DSA-LX Digital Signal Analyzer

Similar documents
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Description: Multiparameter System (4 or 8 channels)

Impedance 50 (75 connectors via adapters)

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

IDM-200 -V. Interchangeable HPGe Detector Module (IDM) for Systems Integrators

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

R&S ZNBT8 Vector Network Analyzer Specifications

Multi-Range Programmable DC Power Supplies 9115 Series

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

DC Electronic Loads 8500 series

Op Amp Circuit Collection

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Transmitter Interface Program

Multi-Range Programmable DC Power Supplies 9115 Series

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

An Innovative, portable MCA based on Digital Signal Processing. R.D. Bingham, R.M. Keyser, T.R. Twomey

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

R&S ZNC Vector Network Analyzer Specifications

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

NI USB-5681 RF Power Meter Specifications

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Physical Specifications (Custom design available.)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

DCS Series 1 kw, 1.2 kw, & 3 kw

Pixie Viewer Online Help

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

R&S ZVA Vector Network Analyzer Specifications

Lab 1: The Digital Oscilloscope

NIM High Voltage Power Supplies

MODEL 1211 CURRENT PREAMPLEFIER

MAESTRO 7. Multichannel Analyzer (MCA) Application Software

Agilent 8904A Multifunction Synthesizer dc to 600 khz

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

User Manual. EtherUSB

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

I STAR COMPUTER CO., LTD

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

How To Use A High Definition Oscilloscope

MANUAL FOR RX700 LR and NR

FREQUENCY RESPONSE ANALYZERS

Low and High Voltage Power Supplies

Power Amplifier Gain Compression Measurements

1.44 kw Programmable DC Power Supplies XLN Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Quick Connect. quick - simple - efficient.

Preset Counter signo 721

BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

LT-82 Stationary IR Transmitter

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

ECONseries Low Cost USB DAQ

Agilent E5100A Network Analyzer

T0118 T2118 T3118. Instruction Manual

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

How To Use An Hm804X Series Of Power Supplies

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

U1602A Handheld Oscilloscopes, 20 MHz

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

khz to 2.7 GHz Spectrum Analyzer

T Substation Maintenance and Commissioning Test Equipment

Electronics GRETINA Project

High Voltage Power Supplies

SMS GSM Alarm Messenger

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

3500/22M Transient Data Interface

High Power Programmable DC Power Supplies PVS Series

Temperature & Humidity SMS Alert Controller

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

RF Measurements Using a Modular Digitizer

Analog Servo Drive 25A8

HP 70950B OPTICAL SPECTRUM ANALYZER

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Product Information Sheet UH28CS-12kV Hi Pot Tester

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

DPI 260 SERIES: Digital Pressure Indicators

Wahl C50 Calibrator FEATURES

DVT913 TV CHANNEL CONVERTER

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Indoor / Outdoor Antenna

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Arbitrary/Function Generators AFG3000C Series Datasheet

Product Information Sheet UH36 Hi Pot Tester

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

ugrid Testbed. Rein in microgrid complexity. With ease.

Transcription:

Features Integrated desktop MCA based on Digital Signal Processing (DSP) Excellent count rate and temperature stability Wide range of processing time parameters to allow precise match to detector characteristics and application requirements 16K Channel conversion gain /spectrum memory USB 2.0 interface allows simple connection to computer Convenient small form-factor desktop package Full set of front panel indicators Performs pulse height analysis (PHA) or multichannel scaling (MCS) Advanced patented* auto pole /zero, base line restoration and digital stabilization capability Web-based digital oscilloscope spectrum viewer and maintenance utility Built-in power up diagnostics Supported by Genie 2000 DSA-LX Digital Signal Analyzer Description The DSA-LX is a full featured 16K channel integrated Multichannel Analyzer based on advanced digital signal processing techniques (DSP). When paired with a computer running Genie 2000 software the DSA-LX becomes a complete spectroscopy workstation, capable of the highest quality acquisition and analysis. The instrument interfaces to existing detector technologies such as HPGe, NaI, Si(Li), CdTe or Cd(Zn)Te. The DSA-LX offers cost effective, no-compromise DSP-quality spectroscopy in a very compact package. It is operated through CANBERRA s Genie 2000 spectroscopy software which provides the user with ultimate flexibility. A wide range of application specific software options are available under the Genie 2000 family. This highly integrated instrument incorporates front end signal conditioning, a fast digitizing analog-to-digital converter (ADC), programmable digital filters, digital oscilloscope, automatic pole /zero* and base line restorer, digital fast discriminator, two groups of 16K channel spectral memory, digital stabilizer and a dual-range HVPS all in a small, compact package. Lighted indicators are included on the front and rear panels to alert the user to power, acquisition, communication, high voltage and count rate status at a glance. * US Patent 7725281: automatic pole /zero Nuclear Measurement Solutions for Safety, Security and the Environment www.canberra.com C40325 04/14

The use of DSP technology improves the overall signal acquisition performance. Signal filtering functions previously implemented in traditional analog electronics are limited. DSP allows filtering functions and pulse shapes that are not realizable using conventional analog processing techniques. The result is a more efficient trapezoidal filter function, which exhibits less processing time, less sensitivity to ballistic deficit, and superior resolution. With trapezoidal filtering, the pulses can be processed more rapidly and accurately, so the spectrum resolution is enhanced while throughput is increased. The DSA-LX offers peak gain stability at up to a factor of two to three times better than past generation analog products while Zero drift is barely measurable over the full operating temperature range of the instrument. The DSA-LX supports both the traditional Pulse Height Analysis (PHA) mode as well as a MultiChannel scaling (MCS) mode for time varying applications. The MCS mode can display data from an external TTL input, a full spectrum integral or a Region of Interest (ROI). The DSA-LX provides host communications via Universal Serial Bus (USB) 2.0 interface which provides full speed communications at 12 Mbit /s. USB provides the additional capability of having multiple units attached to a single host /port via a USB hub. The DSA-LX contains includes an interface which allows the user to monitor the system status, view the spectrum, maintain and update system settings and access the built in digital oscilloscope. With the built in digital oscilloscope, the user views a graphical reconstruction of the digitized, filtered signal. Scaling and trigger functions are similar to those of an actual oscilloscope. DSA-LX rear panel DSA-LX built in web interface (Spectrum Viewer) DSA-LX vertically mounted (stand included) DSA-LX Digital Oscilloscope

Specifications INPUTS/OUTPUTS ENERGY Accepts positive or negative detector preamplifier signals with rise times less than the selected Rise Time + Flat Top settings and decay times of 45 µs and upwards. The input amplitude for full scale is ± 2V divided by selected Gain and Attenuation settings. The input is dc coupled and the maximum input (signal +dc) for linear operation is dependent on the input Attenuator setting; Attenuator OFF (x1): ±4 V, Attenuator ON (x 0.25): ±12 V and is protected to ± 24 V maximum; With the Attenuator OFF (x1) the input impedance is 575 Ω for a Coarse gain of 2 and 907 Ω for Coarse Gains greater than 2. With the Attenuator ON (x 0.25) the input impedance is 1575 Ω for a Coarse Gain of 2 and 1907 Ω for Coarse gain greater than 2; rear panel BNC connector. TRP INH Accepts a standard TTL Logic signal; functionality is dependent on the Reset Preamp Inhibit mode selected; disables pulse processing, extends the system dead time, resets the pileup rejector and gates off the baseline restorer; rear panel BNC connector. Auto: System is gated off for the greater of the external RESET signal OR the Internal Inhibit time. Manual: Functionality same as Auto mode except the signal processor is inhibited for the greater of the user selected. Inhibit Setting OR the Internal Inhibit Time OR the external RESET signal. Positive true or negative true signal polarities, user selectable; minimum pulse width is 100 ns; logic high +2 V, logic low +0.8 V; maximum input voltage +5.5 V. HV INH Accepts input from the detector preamplifier to shut down the HVPS in the event of a detector warm-up; polarity is user selectable to match the preamplifier; rear panel BNC connector. Positive polarity: for all CANBERRA preamplifiers; Enable condition (cold detector) is an open circuit or active high +1.2 V to +24 V; Inhibit condition (warm detector) is 24 V to <+1.2 V or ground. Negative polarity: for all preamplifiers and LN monitors where enable condition (cold detector) is 24 V to <+1.2 V; Inhibit condition (warm detector) is open circuit or active high +1.2 V to +24 V. With Negative selected an open input will disable the high voltage. MCS MCS counts input; TTL compatible; maximum rate 1 MHz; minimum pulse width 50 ns; logic low +0.8 V, logic high +2 V; rear panel MCX connector. POWER DC power input from supplied ac adapter; 2.5/5.5 mm locking rear panel connector; Nominal 12 V dc at 1.0 amps. HV Dual range and polarity high voltage power supply; voltage range and polarity selected by software: ± 200 to ±1500 V dc or ±1500 to ±5000 V dc; separate rear panel SHV connectors for positive and negative. MON OUT A real-time image of the internally-shaped energy signal for use with an external oscilloscope. Can be used in diagnostic mode to review the energy signal quality. Sample Changer RDY Accepts Sample Changer Ready signals; signal is TTLcompatible; polarity is software selectable. Sample Changer ADV Sample Changer Advance output provides a 150 ms TTLcompatible pulse for each sample advance command. USB Full Speed USB interface for host communication; rear panel USB Series B connector. The maximum cable length supported by USB is 5 m. PREAMP Provides ± 24 V (± 5%), ±12 V (± 5%) and ground for standard preamplifiers; overload protected. +24 V at 50 ma max 24 V at 50 ma max +12 V at 100 ma max 12 V at 100 ma max Rear panel 9-pin female D connector. FRONT/REAR PANEL INDICATORS POWER Green LED showing presence of system power. ACQUIRE /BSY Multicolor LED showing acquisition and instrument status. COMM Green LED showing communications status. Illuminates each time the instrument is sending or receiving data over the USB communication interface. HV Multicolor LED indicating the state of the selected high voltage power supply output. ICR Multicolor LED showing Incoming Count Rate. Illuminates each time the instrument processes an incoming pulse. The intensity of the LED is proportional to the incoming count rate. Also indicates if incoming rate is within APZ range.

REAR PANEL CONTROL Power Power to the DSA-LX is enabled when the switch is set ON; rocker switch located on rear panel. PROGRAMMABLE CONTROLS Gain The combination of Coarse Gain and Fine Gain sets the overall system gain to match the requirements of the detector and energy application; overall gain is continuously adjustable from x1.6 to x516.6. COARSE GAIN x2.0 x430.5 in 19% increments. FINE GAIN Range is x0.8 to x1.2 in ~0.004% increments. GAIN ATTENUATOR ON/OFF; When ON is selected it enables a divide by four input attenuator to minimize overload due to preamp signals with large pulse amplitudes or dc offsets and Reset Preamps with large output ramp dynamic range; When OFF is selected the signal attenuation is removed. MCA/Input Size PHA MODE Selections of 256, 512, 1024, 2048, 4096, 8192 or 16 384 channels. Support for two memory groups of equal size. MCS MODE Selections of 256, 512, 1024, 2048, 4096 8192 or 16 384 channels. Support for two memory groups of equal size. LLD MODE Selects Automatic or Manual LLD mode; AUTOMATIC: the LLD cutoff is automatically set just above the spectral noise threshold; MANUAL: allows the LLD cutoff to be set manually as a percentage of the full scale spectral size or range. LLD SETTING Active when the Manual LLD mode is selected, sets the minimum input acceptance level, range is 0 to 100%. INP POLARITY Selects either POSITIVE or NEGATIVE input polarity. INH POLARITY Selects either Active High or Active Low Reset Preamp Inhibit polarity. PUR GUARD Selects Guard Time (GT) multiplier in increments of 1.1 to 2.5 in 0.1 increments to reject trailing edge pile-up in the event of detector/preamp anomalies. FDISC SHAPING Selects NORMAL or LOW ENERGY to optimize the fast discriminator shaping for the selected detector type; NORMAL: The Fast Discriminator shaping is optimized for Ge detectors and general gamma spectroscopy, the fast discriminator filter rise time is set to 100 ns; LOW ENERGY: the Fast Discriminator filter rise time is set proportional to the slow shaping rise time selection. FDISC MODE Sets the Fast Discriminator Threshold mode. AUTO: the threshold is optimized automatically above the system noise level; MANUAL: allows threshold to be adjusted manually. FDISC SETTING Active when manual FDISC mode is selected; sets the Fast Discriminator threshold level, range is 0 to 100%; the front panel ICR LED serves as a user aid when manually setting the Fast Discriminator threshold. INHIBIT MODE Selects AUTO or MANUAL Reset Preamp Inhibit Modes; the Inhibit signal disables pulse processing, extends the system dead time, reinitializes the pileup rejector and gates off the baseline restorer. AUTO System is gated off for the greater of the external RESET signal OR the Internal Inhibit Time. MANUAL Functionality same as Auto mode except the signal processor is inhibited for the greater of the user selected Inhibit Setting OR the external RESET signal OR the Internal Inhibit Time. INHIBIT SETTING Active when the MANUAL Reset Preamp Inhibit Mode is selected, sets the Inhibit Time, range 0 to 160 µs in increments of 1 µs. LTC MODE ON/OFF; ON: Enables pileup rejector and live time corrector (LTC). LTC generates dead time to extend the acquisition time to compensate for events that are piled up and rejected; OFF: pileup rejector and LTC disabled. LT TRIM Allows adjustment of the trapezoidal pulse evolution time or dead time to optimize Live Time Correction (LTC) performance. The adjustment range is 0 to 1000; the default value of 500 provides good LTC performance for a wide range of applications. Filter Note: Filter output (Trapezoid Signal) may be displayed on the Host computer using the digital oscilloscope feature. RISE TIME Rise and fall times ranging from 0.2 to 38 µs. FLAT TOP Flat top time selections ranging from 0 to 3 µs. BLR MODE AUTO, HARD, MEDIUM, SOFT; AUTO: The baseline restorer is automatically optimized as a function of trapezoid shaping time and count rate; HARD, MEDIUM, or SOFT: Sets the baseline restorer to fixed rates as selected. POLE/ZERO The patented Automatic Pole/Zero function is implemented by using successive approximation technique which reduces the automatic adjustment time to 10-15 seconds (typically). The adjustment is accurate and independent of base-line offset and immune to risetime variations. Therefore no inspection of the base line is needed. Thus, the pole-zero can be adjusted precisely even at relatively high counting rates.

PREAMP TYPE RC, RESET; selects the pole/zero mode; RC: pole/zero can be adjusted manually by computer command; range: 45 µs to infinity; RESET: Sets pole/zero at infinity for use with pulsed charged restoration (RESET) preamplifiers. MIXED SIGNAL OSCILLOSCOPE Allows examination of the digital trapezoid signal reconstructed in time to assist and verify instrument setup, pole/zero optimization and manual Reset Preamp INHIBIT adjustments. Stabilizer GAIN MODE ON, OFF, HOLD; ON/OFF: enables or disables the Gain Mode; HOLD: disables the stabilizer Gain Mode, but maintains the current Gain correction factor; Centroid (2 to 16 376 channels), Window (1 to 128 channels), Spacing (2 to 512 channels), Ratio (0.01 to 100), Rate Div (1 to 128); Correction Range of 1% for Ge and 10% for NaI detectors. SAMPLE CHANGER CONTROL Sample changer advance and ready signal polarities may be set separately for positive and negative. The changer may be manually advanced via an ADVANCE CHANGER button in the software. Multichannel Scaling MODES TTL, FDisc, ROI. Events are counted for the duration of a programmed number of sweeps. Each SWEEP incorporates a programmed number of channels. Each channel represents a DWELL duration. TTL TTL-compatible pulses counted from MCS IN connector. FDisc Gamma events counted from the fast discriminator. ROI DSP gamma events counted if they occur within the programmed ROI window. PROGRAMMABLE SETTINGS DWELL TIME SETTINGS From 1 µs to 999 s selectable through three ranges: 1 µs to 999 µs, 1 ms to 999 ms, 1 s to 999 s. DWELL TIME RESOLUTION 1 µs for 1-999 µs range, 1 ms for 1-999 ms range and 1 s for 1-999 s range. SWEEP COUNTER 1 to 4294967295 or infinite sweeps. ROI DISC WINDOW 1 to 16 384 channels. SWEEP MODE Sweep Counter or Sweep Forever. MCS CHANNEL RANGE 256 to 16 384. START/STOP CONTROL through software. PERFORMANCE Signal Processing SPECTRUM BROADENING The FWHM of 60 Co 1.33 MeV gamma peak for an incoming count rate of 2 kcps to 100 kcps will typically change less than 6% for 2.8 µs rise/fall time, 0.8 µs flat top and proper P/Z matching. These results may not be reproducible if the associated detector exhibits an inordinate amount of long rise time signals. INTEGRAL NON-LINEARITY ±0.025% of full scale over the top 99% of selected range. DIFFERENTIAL NON-LINEARITY ±1% over the top 99% of the range including the effects from integral non-linearity. GAIN DRIFT 35 ppm/ C after 15 minutes of operation. ZERO DRIFT 3 ppm/ C after 15 minutes of operation. Typically, less than 1 channel over full temperature range (8K Spectrum). OVERLOAD RECOVERY Recovers to within 1% of full scale output from x1000 overload in 2.5 non overlapped pulse widths at full gain, at any shaping (processing time), and with pole/zero properly set. Pileup Rejection/Live Time Correction PULSE PAIR RESOLUTION Better than 500 ns with NORMAL Fast Discriminator mode selected. DEAD TIME CORRECTION Extended live time correction, accuracy of reference peak area changes 5% (3% typical) at up to 50% system dead time with a setting of 5.6 µs rise time and 0.8 µs flat top. Acquisition DATA MEMORY GROUPS 1 16K (PHA) Channels or 2 16K (PHA) channels; 32 bits per channel. STORAGE MODE PHA or MCS. Simultaneous operation of PHA / MCS is supported. PRESET MODES PHA Mode Live or True Time, Counts in single channel, Counts in ROI, Counts in multiple ROIs. MCS Mode Sweeps, Count greater or equal to preset Counts, Count greater or equal to preset ROI Counts. TIME RESOLUTION 0.01 s live and real time. PRESET TIME 0.01 s through 42 949 000.00 s. PRESET SWEEPS 1 to 4 294 967 295 or infinite sweeps.

High Voltage Power Supply All outputs are current limited and short circuit protected. HV Inhibit input, two modes: Positive polarity: (for CANBERRA preamplifiers); Enable condition (cold detector) is an open circuit or active high = +1.2 V to +24 V; Inhibit condition (warm detector) is 24 V to <+1.2 V or ground. Negative polarity: for preamplifiers and LN monitors where enable condition (cold detector) is 24 V to <+1.2 V; Inhibit condition (warm detector) is open circuit or active high = +1.2 V to +24 V. With Negative polarity selected an open input will disable the high voltage. NOTE: After Inhibit is removed the high voltage remains inhibited until the user acknowledges the fault condition via a reset of the high voltage supply. Separate SHV connectors for positive and negative high range outputs. HVPS RANGE 1: ± 200 ±1500 V at 1 ma max. RIPPLE 5 mv P-P. TEMPERATURE COEFFICIENT ±50 ppm/ C. STABILITY 0.01%/h, 0.02%/8 h. ACCURACY ±5%. ± 2.5% typical. LOAD REGULATION 1%. SETTING RESOLUTION 12-bit (1/4096). CABLES USB (provided) Used to connect the host industry standard computer USB port to the DSA-LX rear panel USB port; 3 m (10 ft); shielded cable. MCX to BNC, 4 pcs. PHYSICAL All metal enclosure. SIZE 5.58 x 16.51 x 20.95 cm (2.2 x 6.5 x 8.25 in.). WEIGHT 1451 g (3.2 lb). ENVIRONMENTAL OPERATING TEMPERATURE -20 to 50 C (-4 to 122 F). OPERATING HUMIDITY 85% non-condensing. Meets the environmental conditions specified by EN 61010, Installation Category I, Pollution Degree 2. ORDERING INFORMATION DSA-LX Digital Signal Analyzer. Requires Genie 2000 V3.3 with DSA-LX Support software, or later. DSA-LX-MOUNTKIT DSA-LX19 RACK MOUNT KIT Allows mounting of one or two DSA-LX MCAs in a cabinet. HVPS RANGE 2: ±1500 5000 V at 1 µa max. RIPPLE 10 mv P-P. TEMPERATURE COEFFICIENT ±50 ppm/ C. STABILITY 0.01%/h, 0.02%/8 h. ACCURACY ±5%. ± 2.5% typical. LOAD REGULATION 1%. SETTING RESOLUTION 12-bit (1/4096). DSA-LX and Genie are trademarks of Canberra Industries, Inc. 2014 Canberra Industries, Inc. All rights reserved.