Additional Requirements



Similar documents
Control and Indicating Equipment

COMITÉ EUROPÉEN DES ASSURANCES

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Integrated Alarm Systems

VdS 5473en : (01) Video Surveillance Systems (CCTV)

Metal Pressfitting Pipe Systems

NZS 4512:2010. New Zealand Standard. Fire Detection and Alarm Systems in Buildings. Superseding NZS 4512:2003 NZS 4512:2010

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

Pay and Display Ticket Machines

WIRELESS MAGNETIC CONTACT

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

Distributed Temperature Sensing - DTS

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment

aseries A13B Mini Bullet Camera User Manual

Intruder Alarm System

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

MOUNTING AND OPERATING INSTRUCTIONS

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Notes on the certification and surveillance of management systems for companies with subsidiaries

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

VdS Guidelines for the Certification of quality management systems

TECHNICAL TBR 12 BASIS for December 1993 REGULATION

Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network

AlarmSense 2-wire detection and alarm system. Product Guide

BS5839 Part 1:2002 Overview

TECHNICAL TBR 14 BASIS for April 1994 REGULATION

ÖNORM EN Valve proving systems for automatic shut-off valves for gas burners and gas appliances

Analogue addressable devices

wireless alarm system reliable protection for small-size buildings

TEST REPORT EN (1997) +A1 (2001)

Conventional Fire Detection and Extinguishant Control System Specification

Espotel Test Laboratory Services. November 20, 2014

500r+ Installation and User Guide

QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2

Australian Standard. Intruder alarm systems. Part 1: Systems installed in client s premises AS

INTERNATIONAL STANDARD

720r Addendum: Siting the 720r

My home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.

US Installation Manual Smappee Monitor

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

MINERVA MX MX Virtual Multi-Sensor Detectors

ICP-CP500. User's Guide ICP-CP500 Codepads

Three-phase monitoring relay CM-PFE

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Overview of Standards for CO Detection Products

Experience with taximeters with a look at the corresponding tables

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Certification of construction products - Fire dampers. Certification Rules 032

Measuring electric and magnetic fields

RRV934. Multi-controller. Synco living

MNS is Switchgear System Technical Overview

ABUS WIRELESS ALARM SYSTEM

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

CLASSIFICATION NOTES

SERIES 65 ENGINEERING PRODUCT GUIDE


Compliance Schedules and Building Warrant of Fitness

N4385A / N4386A Distributed Temperature System (DTS)

REMOTE TERMOMETER TE 219 LED USER MANUAL

File:Quality-Management Manual-V2

Frequency selective monitoring and logging of environmental electromagnetic fields

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

DLP-PU/E Instruction Manual

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Iophic Smoke Detection Technology. An Introduction. Universal Security Instruments. Over 40 Years of Residential & Commercial Safety Innovations

DLO1191 Linear smoke detector

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Drayton Digistat +2RF/+3RF

Display reliable quality in safety and security products: With VdS Europe s No. 1 certification mark.

AXIS T81B22 DC 30W Midspan

CORESTA RECOMMENDED METHOD Nº 81

VEGA Analogue Addressable Control Panels

radio fire alarm system Installed with minimum disruption Provides maximum protection

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Continuous, remote monitoring and logging of electromagnetic fields

White Paper Product Quality Fujitsu ESPRIMO PCs, Fujitsu CELSIUS workstations, Fujitsu FUTRO thin clients

40 Years of experience in EMC testing

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

FIRE DETECTION AND ALARM SYSTEMS

FIRE CODE INTERPRETATION

Fire Alarm Systems Care and Maintenance

Standard the the Raising

Type: DILM32 10(24V50HZ) Article No.:

fulfils all requirements for medium protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

tel ; fax

I.S :2013 Fire Detection & Alarm Systems

Redundancy Module QUINT-DIODE/40

SYSTEM DESCRIPTION Termination Boards

fulfils all requirements for extended protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

SECURIT 800L+ CONTROL PANEL

TK800-Series Industrial GPRS / UMTS / LTE Router

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Transcription:

VdS Guidelines for Smoke Alarm Devices VdS 3131en Requirements and Test Methods VdS 3131en : 2010-05 (01)

Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 174 50735 Köln, Germany Phone: +49 221 77 66-0, Fax: +49 221 77 66-341 Copyright by VdS Schadenverhütung GmbH. All rights reserved.

VdS 3131en : 2010-05 (01) VdS Guidelines for Smoke Alarm Devices Requirements and Test Methods Content 1 General... 4 1.1 Scope... 4 1.2 Validity... 4 2 Normative references... 4 3 Definitions... 4 4 Requirements... 5 4.1 General... 5 4.2 Requirements and test methods... 5 3

VdS 3131en : 2010-05 (01) 1 General Tests according to these guidelines shall only be carried out by a testing authority accredited in accordance with DIN EN ISO/IEC 17025. Apart from the fulfilment of the following requirements, these guidelines require regular market surveillance. 1.1 Scope These guidelines specify requirements, test procedures and performance characteristics for smoke alarm devices to be used in residential areas inside buildings which apply in addition to those of European standard EN 14604 harmonised in accordance with the Construction Products Law of the European Union. They are binding only if their application is agreed in each individual case. Otherwise, these guidelines are nonbinding; any agreement to apply these guidelines is strictly optional. 1.2 Validity These guidelines become valid as from their publication. 2 Normative references These guidelines incorporate dated and undated references to other publications (e.g. European standards EN) which are listed hereafter. For dated references to other publications, subsequent amendments to or revisions of any of these publications apply only when incorporated by amendment of these guidelines. For undated references the latest edition of the publication referred to applies. DIN 14676 Smoke alarm devices for use in residential buildings, apartments and rooms with similar purposes Installation, use and maintenance, 2006-08 DIN EN 54-7 Fire detection and fire alarm systems Part 7: Smoke detectors Point detectors using scattered light, transmitted light or ionisation, 2006-09 DIN EN 14604 Smoke alarm devices, 2009-02 DIN EN 50130-4 Alarm systems; Part 4: Electromagnetic compatibility; Product family standard: Immunity requirements for components of fire, intruder and social alarm systems VdS 3515 Guidelines for smoke alarms using radio links, 2005-05 IPC-A-610D DE, 2005 : 02 Acceptability of electronic assemblies 3 Definitions For the use of these guidelines the definitions of DIN EN 14604 : 2009 and DIN EN 54-7 : 2006 apply. 4

VdS 3131en : 2010-05 (01) 4 Requirements For compliance with these guidelines the smoke alarm devices shall fulfil the following: the relevant requirements of product standard DIN EN 14604 : 2009-02 and the requirements of these guidelines. 4.1 General The general testing and connecting conditions in accordance with DIN EN 14604 Cl. 5.1.1 to 5.1.6 apply. The test schedule specified in DIN EN 14604 Cl. 5.1.7 shall be applied in all relevant issues. The applicant submits at least 20 specimens. These specimens shall be representative for the production in this place of manufacture as regards design and calibration. The applicant also submits the following: documentation as required in Standard IPC-A-610D DE, 2005 : 02, and manufacturer s declaration that the production is in accordance with Standard IPC-A- 610D DE, 2005 : 02, Class 2. Appropriate documents such as quality plan, working and testing instructions, etc. shall be submitted. 4.2 Requirements and test methods 4.2.1 Battery service life 4.2.1.1 Requirements The battery service life shall be at least 10 years. The batteries shall be fixed and not easily replaceable. 4.2.1.2 Test method The verification of the manufacturer s specifications corresponds to the procedure specified in DIN EN 14604 Cl. 4.15, but for an increased period of time in accordance with the battery service life specified by the manufacturer, however at least for a battery service life of 10 years. 4.2.2 Undercutting of supply voltage at which a battery fault warning is given 4.2.2.1 Requirements An undercutting of the threshold for battery fault warnings shall not cause an alarm signal. 4.2.2.2 Test method Based on the voltage (V E ) at which a fault warning is given (DIN EN 14604 Cl. 5.16) the supply voltage V is reduced in increments of 0,1 V per minute down to supply voltage 0 V. 5

VdS 3131en : 2010-05 (01) 4.2.3 Protection against the ingress of foreign bodies 4.2.3.1 Requirements The smoke alarm device shall be designed such that a sphere of diameter (1,3 ± 0,05) mm and a bar-shaped access probe with rectangular profile and edge length (1,0 ± 0,05) mm x (2,0 ± 0,05) mm cannot pass into the measuring chamber. 4.2.3.1 Test method The required performance characteristics are checked theoretically on the basis of the documentation, visually and/or by testing the submitted smoke alarm devices. 4.2.4 Damp heat, steady state (endurance 21 days) 4.2.4.1 Requirement The relation of the response threshold values mmax : mmin shall not exceed 1,6. Operation of the routine test facility (DIN EN Cl. 4.10) shall activate the sounder. 4.2.4.2 Test method The test method corresponds to DIN EN 14604 Cl. 5.9, but with increased severity regarding the duration (21 days). In addition, after the climatic conditioning and a recovery period of at least one hour the routine test facility (test button) shall be activated. 4.2.5 Sulphur dioxide (SO 2 ) corrosion (endurance 21 days) 4.2.5.1 Requirement The relation of the response threshold values mmax : mmin shall not exceed 1,6. Operation of the routine test facility (DIN EN Cl. 4.10) shall activate the sounder. 4.2.5.2 Test method The test method corresponds to DIN EN 14604 Cl. 5.10, but with increased severity regarding the duration (21 days). In addition, after the corrosion conditioning and a recovery period of at least one hour the routine test facility (test button) shall be activated. 4.2.6 Shock (operational) 4.2.6.1 Requirement The relation of the response threshold values measured before and after the conditioning mmax : mmin shall not exceed 1,6. Operation of the routine test facility (DIN EN 14604 Cl. 4.10) shall activate the sounder. 4.2.6.2 Test method The test method corresponds to DIN EN 54-7 Cl. 5.13. In addition, after the mechanical conditioning the routine test facility (test button) shall be activated. Note: The tests Shock and Vibration may be combined. In this case, the response threshold value is measured after these two tests in accordance with the procedure specified in DIN 14604 Cl. 5.12. 6

VdS 3131en : 2010-05 (01) 4.2.7 Electromagnetic compatibility (EMC), Immunity tests, Radiated electromagnetic fields 4.2.7.1 Requirement The relation of the response threshold values mmax : mmin shall not exceed 1,6. 4.2.7.2 Test method The test method corresponds to DIN EN 14604 Cl. 5.14 c) Radiated electromagnetic fields (operational), however, in the test according to Cl. 5.14 c) Radiated electromagnetic fields the field strength in the range (890-960) MHz is increased to 30 V/m. The increment of the cycle is 3 MHz. 4.2.8 Temperature cycle test 4.2.8.1 Requirement During the conditioning the specimen shall not give an alarm signal. The relation of the response threshold values measured before and after the conditioning mmax : mmin shall not exceed 1,6. 4.2.8.2 Test method The specimen is stabilised at (25 ± 2) C and the following temperature cycle is applied 10 times: a) raise the temperature to (65 ± 2) C in (2 ± 0,5) h; b) hold the temperature at (65 ± 2) C until 8,5 h after the beginning of the cycle; c) reduce the temperature to ( 10 ± 2) C in (4 ± 1) h; d) hold the temperature at ( 10 ± 2) C until 19,5 h after the beginning of the cycle; e) raise the temperature to (25 ± 2) C in (2 ± 0,5) h; f) hold the temperature at (25 ± 2) C until 24 h after the beginning of the cycle. After this temperature cycle conditioning has been applied, the response threshold value of the smoke alarm device shall be measured in accordance with EN 14604 Cl. 5.1.5. 7