CX8091 Embedded PC for BACnet/IP

Similar documents
C ed P d ed b Em 184

TYPE APPROVAL CERTIFICATE

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Manual CX9020. Embedded PC. Version: Date:

CANtrol EC Modular Control System Powerful and versatile

applicomio Profibus-DP

DCS Data and communication server

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

BACnet. bcx1 Controller/ Router Series

CPUs - CPU PN/DP

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

HMI. Operating and monitoring.

PC & EMBEDDED CONTROL TRENDS

CP Page 1342 Mar 2008 Siemens ITS

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

TX OPEN RS232/485 module

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

The CP provides access to different communication services of the PROFIBUS bus system:

DCS data and communication server

Panel PC SIMATIC HMI IPC577C

AXIS 262+ Network Video Recorder

FOR IMMEDIATE RELEASE

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

EXOR INTERNATIONAL.

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Maritime HMI - S Line.

Data sheet SLIO CPU 015 (015-CEFPR00)

Z-TWS4. Multifunction Straton / LINUX Controller.

IOVU-571N ARM-based Panel PC

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

PCS0100en Persy Control Services B.V. Netherlands

WP WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

WinCon Programmable Automation. Controller

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

Embedded PC The modular Industrial PC for mid-range control. Embedded PC 1

SIMATIC HMI IPC 477C 1/5. Copyright Siemens AG 2013

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Chapter 5 Cubix XP4 Blade Server

YZP : SAUTER Vision Center

Industry First X86-based Single Board Computer JaguarBoard Released

Application Server V240 Platform

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Embedded & Industrial PCs International Products and Configurations INDEX

Cisco MCS 7816-I3 Unified Communications Manager Appliance

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

Box PC Fanless. Box PC Performance

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

SIMATIC IPC477D 1/5. Copyright Siemens AG 2014

Matrox 4Sight GP. Industrial imaging computer with desktop-level performance and expansion. The right fit for machine vision or medical imaging

Phone and Fax: (717) or Send to- On the Internet at

Turn on and immediately start with the engineering! siemens.com/simatic-pg

S7-1500/S7-1500F Technical Data

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Chapter 13. PIC Family Microcontroller

CP BACnet 6FL4343-1CX10-0XE0 DESIGO S7. Used with DESIGO S7, Building Solution & Building Integration

Data Sheet Fujitsu FUTRO A300 Thin Client

Light Industrial Panel PC

Datasheet. Unified Video Surveillance Management. Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR. Scalable Day or Night Surveillance

Tracer Summit Web Server

S-series SQ Controller

A-307. Mobile Data Terminal. Android OS Platform Datasheet

The CP FO provides access to different communication services of the PROFIBUS bus system:

Display units With alphanumeric screen

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

PROGRAMMABLE LINUX GATEWAY WITH JAVA AND OSGI

EtherCAT the Ethernet fieldbus

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

Human Machine Interface

Scout 1U Rackmount Computer

Ultra Thin Client TC-401 TC-402. Users s Guide

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

EtherCAT Cutting Costs with High-speed Ethernet

Operating Guide EPIA EX-Series Mini-ITX Mainboard

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Cisco MCS 7825-H2 Unified CallManager Appliance

AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset

User manual Compact Web PLC WP240 series IEC-line

MAINTENANCE WITHOUT TRAVELLING

MLC TM Maximum Productivity and Versatility for Control without Compromise!

S7-1500/S7-1500F Technical Data

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Introduction to PROFIBUS and PROFINET

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Syslogic Product Overview. Embedded Computer HMI Systems Single Board Computer Railway Computer

deltadue series gateways: PROFIBUS DP, DeviceNet, CANopen, Modbus TCP to Modbus RTU

Product Brief. R7A-200 Processor Card. Rev 1.0

System Design Issues in Embedded Processing

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

SCADAPack 530E 535E. remote Programmable Automation Controller

Designed for the needs of automation, telecommunications, remote supervision, and monitoring

Fujitsu ESPRIMO P2560 Desktop PC

MOI DVB-S2 Streaming Box Quick Start Guide

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Beckhoff TwinCAT The Windows Control and Automation Technology. TwinCAT NC PTP Examples

Configuring PROFINET

Data Sheet FUJITSU Thin Client FUTRO A300

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Transcription:

CX8091 Ethernet port Link/Act Ethernet RJ 45 (switched) 10/100 Mbaud Link/Act Ethernet RJ 45 (switched) 10/100 Mbaud Adress selector Power LEDs E-bus or K-bus Bus Coupler supply Front flap Input for power contacts Power contacts CX8091 Embedded PC for BACnet/IP The CX8091 is a compact, DIN rail-mountable Ethernet controller with a 400 MHz 32-bit CPU. The BACnet or OPC UA protocols can be operated via the switched Ethernet fieldbus interface. Alternatively K-bus or E-bus terminals can be connected; the CX8091 automatically detects which system is connected during the start-up phase. The control system is programmed with TwinCAT 2 via the fieldbus interface or the additional Ethernet port. BACnet (Building Automation Control Network) is a standardised, manufacturer-independent communication protocol for building automation. Areas of application include HVAC, lighting control, safety and fire alarm technology. Technical data CX8091 Programming TwinCAT 2 PLC Programming languages IEC 61131-3 Web visualisation yes Online change yes Up/down load code yes/yes 1 x Ethernet 10/100 Mbit/s, 1 x USB device (behind the front flap) Bus interface 2 x RJ 45 (switched) I/O connection E-bus (EtherCAT Terminals) or K-bus (Bus Terminals), automatic recognition internal battery-backed clock for time and date (battery behind the front flap, exchangeable) UPS 1-second UPS (for 1 MB of persistent data) Operating system Microsoft Windows CE 6 Web-based management yes Max. power loss 3 W Dimensions (W x H x D) 65 mm x 100 mm x 80 mm Operating/storage temperature 0 +55 C/-25 +85 C

CX9020-0111 Status LEDs Ethernet and USB connection E-bus/K-bus interface Battery compartment 2 x microsd DVI connection CX9020 Basic CPU module with BACnet/IP The CX9020 is a compact, DIN rail-mountable Ethernet control system with 1 GHz ARM Cortex -A8 CPU. The connection for the Beckhoff I/O systems is directly integrated into the CPU module. The unit offers automatic bus system identification (K-bus or E-bus) and independently switches in the corresponding mode. The CX9020 comprises the CPU with two microsd card slots, the internal RAM and 128 kb NOVRAM as non-volatile memory. The basic configuration also includes two switched Ethernet RJ 45 interfaces, four USB-2.0 interfaces and a DVI-D interface. The RJ 45 interfaces are connected to an internal switch and offer a simple option for creating a line topology without the need for additional Ethernet switches. The operating system is Microsoft Windows Embedded Compact 7. TwinCAT 2 automation software transforms a CX9020 system into a powerful PLC and Motion Control system that can be operated with or without visualisation. Optionally, the unit can be ordered with a fieldbus, serial or audio interface. BACnet (Building Automation Control Network) is a standardised, manufacturerindependent communication protocol for building automation. BACnet/IP is used in HVAC, lighting control, security and fire alarm technology. With the TwinCAT BACnet/IP supplement, the CX9020 becomes a BACnet controller with B-BC-profile, which can act as a client or server. Thanks to the range of over 400 different Bus Terminals, the Embedded PC can also be used as a gateway between DALI, EnOcean, EIB/KNX, LON, M-Bus, MP-Bus, Modbus and other interfaces. BACnet objects can be created and managed simply and clearly with the aid of the system manager. The BACnet properties of client and server objects can be read and also written both acyclically via ADS and cyclically as process data. If the order option CX1800-1052 is chosen, the Embedded PCs are delivered with WEC7 operating system with a pre-installed and certified BACnet image. The image already contains the licence key. +60 C -25 C The extended operating temperature range between -25 and +60 C enables application in climatically demanding situations. The order identifier of the basic CPU module is derived as follows: Optional interfaces: CX9020-N020 = audio interface CX9020-N030 = RS232, D-sub plug CX9020-N031 = RS422/RS485, D-sub socket CX9020-B110 = EtherCAT slave, EtherCAT IN and OUT (2 x RJ 45) CX9020-M310 = PROFIBUS master, D-sub socket, 9-pin CX9020-B310 = PROFIBUS slave, D-sub socket, 9-pin CX9020-M510 = CANopen master, D-sub plug, 9-pin CX9020-B510 = CANopen slave, D-sub plug, 9-pin CX9020-M930 = PROFINET RT, controller CX9020-B930 = PROFINET RT, device, Ethernet (2 x RJ 45 switch) CX9020-B950 = EtherNet/IP slave, Ethernet (2 x RJ 45 switch)

CX9020-0111 Technical data CX9020 Processor ARM Cortex -A8, 1 GHz Flash memory 256 MB microsd (optionally expandable), 2 x microsd card slot Internal main memory 1 GB DDR3 RAM Persistent memory 128 KB NOVRAM integrated 2 x RJ 45 (Ethernet, internal switch), 10/100 Mbit/s, DVI-D, 4 x USB 2.0, 1 x optional interface Diagnostics LED 1 x power, 1 x TC status, 2 x flash access, 2 x bus status internal battery-backed clock for time and date (battery exchangeable) Operating system Microsoft Windows Embedded Compact 7, English Control software TwinCAT 2 CE PLC runtime Power supply 24 V DC (-15 %/+20 %) Dielectric strength 500 V (supply/internal electronics) NOVRAM 128 kbytes Max. power loss 5 W (including the system interfaces) Dimensions (W x H x D) 85 mm x 100 mm x 91 mm Operating/storage temperature -25 +60 C/-25 +85 C Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4 Ordering information CX9020-0111 + CX1800-1052 Embedded PC CX9020 with TwinCAT PLC runtime and BACnet/IP image

CX5010, CX5020 Ethernet and USB connection Status LEDs E-bus/K-bus interface Battery compartment DVI connection Compact Flash insert CX5000 Embedded PC series with BACnet/IP The CX5010 and CX5020 are Embedded PCs from the CX5000 series based on Intel Atom processors and differ only by the CPU version. The CX5010 has a 1.1 GHz Intel Atom Z510 processor, while the CX5020 has a 1.6 GHz Intel Atom Z530 processor. Apart from the clock speed, the two processors also differ by the fact that the Z530 features hyperthreading technology, i.e. it has two virtual CPU cores for more effective execution of software. BACnet (Building Automation Control Network) is a standardised, manufacturer-independent communication protocol for building automation. BACnet/IP is used in HVAC, lighting control, security and fire alarm technology. The TwinCAT BACnet/IP supplement transforms the CX50x0 into a BACnet controller with B-BC profile that can act as a client or server. Thanks to the range of over 400 different Bus Terminals, the Embedded PC can also be used as a gateway between DALI, EnOcean, EIB/KNX, LON, M-Bus, MP-Bus, Modbus and other interfaces. BACnet objects can be created and managed simply and clearly with the aid of the system manager. BACnet properties of client and server objects can be read and also written via ADS and cyclically as process data. If the order option CX1800-1052 is chosen, Embedded PCs are delivered with CE6 operating system with a pre-installed and certified BACnet image. The image already contains the necessary licence key. For Embedded PCs with WES2009 operating system (Windows Embedded Standard 2009) the TS8020 TwinCAT BACnet/IP Supplement must be activated with the licence key. +60 C -25 C The extended operating temperature range between -25 and +60 C enables application in climatically demanding situations. The order identifier of the CX5000 devices is derived as follows: CX50x0-x1x1 1 = operating system Windows CE 2 = operating system Windows Embedded Standard 0 = E-bus interface for EtherCAT Terminals 1 = K-bus interface for Bus Terminals 1 = CPU Intel Atom processor 1.1 GHz 2 = CPU Intel Atom processor 1.6 GHz Since not all combinations make sense, the table Ordering information contains a breakdown of the permissible combinations. Optional interfaces: CX50x0-N020 = audio interface CX50x0-N030 = RS232, D-sub plug CX50x0-N031 = RS422/RS485, D-sub socket CX50x0-M310 = PROFIBUS master, D-sub socket, 9-pin CX50x0-B310 = PROFIBUS slave, D-sub socket, 9-pin CX50x0-M510 = CANopen master, D-sub plug, 9-pin CX50x0-B510 = CANopen slave, D-sub plug, 9-pin CX50x0-M930 = PROFINET RT, controller CX50x0-B930 = PROFINET RT, device, Ethernet (2 x RJ 45 switch) CX50x0-B950 = EtherNet/IP slave, Ethernet (2 x RJ 45 switch) CX50x0-B110 = EtherCAT slave, EtherCAT IN and OUT (2 x RJ 45)

CX5010, CX5020 Technical data CX5010-x1x1 CX5020-x1x1 Processor processor Intel Atom Z510, 1.1 GHz clock frequency processor Intel Atom Z530, 1.6 GHz clock frequency Flash memory 64 MB Compact Flash card (optionally extendable) Internal main memory 512 MB RAM (internal, not expandable) 512 MB RAM (optionally 1 GB installed ex factory) Persistent memory integrated 1-second UPS (1 MB on Compact Flash card) 2 x RJ 45, 10/100/1000 Mbit/s, DVI-D, 4 x USB 2.0, optional 1 x RS232/RS422/RS485 Diagnostics LED 1 x power, 1 x TC status, 1 x flash access, 2 x bus status internal battery-backed clock for time and date (battery exchangeable) Operating system Microsoft Windows CE or Microsoft Windows Embedded Standard Control software TwinCAT 2 PLC runtime or TwinCAT 2 NC PTP runtime Power supply 24 V DC (-15 %/+20 %) Dielectric strength 500 V (supply/internal electronics) Max. power loss 12 W (including the system interfaces) 12.5 W (including the system interfaces) Dimensions (W x H x D) 100 mm x 100 mm x 91 mm Operating/storage temperature -25 +60 C/-40 +85 C Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4 Ordering information E-bus K-bus Windows CE 6 Windows Embedded Standard 2009 TwinCAT 2 PLC runtime CX5010-0111 + CX1800-1052 x x x CX5010-0121 + TS8020 x x* x CX5010-1111 + CX1800-1052 x x x CX5010-1121 + TS8020 x x* x Ordering information E-bus K-bus Windows CE 6 Windows Embedded TwinCAT 2 PLC Standard 2009 runtime CX5020-0111 + CX1800-1052 x x x CX5020-0121 + TS8020 x x* x CX5020-1111 + CX1800-1052 x x x CX5020-1121 + TS8020 x x* x *CX50x0 systems with Microsoft Embedded Standard 2009 require Compact Flash with a capacity of at least 2 GB (must be ordered separately). Options CX50x0 with CE CX50x0 with XPe ordering number of the CX + CX1800-1052 (BACnet image) ordering number of the CX + TS8020 supplement TwinCAT BACnet/IP (licence key necessary), TwinCAT 2.11 R3