Amplivox Audiometric Products

Similar documents
MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

GSI AUDIOSTAR PRO. Free Call: CLINICAL TWO-CHANNEL AUDIOMETER. Australian Distributer:

Product Line for Hearing Screening & Diagnostics

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

MA 25 Operating Manual

Operating Instructions MA 27

PROFESSIONAL BOARD FOR SPEECH, LANGUAGE AND HEARING PROFESSIONS STANDARDS OF PRACTICE IN AUDIOLOGY

The Accuracy of 0 db HL as an Assumption of Normal Hearing

Audiometric (Hearing) Screening September November 2013

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

Audio Examination. Place of Exam:

Main features * : Internal database > 1000 tests. Suprathreshold tests. High frequency. Musical frequencies. Automatic masking.

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Guideline for diagnosing occupational noise-induced hearing loss. Part 3: Audiometric standards

MA 41 Operating Instructions

HEARING MEASUREMENT 8.1. INTRODUCTION (RATIONALE FOR AUDIOMETRY)

Guidelines on Hearing Checks and Audiometry Under the Safety, Health and Welfare at Work (General Application) Regulations 2007, Control of Noise at

DAILY BIOLOGIC CHECK OF AUDIOMETERS

PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

Hearing Test Results from 2009 Audio Engineering Society Convention Testing funded by Shure

THE LEADING AUDIOLOGY CLINIC MANAGEMENT SYSTEM

Practice Standards for Hearing Service Providers

A PROFESSIONAL PRACTICE PROFILE

Guidelines for Manual Pure-Tone Threshold Audiometry

PURE TONE AUDIOMETER

Hearing Protection Standard OSHA Standard 29 CFR

Operating Instructions MAICO MA 52

Manual Pure-Tone Threshold Audiometry

OAK GROVE SCHOOL DISTRICT. Hearing Conservation Program

NEW YORK STATE MEDICAID PROGRAM HEARING AID/ AUDIOLOGY SERVICES FEE SCHEDULE

3M E-A-RTONE 3A and 5A Audiometric Insert Earphones

SCHOOL-BASED REHABILITATIVE AND RBHS SERVICE RATES (With Interim PRS Rates) Revised 4/16/15 Description Code Modifiers Reimbursement Rates AUDIOLOGY

Step-by-Step RECD Guide

NEW YORK STATE MEDICAID PROGRAM HEARING AID/ AUDIOLOGY SERVICES PROCEDURE CODES

Hearing Screening Protocol for School Aged Children

HEARING SCREENING FOR CHILDREN

Once your baby has good head control and can turn towards something interesting, a more advanced behavioural procedure can be used.

S-822. Noise and Hearing Conservation RISK MANAGEMENT

GUIDELINES ON THE ACOUSTICS OF SOUND FIELD AUDIOMETRY IN CLINICAL AUDIOLOGICAL APPLICATIONS

CHAPTER 30. MEDICAL PROVIDERS-FEE FOR SERVICE SUBCHAPTER 5. INDIVIDUAL PROVIDERS AND SPECIALTIES PART 103

California State University, Fresno Department of Communicative Disorders and Deaf Studies CDDS 128. Observations in Audiology

A Professional Practice Profile for Hearing Health Professionals

SAMPSON COMMUNITY COLLEGE

Western University. Hearing Protection Program. Prepared by: Occupational Health and Safety

Sample Written Program. For HEARING CONSERVATION

Hearing Conservation Program

Audiometer Calibration System

Stanford University. Hearing Conservation Program

Hearing Devices Policy and Administration Manual

UC Santa Barbara Hearing Conservation Program Manual

UKAS Technical/Peer Assessor Keyword List AUDIOLOGY

HEARING SCREENING: PURE TONE AUDIOMETRY

The Role of the Educational Audiologist Introduction:

REGULATIONS FOR THE DEGREE OF MASTER OF SCIENCE IN AUDIOLOGY (MSc[Audiology])

Note you MUST be certified at the time of the class to attend the recertification

NEW YORK STATE MEDICAID PROGRAM HEARING AID/AUDIOLOGY MANUAL

Program No Section Heading Page # 6.0 Monitoring Training Audiometric Testing Noise Exposure Control 6

Operating Instructions Detective Audiometer

Hearing Tests And Your Child

UCSC HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) August 2007

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

Environmental Health and Safety* 2809 Daley Drive * Ames, Iowa * (515) *

Occupational Noise Exposure Requirements

29 CFR 1910 OSHA GENERAL INDUSTRY REGULATIONS

Hearing Tests And Your Child

Audiometer Calibration System Manual

Who are you? Six Components of Hearing Conservation Program. Hearing is Precious!

Recommended Procedure. Pure-tone air-conduction and bone-conduction threshold audiometry with and without masking

PAT Tester Printers and Barcode Scanners

Official CPT Description

BASIC SOUND LEVEL METERS

Quick Start Guide Olympus WS-110 Digital Recorder

Pure Tone Hearing Screening in Schools: Revised Notes on Main Video. IMPORTANT: A hearing screening does not diagnose a hearing loss.

Questions and Answers for Parents

hospital facility for the ophthalmologist for the examining room charge per patient per date of service. MISC DRUGS AND MED SUPPLIES, ADMIN STAT

CHAPTER 11 NOISE AND HEARING CONSERVATION PROGRAM

PRACTICE STANDARDS AND GUIDELINES FOR HEARING ASSESSMENT OF ADULTS BY AUDIOLOGISTS

Pediatric Whitepaper. Electrophysiological Threshold Estimation and Infant Hearing Instrument Fitting

Introduction Noise and Occupational Hearing Loss

highlight some of the problems a deafblind or sensory impaired person might have in getting tested;

Cisco Unified IP Phone Solutions

Paediatric Hearing Assessment

NEW YORK STATE MEDICAID PROGRAM HEARING AID/ AUDIOLOGY SERVICES POLICY GUIDELINES

instruction guide Version 2.2 Table of contents

Behavioural Audiometry for Infants and Young Children Whose hearing loss has been detected in infancy

Hearing Aids - Adult HEARING AIDS - ADULT HS-159. Policy Number: HS-159. Original Effective Date: 3/18/2010. Revised Date(s): 3/18/2011; 3/1/2012

Transcription:

Amplivox Audiometric Products 1 Diagnostic Audiometers Amplivox 270 A diagnostic audiometer that excels in the critical areas of technology, ergonomics and ease of use. Test results can be saved in memory for review at a later stage, printed with optional printer or exported via the NOAH (2&3) compatible interface. The Amplivox 270 has the flexibility to be used for both clinic and portable applications. Amplivox 260 Incorporates a comprehensive range of air conduction, bone conduction and speech test audiometry functions which make it the ideal choice for conducting diagnostic audiometry. Weighing just 715g, this audiometer meets all portable requirements. It also comes with the unique facility of optional internal battery power, NOAH (2&3) and printer connectivity and can utilize both TDH39/49 and insert earphone outputs. Amplivox 240 An inexpensive diagnostic audiometer which facilitates both air conduction and bone conduction measurements. It is the ideal instrument for professionals who require a totally portable audiometer as it is both lightweight and has the unique facility of optional internal battery power and NOAH connectivity (2&3). These audiometers should be of considerable interest to the hospital, audiology and hearing aid departments, private audiologists and ENT markets where there is a mobile requirement.

2 Screening Audiometers (Air conduction only) 2.1 Manual screening audiometers Amplivox 116 A manual screening audiometer which is extremely reliable and very easy to operate. Compact and lightweight (just 655g), the model 116 is totally portable using either the supplied mains adaptor or the optional battery power function. Reduced test times and improved concentration levels are made possible with the threshold retention function. The model 116 has met the audiometric requirements of numerous primary care, community and manufacturing organisations. Amplivox 160 The Amplivox 160 is designed to improve results recording by producing an archive quality audiogram when used with the specified portable thermal printer. It offers a comprehensive air conduction threshold facility at a cost-effective price. It is lightweight and compact, is totally portable and is ideal for both desktop and mobile use using either the mains adaptor or the optional battery power function. These audiometers are ideal for school nurses, primary care groups, GP surgeries and industry.

2.2 Automatic screening audiometers Amplivox 170 A low cost screening audiometer offering both automatic and manual audiometry. Results can be printed with the optional designated printer, saved in memory for future use, recorded manually or transferred to a PC installed with Amplivox Audibase software. Lightweight and compact, the Amplivox 170 is totally portable and is ideal for both desktop and mobile needs. Amplivox PC850 An automatic audiometer that integrates with a PC to provide a comprehensive and pro-active audiometric facility. The product has a user definable recall facility and extensive data analysis features that enable at risk individuals and user defined groups to be identified and monitored. The Amplivox PC850 is a cost effective solution for the provision, storage and management analysis of audiometric test results. CA850 Series 4 Audiometer Designed for use in occupational workplace health environments, the CA850/4 will automatically measure, evaluate and categorise hearing threshold levels in a very efficient and cost effective manner. The Amplivox CA850 Series 4 audiometer is very easy to use with the operation built around one key. Test results are displayed on the large integral display as an actual audiogram. The results can be saved as (1) archive quality printout, (2) held in memory (up to 1000 audiograms) and/or (3) transferred to a computer. The instrument is also compact and lightweight, features which will be of benefit if there is a mobile requirement. These audiometers should be of significant interest to occupational health/work place health departments of commercial, public sector and military organisation who are required to test a large number of patients as part of a hearing conservation program.

3 Tympanometers/impedance products Amplivox Otowave 102-1 & 102-4 Elegantly shaped to follow the contours of a hand and with a perfect weight distribution, fast middle ear measurements can be completed with accuracy and confidence. The Amplivox Otowave is totally portable and weighs just 380g (including batteries). Tympanometry and reflex results are easily reviewed on the large highresolution display and can be printed, stored within internal memory (with patient identification and test date and/or transferred to a PC with a NOAH database without the need to connect data cables to the otowave tympanometer

4 Audiocups Noise reducing headset enclosures which offer the following benefits:- Permit accurate pure tone audiometry in conditions of ambient noise too high for unshielded earphones. Can be fitted easily to any audiometer earphone using standard TDH39/49 inserts. Complete freedom from threshold shift no change in audiometer calibration at time of fitting. Subsequent periodic recalibration can be effected on standard ISO 6cc coupler without removal of inserts from Audiocups. Invaluable where a silent cabin or soundproof room is not available. Give extra attenuation when a booth is available