MODEL CH607 INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. - Eng 1 -

Similar documents
INSTRUCTION MANUAL HEM-6052

Automatic Wrist Blood Pressure Monitor with

Upper Arm Blood Pressure Monitor SC Instructions for use

How to measure blood pressure using digital monitors

INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785CAN FRANÇAIS ENGLISH

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785 ESPAÑOL ENGLISH

INSTRUCTION MANUAL. 7 series Blood Pressure Monitor with ComFit TM Cuff. Model BP760 ESPAÑOL ENGLISH

WRIST BLOOD PRESSURE MONITOR

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

Digital Blood Pressure Monitor. Model UA-767

Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement.

MEASURING VITAL SIGNS TRAINING CHECKLIST

Device Equivalence Evaluation Form

Measurement of Blood Pressure

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

Vasc Health Risk Manag. 2011; 7: Published online 2011 November 30. doi: /VHRM.S27193 PMCID: PMC

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

OEM MAXNIBP Frequently Asked Questions

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Important Safety Instructions

Integrating Sound Level Meter and Datalogger

Blood Pressure Assessment Program Screening Guidelines

INSTRUCTION MANUAL. 10 series Plus Blood Pressure Monitor with ComFit TM Cuff. Model BP791IT ESPAÑOL ENGLISH

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Temperature Humidity Meter

Forehead Thermometer INSTRUCTION MANUAL. Model MC-720

Device Equivalence Evaluation Form

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

RS DIGITAL THERMOMETER

Monitoring Blood Pressure

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

ENGLISH...3 DEUTSCH...13 FRANÇAIS...23 ESPAÑOL...33 ITALIANO...43 PORTUGUÊS...53

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

P R E S S U R E P O I N T S S E R I E S : Measuring your blood pressure at home

microlife PF 100 Electronic Asthma Monitor Instruction Manual (1-15) Moniteur d'asthme électronique Mode d'emploi (16-31) Monitor electrónico para el

Instant Ear Thermometer

VOICE RECORDER NOTE CORDER DP-211 INSTRUCTIONS. Register your product on and get additional benefits from Olympus!

Device Equivalence Evaluation Form

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

NFC Communication Tray Model: HHX-IT3-Z

IN-OUT Thermometer with Cable Free Sensor and Clock

Instant Ear Thermometer

Fox 40 Whistle Watch USER MANUAL

LG Wireless Remote Controller

INSTRUCTION MANUAL. IntelliSense Blood Pressure Monitor. ModelHEM-907XL. Thank you for purchasing the OMRON IntelliSense Blood Pressure Monitor.

April 3, Dear Autumn Liu,

12 Volt 30 Amp Digital Solar Charge Controller

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Pocket Tach 99 (PT99) Non-Contact Tachometer

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

a Centre de Médecine Cardiovasculaire, Paris, France and b Lebanese Received 7 June 2009 Revised 6 September 2009 Accepted 17 September 2009

Operating Instructions Air Conditioner

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

MEASURING AND RECORDING BLOOD PRESSURE

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Instructions and care

Ground Resistance Clamp On Tester

Manual Blood Pressure Measurement

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

User's Guide. Pinless Moisture Meter. Model MO257

HEART RATE + CALORIE MONITOR

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Accurate home blood pressure measurements with the WatchBP home A. Instruction Manual

RT-1261A Ear and Forehead Thermometer Owner s Manual

AM / FM Tuner + RDS. Model: TU

Blood pressure measurement devices. December 2013

Touchless Forehead Thermometer

AM/FM Portable Radio

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

The FreeStyle Lite Meter and How It Works

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Use and Care Manual. Model CPA12KH AIR CONDITIONER

body fat scale + Instruction Manual complete body analysis scale HEALTH

Thermistor Thermometer MODEL NO

Tympanic Thermometer

Coordinating Committee in Occupational Therapy, Hospital Authority

digital fever alert ear thermometer suitable from birth instruction manual

Circulation Stations

INVESTIGATING HEART RATE AND BLOOD PRESSURE

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

User Manual Color video door phone

DUCT TYPE AIR CONDITIONER

Important Safeguards

PD 100A. Printing data system

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

HIGH BLOOD PRESSURE AND YOUR KIDNEYS

GoFit Platinum Power Vibe

ihealth Wireless Blood Pressure Monitor (BP5) OWNER S MANUAL Table of Contents

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

Micro Wireless Electricity Monitor

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

English Español. 10 series Blood Pressure Monitor. Model BP786. Instruction Manual B

Welch Allyn Connex ProBP 3400 digital blood pressure device. Directions for use

Transcription:

CH607 mmhg English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH607 DATE mmhg TIME SET P SYS. M DIA. mmhg MODE START/STOP - Eng 1 - PULSE /MIN MEMORY English Español Português Deutsch

GENERAL REMARKS General remarks on blood pressure and blood pressure measurement If the cuff is to be deflated quickly, depress Start/ Stop switch. The attached cuff is suited for a wrist circumference of 13.5 cm to 19.5 cm. When attaching the cuff, the body of the blood pressure monitor should be placed on the inside of your wrist. Self-measurement is no therapy! In no case should the dosage of medication ordered by the doctor be changed. In preparation for blood pressure measurement, you should urinate and should remain relatively still for 10 to 15 minutes prior to measurement. Exercise, eating and drinking, smoking, etc., prior to measurement may affect the results. The blood pressure varies constantly throughout the day. Measurement should be made regularly at the same time each day. Do not be too impressed by the results of one measurement. Keep a record of blood pressure variations. Many readings tell a story. Emotional stress may tend to cause blood pressure to rise. This product should not be used to monitor cardiac arrhythmia. For proper measurement of blood pressure Take a deep breath five or six times and then relax before measuring blood pressure. If you are tense when taking the measurement, you will not get a valid reading Blood pressure will be elevated when you are in a worrisome or irritated state, suffering from lack of sleep or constipation, or after exercise or a meal. Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the wrist and tighten it so that one finger may be inserted between the cuff and wrist. Do NOT measure blood pressure after bathing or drinking. When you feel like relieving yourself, you should do so before measuring blood pressure. - Eng 2 -

English Español Português Italiano Deutch Français Measure blood pressure where the room temperature is about 20 C. DO NOT measure blood pressure when it is too cold (below 10 C)or too hot (above 40 C) in the room. DO NOT try to measure blood pressure immediately after drinking coffee or tea or smoking. Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk. DO NOT measure blood pressure after the cuff has been on for a few minutes, as your arm will have built up higher blood pressure, and you will not get a valid reading. Precaution for use If you suffer form heart disease, high blood pressure or other circulatory disease, please consult your doctor first. If you feel abnormal pressure of the cuff during use or any other irregularity, reduce the pressure by immediately switching off the power or removing the batteries and consult the sale outlet where you purchased. If you think the measured value is abnormal or if measuring makes you fell unwell, discontinue use and consult your doctor. Measurement of blood pressure may not be possible for someone with a weak pulse or arrhythmia. PRECAUTION FOR USE - Eng 3 - Congestion, swelling, etc. may occur in some people. If blood pressure is measured repeatedly, an accurate result will not be achieved. An interval of about 10 minutes should be allowed. The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data.

Precaution for maintenance Do NOT store the blood pressure meter where it will be exposed to direct sunlight, high temperature (over 60 C), low temperature (below - 20 C), high relative humidity (over 95%) or in a dusty place. Do NOT expose the blood pressure meter to undue force or vibration, or drop it. Remove the batteries when not use for a long time period. Do NOT disassemble the apparatus. Do NOT bend the cuff or Air hose unnecessarily. Never wipe the blood pressure monitor with thinner or benzene, as they may damage it. When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Cleaning method of Cuff After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it air dry. Hard rubbing or washing in a washing machine will cause air leakage. Also, be careful not to get water into the air hose. Protect the natural environment Please help protect the natural environment by respecting national and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. Nature and frequency of maintenance This product is designed for use over an extended period of time; however it is generally recommended that it be inspected every two years to ensure proper function and performance. - Eng 4 -

English Español Português Italiano Deutch Français WHO blood pressure classifications Standard for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart. SYSTOLIC (mmhg) 180 160 140 130 120 Hypertension (severe) Hypertension (moderate) Grade 1 Hypertension (mild) High-Normal Normal Optimal 80 85 90 100 110 DIASTOLIC (mmhg) Definition and Classification of Blood Pressure Lebels Reference European standard: This products complies with EN instructions 93/ 42/EEC (Medical Device Directive) and with the following standards: EN 1060:1995 Noninvasive Sphygmomanometers, Part 1 General Requirements and EN 1060: 1997 Noninvasive Sphygmomanometers, Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems. Manufacturer: Name: Living Science (Shenzhen) Co., Ltd. Address: Shun Mu Ku Road, Ping Hu County, Shenzhen, Long-Kang Town, China European Representative: Name: Innovative business promotion GmbH. Address: Huttenstraße 4 D-07743 Jena Note: When a patient s systolic and diastolic blood pressure fall into different categories, the higher category should apply. - Eng 5 -

DATE P DEVICE DESCRIPTION 1. Name of the parts LCD display mmhg CH607 M SYS. mmhg TIME SET Setting button Wrist cuff START/ STOP PULSE /MIN DIA. mmhg MEMORY MODE Mode button Recall memory button Start/Stop button Batteries AAA 1.5V 2 Carrying case - Eng 6 -

English Español Português Italiano Deutch Français 2. Description of display symbols Month Date Hour Minute Measuring pressure symbol Blood pressure unit Battery weak display Error symbol Memory record Afternoon time Systolic rate Diastolic rate Pulse rate Pulse symbol - Eng 7 -

BATTERY REPLACEMENT 1. To use this unit, you must install batteries, If the battery mark is displayed, you must change both batteries. 2. Open battery cover as illustrated. Replace the two batteries, matching the (+) and ( ) polarities on each battery with the polarity marks on the case. To take the batteries out easily, pull the transparent ribbon. 3. LR03 batteries or equivalent are suitable for this blood pressure monitor. All batteries used must be same type. Do not mix alkaline, standard (carbon-zinc) or rechargeable (cadmium) batteries. Also, do not mix old and new batteries. CLOCK MODE 1. Default time indicating state and selection of each mode When the battery is installed, the time and date are set as follows. January 1, 12:00:00 AM 2. Setting Date and Time 1) Press the Mode switch then Month starts flashing and press SET button to set the correct month. (Each time the Set switch is pressed, the value of the month is increased - Eng 8 -

English Español Português Italiano Deutch Français by one. The value of minute can be corrected in only the forward direction.) 2) Press the Mode switch then Date starts flashing. Press SET button to set the correct date. (Each time the Set switch is pressed, the value of the date is increased by one. The value of hour can be corrected in only the forward direction.) 3) Press the Mode switch then Hour starts flashing. Press SET button to set the correct date. (Each time the Set switch is pressed, the value of the Hour is increased by one. The value of hour can be corrected in only the forward direction.) 4) Press the Mode switch then Minute starts flashing. Press SET button to set the correct Minute. (Each time the Set switch is pressed, the value of the minute is increased by one. The value of Minute can be corrected in 12-hour format in only the forward direction.) 5) Press the mode switch to finish correction. 1. Attaching of wrist cuff MEASUREMENT PROCEDURES The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary. The pressure cuff has integrated into the wristlet. Wind the wristlet around your left wrist. The wrist should be free. The display is at the inner of the wrist. - Eng 9 -

Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately, it may display an error or abnormal values. Pull the wristlet tight and close the Burr closure. Wrist circumference: 13.5-19.5 cm. Measurement Procedures for People With a Weak Pulse Apply the middle part of the wrist cuff to the artery in the wrist to measure blood pressure. 2. To start the Measurement CAUTION Do not grasp the unit too tightly. Keep your left wrist relaxed during measurement period. Do not apply physical pressure against unit with wrist before or during measurement. All measurements must be performed while you are seated and with your left hand on a table held a level with your heart. Keep your body still and relaxed during measurement. 1) Press the Start/Stop switch. All display marks appear for approx. 1 second. All displays disappear and the time is updated. 2) The blood pressure measuring symbol will appear on the display and then the air pressure will automatically pump up to 195mmHg. 3) If blood pressure tends to be on the high level, the air pressure will automatically increase again to the required level for measurement. - Eng 10 -

English Español Português Italiano Deutch Français Do not move or talk while taking the blood pressure measurement. 4) When pressurization is completed, the automatic air release system will gradually reduce cuff pressure, and measuring mark Heartmark will flash on the display indication that measuring is in progress. 5) After taking blood pressure measurement, the systolic and diastolic pressure with pulse rate is displayed on the display for 1 minute. 6) Unless an error is generated, the measurement results are automatically stored in memory. Up to 99 sets of results can be stored in memory. * When there are already 99 sets of results in memory, the oldest one is automatically erased and overwritten with the newest. Display of the measurement result will continue until power is turned off. CAUTION To discontinue a measurement for any reason, press the START/STOP switch. This causes the wrist cuff to deflate rapidly. 3. Turn Power off When the Start/Stop switch is pressed, the display will be changed over to the date/watch only indication and the power will be totally turned off approximately one minute later. 4. Automatic power-off function If the unit is left on after measurement, an automatic power-off function turns the power off after approximately 1 minute. To continue measurement, press the START/STOP switch turning the unit on. After, wind the wristlet around your left wrist. - Eng 11 -

5. Memory recall You can recall stored data by pressing the Memory switch, except when performing a measurement. Up to 99 sets of measurement results are automatically stored in memory, and memory cell No. 1 is always used to store the oldest set of results. Press Memory switch, the memory cell number with the stored measurement results (Systolic / Diastolic and Pulse with Date/Time) are displayed for 1 minute. * Pressing Memory button, nothing will appear on the display if there is no data in the memory. If the Memory switch is pressed further, the old date are indicated in the order of the time series. Press Start/Stop switch to turn off the unit. 6. Memory clear function To clear memory data, take out the two batteries at same time and then press the START/STOP switch for a while. All memory is erased. Press the POWER/START switch to turn off. CAUTION To discontinue a measurement for any reason, press the POWER/START switch. This causes the wrist cuff to deflate rapidly. - Eng 12 -

English Español Português Italiano Deutch Français ERROR DESCRIPTION OF DISPLAY MARKS DISPLAY MARK CONDITION / CAUSE CORRECTIVE ACTION Measuring Error Mark appears in the measurement condition and flashes when pulse is detected. Appears when the accurate blood pressure could not be obtained accurately. Measurement in progress. Remain still. Press Start/Stop switch again and re-measure. Or check cuff if wrapped at the wrist or according to instructions. Check palm if exerting effort. Check if talking or moving during measurement. Check if posture is incorrect. Replace batteries Appears when the battery voltage is excessively low or the positions of batteries are incorrect. Replace all batteries with new ones. Insert the batteries at paying close attention to the +/ directions. Measuring blood pressure symbol Appears all the time until the measurement is completed. - Eng 13 -

Model Number Measuring Principle Measurement Localization Cuff Arm Circumference Range Measurement Range Accuracy LCD Indication LCD Switch Inflation Deflation Exhaust Rated Voltage Power Source Power Consumption Battery Life Automatic Power Off Function Clock Function Memory Function Dimensions Weight Operating Environment Storage Environment Accessories SPECIFICATIONS CH607 Oscillometric System Left Wrist Arm Preformed cuff 13.5 to 19.5 cm Pressure 0-300 mmhg Pulse 40-199 Pulse / Min. Pressure ±3mmHg Pulse ±5% of reading Pressure Systolic Blood Pressure: 3 digits Diastolic Blood Pressure: 3 digits Alternatively Pulse Pulse Rate: 3 digits Measuring Marks Exhaust Re-Measure Battery Viewing Size 38.0(H) 32.0(W) mm Digit Size 9.5(H) 5.0(W) mm 4-switches (Start/Stop, Memory, Set, Mode) Automatic Inflation by Air Pump Automatic Air release control valve Quick Exhaust Valve 3 V DC 2 AAA Size Batteries 0.1 W Approx. 250 times measurement Approx. 3 min. (after activated) ±20 Seconds a month, Full Automatic Calendar, Alarm 99 Memory (Date, Time, Blood pressure value, Pulse) 72(W) 70(D) 29(H)mm Approx. 140g including batteries. Temperature 10 to 40 C Humidity 30 to 85%RH Temperature 20 to 50 C Humidity 10 to 95%RH 2 AAA batteries, Instruction manual and Carrying case * Specifications and design may be changed without any notice in the event of improvementsbeing made. - Eng 14 -