piping

4 Posiflow Proportional Solenoid Valves

California Solar Initiative (CSI) Thermal Program Metering Installation Guide

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

Background. 179 million gallons saved for make-up water

How To Understand Evaporator

THE USE OF OZONE IN COOLING TOWERS

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Coriolis Flow meters. Product family introduction Principle of operation Product review Applications Key product features

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

SOLAR-POWERED COOLING, DEHUMIDIFICATION AND AIR CONDITIONING

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

MAC-120HE-01 Air-Cooled Chiller

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

How To Clean Water From An Ammonia Refrigeration System

21.1 Functions, Basic Configuration, and Interfaces

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

Thermal Mass Flow Meters

Ceiling Mount Air Handler Manual

Optimization of Cleaning-In- Place (CIP) processes in bottled water industry

REFRIGERATED COMPRESSED AIR DRYERS

The Different Types of Air Conditioning Equipment for IT Environments

How does solar air conditioning work?

Reliability Accuracy Performance

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Transcription:

Industrial Cooling Systems Cooling Towers, Chillers, Heat Exchangers Flow Meters and Controls Direct Reading Flowmeters For Liquids and Gases

Introduction - Cooling System Basics Today plants face escalating utility cost and tightening EPA control requirement. RCM Industries, Inc. provides direct reading differential pressure flow meters that provide precise flow measurement to manage, maintain and reduce operating cost. The purpose of a cooling system is to transfer heat from the cooling water generated from various industrial equipment and production processes. Cooling systems are composed of a heat exchanger and cooling unit (chiller). The heat exchanger allows cooling water to remove heat from production processes and plant equipment. The cooling unit removes the heat gained from contact with cooling water with hot equipment and fluids in the heat exchanger. The heat is removed by transferring the heat to air through evaporation to the atmosphere thru towers or as a self contained closed loop system. Cooling systems are used in many industrial applications: Petrochemical Pharmaceutical Manufacturing Power Generation Laser Welding Refineries Ethanol / Biodiesel / Gasoline Food and Beverage Automotive Semiconductor Satellite Systems Jetway Preconditioned Air System Evaporation Rate A general rule is for each 10 F circulated water needs to be cooled, 1% of the cooling water is evaporated in the cooling tower. The following equation provides an estimate of the evaporation rate for various circulated cooling water temperature reduction. Evaporation Rate = Recirculated Flow Rate x (Warm Water Temp. Desired Cool Water Temp.) x (1% Evaporation per 10 F Temp. Reduction) Example: If a cooling tower circulates water at a rate of 1,000 gpm and the cooling tower needs to cool the warmed water exiting the heat exchanger from 90 F to 80 F use the following formula to determine the evaporation rate: Evaporation Rate = 1,000 gpm x (90 F - 80 F) x 0.01/10 F = 10 gpm Blow-Down Water The water that drains from the cooling equipment is called the blow-down water. This water has a higher mineral content then potable water algae, bacteria or pathogen may also be present. This makes potable water or treated water using additives to maintain proper ph levels more favorable. Reusing untreated blow down water is not suitable for irrigation of any kind due to high levels of TDS (Total Dissolved Solids).

Make Up Water - Filtration and Treatment Most industrial cooling towers use river water or well water as their source for fresh cooling water called make up water. Make up water is recirculated back to the heat exchanger replacing cooling water lost through evaporation, blowdown and other losses. Adding raw make up water before filtration or treatment can complicate the efficiency and add cost in maintaining the entire cooling system. Any water source has various levels of dissolved or suspended solids that are left behind causing the remaining cooling water to become concentrated. This concentration of solids decreases the efficiency of the cooling system while increasing the chance for a catastrophic failure and damage to critical equipment and production processes. Scaling and Biofouling can also deprive the cooling system from operating properly. Water treatment can reduce the amount of biological growth in the cooling system. Chlorine is the most widely used chemical for controlling biofouling in a cooling system. Chlorine does have its disadvantages in that it reacts with water to form hydrochloric acid and hypochlorous acid causing environmental issues. Chlorine dioxide is a better alternative when treating the water. Chlorine dioxide does not react with water nor does its chemical form or biocidal activity change with changes in ph. Combining corrosion and scaling inhibitors can also improve the water quality and avoid premature fouling. Basic Cooling Tower Schematic Evaporation Control Valves Water Spray Downward Air Air Heat Exchanger Warm Water Flow Meter Make Up Water Air Blown Upward Pump Cool Water Air Preparation Control Valves Reservoir / Well Flow Meter Blowdown Water Control Valves

Point of Use and Modular Chillers Industrial chillers typically come as complete packaged closed-loop systems, including the chiller unit, condenser, and pump station with recirculating pump, expansion valve, flow meter with low-flow alarm, internal cold water tank, and temperature control. The modular design of many chillers provides reliable and economical temperature control. The process fluid being cooled is contained in a "closed" circuit and is not directly exposed to the atmosphere or the recirculated external water. The process fluid that flows through the closed circuit can be water, a glycol mixture or a refrigerant. Industrial chillers are used for controlled cooling of products, mechanisms and factory machinery in a wide range of industries. Chillers provide advanced thermal management solutions in various processes. Above are two Jetway air handling units used to provide cool air flow during pre-flight and loading of the aircraft which dramatically reduces fuel and operating cost. Our Flo-Gage with optional reed switches or transmitter are added to provide an alarm or 4-20mA output when flow rates fall below normal operating conditions then supplied for control room reporting. General Purpose: Electrical Rating: Ambient Temp.: 120 F (50 C) Setability: ± 5% F.S. Hysteresis: ± 13% F.S. Contact Rating: 10 Watts 175 Vdc max. 125 Vac max. Current: 350 ma max. Switching Hazardous Location Approvals: CSA / NRTL/c: AEx ia IIC: Class I, Division I, Groups A, B, C, and D Class II, Division I, Groups E, F, and G KEMA: Ex ia IIC: Zone 0, II 1G T4 0 Ta 50 C ATEX EC Type Examination

Reed switches are an economical solution for equipment protection and automation for critical processes in a variety of industrial and commercial applications. LED s provide viewing at a glance and easy field calibration, LED operating voltage 24Vdc, 20mA. Each switch is independently adjustable from 30% to 90% of full scale. The switches can be configured to your factory set points. Monitoring the cooling system from a remote location can be obtain with the RCM digital display flow meter with optional Modbus communication RS232 / 485 / TTL and backlighting further enhance this models capability. Process control depends on accurate and reliable flow measurement devices strategically placed in key areas along with a careful understanding of the process needs and requirements. Our 7000 series bronze flow meter incorporates an interchangeable orifice which allows the user greater flexibility when to nominal flow rate is not known. In these application a 100% dial is used the flow rate is determined by the orifice used. Each body offer a range of flow rate for that given pipe size. RCM Industries, Inc. provides flow meters to major chiller manufacturers these flow meters come equipped with a stainless steel connection (NPT) 1/4-3 or brass solder connection in 1 1 ½ and 2, and broad range of flow rates to choose from they can be equipped with transmitters with 4-20mA output or dry contact reed switches to monitor flow rate conditions directly or to a remote control room. The chillers (see photo) incorporate 4 RCM flow meters with the reed switch option to monitor low conditions. These switches are factory set to the customer specifications making installation quick and easy.

VAF (Valve and Filter Corp.) Cooling Tower Filtration System Conclusion Designing the optimum cooling system requires a thorough evaluation of the cooling water equipment and cooling system operation primarily the water velocity and water temperature. Low water velocity (flow) causes deposits to form and high temperatures affects water quality requiring treatment to maintain proper ph levels, and minimize biological growth. Many industrial applications utilize both cooling towers and closed loop portable chillers for point of use cooling, flow meters provide proper management of the flow rate of the cooling water optimizing the systems integrity and efficiency and improve manufacturing process yields. With the high cost of fuel, construction, operating and energy, large users of cooling water are forced to maximize thermal and mechanical efficiency. An unrestricted cooling water flow requires careful control of deposit, corrosion, scaling, and biofouling saving thousand of dollars in maintenance and energy cost. Implementing a well maintained management system will provide long term cost saving while saving our environment in excess waste. RCM Industries, Inc. is subject to a comprehensive quality audit from a Notified Body representative once every year meeting ISO 9000 requirements along with quarterly inspections by a CSA representative validating the manufacturing process to meet 94/9/EC directive requirements for hazardous locations. We pride ourselves in providing top quality workmanship in every product we manufacture. Contact the factory our knowledgeable staff is always willing to help in all your flow measurement needs.