Series 3730 Electropneumatic Positioner Type with HART communication ESD version

Similar documents
Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SPECIAL PRINT. Innovative Control Technology. Control Valve Diagnostics in Safety-instrumented Systems. A Comparison of Architectures

SIL in de praktijk (Functional Safety) Antwerpen Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.

Series 3730 Type Electropneumatic Positioner

Device Type Manager (DTM) Basic HART

Terminology and Symbols in Control Engineering

Device Type Manager (DTM) for AS800

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

Safety Requirements Specification Guideline

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

MXa SIL Guidance and Certification

AMS ValveLink SNAP-ON Application

FUNCTIONAL SAFETY CERTIFICATE

Safety Integrated. SIMATIC Safety Matrix. The Management Tool for all Phases of the Safety Lifecycle. Brochure September Answers for industry.

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

SAFETY MANUAL SIL RELAY MODULE

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

CERTIFICATE OF COMPLIANCE

SAFETY MANUAL SIL Switch Amplifier

Basic Fundamentals Of Safety Instrumented Systems

A descriptive definition of valve actuators

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

SAFETY MANUAL SIL SMART Transmitter Power Supply

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

High-precision valve control using intelligent positioners. sipart

Process automation engineering tools

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Pneumatic control loops save water and energy with fixed-bed filters

Logic solver application software and operator interface

Valves and Solenoid Valves testet and certified byrheinhold & Mahla according to IEC 61508/61511

SAFETY LIFE-CYCLE HOW TO IMPLEMENT A

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Michael A. Mitchell, Cameron Flow Control, DYNATORQUE Product Manager

Device Management Jonas Berge Emerson Process Management

How To Control An Electric Pneumatic Positioner Tzidc

FIELDBUS DIAGNOSTICS: LATEST ADVANCEMENTS OPTIMIZE PLANT ASSET MANAGEMENT

Introduction to Process Control Actuators

ISA108 Intelligent Device Management (IDM)

Failure Modes, Effects and Diagnostic Analysis

DeltaV SIS for Burner Management Systems

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Where s the Interoperability for Asset Management?

IEC Functional Safety Assessment. ASCO Numatics Scherpenzeel, The Netherlands

Partner for automation Water technology

Conditie gebaseerd onderhoud met PROFIBUS in overeenstemming met NAMUR NE107

VALcare Valve Diagnosis. for Positioners SRD991 / SRD960. Quick Guide QG EVE0501 V-(en)

Type 3353 Angle Seat Valve

PRODUCT PROFILE FEATURES

Selecting Sensors for Safety Instrumented Systems per IEC (ISA )

Measurement Products. Scalable device management Productivity enhancement that grows with your business

WELLHEAD FLOWLINE PRESSURE PROTECTION USING HIGH INTEGRITY PROTECTIVE SYSTEMS (HIPS)

ValveLink DTM ValveLink PLUG IN for PRM

SAFETY MANUAL SIL SWITCH AMPLIFIER

Intelligent Device Management: Device Diagnostics

Centro-Matic Automatic Lubrication Systems System Controls

NEW. EVEN MORE data acquisition and test stand automation

Technical Information. HART Communications. Part 4 Communications

Industrial IT Ó Melody Composer

PROFIBUS diagnostics and network monitoring

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Value Paper Author: Edgar C. Ramirez. Diverse redundancy used in SIS technology to achieve higher safety integrity

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

The Interaction of Contactors with PLCs

Final Element Architecture Comparison

SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP

Learning Systems Software Simulation

Measurement Products. FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Reduce Risk with a State-of-the-Art Safety Instrumented System. Executive Overview Risk Reduction Is the Highest Priority...

Certification Report of the STT25S Temperature Transmitter

Control Valve Training Course Program

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Programming Logic controllers

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Safety Integrity Level (SIL) Assessment as key element within the plant design

IEC Functional Safety Assessment. Project: K-TEK Corporation AT100, AT100S, AT200 Magnetostrictive Level Transmitter.

Data Sheet 10/ EN. Contrac power electronics Customer specific settings

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Signature and ISX CM870 Electronics

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

TABLE OF CONTENT

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Industrial Steam System Process Control Schemes

A methodology For the achievement of Target SIL

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Safety Manual BT50(T) Safety relay / Expansion relay

EBS852 (Contrac) Power Electronic Unit

Alarms Trips: The Ups and Downs

CONFIGURABLE SAFETY RELAYS

Integrating HART into PROFIBUS DP

MECE 102 Mechatronics Engineering Orientation

IFEA Industriell kommunikasjon. AS-i Training

Rosemount 333 HART Tri-Loop

Transcription:

Series 3730 Electropneumatic Positioner Type 3730-3 with HART communication ESD version Application Positioner for early detection of faults in SIS valves with information on predictive maintenance and partial stroke test function. The shutdown function in the event of emergency can also be implemented with the positioner certified acc. to IEC 61508. Emergency Shutdown (ESD) is a positioner function with extended firmware and partial stroke testing for the predictive, status-oriented detection of malfunctions in pneumatic shut-off valves in safety instrumented systems (SIS). The testing and diagnostic functions are completely integrated into the positioner. The positioner is based on the Type 3730-3 Positioner with HART communication. The basic functions, attachment, and technical data are identical for both positioners (no external position sensor) and are described in Data Sheet T 8384-2/3 EN also containing the ordering specifications. ESD functions can be parameterized and the test results can be read on site at the positioner and over SSP (SAMSON interface protocol) and HART communication interfaces. The user interface is integrated into TROVIS-VIEW software and FDT/ DTM engineering tools, which makes operation easier to learn. TROVIS-VIEW: Operator interface to configure and parameterize various SAMSON devices FDT: Field device tool for the manufacturer-independent integration of field devices DTM: Device type manager to describe the device properties DD: Device description for integration into process control systems and asset management systems. Special features Local operation over a rotary pushbutton and LC display Integration of safety-related limit contact, certified solenoid valve and fault alarm output in the positioner housing Limit switch to determine the CLOSED valve position or to check the partial stroke test Integrated solenoid valve for redundant emergency shutdown Integrated partial stroke test without disrupting plant operation Various cancel conditions to prevent an unwanted large change in stroke caused by the partial stroke test ESD lock to prevent unwanted intervention ESD mode, control operation or manual mode possible Time-controlled, automatic test procedure or manual triggering of the partial stroke test Extended EXPERT + diagnostics already integrated Fig. 1 Positioner and pneumatic linear actuator Fig. 2 Positioner and pneumatic rotary actuator G -32 Position transmitter +31 A1-42 Limit switch +41 A2-52 Limit switch +51 A3-84 Fault alarm contact +83-12 4 20 ma signal +11-82 Solenoid valve +81 Fig. 3 Options of the positioner in ESD version Associated Information Sheet T 8350 EN Edition October 2007 Data Sheet T 8388-1 EN

Diagnostic tests without additional sensors Automatic test function start Display of classified status and fault alarms Condensed status or ESD alarms also displayed on the LCD of the positioner and issued to the fault alarm contact Operating hours counter allows data and test results to be sorted by time Display of minimum and maximum temperature with details on how long the limits have been exceeded Cyclical polling of test data, multiplexer-capable Data logger to plot the valve position against time; which can be triggered by the valve position condition and/or the integrated solenoid valve Hysteresis test to detect any friction changes Scope of application General In standard cases of application, a shut-off valve in a SIS loop is fitted with a solenoid valve for emergency shutdown and limit switches for position feedback. Dedicated shut-off valves typically remain static for months or years in normal operating conditions. The use of the Type 3730-3 Positioner in ESD version can prevent problems from occurring in this case. The following combination of components allows safety and test functions to be merged in one housing (Fig. 3): Position feedback Certified solenoid valve with a PFD rating (probability of failure on demand) to comply with SIL 3 Venting of the actuator by the pneumatics in the positioner with certified PFD Redundant venting of the positioner pneumatics by the integrated solenoid valve Limit switches Fault alarm output The positioner can be mounted on a valve to replace or supplement a solenoid valve. It enables the valve to be moved specifically to a set point within the valve working range. The partial stroke test function completely integrated into the positioner prevents the valve from becoming stuck, for example, due to corrosion or material disintegration. Maintenance intervals can be scheduled in a more flexible manner and even lengthened in certain cases. The necessary test validation can be performed simply by using the corresponding combination of instruments and the connection to a customary safety-related PLC (Fig. 4). The following integrated functions and features are also included in the positioner: Data logger to plot the w, x, e and y variables, which can be triggered by the valve position condition and/or the integrated solenoid valve, for example, on emergency shutdown Analysis and documenting of the last three partial stroke tests Status alarms over the fault alarm output Hysteresis test and extensive diagnostic functions Direct attachment, attachment according to IEC 60534 (NAMUR) and attachment to rotary actuators (VDI/VDE 3845) Integration Various combinations to integrate the positioner into the automation environment are possible. PT 1A IN OUT 4 20 ma 24 Volt 4 20 ma Tank Safety PLC 82 81 42 41 Process control system P 12 11 OUT HART Fig. 5 Positioner replaces the conventional solenoid valve Fig. 4 Positioner and safety-related PLC The positioner in ESD version replaces the conventional solenoid valve in Fig. 5. The safety-related PLC controls the safety function with both the solenoid valve and a limit switch connected to it correspondingly. The integration into the process control system and the asset management system also allows extensive diagnostic information and the set point input to be read. Fig. 6 shows that the solenoid valve is not required anymore since the positioner in ESD version is certified for reliable shutdown similar to a solenoid valve. An interruption in power supply leads to safe venting of the pneumatic output. 2 T 8388-1 EN

The 4-20 ma signal of the positioner is fed forward to the safety PLC in this combination. HART protocol is used in this case to integrate the positioner into the asset management system of a process control system. PT 1A IN OUT HART 4 20 ma 4 20 ma Tank Safety PLC 42 41 Process control system P 12 11 HART Scope of functions ESD mode In ESD mode, the shut-off valve is moved to a set point within the working range of the ESD valve. In the basic setting, the positioner behaves similar to a solenoid valve which keeps the connected valve open. Furthermore, the partial stroke test is triggered for test purposes manually (ESD-MAN) or automatically (ESD-AUTO) according to a time schedule. Partial stroke test (Fig. 7) The test is used to confirm that a normally open shut-off valve or a valve in its end position is still able to move and to prevent the valve from seizing up, for example, due to corrosion or material disintegration. The partial stroke test plotting also allows the dynamic control behavior to be analyzed. During the test, the valve is moved out of the end position or from a start value in steps or in a ramp function until it reaches a defined final value and then back again in the end position. The step response is performed, for example, between 10 and 15 % of rated travel starting from the end position while the plant is running, yet without disrupting plant operation. The following test cancellation conditions provide additional protection against the valve slamming shut and moving past the final value: Valve position x Drive signal y Maximum test time is exceeded Tolerance range exceeded. Fig 6 Positioner in ESD version for emergency shutdown Fig. 7 Partial stroke test 3 T 8388-1 EN

The course of the controlled variable x, reference variable w, system deviation e and drive signal y are stored in the positioner assigned to details from the operating hour counter. The dead time, T63, T98, overshooting as well as the rise and response times are analyzed separately for the rising and falling characteristic (Fig. 8). The analysis of the last three partial stroke tests are stored in the positioner with a time stamp. Plain test information (Fig. 8) A test status is assigned to a performed partial stroke test. As a result, it is possible to recognize whether a partial stroke test was successfully completed or not. In the case that the test was not successfully completed, the possible source of error is specified, too. In addition to an alarm displayed on the display of the positioner on site or issued to the engineering tool used, the ESD status can also be issued to the fault alarm output. The states of the last three performed tests are stored in the positioner with a time stamp. EXPERT/EXPERT + diagnostics The diagnostic functions of EXPERT and EXPERT + are integrated into the positioner. Refer to the Data Sheet T 8388 EN for a summary of the test functions. The EXPERT + test functions of the data logger and the hysteresis test to detect friction changes are also included in the ESD mode. The data logger stores the last x, w, e and y values in an FIFO memory. It can be automatically started by the stroke and/or solenoid valve functioning as the trigger event (see Fig. 9). The ESD version uses the valve position as the valve travel condition. Viewing and parameterization of the integrated ESD and diagnostic functions The TROVIS-VIEW or DTM software allow data, test results and alarms collected in the positioner to be conveniently parameterized and displayed in graphs. Furthermore, the data in the device description (DD) files are also accessible to other engineering tools to allow integration in process control systems and asset management systems from different manufacturers. How the data are viewed depends on the operator interface. In addition, the ESD functions can also be parameterized completely on site at the positioner. Alarms are also displayed on the LC display and issued over the fault alarm output. Graphs The variables collected from the ESD and diagnostics functions are displayed by the Trend Viewer as graphs in the TROVIS-VIEW and DTM software (Fig. 9). Fig. 8 Test information 4 T 8388-1 EN

Fig. 9 Data logger triggered by solenoid valve condition; a drop in solenoid valve voltage causes the valve to move to its fail-safe position Specifications subject to change without notice. 5 T 8388-1 EN

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main Germany Phone: + 49 69 4009-0 Fax: +49 69 4009-1507 Internet: http://www.samson.de T 8388-1 EN 2007-10