Uninterruptible Power Supply

Similar documents
How To Use A Power Supply Unit (Upu)

User s Manual AURORA 1.2K/2.2K

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Powerware 5110 UPS User s manual

Online UPS. PowerWalker VFI 1000R/1U

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Installation and Operation Back-UPS 1250, 1300, 1500

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

User Manual 1K/2K/3K Online UPS

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

EKOS Cart. Instructions for Use

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

350, 500, 650 and 1000 MODELS

Uninterruptible Power Supply

Back-UPS Pro 1300/1500 Installation and Operation

USER MANUAL Online UPS 1K/2K/3K Rack

USER MANUAL Online UPS 1K/2K/3K

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

3000W Power Inverter

User s Manual Before using the inverter, you need to read and save the safety instructions.

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

HP UPS R1500 Generation 3

Dehumidifier Users manual. For Models: DH45S DH65S

How To Use A Power Supply Unit (Upland)

Model #: SMART2200CRMXL

10000HXL31/15000HXL31/20000HXL31

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

User Manual HomeGrid 3000 Solar Generator

SPL 2-00/-01 OPERATION INSTRUCTIONS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

UPS-2200R-HH/UPS-2200R-HHIP

VLT Series 300 Watt True Sine Wave Inverter

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

750VA/1000VA/1500VA 100/120/230VAC 2U

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Home Solar Kit Owner s Manual. Model: HS

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

BC Pro UPS System Standby UPS System

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

=============================== WARNING

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

12 Volt 30 Amp Digital Solar Charge Controller

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

Internet Office UPS System Standby UPS for PCs, workstations and more

UPS VA User s Manual

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

BITMAIN. APW PSU Series User Guide

Home Solar Kit Owner s Manual. Model: HS

Residential Gateway (RG) Battery Backup REV B

Installation and Operating Instructions (for chargers shown below)

Advantium 2 Plus Alarm

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

esata External Storage

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC VA Rack-mount 2U 120/208/230 VAC

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

NeTYS PR VA

Installation and Operating Instructions (for chargers shown below)

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

BroadBand PowerShield. User Manual

Table Of Contents

TIG INVERTER INSTRUCTION MANUAL

Digital Photo Picture Frame. Operation Manual

400 Amp Rechargeable Jump Start System RAC-HP082

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

User Manual (English)

Transcription:

SBP-TBF UPS Series P.N.16002100 Rev.03/15 Uninterruptible Power Supply USER'S GUIDE 1000VA, 1400VA, 2000VA Models: SBP1000U-TBF, SBP1400U-TBF, SBP2000U-TBF, SBP1000U-TBF-LR, SBP1400U-TBF-LR SmartPower SYSTEMS A POWER QUALITY COMPANY

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models SBP1000TBF - SBP1400TBF and SBP2000-TBF that should be followed during installation and maintenance of the UPS and batteries. Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well as violate local electrical codes. In the event of an emergency, turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, lifesupport equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. CAUTION To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI/NFPA 70. The socket-outlet shall be installed near the equipment and shall be easily accessible. 1

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1). Remove watches, rings, or other metal objects from the hand. 2). Use tools with insulated handles. 3). Wear rubber gloves and boots. 4). Do not lay tools or metal parts on the top of batteries. 5). Disconnect charging source prior to connecting or disconnecting batteries terminal. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries When replacing batteries, replace with the same number of the sealed lead-acid batteries. 2

+ - 3.System Description Front Panel LED 1. Fault LED 2. AC Mode: Load Level LEDs Backup Mode: Battery Capacity LEDs 3. AC Mode: Green Lighting Backup Mode: Green Flashing 4. Power ON/OFF Switch Back Panel 1. USB Port (Option) 2. Cooling Fan 3. Modem/Phone/Network Line Surge Protection 4. Circuit Breaker 5. AC Output 6. AC Input SBP1400TBF / SBP2000TBF SBP1000TBF SBP1000TBF-LR / SBP1400TBF-LR 3

+- Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware the Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase - (RMA) Please inform the transport agency immediately should you find signs of damage.) (Please keep the packaging in a safe place for future use. 2. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 8 inches to avoid interference. 8 inches 3. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours. UTBF 4

4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). UTBF UPS COMPUTER 5. Modem/Phone line Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket as shown. Incoming Internet line UTBF 5

+ - 6. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the serial cable as per diagram below. UTBF UPS COMPUTER 7. Turn On/Off The UPS will be turned on automatically at first plug-in. At this moment, press the power switch lightly to turn off the UPS. To turn on the UPS again, just simply press power switch again. Please DO NOT punch it to extend the life of the power switch. 8. DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. 9. Green Power Function All UPS are equipped with Green Power function. If no load connects to the UPS, it will automatically shut down in 5 minutes for energy saving while power failure. The UPS will restart while AC recovery. 6

10. Battery Removal (SBP1000) Before replacing the battery, turn off the UPS and unplug the UPS cord from the wall outlet. Follow Chart 4 to remove the screw located on the bottom of the front panel and then open the front cover. Remove the front panel Remove the battery cover Chart 4 Chart 5 After removing battery cover (Chart 5), gently extract the battery by pulling attached white vinyl sheet (Chart 6). Disconnect the wires connected to the battery. Be sure to replace the same type of batteries and dispose of old batteries properly at an appropriate recycling facility. Chart 6 7

Free Software Download SmartPower Systems provides a complete line of software solutions for standalone and networked computers, including SNMP support. POWER MANAGEMENT SOFTWARE TM FEATURES Automatic Save and Shutdown for unattended PCs Reboot/Shutdown scheduling Self test scheduling Power condition analysis Online display of input / output voltage and frequency, battery capacity and load level Dashboard interface Send on-line commands to UPS such as Test, Shutdown, Sleep and restart Extensive logging of all UPS operation and power quality data Event & date analysis Events and data bar charts presentation Graphical display of power quality Run in background even before user login Supports: Windows XP/ME/7/NT/2000/2003 UPSwing Pro is also available for SCO UNIX, Sun Solaris, LINUX, FreeBSD and Windows with Networking capability. Downloading UPSWING from the internet is a simple process: 1. Go to www.smartpowersystems.com/downloads/setup.exe 2. Double click on the Setup.exe file and follow instructions. For Network support version contact us at support@smartpowersystems.com 8

Trouble Shooting Symptom Possible Cause Remedy No LED display on the front panel Alarm buzzer beeps continuously when AC supply is normal When AC power fails, back-up time is shorten. Communication lost between UPS and computer. 1. Missing battery 2. Battery defect 3. Power switch is not pressed at least 5 seconds. Overload of the UPS 1. Overload of the UPS 2. Battery voltage is too low 3. Battery defect due to high temperature operation environment, or improper operation to battery 1. Software is not installed correctly 2. Cable is not properly connected 1. Charge battery up to 10 hours 2. Replace with the same type of battery 3. Press power switch for at least 5 seconds Verify that the load matches the UPS capability specified in the specs. 1. Remove some non-critical load 2. Charge battery 10 hours or more 3. Replace with the same type of battery 1. Check the setting of the software 2. Check to see that the USB cable is firmly connected to the computer and confirm the setting again Mains normal but the UPS is not working. 1. Circuit breaker is tripped 2. Power cord is loose 1. Reset the circuit breaker 2. Reconnect the power cord properly If abnormal situations occur that are not listed above, please call customer service immediately. 9

Specifications SBP1000U-TBF SBP1000U-TBF-LR SBP1400U-TBF SBP1400U-TBF-LR SBP2000U-TBF OUTPUT Capacity VA / W Voltage (on battery) Frequency (on battery) Voltage Regulation (AVR) Transfer Time INPUT Voltage Frequency PROTECTION Spike Protection Lowest Pass through Voltage Overload 1000 / 600 1400 / 840 2000 / 1200 Simulated sine wave at 120V ±10% 50 or 60Hz ±1% AVR automatically increases output voltage 17% above input voltage if -9% to -25% of nominal. AVR decreases output voltage 15% below input voltage if +9% to +25% of nominal 4-8 milli seconds, including detection time 89-145VAC 50 or 60Hz±1% (auto sensing) 1270 Joules <10V Normal Mode <0.5V Common Mode UPS automatic shutdown if overload exceeds: 1) Line mode: 110% of nominal at 5 minutes, 120% immediately 2) Battery mode: 110% of nominal at 10 seconds, 120% immediately Unit Input Tel / Fax / Modem / DSL / Network BATTERY Short Circuit Battery Type Typical Recharge Time Protection Back-up Time (Minutes) Half Load PHYSICAL Net Weight (Lbs. / Kg.) Shipping Weight (Lbs. / Kg.) Dimensions D x W x H In. (mm) Input Inlet Receptacles INDICATORS AC Mode Backup Mode Fault AUDIBLE ALARM Backup Mode Low Battery Overload Fault Battery Replace INTERFACE UPSWING for Windows Optional Software CONFORMANCE Safety Warranty ENVIRONMENT Ambient Operation Audible Noise Circuit breaker for overload & short circuit protection RJ11/45 UPS output cuts off immediately or input circuit breaker protection Sealed, maintenance-free lead acid 10 hours (to 90% of full capacity) after complete discharge Automatic self-test & discharge protection, replace battery indicator 25.25 / 11.5 26.85 / 12.18 28.35 / 12.86 15.70 x 5.70 x 8.07 (399 x 145 x 205) AC cord (5-15P) CL5-15P AC cord (5-15P) CL5-15P AC cord (5-15P) 6-NEMA 5-15R UPS 2-NEMA L5-15R 6-NEMA 5-15R UPS 2-NEMA L5-15R 6-NEMA 5-15R UPS 220/230/240V models available. Consult factory for specifications and features. Specifications and features subject to change without notice. 12 9 6 22.80 / 10.4 24.86 / 11.28 26.36 / 11.96 The 1st. green LED lighting, and the 2nd. to 5th. green LED gradually lighting indicating load level 1 The 1st. green LED flashing, and the 2nd. to 5th. green LED gradually lighting indicating battery capacity <40 dba (1 meter from surface) (AC model) <45 dba (DC model) 10 Red LED lighting Beeps every 10 seconds Beeps every second Beeps every 0.5 seconds Continuously Beeps Beeps every 2 seconds USB Software detects power failure, battery low, schedule UPS on/off, AC power status display, bat / load level display UPSWING PRO for SCO UNIX, Sun Solaris, LINUX, FreeBSD and Windows with Networking capability cul, UL Two years for the SBP unit. Four years pro-rated battery warranty. $25,000 Lifetime Connected Equipment Protection Warranty 0-90% humidity non-condensing 0-40 deg C

LIMITED PRODUCT WARRANTY We warrant this product to be free from defects in material and workmanship for 2 years. The battery has a 2 year warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product. Visit our website for details - www.smartpowersystems.com CONNECTED EQUIPMENT PROTECTION POLICY If the Smart Power Systems equipment fails and this failure causes the surges to pass through and damage the connected equipment, Smart Power Systems will pay for the repair or replacement of the connected equipment up to $25,000 in accordance to the Connected Equipment Protection Policy. Visit our website for details - www.smartpowersystems.com/claim.htm In order to validate your Connected Equipment Warranty, you MUST complete the warranty registration card provided and mail it within 20 days of purchasing the unit. You can also register online at www.smartpowersystems.com/warranty.htm IMPORTANT If for any reason you need to return the unit to the manufacturer, you should obtain an RMA (Return Material Authorization) number before returning the unit. To request an RMA number please call 1-800-772-7633 or visit the website at www.smartpowersystems.com/rma.htm 11

SmartPower SYSTEMS A POWER QUALITY COMPANY 1760 Stebbins Dr. Houston, TX 77043 1-800-882-8285 www.smartpowersystems.com Email:support@smartpowersystems.com