3500/42E Vibration Monitor

Similar documents
3500/40M Proximitor* Monitor

3500/62 Process Variable Monitor

3500/25 Enhanced Keyphasor*Module

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/93 System Display

1900/65A General Purpose Equipment Monitor

1900/65A General Purpose Equipment Monitor

3500/22M Transient Data Interface

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

1701/22 FieldMonitor Management Interface Module

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Low Frequency Velocity Sensor

and Accelerometers

Proximity Transmitters and Seismic Vibration Transmitters

SKF Machine Condition Transmitters (MCT) Series

Dynamic Pressure Charge Amplifier

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

VIBROCONTROL Sensitive Machine Monitoring

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Velomitor Piezo-velocity Sensor

9000 Series Accelerometers Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Electronic Control Devices The European Product Catalogue 2007

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Unidirectional Transmitter/ Receiver Units Introduction

NI USB-5681 RF Power Meter Specifications

R&S ZNC Vector Network Analyzer Specifications

Indoor / Outdoor Antenna

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Analog Servo Drive 25A8

Preset Counter signo 721

Adjustment functions for both span and shift have been incorporated

Safety technique. Emergency stop module BO 5988 safemaster

R&S ZNBT8 Vector Network Analyzer Specifications

CompactLogix Power Supplies Specifications

Features, Benefits, and Operation

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

R&S ZVA Vector Network Analyzer Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Absolute Rotary Encoder E6CP

Measurement Types in Machinery Monitoring

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

IMR 6000/10../20../30

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Rosemount 333 HART Tri-Loop

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

Small, Low Power, 3-Axis ±3 g Accelerometer ADXL335

L5354 ControlNet Communications Interface

Digital Pressure Measuring Instrument MDR480

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

Original instructions Tina 3A/Aps Adaptor unit

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Impedance 50 (75 connectors via adapters)

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Tina 2A/B Adaptor unit

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Duct Humidity Transmitter

FREJA 300 Relay Testing System

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

USER MANUAL V5.0 ST100

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CAN REMOTE I/O module. base device GEL 89100

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

- 1 - Eddy Current. Eddy current distance and displacement transducer

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Contents. Safety Warnings... 1

Chassis, Power Supply, and Element Management

Permissible ambient temperature Operation Storage, transport

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Thyristor-controlled power supplies and battery chargers

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Physical Specifications (Custom design available.)

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

SEISMIC VELOCITY TRANSDUCER T1-40

Model: DC-A2IO Advanced HVAC Controller

Rosemount 333 HART Tri-Loop

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

HIGH RELIABILITY POWER SUPPLY TESTING

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Allen-Bradley/Rockwell

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Bristol ControlWave Redundant Control

Power Supplies 3. SDN-P DIN Rail Series

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

NX safety stand-alone

Installation and User Guide

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Transcription:

3500/42E Vibration Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/42E Vibration Monitor is a 4-channel monitor that accepts input from proximity and seismic transducers, conditions the signal to provide various vibration and position measurements, and compares the conditioned signals with user-programmable alarms. The user can program each channel of the 3500/42E using the 3500 Rack Configuration Software to perform any of the following functions: Radial Vibration Thrust Position Differential Expansion Shaft Absolute Eccentricity Acceleration Velocity 3500 ENCORE series is available in two configurations: 3500 ENCORE Rack Upgrade: In this configuration the 3500/42E is installed as part of a 3500 ENCORE upgrade of a 3300 Monitor System where the 3300 chassis and IO remain in place. When used in a rack upgrade the monitor is limited to two channels and uses the pre-existing 3300 series IO Module and the relays located on the 3300 series IO. 3500 ENCORE System: In this configuration there will be a 3500 ENCORE System Rack with 3500 ENCORE IO modules. 3500/42Es that are used in a 3500 ENCORE rack have all four channels available. Monitor channels are programmed in pairs and can perform up to two of the monitoring functions at a time. Channels 1 and 2 can perform one function, while channels 3 and 4 perform another (or the same) function. Monitors in 3500 ENCORE Systems use a logic programmable Relay Module to drive alarm relays. The primary purpose of the 3500/42E monitor is to provide: 1. Machinery protection by continuously comparing monitored parameters against configured alarm setpoints to drive alarms. 2. Essential machine information for both operations and maintenance personnel. Each channel, depending on configuration, typically conditions its input signal to generate various parameters called static values. The user can configure Alert setpoints for each active static value and Danger setpoints for any two of the active static values. Page 1 of 10

Specifications Inputs Signal Input Impedance Power Consumption Sensitivity Radial Vibration Thrust Eccentricity Differential Expansion Acceleration Velocity Accepts from 1 to 4 proximity, velocity or acceleration transducer signals. 10 kω (Proximitor and Acceleration Inputs). 6.8W Typical 3.94 mv/µm (100 mv/mil), or 7.87 mv/µm (200 mv/mil). 3.94 mv/µm (100 mv/mil), or 7.87 mv/µm (200 mv/mil). 3.94 mv/µm (100 mv/mil), or 7.87 mv/µm (200 mv/mil). 0.394 mv/µm (10 mv/mil), or 0.787 mv/µm (20 mv/mil). 10 mv/(m/s 2 ) (100 mv/g). 20 mv/(mm/s) pk (500 mv/(in/s) pk), or 5.8 mv/(mm/s) pk (145 mv/(in/s) pk), or 4 mv/(mm/s) pk (100 mv/(in/s) pk). Outputs Front Panel LEDs OK LED DANGER LED ALERT LED Bypass LED Buffered Transducer Outputs Output Impedance Relay Contacts Transducer Power Supply Recorder Indicates when the 3500/42E is operating properly. Indicates the 3500/42E has detected a danger condition and is driving the danger alarm. Indicates the 3500/42E has detected an Alert condition and is driving the alert alarm. Indicates when the 3500/42E is in Bypass Mode. The front of each monitor has one coaxial connector for each channel. Each connector is short-circuit protected. 499 Ω In the case of a 3500 ENCORE Rack Upgrade, the 3500/42E will drive the relays for the various 3300 SIRM options. -24 Vdc +4 to +20 ma. Values are proportional to monitor full-scale. The monitor provides individual recorder values for each channel. Monitor operation is unaffected by short circuits on recorder outputs. Page 2 of 10

Voltage Compliance (current output) Resolution 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω. 0.3662 µa per bit Signal Conditioning ±0.25% error at room temperature ±0.7% error over temperature range. Update rate 100 ms or less. Note: Specified at +25 ºC (+77 ºF) unless otherwise noted. Radial Vibration Frequency Response Direct filter User-programmable, single-pole, -3db at 4 Hz to 4000 Hz or 1 Hz to 600 Hz, ± 1% accuracy. Gap filter Not 1X filter Smax 1X and 2X Vector filter Direct and Gap -3 db at 0.09 Hz. 60 cpm to 15.8 times running speed. Constant Q notch filter. Minimum rejection in stopband of -34.9 db. 0.125 to 15.8 times running speed. Constant Q Filter. Minimum rejection in stopband of -57.7 db. Note: 1X & 2X Vector, Not 1X, and Smax parameters are valid for machine speeds of 60 cpm to 60,000 cpm. Exclusive of filtering, within ±0.33% of full-scale typical, ±1% maximum. 1X and 2X Smax Not 1X Thrust and Differential Expansion Frequency Response Direct filter Gap filter Eccentricity Frequency Response Direct filter Gap filter Acceleration II Frequency Response Bias filter Not OK filter Within ±0.33% of full-scale typical, ±1% maximum. Within ±5% maximum. ±3% for machine speeds less than 30,000 cpm. ±8.5% for machine speeds greater than 30,000 cpm. -3 db at 1.2 Hz. -3 db at 0.41 Hz. Within ±0.33% of full-scale typical, ±1% maximum. -3 db at 15.6 Hz. -3 db at 0.41 Hz. Within ±0.33% of full-scale typical, ±1% maximum. -3 db at 0.01 Hz -3 db at 2400 Hz Page 3 of 10

1X and 2X Vector filter Valid for machine speeds of 60 cpm to 100,000 cpm. The following table represents the frequency ranges for the 3500/42E under different options using the Acceleration II Channel Type. Output Without Filter, Low- With Integration Type or High-Pass Filter RMS 10 to 30,000 Hz 10 to 20,000 Hz Peak 3 to 30,000 Hz 10 to 20,000 Hz Filter Quality High-Pass Low-Pass Velocity II Frequency Response** Bias Not OK filter RMS Peak or Peak-to-Peak 1X and 2X Vector filter 4-pole (80 db per decade, 24 db per octave). 4-pole (80 db per decade, 24 db per octave). Within ± 0.33% of full scale typical, ± 1% maximum, exclusive of filters. -3dB at 0.01 Hz -3 db at 40 Hz 10 to 5,500 Hz, -3 db. 3 to 5,500 Hz, -3 db Valid for machine speeds of 60 to 100,000 cpm. (Velocity II only) **This does not include the filtering implemented on the 3300 Velomitor and HTVS I/O modules that will be present in the case of a 3500 ENCORE Rack Upgrade. Filter Quality High-Pass Low-Pass Velomitor Sensor Alarms Alarm setpoints 2-pole (40 db per decade, 12 db per octave). 4-pole (80 db per decade, 24 db per octave). Within ± 0.33% of full scale typical, ± 1% maximum. Exclusive of filters. Full Scale 0-0.5: ±3% Typical Full Scale 0-1.0: ±2% Typical Full Scale 0-2.0: ±1% Typical The user can use software configuration to set Alert levels for each value measured by the monitor and Danger set points for any two of the values measured by the monitor. Alarms are adjustable from 0 to 100% of full-scale for each measured value. The exception is when the full-scale range exceeds the range of the transducer. In this case, the range of the transducer will limit the set points. of alarms are to within 0.13% of the desired value. Page 4 of 10

Alarm Time Delays Note: Applies to Radial Vibration, Thrust, Differential Expansion, Eccentricity, Acceleration, Velocity, Acceleration2, Velocity2 Alert Danger Static Values The user can program alarm delays using software as follows: From 1 to 60 seconds in 1 second intervals. 0.1 seconds or from 1 to 60 seconds in 0.5 second intervals. Static values are measurements used to monitor the machine. The Proximitor/Seismic Monitor returns the following static values: Radial Vibration Direct, Gap, 1X Amplitude, 1X Phase Lag, 2X Amplitude, 2X Phase Lag, Not 1X Amplitude, and Smax Amplitude. Thrust Position Differential Expansion Eccentricity Direct, Gap Direct, Gap Peak-to-peak, Gap, Direct Minimum, Direct Maximum. Shaft Absolute Radial Vibration Velocity II Barriers peak Velocity, or Band-pass peak Acceleration, or Band-pass peak Velocity. 1X Phase, 2X Phase and Bias Voltage. Direct, 1X Amplitude, & 2X Amplitude: defined as one of the following: RMS Velocity, or peak Velocity, peak-to-peak Displacement, or Band-pass peak Velocity, or Band-pass, or peak-to-peak Displacement. Additionally, 1X Phase, 2X Phase and Bias Voltage 1. The 3500/42E supports the external and internal barriers when used in a 3300 system retro fit only. Environmental Limits Operating Temperature Storage Temperature Humidity -20 C to +65 C (-4 F to +150 F) -40 C to +85 C (-40 F to +185 F). 95%, noncondensing. Shaft Absolute Velocity Acceleration II Direct, Gap, 1X Amplitude, 1X Phase. Shaft Absolute Direct, Shaft Absolute 1X Amplitude, Shaft Absolute 1X Phase, Direct, Gap, 1X Amplitude, 1X Phase. Direct, 1X Amplitude, & 2X Amplitude; defined as one of the following: RMS Acceleration, or peak Acceleration, or RMS Velocity, or 1 The I/O Module modifies the Velomitor s bias voltage. For these signals, the bias voltage is intended for trending purposes only. Page 5 of 10

Compliance and Certifications EMC European Community Directives: EMC Directive 2004/108/EC Standards: EN 61326-1:2006 Emissions and Immunity EN 61000-6-2 (2005) +C1 EN 61000-3-2 (2006) +A1, +A2 EN 61000-3-3 (2008) EN 61000-6-4 (2007) +A1 Electrical Safety Standards: EN 61010-1: 2010 European Community Directive: 2006/95/EC Low Voltage For further certification and approvals information please visit the following website: www.ge-mcs.com/bently Hazardous Area Approvals North American: Class I, Div 2. Groups A, B, C, D. T4 @ Ta = -20 C to +65 ºC. (-4 ºF to +150 ºF). Note: When installed as a retrofit monitor for a 3300 System, hazardous area approval is valid only if the existing 3300 System has the same type of approval. For further certification and approvals information please visit the following website: http://www.ge-mcs.com/en/bently-nevada.html Physical Monitor Module (Main Board) Dimensions (Height x Width x Depth) Weight 228mm (8.97 in) x 50mm (1.98 in) x 289mm (11.39 in) 1.27kg (2.8 lb) I/O Module (4 channel) Dimensions (Height x Width x Depth) Weight 208.28 mm (8.2 in) x 48.26 mm (1.9 in) x 127 mm (5 in) 0.68 kg (1.5 lb) Rack Space Requirements Monitor Module I/O Modules 1 full-height front slot. 1 full-height rear slot (for 4-channel I/O). Ordering Information General Ordering Options Proximitor Seismic Monitor 3500/42E-AXX-BXX A: I/O Module Type The 3500/42E Module requires the following (or later) firmware, and software revisions: 3500/01 Software Version 4.6 0 0 none, uses currently installed 3300 SIM or SIRM. 0 1 Proximitor/Seismic I/O module. B: Agency Approval Option 0 0 None 0 1 CSA/NRTL/C (Class 1, Div 2) Note: For installation as a retrofit monitor for a 3300 System as in a 3500 ENCORE Rack Upgrade, Agency Approval Option B01 should be ordered only if the existing 3300 System has the same type of approvals. Installation of a retrofit monitor in a system without approvals will invalidate the approvals of the monitor. Page 6 of 10

Spares 285691-01 289837-01 3500/42E Proximitor/Seismic Monitor 287546-01 287199 3500/42E Monitor Manual Jumper, 18 Pin, 2 x 9 287199 Proximitor/Seismic I/O Module 3500/42E Vibration Monitor connector shunt Page 7 of 10

Graphs and Figures A. Color LCD Display B. Buffered Transducer Outputs C. Display Control Switches D. Status LEDs Figure 1: Front view of the Proximitor*/Seismic Monitor Page 8 of 10

A. Channel A Bargraph Show Channel not in alarm B. Channel B Bargraph Shows Channel in alert C. Alert Setpoint D. Danger Setpoint E. Channel Type F. Channel Values Figure 2: LCD Display for the Proximitor/Seismic Monitor Page 9 of 10

Figure 3: Proximitor/Seismic IO Module for use in a 3500 ENCORE System * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. 2011 2013 Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-mcs.com/bently Page 10 of 10