CommScope Intelligent Building Infrastructure Solutions (IBIS)

Similar documents
Honeywell Controls Enterprise Buildings Integrator System Over CommScope Cabling

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

CommScope Intelligent Building Infrastructure Solutions (IBIS)

Technical Description U00980 Revision 2

Local-Area Network -LAN

Network Design. Yiannos Mylonas

A network is a group of devices (Nodes) connected by media links. A node can be a computer, printer or any other device capable of sending and

Data Center Topology Guide

Upgrading Path to High Speed Fiber Optic Networks

What You Will Learn About. Computers Are Your Future. Chapter 8. Networks: Communicating and Sharing Resources. Network Fundamentals

InstaPATCH Cu Cabling Solutions for Data Centers

UniFireNet Facilities Monitoring System MEA GENERAL NETWORK FEATURES

Understanding Device Level Connection Topologies

Obsolete Fiber Technology? Not in my Data Center!

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

Planning BACnet networks

How To Create An Intelligent Infrastructure Solution

Local Area Network. OSI Seven Layer Model. Whole Building Network

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

Optimizing Infrastructure Support For Storage Area Networks

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

Overview of Routing between Virtual LANs

AMP NETCONNECT Data Center Cabling Solutions

Using installed Fieldbus Wiring to carry Ethernet Communications

System Development and Life-Cycle Management (SDLCM) Methodology

SYSTIMAX Copper Solutions Designed for the Digital Generation

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Ethernet. Ethernet Frame Structure. Ethernet Frame Structure (more) Ethernet: uses CSMA/CD

Network Structure or Topology

Chapter 15: Distributed Structures. Topology

Data Center Design Considerations

Computer Networks. By Hardeep Singh

Wireless LAN Concepts

Cabling LANs and WANs

Lecture 6 Types of Computer Networks and their Topologies Three important groups of computer networks: LAN, MAN, WAN

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Introduction to Ethernet

Evacuation Lighting Management System

Networks. The two main network types are: Peer networks

Advanced Transportation Management Systems

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Understanding Device Level Connection Topologies

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

WAN Data Link Protocols

Communication Networks. MAP-TELE 2011/12 José Ruela

DCM. Product Brochure. Diagnostic Communication Master

Data Communication and Computer Network

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Computer Network and Communication

Tutorial.

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

Structured and Point to Point Network Cabling for Industrial Automation

imvision System Manager

Design Guide. SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines. June 2015

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

RS485 & RS422 Basics

Industrial Networks & Databases

Power Separation Guidelines for SYSTIMAX Installations

LONWORKS 78kbps Self-Healing Ring Architecture

Introduction to the LonWorks Platform. revision 2

1 Which network type is a specifically designed configuration of computers and other devices located within a confined area? A Peer-to-peer network

GigaSPEED X10D Solution How

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

CN1047 INTRODUCTION TO COMPUTER NETWORKING CHAPTER 1 BASIC CONCEPTS OF NETWORK

CHAPTER 6 DESIGNING A NETWORK TOPOLOGY

Introduction to the LONWORKS System

ZigBee Technology Overview

Figure 1 FPGA Growth and Usage Trends

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

CHAPTER 6 NETWORK DESIGN

SAN Conceptual and Design Basics

Integrated Building Management and Security System. Building Automation & Security.

Layer 3 Network + Dedicated Internet Connectivity

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Using High Availability Technologies Lesson 12

Network configuration for the IBM PureFlex System

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

11/22/

Linear Motion and Assembly Technologies Pneumatics Service. Industrial Ethernet: The key advantages of SERCOS III

SEAGATE SOFTWARE. About Seagate Software. IBDN Success Stories Technology. Currently, Seagate Software has customers in more than 75 countries

Acceptable Use Policy (AUP): Policy which provides rules governing use of district technology.

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Living Infrastructure

L2F Case Study Overview

Comm5 Wiring Installation

Parking Guidance System

Setting Up and Testing the MAX Hardware

Network Topologies and Distances

Networking Devices. Lesson 6

Redundancy in enterprise storage networks using dual-domain SAS configurations

Category 5 Outside Plant

Transcription:

SYSTIMAX Solutions CommScope Intelligent Building Infrastructure Solutions (IBIS) LonWorks Design Guide September 2007 www.commscope.com

Contents 1.0 Introduction 3 2.0 LonWorks TECHNOLOGY 4 2.1 Transceiver 4 2.2 Repeaters and Routers 5 3.0 LonWorks and SYSTIMAX Configurations 7 3.1 Building Control System Topologies 7 3.1.1 Centralized and Distributed s 7 3.1.2 Single-Floor Layout 8 3.1.3 Distributed Star Topology 9 3.2 FT-10A Cabling Topologies & Parameters 10 3.2.1 Point-to-Point Wiring and Daisy Chaining 10 3.2.2 Star Wiring 11 3.2.2.1 Chained Branches 12 3.2.2.2 Bridged (Multipoint Bus) Branches 13 3.2.3 Remote Star Wiring 14 3.3 Shared Sheath Configuration 14 www.commscope.com 2

1.0 Introduction CommScope Intelligent Building Infrastructure Solutions (IBIS) is a modular, flexible cabling infrastructure system that supports voice, data, video and building automation system (BAS) by providing a robust and cost effective connectivity for all of a building s BAS and communication systems. IBIS utilizes twisted pair and/or fibre optic cables to provide connectivity in an open architecture environment. CommScope IBIS supports cabling for the installation of LonWorks technology based systems using various SYSTIMAX PowerSUM, GigaSPEED XL or GigaSPEED X10D solutions. The purpose of this guide is to help customers identify and implement CommScope IBIS connectivity solutions for systems based on LonWorks Technology. LonWorks Technology offers manufacturers a solution to designing, building, installing, and maintaining control networks. This technology is based on a peer-to-peer architecture and needs no central controller because intelligent nodes (control devices) communicate directly with each other. Each node has the intelligence to perform control functions and can communicate with other nodes using the LonTalk protocol. These nodes can be linked together to implement applications in consumer electronics, factory automation, commercial building automation, home automation, vehicle controls, etc. Contact an Echelon Representative for further information. LonWorks technology provides the components and tools required to design applications that distribute intelligence and control throughout a system. A central component in the LonWorks product family is the Neuron Chip, which contains the LonTalk protocol stack and a dedicated applications processor. When nodes are required to communicate over long distances, transceivers are used. The LonWorks Transceiver is a free topology device that provides a physical communication interface between a Neuron Chip and a LonWorks twisted pair network. The is used to implement node-to-node communication, and may also be used as elements of repeaters and routers to extend networks. A number of cabling arrangements in support of LonWorks systems are possible and should be considered in relation to the various applications that customers plan to use. For these different applications and cabling configurations, there are signal loss budgets and other performance issues for signaling. The number of devices placed on a link or bus, and the cabling distances supported, are determined according to the electrical characteristics of the cable and of the different types of applications and configurations. Because of the many aspects that must be considered, an Application Guide is desirable to help our customers identify and implement various connectivity solutions. This document contains information and instructions for the installation of LonWorks communication channels. Systems employing the transceiver will usually have interfaces to endpoint devices (that is, temperature sensors, dampers, etc.). This guide does not cover endpoint devices. Contact your CommScope and/or your LonWorks representative to determine the support for endpoint devices. www.commscope.com 3

2.0 LonWorks TECHNOLOGY LonWorks is a set of components and tools that are used to implement distributed intelligence and control functions into products. The components consist of: 1. A Local operating network 2. LonTalk Protocol 3. Neuron Chip Family, and 4. LonWorks Transceivers A network of intelligent nodes are connected together by communication media (for example, SYSTIMAX x061/x071/x081/x091 cable) and communicate with each other using the LonTalk Protocol. The Neuron Chips are the processors in the intelligent nodes. These chips process the LonTalk Protocol, provide I/O monitor/control, execute application-specific (for example, Temperature Control and setback) functions and provide memory for the application. LonWorks Transceivers encode and decode the transmitted and received data for transmission over long distances. The LonWorks Transceiver supported by CommScope IBIS is the. 2.1 Transceiver The Free Topology Twisted Pair transceiver supports star, bus, and loop wiring architectures. The transceiver uses transformer isolation and 78 kbps differential Manchester coded data signals. Nodes equipped with the communicate via a twisted-pair cabling channel. The cabling channel may be comprised of multiple segments separated by physical layer repeaters. The transceiver may be used as an element of a physical layer repeater or router to extend the number of nodes and distances of the network. A free topology architecture has no topology restrictions. CommScope IBIS employs the free topology capability in a modified star structured cabling system. The following sections illustrate SYSTIMAX configurations. The channel segment parameters are listed in Table 1. Table 1: LonWorks Parameters LonWorks Free Topology Transceiver Transceiver Rate (Kbps) Topology Nodes/ Segment x061/x071/x081/x091 (m) Maximum node-to-node distance (m) 78 Bus (Note 1) 64 500 (900 m electrical length) 78 Free (Note 2) 64 450 250 Note 1: Doubly terminated Bus; 3 meter stubs, SYSTIMAX implements this as star wiring with chained branches. Note 2: Requires one termination; SYSTIMAX implements this as star wiring with bridged branches. www.commscope.com 4

2.2 Repeaters and Routers The repeater function may be implemented as an N-way repeater as shown in Figure 1. The repeaters in Figure 1 have multiplicity of 2 (2-way) and 4 (4-way). Each port of the repeater connects to a different channel segment. Each segment is implemented as described for CommScope IBIS in this guide. Only one repeater may be used per channel, but there is no limit on the multiplicity of the repeater (that is, the value of N is not limited). However, traffic engineering should be performed to ensure network performance criteria are met. When there are high levels of traffic, LonWorks routers may be used to meet performance criteria. When networks are partitioned, routers will forward messages to other channels as necessary. Figure 1: Repeater Examples 2-way repeater 4-way repeater A LonWorks router is used to cascade different channels (single or multiple segment channels). There is no limit on the number of cascaded routers, but performance criteria and traffic engineering will control the number of cascaded routers. Repeater and router parameters are summarized in Table 2.The router and/or repeater will count as a single node towards the maximum nodes per channel segment. The repeater is connected to the end of a network channel segment and extends the total distance and node count of the network. The router may be connected at any point on the network channel segment. Table 2: LonWorks Repeater/Router Parameters LonWorks Repeater and Router Parameters for LONs Device Name Max. Number of Max. Number Distance Maximum Nodes Repeaters with of Routers per Segment with per Segment Multiplicity N Repeater or Router Repeater 1 N/A See Table 1 See Table 1 Router N/A unlimited See Table 1 See Table 1 www.commscope.com 5

When the number of nodes (intelligent nodes/controllers) is small, the distribution of nodes within a network will be determined mainly by logical groups (for example, lighting control, access control), physical considerations (for example, location of entrances, size and location of class rooms, etc.), the number of endpoint devices (for example, card readers, lights, temperature sensors, motion sensors, etc.), and the location of the main workstation (if a main workstation is present). As the number of nodes grows, factors such as the traffic load, performance, availability, capacity, and network management and expandability will increase in importance. The topology selected will depend on the traffic flow and the physical layout of the channel segments to be joined together. Typical network topologies are shown in Figure 2 (a through c). Passive loops on any free topology segment are permitted to increase system availability in the event of a cable break. Figure 2: Typical LonWorks Network Topologies (a c) Segment 1 2-way Repeater Segment 2 Figure 2 (a): The Simple Repeater Connection one channel of two segments Segment 3 Segment 1 4-way Repeater Segment 2 Figure 2 (b): Multiple Segments Connected to a Repeater one channel of four segments Segment 4 Channel 1 Segment 1 Channel 3 Segment 1 2-way Repeater Channel 3 Segment 3 Router 2 Router 3 Router 1 Channel 2 Segment 1 2-way Repeater Channel 2 Segment 2 Channel 4 Segment 1 Figure 2 (c): Multiple Repeaters and Multiple Routers www.commscope.com 6

3.0 LonWorks and SYSTIMAX Configurations LonWorks technology is designed into many network solutions including industrial and commercial applications (for example, power monitoring, utility metering, process control, etc.), and Building Automation Systems (BAS) such as EMS, HVAC, Fire & Life Safety, Security and Access Systems. The CommScope IBIS connectivity concepts employed to implement these solutions are described in this guide. 3.1 Building Control System Topologies The workstations, controllers, repeaters, and devices of LonWorks systems are configured using bus and star topologies, and CommScope IBIS. The IBIS design for many building types are facilitated by the use of point-to-point, daisy-chain bus, star, and distributed star configurations. The following LonWorks systems and IBIS topologies are examples of using these design concepts. 3.1.1 Centralized and Distributed s In Figure 3, a workstation communicates through a gateway to a server on an Ethernet 10BASE-T LAN connection. The workstation software enables a user (single or multiple) to manage buildings (for example, load programs, scheduling, alarm resolution, reports, etc.). The workstation may operate directly on the bus (requires a interface for the PC) and/or it can communicate with remote sites in a wide-area network (WAN) over telephone lines. The workstation centralizes the management of network controllers. The workstation and controllers are the focal points for the BAS and (when possible) are centralized in the Building Distributor (BD) (also referred to as Entrance Facility (EF) or Equipment Room (ER)). The preferred location for the controllers is the BD in Figure 3. Their endpoint devices (sensors and actuators) are connected to horizontal wiring via the blue field as point-to-point wiring (singe device or daisy-chained devices). Devices on other floors are connected through the Backbone wiring to the blue field of the other floors. When the number of controllers required are distributed throughout the building at distances that prohibit localization in the BD, they are distributed in the Floor Distributors (FDs) (also referred to as Telecommunication Rooms (TRs)) and the horizontal subsystem. A sequence of daisy-chained controllers in the horizontal is referred to as a branch. To provide the proper device density on a floor, more than one branch may be required. Each branch will usually have a number of controllers on the bus. The administration subsystem (white, blue, and purple fields of the cross-connect) is used to bridge branches and or chain (that is, serially connect) the branches together. www.commscope.com 7

3.1.2 Single-Floor Layout An example of a single-floor layout is shown in Figure 3. The primary controller placement strategy is to centralize the controllers (including workstations if applicable) in the BD (see Figure 3, workstation, controller, gateway, etc.). The factors determining the device(s) density for the floor include the type of device, the type of building (for example, office) and/or the building owner and/or codes. For example, each office (size 100 sq. ft or 9 sq. m) and each conference room (size 600 sq. ft or 54 sq. m) may require one thermostat and one variable volume/variable temperature (VVT) controller. The horizontal cabling is routed via the distribution method (for example, raceways, building support members, etc.) from the devices to the controller(s) in the BD. Figure 3: Example of Single-Floor Layout Coverage Area Coverage Area Coverage Area Horizontal Distribution Horizontal Distribution Building Distributor (BD) Gateway PC Workstation branches bridged or chained in the BD Keys: Information Outlet (IO) Device Patch Panel System Centralization of controllers is recommended in implementing device densities and wiring. However, when this is not possible, controllers ( that is, intelligent nodes) are installed in the coverage area for the device (for example, temperature sensors, dampers, etc.) it operates. Three controller branches are shown in Figure 3: (1) at left 3 chained nodes, (2) in the center 4 chained nodes; (3) at right two chained nodes. The workstation is connected to the bus by the patch panel. Branches one, two and three are administered (as chained branches or bridged branches) in the BD. www.commscope.com 8

3.1.3 Distributed Star Topology An example of distributed star topology using repeaters and routers is shown in Figure 4. When there are multiple floors and each floor has a large number of controllers, the star topology is a convenient way to centralize control of the BAS. The bus is routed through the backbone cabling and each FD has controllers that support endpoint devices and other controllers on its floor. There is a star wiring configuration administered by the patch panel in the FD on each floor. If the channel segment distance and node count are at the maximum, repeaters are added in the FD to extend the capacity of the network. This is illustrated in Figure 4 at FD1, where the coverage area or number of nodes on the floor requires more than one segment. When network capacity is reached (for example, due to traffic engineering, network partitioning, etc.), routers are used to communicate between two networks. Routers may be placed in any of the IBIS subsystems (BD, FD, campus, etc.) and count as a node on each of the channel segments it connects. See Figure 4 example. Figure 4: Example of Distributed s and Repeaters Coverage Area Coverage Area Router FD4 Router Coverage Area FD3 Riser Backbone Distribution Router Repeater Coverage Area FD2 Coverage Area FD1 Gateway PC Workstation BD Keys: Information Outlet (IO) Device Patch Panel System www.commscope.com 9

3.2 FT-10A Cabling Topologies & Parameters 3.2.1 Point-to-Point Wiring and Daisy Chaining Basic point-to-point wiring is illustrated in Figure 5. The recommendation for maximum horizontal distance (from cross-connect to the IO) is 90 meters. The point-to-point wiring may include a daisy chain of devices in the coverage area. This is illustrated in Figure 6. Figure 5: Point-to-Point Wiring of Devices Floor Distributor Figure 6: Point-to-Point Wiring and Daisy Chaining of Devices Floor Distributor Keys: Information Outlet (IO) Device Patch Panel System www.commscope.com 10

3.2.2 Star Wiring Basic star wiring is illustrated in Figure 7. The branches may have a single device or a chain of devices. There are two methods of forming a physical star cabling configuration. The first method is to bridge the branches together at the cross connect in the FD/TR (This is referred to as Chained Device connections in the CommScope IBIS General Design Guidelines for BAS documentation or Multipoint Bus in TIA/EIA-862). This is illustrated in Figure 8. The second method is to chain the branches in the FD/TR on the cross connect. In this method, each branch is serially connected to the other branches to form a bus (This is referred to as Chained Branches in the CommScope IBIS General Design Guidelines for BAS documentation or Chained Connections in TIA/EIA-862). This is illustrated in Figure 9. Figure 7: Basic Star Wiring Configuration Branches are either chained or bridged together in the FD on the cross-connect Branch 1 Branch N (N = 10 max) Floor Distributor (FD) Figure 8: Bridged or Multipoint Bus Configuration Trunk Devices Branch 1 Branch Length Bridged or Multipoint Bus Connections Branch N (N = 10 max) Keys: Information Outlet (IO) Device Patch Pan www.commscope.com 11

Figure 9: Chained Branches (Chained Connections) Configuration Trunk 4-Pair Cable Cable Pairs Branch 1 Chained Connections Branch N (N = 10 max) Branch Length 3.2.2.1 Chained Branches The following requirements must be applied to chained branch circuits: 1. 2. 3. 4. 5. 6. Doubly terminated bus. Total maximum cabling distance = 500 m (1640 ft) of 4-pair SYSTIMAX PowerSUM / GSXL/GSX10D cabling. This is equivalent to 900 m (2953 ft) of electrical length. The implementation of chained branches requires two pairs per 4-pair cable except for the last branch). Maximum number of 100 m (328 ft) branches = 5. Maximum number of devices = 64. Maximum node-to-node distance = 500 m (1640 ft). This is equivalent to 900 m (2953 ft) of electrical length. Minimum node-to-node distance = 0 m (0 ft). www.commscope.com 12

The maximum length bus runs from the FD/TR cross-connect, where it is terminated, down pair 1 of the first branch cabling, loops back at the branch end and runs back up pair 2 in the same branch cabling to the FD/TR. Pair 2 of the first branch cabling is connected to pair 1 of the second branch cabling. The bus continues similarly down pair 1 of the second branch cabling and back on pair 2. This continues for the third, and fourth branch cabling, and finally runs down pair 1 of the fifth branch cabling, where it is terminated at the end. This creates a doubly-terminated bus with an electrical length of 900 meters on five 100 meter cabling branches. This is illustrated in Figure 10. Note: The electrical length of each of the first four cabling is the length of pair 1 plus the length of pair 2. Since only one pair is used in the fifth branch, its electrical length is the length of pair 1. Figure 10: Chained Branches Configuration From Purple Field (Equipment Field) Yellow Field (Bridging Field) Blue Field (Horizontal Field) Branch 1 Branch 5 To Devices 3.2.2.2 Bridged (Multipoint Bus) Branches The following requirements must be applied to bridged branch circuits: 1. 2. 3. 4. 5. 6. Singly terminated bus. Total maximum cabling distance = 450 m (1476 ft) Maximum number of 100 m (328 ft) branches = 4 Maximum number of devices = 64 Maximum node-to-node distance = 250 m (820 ft) Minimum node-to-node distance = 0 m (0 ft) www.commscope.com 13

3.2.3 Remote Star Wiring The remote star wiring is the same as the star except that the controller is placed on a different floor or a location different than the FD/TR. This topology provides two points of administration: one administration in the BD/ER and one point of administration in the FD/TR. This allows greater flexibility in port assignment for changes and future technology upgrades. The trunk distance must be considered in the overall cabling distance. See Figure 11. The rules for remote star wiring are the same as the star wiring with the following exceptions: 1. 2. 3. The length of the bridge trunk (see Figure 11) is subtracted from the total cabling length and the remaining cabling length is used to implement the chained branches. If the bridge trunk length is less than a single branch length maximum (that is, 100 m [328 ft]), then the total branch count is the same as the star configuration but the last branch length is shorter by the trunk length. If the trunk length is equal to or greater than a maximum branch length, the number of branches are reduced accordingly. 3.3 Shared Sheath Configuration The signal of a communications bus shares a cable with itself. In the implementation of chained branches, signals share the same sheath. The bus can share the same sheath as 10BASE-T and 100BASE-T signals. Figure 11: Remote Star Wiring Configuration Branches are either chained or bridged together in the FD on the cross-connect Branch 1 Riser Backbone Distribution Bridged Trunk Branch N (N = 10 max) Floor Distributor (FD) Building Distributor (BD) Information Outlet (IO) Patch Panel System Keys: www.commscope.com Device Visit our Web site or contact your local CommScope representative for more information. 2011 CommScope, Inc. All rights reserved. All trademarks identified by or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. MI-99 10/11