DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Similar documents
DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ICC-ES Evaluation Report

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Hilti, Inc South 122 nd East Avenue Tulsa, OK

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

CITY OF LOS ANGELES CALIFORNIA

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Fastener Loads for Plywood Screws Number E830D August 2005

LP OSB Sheathing & Structural 1 Sheathing

Featuring TJ Rim Board and TimberStrand LSL

Submittal Information

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Discipline: Structural Issued

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

CITY OF LOS ANGELES CALIFORNIA

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

CITY OF LOS ANGELES CALIFORNIA

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Screw Thread Design. Rev

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

ATI Evaluation Service A Division of Architectural Testing Certification Services

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

Residential Deck Safety, Construction, and Repair

Typical Deck Details

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

HUS-HR, CR Screw anchor, stainless steel

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Chapter 6 ROOF-CEILING SYSTEMS

RPS - sales@rpssolar.com San Bruno Cove, San Diego, CA 92130

SECTION GUARDRAILS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

Metal Roofing Practical Design

Connection Solutions

Uncovered Decks & Porches

Guidelines for Earthquake Bracing Residential Water Heaters

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

Residential Decks. Planning and Development Services Department

6 RETROFITTING POST & PIER HOUSES

Detailing of Reinforcment in Concrete Structures

Seismic Installation for Attic Storage System

POST AND FRAME STRUCTURES (Pole Barns)

Guidelines for Earthquake Bracing of Residential Water Heaters

European Technical Approval ETA-12/0500

Regional and Site Assumptions This document is based on the following regional and site assumptions:

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Fire-Retardant-Treated (FRT) Plywood

RAIL FREE SOLAR ROOF MOUNT

CHAPTER 7. Connections. 7.1 General. The objectives of connection design are

Manufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Specification for Rotary Drill Stem Elements

PART 1 GENERAL 1.1 SECTION INCLUDES

European Technical Assessment ETA-10/0153 of 10/06/2015

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

HVU with HAS/HAS-E rod adhesive anchor

Assembly Instructions

Concrete Design Manual

Owner's Manual & Assembly Instructions

European Technical Approval ETA-11/0024

Seismic Technical Guide

PC-Concrete Injectable Concrete Anchoring and Repair System

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

WAVELET WATER QUALITY MONITORING KIT

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

COMMONLY USED RESIDENTIAL BUILDING CODES

Reproduced with the permission of the American Welding Society (AWS), Miami, Florida - 09/15/ Stud Welding

Transcription:

0 ICC ES Report ICC ES (800) 43 6587 (56) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 353 Reissued 04/05 This report is subject to renewal 04/07. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 3 WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. 0 WEST MAIN STREET COURT ALPINE, UTAH 84004 EVALUATION SUBJECT: GRABBER LAG MASTER AND TIE MASTER MULTI PURPOSE WOOD FASTENERS Look for the trusted marks of Conformity! 04 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 06 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-353 Reissued April 05 Corrected February 06 This report is subject to renewal April 07. www.icc-es.org (800) 43-6587 (56) 699-0543 A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 3 Wood, Plastic, and Composite Fastenings REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. 0 WEST MAIN STREET COURT ALPINE, UTAH 84004 (95) 680-0777 www.grabberman.com EVALUATION SUBJECT: GRABBER LAG-MASTER AND TIE-MASTER MULTI- PURPOSE WOOD FASTENERS.0 EVALUATION SCOPE Compliance with the following codes: 05, 0, 009 and 006 International Building Code (IBC) 05, 0, 009 and 006 International Residential Code (IRC) 03 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 009 IBC. 009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Structural Corrosion resistance.0 USES The Grabber Lag-Master and Tie-Master Multipurpose Wood Fasteners described in this report are used in engineered wood-to-wood connections in accordance with the IBC and the ANSI/AWC National Design Specification (NDS) for Wood Construction. The fasteners may be used under the IRC when an engineered design is submitted in accordance with IRC Section R30..3. 3.0 DESCRIPTION 3. General: The Grabber Lag-Master and Tie-Master Multipurpose Wood Fasteners are proprietary, partially threaded dowel-type fasteners. The threads are formed by rolling and have a pitch of 0 threads-per-inch. See Table for designations and dimensions and Figure for depictions of the fasteners. The fasteners are available in boxes of loose fasteners. 3.. Lag Master : Lag-Master fasteners have 3 / 8 -inch (9.5 mm) hex washer style heads and are available in lengths ranging from 7 / 8 to 5 7 / 8 inches (73 to 49 mm). 3.. Tie Master : Tie-Master fasteners have countersunk heads with a Torx T40 recess and are available in lengths ranging from 4 to 0 inches (0 to 54 mm). 3. Material: 3.. Lag Master and Tie-Master Fasteners: The Lag-Master and Tie-Master fasteners are manufactured from carbon steel wire complying with ASTM A50, Grades 0B8 through 0B, and are heat-treated to achieve case and core hardness in accordance with the manufacturer s specifications. The fasteners are mechanically galvanized in accordance with ASTM B695 Class 55. 3.. Wood Members: Wood members must be solidsawn lumber having an assigned specific gravity, as specified in Table.3.3A of NDS-5 (Table.3.3.A of NDS- for the 0 IBC, Table.3.A of NDS-05 for the 009 and 006 IBC) of 0.50 or greater. The thickness of the wood main member, t m, must be equal to or greater than the screw length less the thickness of the side member, t s. For the purposes of resisting lateral loads, the side member must have a minimum thickness, t s, as specified in Table 3. For the purposes of resisting pullthrough loads, the side member must have a minimum thickness, t s, of 3 / 4 inch (9. mm). 4.0 DESIGN AND INSTALLATION 4. Design: 4.. General: The Grabber Lag-Master and Tie- Master Multi-purpose Wood Fasteners are intended for use with sawn lumber. The Lag-Master fasteners are used with side members with thickness ranging from / to 4 / 4 inches (38 to 08 mm). The Tie-Master fasteners are used with side members with thickness ranging from / to 8 / inches (38 to 6 mm). Allowable fastener tension and shear strengths are shown in Table. 4.. Connection Strengths: Reference withdrawal (W), lateral (Z), and head pull-through (P) design values for the fasteners installed in wood members are given in Tables, 3 and 4, respectively. These values are applicable to wood side and main members having a moisture content less than or equal to 9 percent at the time of screw installation and while in service. For unseasoned or partially seasoned wood members and wood members used in wet service conditions, the wet service factors, C M, shown in the tables must be used to adjust the reference design values. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 06 ICC Evaluation Service, LLC. All rights reserved. Page of 5 000

ESR-353 Most Widely Accepted and Trusted Page of 5 The allowable lateral load for a single-fastener connection is the lesser of (a) the reference lateral design value given in Table 3, adjusted by all applicable adjustment factors; or (b) the allowable fastener shear strength given in Table. The allowable load for a singlefastener connection in which the fastener is subject to tension is the least of (a) the reference withdrawal design value given in Table, adjusted by all applicable adjustment factors; (b) the reference head pull-through design value given in Table 4, adjusted by all applicable adjustment factors; or (c) the allowable fastener tension strength given in Table. Reference design values must be multiplied by all applicable adjustment factors, as specified for dowel-type fasteners and wood screws in the NDS. When the adjusted lateral design value (Z') of a single-fastener connection exceeds the allowable shear strength of the fastener itself, as specified in Table, the design lateral load of the connection must be limited to the shear value specified in Table, without any load duration adjustments. When the lesser of the adjusted withdrawal design value (W') and the adjusted pull-through design value (P') of a single-fastener connection exceeds the allowable tensile strength of the fastener itself, as specified in Table, the design load of the connection must be limited to the tension value specified in Table, without any load duration adjustments. Connections containing multiple fasteners must be designed in accordance with Sections.. and.6 of NDS-5 (Sections 0.. and.6 of NDS- and NDS-05 for the 0, 009 and 006 IBC). Where the fasteners are subjected to combined lateral and withdrawal loads, connections must be designed in accordance with Section.4. of NDS-5 (Section.4. of NDS- and NDS-05 for the 0, 009 and 006 IBC). When designing a connection, the structural members must be checked for load-carrying capacity in accordance with Section.. of NDS-5 (Section 0.. of NDS- and NDS-05 for the 0, 009 and 006 IBC), and local stresses within the connection must be checked against Appendix E of the NDS to ensure the capacity of the connection and fastener group. 4..3 Use with Treated Wood: 4..3. IBC: The fasteners may not be used in contact with preservative-treated wood, with the exception that for applications under the 05, 0 and 009 IBC, the fasteners may be used with SBX/DOT and zinc borate preservative-treated wood in interior, dry environments, in accordance with the Exception to 05 IBC Section 304.0.5. (0 and 009 IBC Section 304.9.5.). The fasteners may be used in fire-retardant-treated wood in interior locations in accordance with 05 IBC Section 304.0.5.4 (0 and 009 IBC Section 304.9.5.4) and Grabber s recommendations. 4..3. IRC: The fasteners may be used in contact with preservative-treated wood in accordance with Exception to 05, 0 and 009 IRC Section R37.3. and Exception to 006 IRC Section R39.3. The fasteners may be used in contact with fire-retardant-treated wood in accordance with 05, 0 and 009 IRC Section R37.3.3 and Exception to 006 IRC Section R39.3. 4. Installation: The Lag-Master and Tie-Master fasteners must be installed in accordance with the report holder s published installation instructions and this report. The fasteners must be installed in accordance with Section..4 of NDS-5 (Section..4 of NDS- and NDS-05 for the 0, 009 and 006 IBC). The fasteners must be installed such that their main axis is oriented perpendicular to the wood grain. The side member must be in direct contact with the main member, such that no gap exists between the wood members. Clearance holes for the fastener shanks and pilot holes for the threaded portion of the fasteners must be drilled prior to installation of the Lag-Master and Tie-Master fasteners. The clearance holes in the side members must be 3 / 64 inch (5.6 mm) in diameter for both the Lag-Master and Tie-Master fasteners. The pilot holes in the main members must be / 8 -inch in diameter with length equal to the length of the threaded portion of the fastener. A hammer must not be used to install the fasteners. The Lag-Master fasteners must be installed by turning with a wrench or socket. Upon installation, the underside of the Lag-Master fastener head must be flush with the surface of the side member. The Tie-Master fasteners must be installed by turning with star drive (Torx) bits. Upon installation, the top of the Tie-Master fastener head must be flush with the surface of the side member. Minimum end distances, edge distances and spacing of the fasteners must be sufficient to prevent splitting of the wood, or as required by Table 5, whichever is greater. 5.0 CONDITIONS OF USE The Grabber Lag-Master and Tie-Master Multipurpose Wood Fasteners described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section.0 of this report, subject to the following conditions: 5. The fasteners must be installed in accordance with the manufacturer s published installation instructions and this report. In case of a conflict between this report and the manufacturer s installation instructions, this report governs. 5. Use of the fasteners in wood structural panel diaphragms and shear walls is outside the scope of this report. 5.3 Calculations and details demonstrating compliance with this report must be submitted to the code official. The calculations and details must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 5.4 Refer to Section 4..3 for guidance regarding use of the fasteners in contact with preservative-treated or fire-retardant-treated wood. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Alternate Dowel Type Threaded Fasteners (AC33), dated April 05. 7.0 IDENTIFICATION The fasteners are identified by a G or a proprietary symbol marked on the fastener head as shown in Figure. Packages of fasteners are identified with the company name (Grabber ), fastener series (Lag-Master or Tie-Master ), fastener size and length and the evaluation report number (ESR-353).

ESR-353 Most Widely Accepted and Trusted Page 3 of 5 FASTENER DESIGNATION Lag-Master Tie-Master OVERALL LENGTH TABLE LAG-MASTER AND TIE-MASTER FASTENERS THREAD LENGTH #4 x 7 / 8 " 7 / 8.46 #4 x 3 3 / 8 " 3 3 / 8.8 #4 x 3 5 / 8 " 3 5 / 8.8 #4 x 3 7 / 8 " 3 7 / 8.96 #4 x 4 7 / 8 " 4 7 / 8.48 #4 x 5" 5.48 #4 x 5 7 / 8 " 5 7 / 8.9 #4 x 4" 4 #4 x 6" 6 #4 x 8" 8 #4 x 0" 0 For SI: inch = 5.4 mm; lbf = 4.45 N; psi = 6.9 kpa. ROOT THREAD DIAMETER D r SHANK DIAMETER OUTSIDE THREAD DIAMETER SPECIFIED BENDING YIELD STRENGTH 3 (psi) ALLOWABLE FASTENER STRENGTH Tension (lbf) Shear (lbf) 0.80 0.00 0.50 50,000,86 905.48 0.80 0.00 0.50 50,000,49,046 The overall length of a LAG-MASTER fastener is measured from the underside of the head to the bottom of the tip. The overall length of a TIE-MASTER fastener is measured from the top of the head to the bottom of the tip. Length of thread includes tip. 3 Bending yield strength determined in accordance with ASTM F575 using the root diameter. Lag-Master TABLE REFERENCE WITHDRAWAL DESIGN VALUES (W) Tabulated Withdrawal Design Values (W) Are in Pounds per Inch of Thread Penetration into Side Grain of Main Member FASTENER DESIGNATION THREAD LENGTH, L W (lbf/in.) 3 Specific Gravity = 0.50 WET SERVICE FACTOR #4 x 7 / 8 ".46 #4 x 3 3 / 8 ".8 #4 x 3 5 / 8 ".8 #4 x 3 7 / 8 ".96 9 0.55 #4 x 4 7 / 8 ".48 #4 x 5".48 #4 x 5 7 / 8 ".9 #4 x 4" #4 x 6" #4 x 8".48 80 0.65 #4 x 0" For SI: inch = 5.4 mm; lbf/in = 75 N/m. Tie-Master Values shall be multiplied by all applicable adjustment factors (see NDS). Reference withdrawal design values must be multiplied by the length of the thread penetration in the main member. Length includes tapered tip. 3 Specific gravity must be the assigned specific gravity for sawn lumber per the NDS.

ESR-353 Most Widely Accepted and Trusted Page 4 of 5 TABLE 3 REFERENCE LATERAL DESIGN VALUES (Z) FOR SINGLE SHEAR (TWO-MEMBER) CONNECTIONS LOADED PARALLEL (Z ll ) OR PERPENDICULAR (Z ) TO THE GRAIN For Sawn Lumber with Both Members of Identical Specific Gravity FASTENER DESIGNATION #4 x 7 / 8 " SIDE MEMBER THICKNESS, t s MINIMUM FASTENER PENETRATION, P Z (lbf) Min. Max. Specific Gravity = 0.50 / 3 / 8 WET SERVICE FACTOR Lag-Master #4 x 3 3 / 8 " 3 / 4 5 / 8 #4 x 3 5 / 8 " 5 / 8 #4 x 3 7 / 8 " / / 3 / 8 #4 x 4 7 / 8 " 3 / 3 / 8 #4 x 5" 3 / / 5 0.70 Tie-Master #4 x 5 7 / 8 " 4 / 4 5 / 8 #4 x 4" / #4 x 6" 4 / #4 x 8" / 6 / #4 x 0" 8 / For SI: inch = 5.4 mm; lbf = 4.45N. Values shall be multiplied by all applicable adjustment factors (see NDS). Specific gravity must be the assigned specific gravity for sawn lumber per the NDS. / 5 0.70 FASTENER DESIGNATION LAG-MASTER TIE-MASTER For SI: inch = 5.4 mm; lbf = 75 N/m. TABLE 4 REFERENCE PULL-THROUGH DESIGN VALUES (P) MINIMUM SIDE MEMBER THICKNESS, t s (inch) P (lbf) FOR SPECIFIC GRAVITY OF 0.5 WET SERVICE FACTOR 3 / 4 0.55 3 / 4 08 0.65 Values shall be multiplied by adjustment factors, as applicable to the reference withdrawal values, W, in accordance with the NDS. Specific gravity must be the assigned specific gravity for sawn lumber per the NDS. End distance TABLE 5 LAG-MASTER TM and TIE-MASTER TM CONNECTION GEOMETRY REQUIREMENTS MINIMUM DISTANCE OR SPACING CONDITION Fastener Diameters Inches Loading toward end 5 3 Loading away from end 5 3 Loading perpendicular to grain 5 3 Edge distance Any load direction 5 3 Spacing between fasteners in a row Spacing between rows For SI: inch = 5.4 mm Loading parallel to grain 5 3 Loading perpendicular to grain 0 In-line rows 5 Staggered rows.5 End distances, edge distances and fastener spacing must be sufficient to prevent splitting of the wood, or as required by this table, whichever is the more restrictive. Values for spacing between staggered rows apply where fasteners in adjacent rows are offset by half of the spacing between fasteners in a row. /

ESR-353 Most Widely Accepted and Trusted Page 5 of 5 LAG MASTER TIE MASTER FIGURE GRABBER FASTENERS

ICC-ES Evaluation Report ESR-353 CBC and CRC Supplement Issued August 05 This report is subject to renewal April 07. www.icc-es.org (800) 43-6587 (56) 699-0543 A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 3 Wood, Plastic, and Composite Fastenings REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. 0 WEST MAIN STREET COURT ALPINE, UTAH 84004 (95) 680-0777 www.grabberman.com EVALUATION SUBJECT: GRABBER LAG-MASTER AND TIE-MASTER MULTI-PURPOSE WOOD FASTENERS.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Grabber Lag-Master and Tie-Master Multi-purpose Wood Fasteners, recognized in ICC-ES master evaluation report ESR-353, have also been evaluated for compliance with the codes noted below. Applicable code edition: 03 California Building Code (CBC), Chapter 3 03 California Residential Code (CRC).0 CONCLUSIONS. The Grabber Lag-Master and Tie-Master Multi-purpose Wood Fasteners, described in Sections.0 through 7.0 of the master evaluation report ESR-353, comply with CBC Chapter 3, provided the design and installation are in accordance with the 0 International Building Code provisions noted in the master report and the additional requirements of the CBC Chapters 7, 7A, and 3, as applicable.. The Grabber Lag-Master and Tie-Master Multi-purpose Wood Fasteners, described in Sections.0 through 7.0 of the master evaluation report ESR-353, comply with the CRC, provided the design and installation are in accordance with the 0 International Residential Code provisions noted in the master report. This supplement expires concurrently with the master report, reissued April 05 and corrected February 06. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 06 ICC Evaluation Service, LLC. All rights reserved. Page of 000

ICC-ES Evaluation Report www.icc-es.org (800) 43-6587 (56) 699-0543 ESR-353 FBC Supplement Issued August 05 This report is subject to renewal April 07. A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 3 Wood, Plastic, and Composite Fastenings REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. 0 WEST MAIN STREET COURT ALPINE, UTAH 84004 (95) 680-0777 www.grabberman.com EVALUATION SUBJECT: GRABBER LAG-MASTER AND TIE-MASTER MULTI-PURPOSE WOOD FASTENERS.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Grabber Lag-Master and Tie-Master Multipurpose Wood Fasteners, recognized in ICC-ES master evaluation report ESR-353, have also been evaluated for compliance with the codes noted below. Applicable code editions: 04 Florida Building Code Building 04 Florida Building Code Residential.0 CONCLUSIONS The Grabber fasteners, described in Sections.0 through 7.0 of the master evaluation report ESR-353, comply with the 04 Florida Building Code Building and the 04 Florida Building Code Residential, provided the design and installation are in accordance with the 0 International Building Code provisions noted in the master report and the following: The self-drilling screws must be limited to dry, interior locations, which include exterior walls which are protected by an exterior wall envelope. Use of the Grabber fasteners has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the 04 Florida Building Code Building and the 04 Florida Building Code Residential. For products falling under Florida Rule 9N-3, verification that the report holder s quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued April 05 and corrected February 06. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 06 ICC Evaluation Service, LLC. All rights reserved. Page of 000