Sequences of operations

Similar documents
20TDNH 214. Course Description:

portion of the tooth such as 3/4 Crown, 7/8Crown.

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

stone model bonding tray improve the accuracy

How to Achieve Shade Harmony With Different Restorations

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Renaissance of One-Piece Implants

One Abutment - One Time

Jacket crown. Advantage : Crown and Bridge

Class I and II Indirect Tooth-Colored Restorations

Implant Bar Overdenture Utilizing Locator Attachments

Section 16 Dental Laboratories

Restorative Guidelines

IMPRESSION TECHNIQUE AND MATERIALS

Complete Denture Processing Luther A. Ison, CDT

ADA Standards Committee on Dental Products National Standards Status of Projects. Standard # Title of Standard WG Status Activity

Abutment fracture in a bridge supported by natural teeth and implants

Composite artistry- speedy mock up

porcelain fused to metal crown

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM


Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

USAGE OF SELECTIVE LASER MELTING TECHNOLOGY CAPABILITIES IMPLEMENTATION FOR TEETH IMPLANTS METAL CONSTRUCTION IN TU-SOFIA

Single Tooth Implant Crowns

Classification of dental cements

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

IPS. Special Edition. Press-on-Metal Ceramic. Harald Gritsch Max Wörishofer Christoph Zobler

Projecting a new smile from a facial photograph:

Universal Crown and Bridge Preparation

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Milled Bar Overdentures-Protocol and Procedures

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Full Crown Module: Learner Level 3

Full Crown Module: Learner Level 1

Dentalworkers JOB DESCRIPTIONS Great Team Members make your Office function!

screw-retained single crowns using custom-cast abutments

Restoring the Endodontically Treated Tooth:Post and Core Design and Material 根 管 治 療 後 牙 齒 的 修 復 :Post and Core 的 設 計 與 材 料

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

MEDICAL TECHNOLOGY IN IMPRESSIVE 3D

Crown and Bridge Restorations. Straumann synocta Prosthetic System

Virginia Board of Dentistry

FABRICATING CUSTOM ABUTMENTS

5-Days. Masterclass. Dentistry. in Aesthetic April May. Athens, Greece. In association with

Word of Mouth. Careers in the Dental Profession. Dental Laboratory Technology. prestige. varie ty. cre ativity. flexibility. security.

Dentist: Alternative Careers. A guide for newcomers to British Columbia

Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6

State-of-the-art for your prostheses

Biodenta CAD/CAM Case Report - Urs Brodbeck, DMD, Zurich, Switzerland. Monolithic Zirconia 12unit full-arch reconstruction

Aesthetics in Removable Partial Dentures

EUROPEAN AND INTERNATIONAL STANDARDS ON MEDICAL DEVICES FOR DENTISTRY

Treatment planning for the class 0, 1A, 1B dental arches

DENTAL ADVANTAGE HELPFUL HINTS FOR THE RDA PRACTICAL EXAM

Materials. 1. a & b 2. a, b, & c 3. a, b,& d 4. all above

TABLE OF PERMITTED DUTIES (Rev. 1/1/10)

CROWN ABUTMENT TOOTH (54) (75) (73) (21) (22) (30) Shogo YAMAMOTO, Shinjuku-ku. GC Corporation, ltabashi-ku (JP) Foreign Application Priority Data

Multi-unit abutment bar overdenture

Attachments And Their Use In Removable Partial Denture Fabrication

Choosing the right type of abutment

CLINICAL SCIENCES FOR THE DENTAL ASSISTANT Course Syllabus

INSPIRED BY NATURE: CHRISTIAN FERRARI FULL FUNCTIONAL AND ESTHETIC MINIMALINVASIV RESTORATION USING IPS E.MAX CERAMICS

ADA Insurance Codes for Laboratory Procedures:

SCD Case Study. Treatment Considerations for Implant Rehabilitation

NARROW DIAMETER implant

Implant Parts. A Radford Heath Guide 1

Prosthodontist s Perspective

ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH

Nobel Clinician - Quick Guide

DISTRICT OF COLUMBIA MUNICIPAL REGULATIONS FOR DENTAL ASSISTANTS

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

Encode Restorative System Procedure & Laboratory Manual

Ohio State Dental Board Permissible Duties of Dental Hygienists and Dental Assistants

OHIO ADMINISTRATIVE CODE CHAPTER 4715

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

prosthetic technique manual

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

CDT 2015 Code Change Summary New codes effective 1/1/2015

HEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014

The Attractive Glass Abutment System (ZX-27) HANDOUT

Restorative Manual Impression Transfer System

THE VOICE OF TECHNO-CLINICAL DENTISTRY

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

Removable Partial Dentures 101 Back to the Basics. Luther A. Ison, CDT University of Minnesota School of Dentistry

Full Mouth Rehabilitation of a Patient with Bilateral Asymmetric Posterior Open Bite: A Case Report

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

Rapid prototyping. CAD / lecture. October 5, TO&I Vermelding onderdeel organisatie

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Department of Veterans Affairs VA HANDBOOK 5005/46 STAFFING

Transcription:

Sequences of operations Fixed dentures: Full crown Made of metal alloy (gold or chromcobalt) Preparation Reduction 0,5 mm around, occlusaly 1 mm Preparation border shoulderless or very slight round shoulder, located subgingivally 0,5 mm. Before the impression the retraction cord is applied around the tooth subgingivally in order to open gingival sulcus and take an exact impression of this area. Dual viscosity technique. a) Dual viscosity technique double impression or b) Simultaneous dual viscosity technique. Antagonal impression of alginate Occlusal registration (wax) Making the cast (model) of gypsum (pouring the impression). rock: Plasters----- model plaster, lab plaster Densite ------high strength dental stone High strength dental stone is used for fixed dentures. Wax pattern Lost wax method. investment and casting, finishing. 1

2. Phase in dental office Tryin of the crown and its cementation. Metal ceramic crown Made of metal alloy ( usu chromcobalt) and ceramics which covers the metal framework These crowns are fully covered with ceramic material. Preparation Reduction 1 mm around, occlusaly 1, 5 mm. Preparation border - rounded shoulder located subgingivally 0,5 mm. Before the impression the retraction cord is applied around the tooth subgingivally in order to open gingival sulcus and take an exact impression of this area. Dual viscosity technique. a) Dual viscosity technique double impression or b) Simultaneous dual viscosity technique. Antagonal impression of alginate Occlusal registration (wax) Making the cast (model) of gypsum (pouring the impression). rock: Wax pattern of the metal Framework of the metalceramic crown. 2

The wax is changed with the metal alloy used the lost wax method. investment and casting, After casting follows finishing of the framework 2. Phase in dental office Trying of the metal Framework and choice of colour 2. Phase in dental lab Making of ceramic facette coat (fully covered crown) special procedure firing in a special oven in several phases. 3. Phase in dental office Trying of the crown and cementation Facette crown This crown is made of the metal alloy (golden or chromcobalt), partially covered with composite or methylmethacrylic resin Preparation Reduction 1 mm vestibulary, orally 0,5 mm, occlusaly 1 mm Preparation border: rounded shoulder located 0,5 subgingivally Retraction cord around the tooth Dual viscosity technique or single viscosity technique. Dual viscosity technique double impression Simultaneous dual viscosity technique Antagonal impression Alginate Occlusal registration (wax, elastomeric materials) 2. Phase in dental lab. Making the cast (model) of gypsum. rock depending on on the nature: 3

Wax pattern Lost wax method. investment and casting, finishing of the framework 3. Phase in dental office Trying of the metalframework and colour choice 3. Phase in dental labe Making of veneer (partially covered crown) There are two possibilities: If the facette is made of the composite material the material is applied directly on the metal framework and cured. If the facette is made od methylmetacrylic resin te facette is modelled of wax, put into the flask (two parts) with plaster, after the plaster has been set, the wax is removed with hot water and replaced with resin dought, closed again and the resin is polymerized in hot water. The procedur eis principally the same as with jackette crown made of methylmetacrylic resin. Jackette crown Preparation Reduction 1 mm around, incoisally 1, 5 mm Preparation border rectangle shoulder Located subgingivally 0,5 mm. Retraction cord around the tooth 4

Dual viscosity technique or single viscosity technique. Dual viscosity technique double impression Simultaneous dual viscosity technique Antagonal impression Alginate Occlusal registration (wax, elastomeric materials) Making the cast (model) of gypsum. rock depending on on the nature: Wax pattern not of the casting wax, but of modelling wax (pink colour) The model must be isolated. The wax model of the crown is put into a flask (two parts), after the plaster has been set, the wax is removed with hot water and replaced with resin dought, the flask is closed and the resin is polymerized in hot water. 2. Phase in dental office Try and cementation. 5