For Blue Controllers

Similar documents
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.


LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Prodigy Cuber and Flaker Technical Training

Hoshizaki America, Inc.

APAds Air Conditioning Protection and Control System. Technical Help Frequently Asked Questions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

PANASONIC TROUBLE SHOOTING GUIDE

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Thermo Top - Troubleshooting Tree

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Technical Information

MP-4000 Alarm List (Software version or later)


13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Failure code manual. content

HEAT SIPHON ANSWERBOOK

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Troubleshooting Guide for Dispenser Model #900172

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

CARING FOR YOUR WATER HEATER

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Table Z. Troubleshooting Chart for Air Conditioners. Cause

10.1 Indoor Unit Error Display

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Heat Pump Water Heater IOM Manual

CU50 Service Manual Introduction:

ON-VEHICLE INSPECTION

, User s Manual

Technician High Pressure Pump Guide for the 7.3 Power Stroke Engine

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

All About. Servicing. Service Tech Hand Book Electrolux Home Products Inc David Taylor Drive Charlotte, NC 28262

ECM. Service Guide.

Customized Assessment Blueprint

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

INSTALLATION MANUAL. Address card EKAC10B

SECTION ONE INSTALLATION CONSIDERATIONS

14. Troubleshooting Guide

OPL BASIC. Dosing System for Professional Laundry machines. Contents

USER S MANUAL HSC-24A

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Pro Logic Version Diagnostics Manual

TSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS

*.ppt 11/2/ :48 PM 1

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Compressor Service & Maintenance Manual

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

How To Check A Freezer

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Nexus FS Point of Use Installation Guide

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Haier Air conditioner

Odyssey of the Mind Technology Fair. Simple Electronics

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Portable Air Conditioner

Oil and Coolant Circulating Heating System. Model - OCSM

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Electronically Controlled Clutchless or Variable Drive Compressors

HEAT PUMP PROGRAMMABLE THERMOSTAT

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Alfa Romeo 147 On board instruments installation guide

Service Manual. Service Manual. F200 & F300 Modular Ice Cuber & FMIC 180 & 260 Electronic Modular Ice Cuber

MicroTech III Unit Controller for Water Source Heat Pump Units

Aqua Rite & Aqua Rite XL Diagnostics Manual

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

QPCD QPCD-100 Parts List 115 Volt / 1 Phase / 60 Hz / R-134A REFRIGERANT COMPRESSOR, 0.75HP, R-134A DRAIN VALVE, 2-WAY SOLENOID VALVE, 0.

Owner s Manual Phoenix 300

Hoshizaki America, Inc.

SCE170. Introduction. Table of Contents

Commercial Refrigeration Temperature and Defrost Controls

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

MDT5N25 & MTD5N40 SERVICE PARTS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

A/C-HEATER SYSTEM - AUTOMATIC

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

AVR Pellet Control Board Installation/Service Instructions

Instruction manual for Firstline FCS12000CH

MicroTech III Unit Controller for Water Source Heat Pump Units

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Transcription:

CM 3 CONTROL SYSTEM CHECK OUT PROCEDURE For Blue Controllers All readings should be a Yes. If they are, there is NOTHING WRONG with the control system. Start with a clean machine. Be sure voltage is correct, check both active and idle voltage. Be sure all electrical components have good connections. Record any existing diagnostic light codes here. Last: 2 nd from last: Diagnostic codes indicate machine problems, not controller faults. See potential causes for codes at the end of this check out procedure. Step 1: Check EEPROM code. Push and hold the off button till the unit shuts off. Unplug the connection at number 8 and reconnect it. Check lights. All lights blink on and then off. Both red lights blink for 20 seconds. While the red lights are blinking, check which green lights, if any, are on. Compare to chart on ice machine or to table on page 8. Correct code? After 20 seconds, bin full light and off light are on for 5 seconds. At the end of the power up process, only the off light is on, unless the bin is full or the thermostat is closed. If all the green lights are on AND the bin full light is flashing, the controller needs to be replaced. If no lights come on, check the power to the controller. If the voltage is correct, replace the controller. May be a black controller, if it is, this check out procedure does not apply. Blue controllers have a Control Products sticker on an edge. If the green light code is wrong, and the controller was a replacement, check the selector switch position. If the code is wrong with an original equipment controller, replace it. Continue with check out. If the bin full light stays on, check the thermostat or the ice sensors.

Step 2: Check water level sensor. Check out procedure must not be done in direct light. Wire colors match between sensor and controller. Same color on top of each? Confirm float stem. Check by color and part number. Correct? Check if unit is level. Check standpipe (where used) at correct setting. Use DC voltmeter. Unplug harness. Check voltage at controller top and bottom pins of number 2: List here: Between.2 and 5 volts DC? Reconnect harness. Recheck voltage. List Here: Is it between.4 and 2? Connect negative probe on bottom terminal. Put positive probe on the one above. Note reading. Move float up and down all the way and note changes. Is the voltage when the stick is all the way down very near to 5? Is the voltage when the float has the slot in the sensor less than 5? Should be about 4.5. Connect positive probe to next higher terminal. Repeat process. Are the results the same? Correct wire harness connections Install correct float stem Level unit Adjust standpipe Check power supply to controller. If that is OK (between 22 and 27 VAC) replace the controller. Replace sensor Replace sensor Replace sensor Replace sensor 2

Step 3: Check temperature sensor calibration Indicator lights on controller, are both red lights off? Measure sump water temperature. Record here. Measure resistance of water sensor. Record here. Compare to chart. Reading within 2 o F of correct temperature? Measure discharge line temperature. Record here. Measure resistance of discharge sensor. Record here. Compare to chart. Reading within 3 o F of correct temperature? Check to see if temperature sensors are plugged in, if they are and the machine is switched off, replace the sensors. If the machine is operating, let it finish the cycle to determine if the indicator lights change. If when the machine shuts off both lights are still on, change the sensors. Change sensor Change sensor Step 4: Check ice sensor operation Ability to sense ice. Disconnect thermostat if used. Drop 10 20 cubes in a bunch onto the ice deflector so they slide into the bin. Did the bin full light blink? If no ice, hold something in between ice sensors in ice drop zone. Bin full light should blink or glow unblinking. Recheck above with clean sensors Bin full light. With the bin thermostat disconnected and the ice level low, is the bin full light off? Unplug terminal 4. Bin full light should come on. If not, replace controller. If OK, clean sensors and recheck. Replace sensors Check sensors for mineral scale build up. Clean as required and retest. If the bin full light is always on with clean sensors and no thermostat, replace the sensors. 3

Assuming the control system checks out, the operation of the machine can be checked. This procedure follows the normal operational sequence of a self contained model that is not full of ice. Step 4: Overall Machine Operation From Off, push freeze to start the machine. If the sump is empty overflow drain models begin to fill the reservoir, while purge valve models open the purge valve, drain water and then fill the reservoir. Does the inlet water valve open and fill the sump? Does the water pump start? Check voltage at inlet water valve coil. If roughly 24 volts, check coil for continuity. If coil is open, replace valve. Recheck float stick. Check water pressure. Check for voltage at controller water valve pins. If no voltage, replace controller. If voltage is at controller but not valve, check/replace harness. Check voltage to the pump. If normal, check the pump motor for continuity or the impellor for a foreign object or binding. Remove any foreign object. Replace if motor is open or impellor stuck. If no power at pump, check voltage at controller pump pins. If none and there are no water diagnostic lights on, replace controller. If there is a two-blink water diagnostic indicator, the water sensor did not sense a full sump of water. See water sensor. 4

The freeze light is now on continuously. Does the compressor start? If the unit is air cooled does the fan motor start? Does the sump water temperature begin to fall? Does the pump stop for 30 seconds within the first 5 minutes of the freeze cycle? Are cubes forming at about the same speed on all evaporator plates? When the cubes are full sized, does the unit go into a harvest cycle? Check contactor for voltage to it. If none, check for voltage at controller contactor pins. If none, replace controller. If there was voltage, check contactor coil. If contactor closes and compressor does not start, check starting components. Check voltage at compressor. Check windings, go through normal compressor check out procedure. Check voltage at fan motor. If correct, change fan motor. If none, check voltage at controller fan motor pins, if none, replace controller. If voltage is correct at controller but not fan motor, change high voltage harness. Check refrigeration system Sump temperature is not falling to anti-slush point. Check for inlet water valve leak through or lack of refrigeration effect. Check refrigeration system Check for light shining on the water level sensor or an inlet water valve leaking through 5

When the unit goes into the harvest cycle, does the hot gas valve open fully? A partially open hot gas valve results in lower than expected suction pressure in harvest, and a slow harvest. Do the fan and water pump stop during the harvest cycle? As ice is harvested, does the bin full light blink? Does all the ice release from the evaporators during the first harvest cycle? On purge valve models, does the purge valve open? As ice is harvested, does the water inlet valve refill (overflow models) or partially refill (purge valve models) the sump? Check bin thermostat operation by connecting the leads at the thermostat together. Unit should shut down at the end of the harvest cycle. Simulate bin full by removing the sensor wire from terminal 4 on the controller. Does the unit shut down at the end of harvest? Check for loose connection to hot gas valve coil, check voltage at coil. If roughly 24, check coil for continuity, replace coil if open. If no power to coil when harvest light is on, check for power at controller hot gas valve pins. If none, replace controller. If there is power, replace harness between controller and hot gas valve. Pump will restart, self contained fan stays off, if not, replace controller. Repeat ice sensor test. Check for mineral scale on the evaporators or an external environmental cause. Check voltage at purge valve coil, if line voltage, check coil for continuity and valve flap for binding. Replace as needed. If no voltage, check purge valve timer for input voltage. If it has input voltage and no output voltage, change purge valve timer. Check position of the float stem, if all the way down water valve may not refill. Check harness to controller. Check for jumper on low voltage harness, if not a remote there should be no jumper between #6 and #7. 6

Diagnostic Code Causes: Water Section: Indicator Light: Blinks once and repeats Blinks two times and repeats Is ON without blinking Both on without blinking Refrigeration Section: Indicator Light Blinks once and repeats Blinks two times and repeats Blinks three times and repeats Is on without blinking Possible Cause Water level not falling, pump failure or hose off, or unit not level, or standpipe height incorrect Water level not rising fast enough. Lack of water supply, filters restricted, low pressure, standpipe height incorrect, purge valve leaks thru, water leaks out of sump. Water level rises at wrong time, water valve may be leaking through Temperature sensor set unplugged or failed. Possible Cause Maximum harvest time limit. Slow ice release during harvest, ice sensors working Maximum harvest time limit. No ice release or ice sensors not working. High discharge temperature Two potential related causes. 1. Maximum freeze time limit reached. This is typically caused by a condensing unit failure lack of refrigeration effect. Check cycle time. 2. Low discharge temperature. If it s known that the unit shut off early in the freeze cycle and this diagnostic is on, the controller diagnosed a lack of refrigeration early in the cycle. Check cycle time. 7

Controller Connection Reference Contactor Coil 24v Power 24v Power Hot Gas Valve Inlet Water Solenoid Pump Line In Line In Fan Motor or Liquid line valve or Harvest bypass valve EEPROM Table Code = Green Lights On None Clean Harvest Clean and Harvest Freeze Freeze and Clean Freeze and Harvest Freeze, Harvest and Clean Bin Full Bin Full and Clean Bin Full and Harvest Bin Full, Harvest and Clean Bin Full and Freeze Bin Full, Freeze and Clean Bin Full, Freeze and Harvest = Controller Programmed for Model CME256, CME506, CME656 CME806 CME1056A, CME1056R CME1056W CME1356, CME1656 CME1856, CME2006 CME306 CME456 SCE275 European Model CM450SL CME810 CME686 CME1386 CME1686 CME2086 Controller Connections 8 9 7 6 5 4 3 2 1 PUSH BUTTON CONTROL SWITCHES INDICATOR LIGHTS: BIN FULL FREEZE HARVEST CLEAN OFF ERROR LIGHTS: WATER REFRIGERATION 291-827 8