MAS (Magnesite Anode System)

Similar documents
Chapter 2 Basis of design and materials

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CATHODIC PROTECTION OF REINFORCED CONCRETE STRUCTURES

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

SikaProof A Technology

Embedded Parts Introduction - Anchors

Asphalt Shingle Application Requirements

CATHODIC PROTECTION SYSTEM DESIGN

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

WATERPROOFING OF WET ROOMS

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Dissimilar Metal Corrosion

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Site Inspection Report

WATERPROOFING FOR CONCRETE STRUCTURES

BLACK JACK ALL WEATHER ROOF COATING

Rudder Repair and refinish

WATERPROOFING SikaProof -A TECHNOLOGY

Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

G VYCOR DECK PROTECTOR

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

Durability of reinforced concrete pipe the hard facts!

Sika FerroGard The Unique Multi-Functional Surface Applied Corrosion Inhibitor for Reinforced Concrete. Innovation & Consistency.

Chapter. Restoration of Damaged Structures

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

GARDEN CITY SKYWAY SUBSTRUCTURE REHABILITATION

Installation PowerPoint for Grasscrete Formers

How to build a Pizza Oven in 4 days

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

MEMORANDUM West Swann Avenue, Suite 225 Tampa, Florida Phone (813) Fax (813)

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

Fame Design Ltd (10295) Plot # A-115/116,BSCIC Hosiery I/A, Narayangonj, Bangladesh ( , ) 18.June.2014

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

White rust on galvanized and galvanized pre-painted steel. Technical Information

Preservation, Repair and Rehabilitation of Concrete Bridges, Pavements and Tunnels in Virginia

DELTA Premium Moisture Management Systems for Foundations.

University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Retail Price List 2015

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Division 9. SignaFlor Pad and Pour Flooring System

Minor Cracks in Horizontal Surfaces

Swimming Pool Tiling Specialists

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

WATERPROOFING BASEMENTS

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

BENTLEY ELEMENTS COLLECTION LVT

LAYING BLOCK AND BRICK

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

Design and Construction of Cantilevered Reinforced Concrete Structures

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Concrete Waterproofing Systems. Integral Protection.

Membrane for tunnels and underground construction

If stepping is required, step at 180mm as seen in this picture.

Puddle Flange. FRANK Puddle Flange

How to Install GoBoard:

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Measuring the Condition of Prestressed Concrete Cylinder Pipe

Plastics Engineering SYSTEM BEKAPLAST. Mechanically anchored thermoplastic lining for extreme conditions

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Metropolitan Builders Association Masonry & Concrete Standard

SEAMS SEAMING USING SEAM TAPE

PRE INSTALLATION MANUAL

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Waterproofing construction Joints

orizontal BarrierS PATENTED SYSTEM

Passive Fire Protection

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

PERFORMANCE GUIDELINES

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

12.1 Schlüter -KERDI-BOARD

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

We re about to build.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

SECTION STORM DRAINAGE SYSTEM

Specification for Pipe Coating Repairs Offshore

EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SURFACE COATINGS FOR CONCRETE

Technical Services. Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking)

Crevice Corrosion on Stainless Steel Propeller Shafts

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Transcription:

MAS (Magnesite Anode System) MAS (Magnesite Anode System) is a protection system specifically devoloped to control the corrosion of the reinforcement caused by magnesite floorings. The chlorides in magnesite toppings can penetrate to the underlying floor reinforcement which then corrodes causing concrete spalling and delamination. Conventional repairs can be expensive and unreliable as it is difficult to remove all the chlorides. corrpre have developed two low cost effective electro chemical systems. One is to bond zinc sheet with Zinc Activator Paste (ZAP TM ) to the concrete surface the other is to apply Zinc Layer Anode (ZLA TM ) to the soffit. With a connection to the reinforcement either system provides galvanic cathodic protection to the reinforcment to ensure corrosion is halted with minimal concrete and topping removal. Spalling Concrete Initially at Openings. 1. Magnesite Problem Magnesite floor toppings were used extensively in the 60 s and 70 s to provide a smooth flat finish on rough finished slabs. The main component of these toppings was magnesia, fillers and magnesium chloride solution. After hardening the pores in the topping remained filled with the hygroscopic magnesium chloride solution. Over time the chlorides penetrate to the floor reinforcement and can cause corrosion. As early as 1962 the corrosive effects were known and in Germany recommendations for use of Magnesite toppings included that the concrete remain dry. DIN 18560 1992 on screeds requires a waterproof barrier between the topping and slab. However these recommendations are often inadequately applied and Magnesite floor corrosion problems are common. Corrosion typically occurs first at wetted areas as the chlorides diffuse through water in the pores and the water lowers the resistivity of the corrosion cell. However once damage is observed in wetted areas corrosion is likely to have commenced elsewhere and the whole floor must be considered in the repair solution.

Pagina 2 van 5 2. Conventional Repair Issues In discussions with corrpre repair contractors involved in Magnesite floor repairs noted the following concerns with conventional patch repairs: Corroding reinforcement is often repaired by breaking out the damaged concrete and patching. Where chlorides are involved it is universally agreed that the concrete behind the bar must be broken out to remove the chlorides. This undamaged concrete behind bars is difficult to remove. If only damaged areas are broken out then incipient anodes will form unless some form of cathodic prevention is included for the areas around the patch (e.g. corrpre s GSC super anodes). If only damaged concrete is repaired then it is likely other areas in the slab with slightly less chloride penetration will fail in the future unless other measures are taken, e.g. remove the entire Magnesite topping to remove the chloride reservoir and dry out the concrete and provide a water proof membrane to keep out any future dampness. These measures are expensive and still leave a risk of failure. The contractors recognise that cathodic protection is the only assured way of stopping corrosion without the need for all of the above measures but noted practical systems for this application had not been developed. 3. Galvanic Cathodic Protection Galvanic Cathodic Protection (GCP) is where an anode is connected to the reinforcement and embedded in or adhered to the concrete. The anode is designed such that all the reinforcement becomes cathodic and cannot corrode. Anodes may either be impressed current (ICCP) or sacrificial (GCP). ICCP requires extensive wiring and monitoring around twice a year to check functionality and are considered impractical for apartments as maintenance costs are too high.gcp systems had been available decades but the anodes were too small to provide a practical means of applying global CP. Their main purpose was for use around the edges of repairs to reduce the risk of incipient anode failure. By contrast ZLA or MAS provides a very high surface area capable of polarizing the reinforcement globally to give a true GCP system that negates the need to break out chloride contaminated toppings and concrete. The concept of CP is described in other data sheets on ZLA. 4. MAS (Magnesite Anode System) CorrPRE are the inventors of a series of sacrificial zinc anode systems for reinforced concrete. These systems have been applied in Europe for 10 years. On introducing these systems in various countries repair contractors asked if corrpre s ZLA system could be applied to prevent future corrosion without removal of Magnesite toppings and without extensive concrete breakout. corrpre knew the ZLA system would provide adequate protection if it could be applied to soffits (see 2

Pagina 3 van 5 data sheet on ZLA for details of application) but the contractors advised this was often not possible. The problem of using ZLA on tops of slabs is that the activation paste can get squeezed out. Hence corrpre set about developing a system specifically for the tops of slabs that could be applied under an underlayment. The system adopted is to use zinc sheet with a site applied ZAP. ZAP dries to a relatively stiff paste that is less likely to squeeze out. But the system is also designed with supports under the underlayment to reduce the load applied to the ZAP. For full compliance with Cathodic Protection codes monitoring of CP systems is required and this entails wiring of system back to a junction box to permit intermittent the monitoring. This is important with ICCP systems as the current has to be adjusted over time. With GCP system there is no such adjustment and hence monitoring is not required. The MAS system is based on checking for appropriate polarisation of the reinforcement and then sealing up the CP system. A step by step guide is given in the figure below. The ZAP on Zinc Sheet The ZAP is applied with a cartridge gun with wide nozzle After covering the zinc sheet to within 20mm of the edges the zinc sheet is flipped and pressed onto the concrete. A rubber mallet is used to fully press out the sheet. The negative return to the reinforcement is brazed to the zinc and the supports located at holes in the sheet The primer is applied (red) and the floor screed is applied across the top. 3

Pagina 4 van 5 5. Application Guide a) Break out surface to sound concrete. No need to remove sound but chloride contaminated concrete and no need to remove the Magnesite topping unless the thickness is an issue. b) Make two connections to reinforcement in the top and bottom mat. Wire bottom mat connection back to points on the top surface (NB: If the design engineer is confident that the bottom mat is electrically continuous with the top mat then the connection to the bottom mat may be omitted) d) Use standard concrete patch repair system suitable for use with cathodic protection to build floor to flat surface. e) Cut 125mm wide 250 micron thick zinc sheet rolls to lengths equal to the width of the floor less 200mm (leaves 100mm tolerance / topping bonding strip at each end). f) Bunch 20 mm holes along each edge of zinc strip at 200mm centres. These holes are to for plastic disc supports. g) Apply zinc paste as shown in above figure to one side of a strip of zinc sheet. Turn sheet and press down onto concrete surface. h) Press 30mm diameter x 2mm thick plastic discs over each punch hole pressing out any ZAP beneath. These discs transfer load from the topping to the leveled slab without compressing the zinc tape so the ZAP is not squeezed out. i) Repeat process for each strip of zinc leaving 100mm between each strip or alternate strips depending on steel density and design life (preference is to walk on the 100mm strips but the zinc sheet can be walked on). j) Electrically connect each end of zinc strips in series back incorporating rebar connections to top and bottom mat by brazing connections to zinc sheet. Make rebar connections so that they can be disconnected temporarily. Leave to polarize reinforcement for seven?? days. Disconnect reinforcement connections. Undertake 4hr and 24hr depolarisation tests using surface half cells to check code CP protection criteria. Reconnect rebar connections permanently (i.e. soldered and insultaed). l) Apply Ardex P82 primer to all zinc surface and exposed concrete. m) Apply Ardex K22 or K11 mortar over top of whole floor. 4

Pagina 5 van 5 6. Pre Application Inspection There is little point in repairing the area of apparent damage only to find that other areas spall a few years later. Hence pre-repair testing is required unless the whole floor is to be protected. To identify the extent of corrosion electrical potential measurement are taken over the surface of the floor. Beul 2003 assessed the active potential for Magnesite floors and found it was approximately -150mv vs CuSO 4 cells. Where potentials are more positive than -150mv it suggests that chlorides have not penetrated to the rebar and if these areas of floor are kept dry there may be no future corrosion. Hence the MAS Magnesite system is only applied to area where the potentials are more negative than -150m CuSO 4. Contacts For further details please contact a corrpre licensed applicator or call corrpre. References Beul W. & Menzel K. 2003 Corrosion damages caused by cast magnesite floor screeds ================================================================= CorrPRE Engineering, Reeuwijk, Nethrlands Revision Nr. Revision date Approved 01 26 th januari 2012 R.Giorgini 5