Air data test indicator Model CPA2501

Similar documents
Precision Pressure Indicator Model CPG2500

Hand-held thermometer Model CTH7000

Precision digital pressure gauge Model CPG1500

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

PACE Modular Pressure Controller

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

The PACE5000 Modular Pressure Controller/Indicator

1.44 kw Programmable DC Power Supplies XLN Series

High-End Pressure Controller Model CPC8000

Compact pressure switch Flameproof enclosure Ex d Model PCA

Multi-Range Programmable DC Power Supplies 9115 Series

PACE1001 Barometer Precision Barometric Indicator and Recorder

Vacuum drying oven for non-flammable solvents

PACE1000 Precision Pressure Indicator

Multi-Range Programmable DC Power Supplies 9115 Series

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Incubator with mechanical convection

DC Electronic Loads 8500 series

High Power Programmable DC Power Supplies PVS Series

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

R&S SMZ Frequency Multiplier Specifications

OZW30. Central Unit SYNERGYR

3500/93 System Display

Bimetal thermometer Model 52, industrial series

Indoor / Outdoor Antenna

Rackmount Intelligent Pressure Scanners

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

NI USB-5681 RF Power Meter Specifications

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Repeaters and Mimics Data Sheet

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Material test chamber with mechanical convection

T0118 T2118 T3118. Instruction Manual

RUSKA PRODUCTS - PRICE LIST

Battery Powered Digital Mass Flow Meters for Gases

MCR1900 Media Converter 19-Slot Chassis

Product Information Sheet UH36 Hi Pot Tester

USER GUIDE. For more information visit

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

QuickSpecs. Models HP Server Console Switches

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

R&S ZNC Vector Network Analyzer Specifications

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

CompactLogix Power Supplies Specifications

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Heating oven with mechanical control

Druck DPI 142/150. GE Infrastructure Sensing. Pressure Indicator Calibration manual - K382

Duct Humidity Transmitter

J TB/TW Temperature limiter, temperature monitor

Assisted lift operated 2/2-way solenoid valves Type EV250B

INSTALLING A/C ADAPTER

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

SPID Azimuth Antenna rotator Type: BIG-RAK/HR

Senses SV series industrial monitor user manual

EasyTrack 2 Accessories List

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Battery Powered Thermal Mass Flow Meters for Gases

How To Use A Ds340 (Dsp)

R&S ZNBT8 Vector Network Analyzer Specifications

TORKEL 820 Battery Load Unit

TrueAlarm Fire Alarm Systems

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PXI Express Chassis with Integrated MXI-Express Remote Controller

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

4-Channel Thermometer / Datalogger

Temperature & Humidity SMS Alert Controller

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

3500/62 Process Variable Monitor

Power Meter Series 700

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Quick Connect. quick - simple - efficient.

Physical Specifications (Custom design available.)

Test equipment for temperature and its reduction

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ADU 5. Automatic Distillation Unit

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

VDL 53 - Vacuum drying oven for flammable solvents

HP Server Console Switch with Virtual Media Overview

3500/22M Transient Data Interface

Proportional pressure regulators VPPE

Differential Pressure Transmitter Model DPT-10

3DLevelScanner II TECHNICAL DATA SHEET

Scout 1U Rackmount Computer

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Product Information Sheet UH28CS-12kV Hi Pot Tester

Electronic Pressure Switch EDS 300

WEATHER STATION FOR SOLAR FARM MONITORING

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Transcription:

Calibration technology Air data test indicator Model CPA2501 WIKA data sheet CT 29.02 Applications Aviation calibration laboratories Aviation repair stations Manufacturers of avionics equipment Manufacturers of aerospace equipment Wind tunnels Special features Accuracy up to 0.01 % FS RVSM compliant Ps, Qc, Ps/Pt or Ps/Qc configuration with virtual channels Altitude and airspeed rate indication Altitude ranges to 100,000 ft. and airspeed ranges to 1,150 knots Air data test indicator, model CPA2501 Description Application The model CPA2501 air data test indicator is used in aviation and aerospace applications for calibration of altimeters and airspeed indicators, displaying altitude, airspeed, altitude rate (vertical airspeed) and airspeed rate (acceleration). Applied wherever there is a need for a high level of accuracy in an avionics indicator or calibration instrument. Functionality The CPA2501 can be configured with an altitude channel and an airspeed channel consisting of Ps/Pt or Ps/Qc. It can be configured as a single-channel altitude/altitude rate indicator, (Ps only) a single-channel airspeed/airspeed rate indicator (Qc only) or it can be a dual-channel unit configured as Ps/Pt or Ps/Qc. In the Ps/Pt version the airspeed/airspeed rate channel is a calculated channel. An optional barometer can be installed for display in the front panel or as a separate channel. Pressure ranges for each channel can be specified by the customer. Versions The CPA2501 versions are as follows: Ps (altitude version) Qc (airspeed version) Ps/Qc with a virtual Pt channel Ps/Pt with a virtual Qc channel An optional barometric sensor can be added to any version. Communication The manual user interface is through a widescreen display with touchscreen. Navigation within the intuitive menu structure is easily learned. Recognisable touchscreen icons open screens for configuration and calibration. Communicating to a remote computer is achieved through RS-232, IEEE-488, USB or Ethernet. Communication commands are the same as the previous version of Mensor avionics gauge models 2108 and 2109 or the WIKA command set SCPI. WIKA data sheet CT 29.02 04/2016 Page 1 of 8 Data sheets showing similar products: Precision pressure sensor, models CPT6100, CPT6180, see data sheet CT 25.10

Specifications Model CPA2501 Reference pressure sensor - model CPR8001 P s sensor Measuring range 0... 950 mbar abs. up to 0... 1,253 mbar abs. 0... 29.5 inhg at 0 C up to 0... 37 inhg at 0 C Accuracy 1) 0.009 % IS-50 2) P t sensor Measuring range Accuracy 1) Q c sensor Measuring range Accuracy 1) Barometric reference Function Measuring range Accuracy 1) Pressure units Aviation units Calibration interval 0... 1,355 mbar abs. up to 0... 3,725 mbar abs. 0... 40 inhg at 0 C up to 0... 110 inhg at 0 C Standard: 0.01 % FS Optional: 0.01 % IS-50 2) -34... +100 mbar up to -34... +3,386 mbar -1... +3 inhg at 0 C up to -1... +100 inhg at 0 C 0.01 % FS The barometric reference can be used to switch pressure types (absolute <=> gauge). With gauge pressure sensors, the measuring range of the sensors must begin with -1 bar in order to carry out an absolute pressure emulation. 575... 1,151 mbar abs. 17... 34 inhg abs. at 0 C 0.01 % of reading 38 and 2 user-defined units Altitude: feet, miles, meter, kilometer Airspeed: knots, mph, km/h, meter/s, TAS (True Air Speed), IAS (Indicated Air Speed) 365 days 1) It is defined by the total measurement uncertainty, which is expressed with the coverage factor (k = 2) and includes the following factors: the intrinsic performance of the instrument, the measurement uncertainty of the reference instrument, long-term stability, influence of ambient conditions, drift and temperature effects over the compensated range during a periodic zero point adjustment. 2) 0.009 % IS-50 accuracy: Between 0... 50 % of the scale range, the accuracy is 0.009 % of the half scale range and between 50... 100 % of the scale range, the accuracy is 0.009 % of reading. Accuracy P s pressure range 0.009 % IS-50 2) 0 32 inhg abs. Altitude Q c pressure range Airspeed Sea level ±3 ft 10,000 ft ±4 ft 25,000 ft ±7 ft 40,000 ft ±12 ft 60,000 ft ±31 ft 0.01 % FS -1 +36 inhg 50 kn ±1.0 kn 100 kn ±0.4 kn 200 kn ±0.2 kn 500 kn ±0.06 kn 0.009 % IS-50 2) 0 35 inhg abs. Sea level ±3 ft 10,000 ft ±4 ft 25,000 ft ±7 ft 40,000 ft ±13 ft 60,000 ft ±34 ft 0.01 % FS -1 +103 inhg 100 kn ±1.0 kn 200 kn ±0.5 kn 500 kn ±0.2 kn 1,000 kn ±0.04 kn Base instrument Instrument Instrument version Warm-up time Dimensions Weight Standard: Desktop case Option: - 19" rack mounting with side panels incl. rack-mounting kit for single instrument mount - 19" rack mounting with side panels incl. rack-mounting kit for dual instrument mount Approx. 15 min See technical drawings < 2.3 kg (< 5 lbs) with all internal options Page 2 of 8 WIKA data sheet CT 29.02 04/2016

Base instrument Display Screen Resolution Input methods Languages Connections Number of integrateable sensors (selectable) Pressure connections Permissible pressure media Overpressure limits Metals in contact with media Voltage supply Power supply unit Power consumption Power supply Permissible ambient conditions Operating temperature Storage temperature Relative humidity Compensated temperature range Orientation Operating altitude Communication Interface Command sets Response time 7" colour LC display Selectable from 4... 6 digits, depending on range and units Resistive touchscreen English, German, Spanish, French, Italian, Portuguese, Polish, Russian, Chinese, Japanese, Korean Standard: 1 reference pressure sensor Option: 2nd reference pressure sensor, external pressure sensor and barometric reference 7/16"- 20 F SAE (adapters provided) Dry, clean air or nitrogen (ISO 8573-1:2010 Class 5.5.4 or better) 110 % FS typical, optional external relief valves are available 6000/7000 series aluminium, stainless steel 316, brass AC 100... 120 V or AC 200... 240 V, 50... 60 Hz, max. 24 A max. 90 VA DC 12 V / 1.67 A (includes 4 region-specific plugs adapters) 15... 45 C (59... 113 F) -20... +70 C (-4... +158 F) 35... 85 % r. h. (non-condensing) 15... 45 C (59... 113 F) Negligible, can be removed with re-zeroing < 3,048 m (10,000 ft) RS-232, Ethernet, IEEE-488 and USB Mensor, WIKA SCPI 80 ms Approvals Logo Description Country EC declaration of conformity EMC directive EN 61326-1 emission (group 1, class A) and interference immunity (industrial application) Low voltage directive EN 61010-1 European Community Certificates Certificate Calibration 3) Recommended recalibration interval Standard: A2LA calibration certificate Option: DKD/DAkkS calibration certificate 1 year (dependent on conditions of use) 3) Calibration in a horizontal position. Approvals and certificates, see website WIKA data sheet CT 29.02 04/2016 Page 3 of 8

Electrical and pressure connections - rear view 1 11 10 9 8 7 6 5 4 3 2 1 Connection for optional barometric reference 2 Port P s 3 Port Q c 4 Port P t / Q c 5 Power supply 6 USB interface (host) 7 Ethernet port 8 USB interface (instrument) 9 RS-232 interface 10 IEEE interface 11 External sensor connection Page 4 of 8 WIKA data sheet CT 29.02 04/2016

Dimensions in mm (in) Desktop case Front view Side view (left) 133.4 (5.25) 218.4 (8.60) 11.4 (0.45) 322.6 (12.7) 19" rack mounting, front view Single instrument 101.6 177 (4.00) (6.97) 465.1 (18.31) 481.8 (18.97) Dual instrument 101.6 177 (4.00) (6.97) 465.1 (18.31) 481.8 (18.97) WIKA data sheet CT 29.02 04/2016 Page 5 of 8

Operator interface Dual-frame channel P S and Q C without auxiliary display Reading for optional barometer Dual-frame channel P S and Q C with auxiliary display Frame configuration Local operation The intuitive operator interface of the CPA2501 provides visibility of one, two or three channels, each with or without the auxiliary display. Readings from the optional barometer can also be displayed in the lower right-hand corner. Pressure units for each channel and the barometer can be selected from a list of 38 metric and imperial units. The setup apps are continuously visible for fast configuration of various applications. Remote operation Remote control of the CPA2501 is achieved through the use of the IEEE-488, RS-232, Ethernet or USB interface. Page 6 of 8 WIKA data sheet CT 29.02 04/2016

Reference pressure sensors Interchangeable sensor CPR8001 One or two pressure sensors can be chosen (see specifications). The interchangeable sensor CPR8001 are a special feature of the air data test indicator. Interchangeable sensors guarantee long-term operation with practically no downtime. The sensor can be removed for calibration can replaced by a freshly calibrated sensor. The ability to remove a sensor for calibration and replace it with a freshly calibrated sensor while the instruments remains in service saves time and money. Reference pressure sensor model CPR8001 Simply remove the four slotted screws on the rear panel, slide the reference pressure sensor out and remove the interface cable. An optional removable internal barometric reference can also be ordered. The instrument can be adapted to different calibration and measurement tasks due to the easily exchangeable sensor technology. All relevant sensor calibration and characterisation data is stored on the sensor electronics which is individually generated for each sensor. All CPR8001 reference pressure sensors can be calibrated while in the instrument using the instrument firmware. They can also be calibrated externally with an optional interface cable/power cord, calibration sled (barometer only) and remote calibration software. Removable or replaceable barometric reference 1 2 1 Slotted screws (typical) 2 Removable reference pressure sensors model CPR8001 WIKA data sheet CT 29.02 04/2016 Page 7 of 8

Scope of delivery Air data test indicator, model CPA2501 2 m (6 ft) power cord Operating instructions A2LA calibration certificate Accessories Options Reference pressure sensor model CPR8001 DKD/DAkkS calibration certificate 19" rack mounting with side panels for a single instrument 19" rack mounting with side panels for two instruments side by side Barometric reference Calibration sled Robust transport case Pressure adapters Interface cable Ordering information Model / Case type / Reference pressure sensor / Barometric reference / Type of certificate for barometric reference / Additional ordering information 2016 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA data sheet CT 29.02 04/2016 04/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de