INSTALLATION GUIDE BNC-2110 BNC Adapter for E/M/S Series and Analog Output Series Devices

Similar documents
How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI USB-5681 RF Power Meter Specifications

NI-DAQ mx Base 3.x. Contents GETTING STARTED GUIDE

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices.

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

NI 653x Cable Adapter

NI 6034E/6035E/6036E Family Specifications

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

CompactRIO crio-9052

NI USB-6008/6009 OEM USER GUIDE

DAQ. SCB Pin Shielded Connector Block User Manual. SCB-68 Shielded Connector Block User Manual. December 2002 Edition Part Number B-01

Digital input modules

DAQ. NI SCB-68A User Manual. 68-Pin Shielded Connector Block. ni.com/manuals. NI SCB-68A User Manual. August A-01

Unpack and Install the Devices, Accessories, and Cables

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

Analog Servo Drive 25A8

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

TX OPEN RS232/485 module

CompactLogix Power Supplies Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

NI 9211 Datasheet DATASHEET. 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

1701/22 FieldMonitor Management Interface Module

NI USB-9215 Series. Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 VDC, 16-Bit Simultaneous Sampling Analog Input Devices

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

AXIS T81B22 DC 30W Midspan

PCI/PXI ETHERNET ADAPTERS

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

PXI Express Chassis with Integrated MXI-Express Remote Controller

Electronic Control Devices The European Product Catalogue 2007

Kvaser Mini PCI Express User s Guide

DAQ Getting Started Guide

Contents. SPECIFICATIONS AND FEATURES GUIDE NI Serial Hardware

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

R60 USB to CAN interface Manual (1.5 EN)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

PicoScope 3000 Series

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

DC Electronic Loads 8500 series

Set Up Your MXI -Express x1 System

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Pocket Tach 99 (PT99) Non-Contact Tachometer

NI-XNET Hardware and Software

ECONseries Low Cost USB DAQ

MACTek Corporation. USB HART Interface. Users Manual

Model SPDT Relays

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

HP UPS R1500 Generation 3

USB-to-Data Highway Plus Cable

FIELDPOINT BUS EXTENDER CABLE

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

NI InsightCM Server Version 1.0

User Manual Revision English

Model 1756 Test Lead Kit

NI PXI Installing Your PXI Board INSTALLATION GUIDE

S-series Mass Connection Solutions

Power Supply Guide Version 1.0 for D-Show

aseries A13B Mini Bullet Camera User Manual

R&S ZNC Vector Network Analyzer Specifications

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

How To Use Vision Builder Ai With An Inspection System

MCR1900 Media Converter 19-Slot Chassis

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

STRATO LED Drivers 70W, Single output

USB-AD16f Data acquisition system (USB)

Redundancy Module QUINT-DIODE/40

Dear Customer! Thank you for choosing our product.

USB-AD14f Data Acquisition System (USB)

Communication bridge Xcom-MS User Manual

PIO-32.PCI User Manual

Duct Humidity Transmitter

Data Acquisition in LabVIEW

Installation guide H A. HSI hardwired system interface

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DATENBLATT USB-DIO32HS USB-DIO32HS-OEM. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

LabVIEW DSP Test Integration Toolkit for TI DSP

MADRIX NEO Quick Start Guide & User Manual

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

VFS24/32HDIP. Public Display IP Monitor User Manual

Set Up Your MXI -Express x4 System

Coupling Microsoft Excel with NI Requirements Gateway

Power Supplies 3. SDN-P DIN Rail Series

Introduction to Data Acquisition

NI Multisim Analog Devices Edition

PCI230+ & PCI260+ MULTI-FUNCTION ANALOG AND DIGITAL INPUT/OUTPUT BOARDS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

System Overview and Terms

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Universal Serial Bus (USB) to DH-485 Interface Converter

NX safety stand-alone

Transcription:

INSTALLATION GUIDE BNC-2110 BNC Adapter for E/M/S Series and Analog Output Series Devices Contents Conventions This installation guide describes how to install and configure your BNC-2110 accessory with 68-pin or 100-pin E/M/S Series or 68-pin NI 671x/672x/673x Analog Output (AO) Series multifunction data acquisition (DAQ) devices. This document also contains accessory specifications. The BNC-2110 is ideal for simplifying connections between your measurement apparatus and your DAQ device in laboratory, test, and production environments. The BNC-2110 has the following features: 15 BNC connectors for analog input, analog output, trigger/counter functions, and user-defined signals A spring terminal block with 30 pins for digital and timing I/O signal connections A 68-pin I/O connector that connects to multifunction DAQ devices Can be used on a desktop or mounted on a DIN rail Conventions... 1 What You Need to Get Started... 2 Installing the BNC-2110... 3 Connecting Differential Analog Input Signals (E/M/S Series Devices Only)... 5 Measuring Floating Signals... 5 Measuring Ground-Referenced Signals... 5 Connecting Analog Output Signals... 6 Connecting APFI 0/AO EXT REF Signals... 6 Connecting Trigger/Counter Signals... 7 Connecting Digital and Timing I/O Signals... 7 Using the USER 1 and USER 2 BNC Connectors... 9 Specifications... 10 The following conventions are used in this document: <> Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name for example, AO <3..0>.» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on a product, refer to the Read Me First: Safety and Radio-Frequency Interference document for information about precautions to take.

bold italic monospace Platform Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. Text in this font denotes a specific platform and indicates that the text following it applies only to that platform. What You Need to Get Started To set up and use your BNC-2110 accessory, you need the following: BNC-2110 BNC adapter(s) 1 BNC-2110 Installation Guide One of the following DAQ devices: 68-pin AO/E/M/S Series device (with one or two I/O connectors) 2 100-pin E Series device Cable(s) for DAQ device(s), as listed in Table 1 The Analog Output Series User Manual, the E Series User Manual, the M Series User Manual, or the S Series User Manual BNC cables Small flathead screwdriver 28 16 AWG wire Wire strippers 1 You can use two BNC-2110 accessories with both connectors of NI 6224/6229/6254/6259/6284/6289 M Series devices. 2 On two-connector AO Series and NI 6225/6255 devices, you cannot use the device s second connector with the BNC-2110. BNC-2110 Installation Guide 2 ni.com

Installing the BNC-2110 Figure 2 shows the front panel of the BNC-2110. T INST NA R IO U N M A E L NTS 3 1 2 4 5 3 6 7 1 Analog Input/Analog Output BNC Connectors 2 FS/GS Switches 3 Terminal Block Retaining Screws 4 Digital and Timing I/O Spring Terminal Blocks 5 Power Indicator Light 6 Trigger/Counter BNC Connectors 7 User-Defined Signals BNC Connectors Figure 1. BNC-2110 Front Panel To connect the BNC-2110 to your DAQ device, complete the following steps. Consult your computer or PXI/PXI Express chassis user manual for specific instructions and warnings. Note If you have not already installed your DAQ device, refer to the DAQ Getting Started Guide for instructions. Caution Do not connect the BNC-2110 to any device other than National Instruments AO/E/M/S Series multifunction DAQ devices. Doing so can damage the BNC-2110, the DAQ device, or the host computer. National Instruments is not liable for damage resulting from these connections. National Instruments Corporation 3 BNC-2110 Installation Guide

1. Place the BNC-2110 near the host computer or PXI/PXI Express chassis or use the optional DIN Rail Mounting kit for UMI-FLEX-6 and BNC boxes (part number 777972-01), which you can order from National Instruments at ni.com. Caution Do not connect input voltages greater than 42.4 V pk /60 VDC to the BNC-2110. The BNC-2110 is not designed for any input voltages greater than 42.4 V pk /60 VDC, even if a user-installed voltage divider reduces the voltage to within the input range of the DAQ device. Input voltages greater than 42.4 V pk /60 VDC can damage the BNC-2110, all devices connected to it, and the host computer. Overvoltage can also cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse. 2. Connect the BNC-2110 to the DAQ device using the appropriate cable for your DAQ device, as listed in Table 1. Table 1. BNC-2110 Cabling Options Number of Pins DAQ Device Recommended Cable(s) 68-pin NI 6715 AO Series DAQCard E Series NI PCI/PCIe/PXI/PXIe M Series * NI 6143 S Series NI 672x AO Series NI 6711/673x AO Series PCI/PXI E Series USB Mass Termination M Series * NI 6110/6111/612x/613x S Series NI 6713 AO Series NI 6115/6120 S Series SHC68-68-EPM or RC68-68 SH68-C68-S SH68-68-EP or R6868 SH68-68-EP 100-pin PCI/PXI E Series SH1006868 * You cannot connect the BNC-2110 to Connector 1 of NI 6225/6255 devices. You cannot connect the BNC-2110 to the AO 8 31 Connector of NI 6723 devices. The power indicator light, shown in Figure 1, lights. If it does not light, check the cable and wiring connections. 3. Launch Measurement & Automation Explorer (MAX), confirm that your DAQ device is recognized, and configure your device settings. Refer to the DAQ Getting Started Guide for more information. 4. Connect signals to the BNC connectors and spring terminal block as described in the following sections. Note With NI-DAQmx, National Instruments has revised its terminal names so they are easier to understand and more consistent among NI hardware and software products. The revised terminal names used in this document are usually similar to the names they replace. For a complete list of Traditional NI-DAQ (Legacy) terminal names and their NI-DAQmx equivalents, refer to the Terminal Name Equivalents table in the NI-DAQmx Help. 5. Test specific device functionality, such as the ability to send and receive data with MAX test panels. Refer to the DAQ Getting Started Guide for more detailed information about running test panels in MAX. BNC-2110 Installation Guide 4 ni.com

When you have finished using the BNC-2110, power off any external signals connected to the BNC-2110 before you power off your computer. Connecting Differential Analog Input Signals (E/M/S Series Devices Only) Use the BNC-2110 BNC connectors on the front panel to connect AI <0..7> signals to E/M/S Series DAQ devices. The BNC-2110 is only intended for differential analog input signals. The number of connectors you use depends on your DAQ device and application. Complete the following steps to measure a differential (DIFF) analog input signal. 1. Connect the BNC cable to one of the AI <0..7> BNC connectors on the front panel. 1 2. Configure your software to measure this channel differentially. 3. Move the FS/GS switch to the applicable position, depending on whether you are measuring a floating source (FS) or ground-referenced source (GS) analog input signal. Refer to the Measuring Floating Signals and Measuring Ground-Referenced Signals sections for more information about these signal sources. Measuring Floating Signals To measure floating signal sources, move the corresponding switch below the BNC connector to the FS position. In the floating source switch position, the DAQ device s amplifier negative terminal connects to ground through a 5 kω resistor in parallel with a 0.1 μf capacitor, as shown in Figure 2. Refer to your DAQ device documentation for more information about measuring floating signals. Signal Source BNC-2110 DAQ Device (Differential Input Mode) + FS 0.1 μf FS Mode 5 kω + AI GND Figure 2. Measuring a Floating Signal Source Measuring Ground-Referenced Signals To measure ground-referenced signals, move the switch below the BNC connector for the AI channel you are using to the GS position. Using the ground-referenced source switch position avoids ground loops, as shown in Figure 3. Refer to your DAQ device documentation for more information about measuring ground-referenced signals. 1 When using the BNC-2110 with Connector 1 of NI 6224/6229/6254/6259/6284/6289 devices, the AI <0..7> BNCs on the BNC-2110 map to the AI <16..23> channels on the M Series device. National Instruments Corporation 5 BNC-2110 Installation Guide

Signal Source BNC-2110 DAQ Device (Differential Input Mode) + GS 0.1 μf GS Mode + 5 kω AI GND Connecting Analog Output Signals Figure 3. Measuring a Ground-Referenced Signal Source Use the BNC-2110 BNC connectors on the front panel to connect AO <0..7> signals to your DAQ device. The number of connectors you use depends on your DAQ device and application. E/M/S Series DAQ devices can only use the AO <0..1> BNCs. 1 AO Series DAQ devices can use the AO <0..1> and the AO <2..7> BNCs. Refer to your DAQ device documentation for information about the use of these signals. Note (AO Series Devices Only) When using connectors AO <2..7>, you must move the associated FS/GS switch(es) to the FS position. Connecting APFI 0/AO EXT REF Signals Use the BNC-2110 BNC connectors on the front panel to connect the analog programmable function interface channel, APFI 0, to your M Series DAQ device or analog output external reference, AO EXT REF, to your AO/E/S Series device. 2 The AO EXT REF BNC is the external reference input for the AO circuitry. With some M Series devices, the APFI 0 channel can be used as the external reference input for the AO circuitry, the external offset for the AO circuitry, or the analog trigger input. These functions are not available on all devices. Whether you can use this BNC depends on your DAQ device and application. Refer to your DAQ device documentation for information about the use of these signals. 1 When using the BNC-2110 with Connector 1 of NI 6229/6259/6289 devices, the AO <0..1> BNCs on the BNC-2110 map to the AO <2..3> channels on the M Series device. 2 When using the BNC-2110 with Connector 1 of NI 6254/6259/6284/6289 devices, the APFI 0 BNC on the BNC-2110 maps to the APFI 1 channel on the M Series device. BNC-2110 Installation Guide 6 ni.com

Connecting Trigger/Counter Signals Use the BNC-2110 BNC connectors on the front panel to connect PFI 0/P1.0 (AI START TRIG) and PFI 12/P2.4 (CTR 0 OUT) signals to your DAQ device. The number of connectors you use depends on your DAQ device and application. Refer to your DAQ device documentation for information about the use of these signals. Table 2 describes the trigger/counter BNCs. Table 2. Trigger/Counter Signal Descriptions BNC Description PFI 0/P1.0 Programmable Function Input channel 0 or Port 1 Digital Input/Output channel 0 AI START TRIG (AI Start Trigger Signal) As an output, this pin is the ai/starttrigger signal. In post-trigger DAQ sequences, a low-to-high transition indicates the initiation of the acquisition sequence. In applications with pre-trigger samples, a low-to-high transition indicates the initiation of the pre-trigger samples. PFI 12/P2.4 Programmable Function Input channel 12 or Port 2 Digital Input/Output channel 4 CTR 0 OUT (Counter 0 Output Signal) As an input, this pin can be used to route signals directly to the RTSI bus. As an output, this pin emits the Ctr0InternalOutput signal. Connecting Digital and Timing I/O Signals Use the BNC-2110 spring terminal block on the front panel to connect digital and timing I/O signals to your DAQ device. Refer to your DAQ device documentation for information about the use of these signals. When connecting signals to the spring terminals, you can use 28 16 AWG wire with the insulation stripped to 0.28 in. Table 3 describes the digital terminals on the front panel of the BNC-2110. National Instruments Corporation 7 BNC-2110 Installation Guide

Table 3. Digital and Timing I/O Terminal Descriptions Terminal PFI <1..7>/ P1.<1..7> PFI <8..9>/ P2.<0..1> Description Programmable Function Input channels 1 through 7 or Port 1 Digital Input/Output channels 1 through 7 Programmable Function Input channels 8 through 9 or Port 2 Digital Input/Output channels 0 through 1 PFI 10/P2.2 Programmable Function Input channel 10 or Port 2 Digital Input/Output channel 2 EXT STROBE (External Strobe Signal) You can toggle this output with software controls to latch signals or trigger events on external devices PFI 11/P2.3 * Programmable Function Input channel 11 or Port 2 Digital Input/Output channel 3 AI HOLD COMP (AI Hold Complete Event Signal) When enabled, this signal pulses once for each A/D conversion in sampling mode. The low-to-high edge indicates when the input signal can be removed from the input or switched to another signal. PFI 13/P2.5 Programmable Function Input channel 13 or Port 2 Digital Input/Output channel 5 CTR 1 OUT (Counter 1 Output Signal) As an input, this pin can be used to route signals directly to the RTSI bus. As an output, this pin emits the Ctr1InternalOutput signal. PFI 14/P2.6 Programmable Function Input channel 14 or Port 2 Digital Input/Output channel 6 FREQ OUT (Frequency Output) This output is from the frequency generator P0.<0..7> USER <1..2> Port 0 Digital Input/Output channels 0 through 7 You can individually configure each signal as an input or output. P0.6 and P0.7 can control the up/down signal of general-purpose Counters 0 and 1, respectively Digital Ground This terminal supplies the reference for the digital signals at the I/O connector as well as the +5 VDC supply User-Defined 1 and 2 Internally routed to USER 1 or USER 2 BNC, this terminal provides a user-definable BNC terminal. Refer to the Using the USER 1 and USER 2 BNC Connectors section for more information about using these signals. +5 V +5 V Power Source These terminals are fused on the DAQ device; the current available depends on the device to which it is connected. Refer to your DAQ device specifications for more information. AI GND * AI SENSE *, Analog Input Ground The analog input voltages are referenced to this node Analog Input Sense This terminal is the reference node for channels AI <0..15> in non-referenced single-ended (NRSE) configurations * E/M/S Series devices only. Single-ended mode is not recommended on the BNC-2110. BNC-2110 Installation Guide 8 ni.com

Using the USER 1 and USER 2 BNC Connectors The USER 1 and USER 2 BNC connectors allow you to use a BNC connector for a digital or timing I/O signal of your choice. The USER 1 and USER 2 BNC connectors are routed (internal to the BNC-2110) to the USER 1 and USER 2 spring terminals, as shown in Figure 4. Internal Connection PFI 9/P2.1 PFI 8/P2.0 PFI 7/P1.7 PFI 6/P1.6 PFI 5/P1.5 PFI 4/P1.4 PFI 3/P1.3 PFI 2/P1.2 PFI 1/P1.1 USER 2 PFI 14/P2.6 +5V +5V DIGITAL AND TIMING I/O Spring Terminal Block P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0 PFI 13/P2.5 USER 1 PFI 11/P2.3 PFI 10/P2.2 AI SENSE AI GND Internal Connection USER 1 BNC USER 2 BNC Figure 4. USER <1..2> BNC Connections Figure 5 shows an example of how to use the USER 1 and USER 2 BNCs. To access the PFI 8 signal from a BNC, connect USER 2 on the spring terminal block to PFI 8/P2.0 with a wire. National Instruments Corporation 9 BNC-2110 Installation Guide

PFI 9/P2.1 PFI 8/P2.0 PFI 7/P1.7 PFI 6/P1.6 PFI 5/P1.5 PFI 4/P1.4 PFI 3/P1.3 PFI 2/P1.2 PFI 1/P1.1 USER 2 PFI 14/P2.6 +5V +5V DIGITAL AND TIMING I/O Spring Terminal Block USER 2 BNC P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 Wire P0.1 P0.0 PFI 13/P2.5 USER 1 PFI 11/P2.3 PFI 10/P2.2 AI SENSE AI GND Internal Connection BNC Cable PFI 8 Signal Specifications Figure 5. Connecting PFI 8 to USER 2 BNC The designated space below each USER <1..2> BNC is for marking or labeling signal names. This section lists the specifications of the BNC-2110. These specifications are typical at 25 C unless otherwise specified. Note Refer to your DAQ device documentation for specifications about analog input, analog output, trigger/counter, and digital and timing I/O signals. Physical Dimensions...19.05 cm 10.48 cm 3.51 cm (7.5 in. 4.125 in. 1.38 in.) Weight...798 g (1 lb 12.1 oz) BNC connectors...15 Spring terminal block...30 positions Wire gauge...28 16 AWG wire I/O connector...68-pin SCSI male connector Environment Operating temperature...0 to 70 C Storage temperature... 55 to 125 C Relative humidity...5 to 90%, noncondensing BNC-2110 Installation Guide 10 ni.com

Pollution Degree (indoor use only)...2 Maximum altitude...2,000 m Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: EN 61326 EMC requirements; Minimum Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note For EMC compliance, operate this device according to product documentation. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/ environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) National Instruments Corporation 11 BNC-2110 Installation Guide

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 1998 2007 National Instruments Corporation. All rights reserved. 372121F-01 Oct07