3. Listed [grease] [dishwasher] [grease and dishwasher] ducts.

Similar documents
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

SECTION GROUND WATER STORAGE TANKS

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

FINAL December 2012 SECTION DUCTWORK

ASX7-4-IOM-7 J

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

SECTION STANDING SEAM METAL ROOFING

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION WINDOW WASHING SYSTEMS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

2010 Residential Water Heater Replacement Check List

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Saf-T Vent EZ Seal 3" and 4" (75mm and 100mm) Diameter Special Gas Vent (Type BH Class I/II) & Gas Vent Connector

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

SECTION PREFORMED METAL STANDING SEAM ROOFING

SECTION STORM DRAINAGE SYSTEM

Section 2100-Trenching and Tunneling

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Preformed Metal Roofing and Siding

SECTION POLYVINYL CHLORIDE (PVC) PIPE

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Wastewater Capital Projects Management Standard Construction Specification

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, USA. Venting Guide

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Mechanical Installation

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

4 Installation Requirements

PART 1 GENERAL 1.1 SECTION INCLUDES

DENVER MODEL 30 X 30 SPECIFICATIONS

DESIGN CLARIFICATION (DC)

Installation Instructions

CHAPTER 5 WATER HEATERS

SECTION MORTUARY REFRIGERATORS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

READ AND SAVE THESE INSTRUCTIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION HEAT PUMPS

2. Division 05 Structural Steel Framing for steel framework requirements

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 22 LIGHTNING PROTECTION SYSTEM

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Fire Barrier Duct Wrap 15A

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

CHIMNEYS AND FIREPLACES

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU MECHANICAL PLAN REVIEW CHECKLIST

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

City of San Diego, CWP Guidelines

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

SECTION PIPE HANGERS AND SUPPORTS

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

SECTION PRECAST CONCRETE STRUCTURES

How To Make A House Safe

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

SECTION FIRE HYDRANTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Residential Deck Safety, Construction, and Repair

SECTION CHAIN LINK FENCES AND GATES

SECTION STORM DRAINAGE TABLE OF CONTENTS

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

KITCHEN HOODS GUIDELINES

Excerpts from the Canadian National Building Code (NBC)

Cooktop Low-Profile Ventilation Hoods

COLORADO MODEL. 35 x 65 SPECIFICATIONS

city of edmonds development information

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Section SEWER PIPE INSTALLATION AND TESTING

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 1 GENERAL REQUIREMENTS

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

How To Install A Perfect 16 Id Series Filter System

City of Elk River BASEMENT Office Use Only

Transcription:

SECTION 23 51 00 BREECHINGS, CHIMNEYS, AND STACKS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. B. Specifications throughout all Divisions of the Project Manual are directly applicable to this Section, and this Section is directly applicable to them. 1.02 SUMMARY A. This Section includes the following: 1. Listed double-wall [vents] [chimneys]. 2. Field-fabricated metal breechings [and chimneys]. 3. Listed [grease] [dishwasher] [grease and dishwasher] ducts. 1.03 REFERENCE STANDARDS A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. B. All reference amendments adopted prior to the effective date of this Contract shall be applicable to this Project. C. All materials, installation and Workmanship shall comply with the applicable requirements and standards addressed within the following references: 1. NFPA: Comply with NFPA 211 "Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances". 2. UL: Comply with applicable portions of UL safety standards; provide products which have been UL listed and labeled. 3. SMACNA: Comply with SMACNA Low Pressure Duct Standards for fabricated breeching and smokepipe. 4. AWS: Comply with AWS Structural Welding Code for welders' qualifications, welding details, and Workmanship standards. 5. ASHRAE: Comply with the ASHRAE Equipment Handbook, Chapter 27, for Chimney, Gas Vent, and Fireplace Systems, material requirements and design criteria. 1.04 QUALITY ASSURANCE A. Source Limitations: Obtain listed system components through one source from a single manufacture. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 1

B. Welding: Qualify processes and operators according to AWS D1.1, "Structural Welding Code--Steel," for hangers and supports and AWS D9.1, "Sheet Metal Welding Code," for shop and field welding of joints and seams in vents, breechings, and stacks. C. Certified Sizing Calculations: Manufacturer shall certify venting system sizing calculations. 1.05 SUBMITTALS A. Product Data: Furnish product data for the following: 1. Type B and BW vents. 2. Type L vents. 3. Special gas vents. 4. Building-heating-appliance chimneys. 5. Grease ducts. 6. Guy wires and connectors, and installation details. B. Record Documents: 1. Shop Drawings for vents, breechings, chimneys, and stacks. Include Drawings, elevations, Sections, details, and attachments to other Work. 2. Details equipment assemblies which indicate dimensions, weights, loads, required clearances, methods of field assembly, components, hangers and restraints, including the location and the size of each field connection. 3. For installed products indicated to comply with design loads, include calculations and structural analysis data signed and sealed by the qualified professional engineer responsible for their preparation. 4. Welding certificates. 1.06 DELIVERY, STORAGE AND HANDLING A. The Work of this Section shall be coordinated with other trades affecting, or affected by this Work, to assure the steady progress of all Work performed under the Contract. B. Replace any Sections or assemblies damaged during shipment, storage or handling with new identical factory-supplied components. C. Protect finishes from physical damage by leaving factory packing cases in place before installation and providing temporary protective covers after installation with on going construction within the Project Site. 1.07 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of venting system that fail in materials or Workmanship within specified warranty period. Failures include, but are not limited to, structural failures caused by expansion and contraction. B. Warranty Period: [10] [15] [25] <Insert number> years from date of Substantial Completion. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 2

PART 2 - PRODUCTS 2.01 GENERAL A. All materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. 2.02 MANUFACTURERS A. American Metal Products; MASCO Corporation. B. Metal-Fab, Inc. C. ProTech Systems Inc. (Special Gas Vent) ( Grease Ducts). D. Heat-Fab Inc (Special Gas Vent) ( Grease Ducts). E. Selkirk Inc.; Selkirk Air Mate. F. Simpson Dura-Vent Co., Inc.; Subsidiary of Simpson Manufacturing Co. G. Van-Packer Co. 2.03 LISTED TYPE B AND BW VENTS A. Description: Double-wall metal vents tested according to UL 441 and rated for [480 degrees F continuously for Type B], or [550 degrees F continuously for Type BW]; with neutral or negative flue pressure complying with NFPA 211 and suitable for certified gas-fired appliances. B. Construction: Inner shell and outer jacket separated by at least a 1/4-inch airspace. C. Inner Shell: [ASTM B 209, Type 1100 aluminum] [ASTM B 209, Type 3003 aluminum] [ASTM B 209, Type 3105 aluminum] [ASTM A 666, Type 430 stainless steel]. D. Outer Jacket: [Galvanized] [Aluminized] steel. E. Accessories: Tees, elbows, increasers, draft-hood connectors, terminations, adjustable roof same assembly. 1. Termination: Stack cap designed to exclude 90 percent of rainfall. 2. Termination: Round chimney top designed to exclude 98 percent of rainfall. 3. Termination: [Insert special type termination or delete this option from specification.] 2.04 LISTED TYPE L VENT A. Description: Double-wall metal vents tested according to UL 641 and rated for 570 degrees F continuously or 1700 degrees F for 10 minutes; with neutral or negative flue pressure complying with NFPA 211 and suitable for low-heat appliances. B. Construction: Inner shell and outer jacket separated by at least a [1/4-inch] [1-inch] [2-inch] [4-inch] airspace filled with high-temperature, [ceramic-fiber] [mineral-wool] insulation. C. Inner Shell: ASTM A 666, Type [304] [316] stainless steel. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 3

D. Outer Jacket: [Galvanized] [Aluminized] [Stainless] steel. E. Accessories: Tees, elbows, increasers, draft-hood connectors, terminations, adjustable roof same assembly. 1. Termination: Stack cap designed to exclude 90 percent of rainfall 2. Termination: Round chimney top designed to exclude 98 percent of rainfall. 3. Termination: Exit cone with drain Section incorporated into riser. 4. Termination: [Insert special type termination or delete this option from specification.] 2.05 LISTED SPECIAL GAS VENT A. Manufacturers: 1. Heat-Fab Inc. 2. Metal-Fab, Inc. 3. ProTech Systems Inc. 4. Z-FLEX. B. Description: Double-wall metal vents tested according to UL 1738 and rated for 480 degrees F continuously, with positive or negative flue pressure complying with NFPA 211 and suitable for condensing-gas appliances. C. Construction: Inner shell and outer jacket separated by at least a 1/2-inch airspace. D. Inner Shell: ASTM A 959, Type 29-4C stainless steel. E. Outer Jacket: [Aluminized] [Stainless] steel. F. Accessories: Tees, elbows, increasers, draft-hood connectors, terminations, adjustable roof same assembly. 1. Termination: Stack cap designed to exclude 90 percent of rainfall. 2. Termination: Round chimney top designed to exclude 98 percent of rainfall. 3. Termination: Exit cone with drain Section incorporated into riser. 4. Termination: [Insert special type termination or delete this option from specification.] 2.06 LISTED BUILDING-HEATING-APPLIANCE CHIMNEYS A. Description: Double-wall metal vents tested according to UL 103 and rated for 1000 degrees F continuously or 1700 degrees F for 10 minutes; with neutral or negative flue pressure complying with NFPA 211 and suitable for dual-fuel boilers, oven vents, water heaters, or exhaust for engines. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 4

B. Construction: Inner shell and outer jacket separated by at least a [1/2-inch] [1-inch] [2-inch] [3-inch] [4-inch] annular space [filled with high-temperature, ceramic-fiber insulation] C. Inner Shell: ASTM A 666, Type [304] [316] stainless steel. D. Description: Double-wall metal vents tested according to UL 103 and 959 and rated for 1400 degrees F continuously or 1800 degrees F for 10 minutes; with positive or negative flue pressure complying with NFPA 211 and suitable for dual-fuel boilers, oven vents, water heaters, or exhaust for engines. E. Construction: Inner shell and outer jacket separated by at least a [1-inch] [2-inch] [3-inch] [4- inch] annular space filled with high-temperature, ceramic-fiber insulation. F. Inner Shell: ASTM A 666, Type [304] [316] stainless steel. G. Description: Double-wall metal vents tested according to UL 103 and rated for 1000 degrees F continuously, or 2100 degrees F for 10 minutes; with neutral or negative flue pressure complying with NFPA 211 and suitable for fireplaces and other solid-fuel-burning appliances H. Construction: Inner shell and outer jacket separated by at least a [1-inch] [1-1/2-inch] [2-inch] [4-inch] annular space filled with high-temperature, ceramic-fiber insulation. I. Inner Shell: [ASTM A 666, Type 304] [ASTM A 666, Type 316] [ASTM A 240/A 240M, Type 430] stainless steel. J. Outer Jacket: [Galvanized] [Aluminized] [Stainless] steel. K. Accessories: Tees, elbows, increasers, draft-hood connectors, terminations, adjustable roof same assembly. 1. Termination: Stack cap designed to exclude 90 percent of rainfall. 2. Termination: Round chimney top designed to exclude 98 percent of rainfall. 3. Termination: Exit cone with drain Section incorporated into riser. 4. Termination: [Insert special type termination or delete this option from specification.] 2.07 LISTED GREASE DUCTS A. Description: Double-wall metal vents tested according to UL 1978 and rated for 500 degrees F continuously, or 2000 degrees F for 30 minutes; with positive or negative duct pressure and suitable for Type I, commercial kitchen grease duct. B. Construction: Inner shell and outer jacket separated by at least a [1-inch] [2-inch] [3-inch] [4- inch] annular space filled with high-temperature, ceramic-fiber insulation. C. Inner Shell: ASTM A 666, Type [304] [316] stainless steel. D. Outer Jacket: [Aluminized] [Stainless] steel. E. Accessories: Tees, elbows, increasers, hood connectors, terminations, adjustable roof same assembly. Include unique components required to comply with NFPA 96. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 5

2.08 FIELD-FABRICATED METAL BREECHINGS AND CHIMNEYS A. Fabricate freestanding chimneys according to SMACNA's "Guide for Steel Stack Design and Construction." Design for minimum <feet> high and <Insert inches> in diameter. B. Fabricate breechings and chimneys from ASTM A 569/A 569M hot-rolled steel with continuously welded joints, complying with NFPA 211 for minimum metal thickness. 1. Equal to or Less Than 1.069 Sq. Ft. or 14 Inches in Diameter: 0.053 inch. 2. Up to 1.396 Sq. Ft. or 16 Inches in Diameter: 0.067 inch. 3. Up to 1.7 Larger Than above: 0.123 inch. 4. 64 Sq. Ft. or 18 Inches in Diameter: 0.093 inch. C. Fabricate chimneys and vent connectors from galvanized steel, complying with NFPA 211 for minimum metal thickness. 1. Equal to or Less Than 6 Inches in Diameter: 0.019 inch. 2. Up to 10 Inches in Diameter: 0.024 inch. 3. Up to 16 Inches in Diameter: 0.029 inch. 4. Larger Than above: 0.056 inch. D. Fabricate chimneys and vent connectors from ASTM B 209, Type 1100 or 3003, aluminum or stainless steel, complying with NFPA 211 for the following minimum metal thicknesses: 1. Aluminum: 0.027 inch. 2. Stainless Steel: 0.012 inch. E. Fabricate cleanout doors from compatible material, same thickness as breeching, bolted and it also incorporates a gasket seal. 2.09 GUYING AND BRACING MATERIALS A. Cable: [Three] [Four] <Insert number> galvanized, stranded wires of the following thickness: 1. Minimum Cable Size: 1/4 inch in diameter. 2. For stack ID sizes 4 to 15 Inches: use 5/16 inch. 3. For stack ID sizes 18 to 24 Inches: use 3/8 inch. 4. For stack ID sizes 27 to 30 Inches: use 7/16 inch. 5. For stack ID sizes 33 to 36 Inches: use 1/2 inch. 6. For stack ID sizes 39 to 48 Inches: use 9/16 inch. 7. For stack ID sizes 51 to 60 Inches: use 5/8 inch. B. Pipe: [Two] [Three] <Insert number> galvanized steel, NPS 1-1/4. C. Angle Iron: [Two] [Three] <Insert number> galvanized steel, 2 by 2 by 0.25 inch. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 6

PART 3 - EXECUTION 3.01 PREPARATION A. Examine areas and conditions for compliance with requirements for installation tolerances and other conditions that may affect performance of Work. B. Contractor shall furnish supervision and provide labor for installation of the Work product. Contractor shall field check the Work product prior to start-up and commissioning of equipment or appliance connected to the Work product such as vents, breechings, chimneys, grease ducts or stacks. 3.02 INSTALLATION A. Vents and Chimneys: 1. Locate to comply with minimum clearances from combustibles and minimum termination heights according to product listing or NFPA 211, whichever is most stringent. 2. Seal between Sections of positive-pressure vents according to manufacturer's written installation instructions, using sealants recommended by manufacturer. 3. Support vents at intervals recommended by the manufacturer to support weight of vents and all accessories, without exceeding appliance loading. 4. Properly slope breechings in accordance with manufacturer s or Architect/Engineer recommendations, and install condensate a drain connection at the lowest point and piped to nearest drain. 5. Connect base Sections of chimneys to foundation using anchor lugs of size and number recommended by manufacturer or Architect/Engineer. 6. Join Sections with acid-resistant joint cement to provide continuous joint and smooth interior finish. 7. Erect stacks plumb to finished tolerance of no more than [1, 1.5, 1.75] < Insert number> inch out of plumb from top to bottom. B. Field-Fabricated Breechings and Chimneys: 1. Suspend breechings and chimneys independent of their appliance connections. 2. Install, support, and restrain according to manufacturer s or Architect/Engineers requirements. 3. Align breechings at connections, with smooth internal surface and maximum 1/8-inch misalignment tolerance. 4. Slope breechings down in direction of appliance, with condensate drain connection at lowest point piped to nearest drain. 5. Support breechings and chimneys from building structure with bolts, concrete inserts, steel expansion anchors, welded studs, C-clamps, or beam clamps according to manufacturer's written instructions. AE Project Number: Chimneys, Breeching and Stacks 23 51 00 7

3.03 CLEANING A. After completing system installation, including outlet fittings and devices, inspect exposed finish. Remove burrs, dirt, and construction debris and repair damaged finishes. B. Clean breechings internally, during and after installation, to remove dust and debris. Clean external surfaces to remove welding slag and mill film. Grind welds smooth and apply touchup finish to match factory or shop finish. C. Provide temporary closures at ends of breechings, chimneys, and stacks that are not completed or not completely connected to equipment or appliance. END OF SECTION 23 51 00 AE Project Number: Chimneys, Breeching and Stacks 23 51 00 8