HAZARDOUS LOCATION CLASSIFICATIONS

Similar documents
5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Fire Alarm System Accessories

Classification of Hazardous Atmospheres

Electrical Classification

Class/Division Hazardous Location

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

Electric motors can pose a serious threat when they are

Basics of Explosion Protection

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections

Article Scope Articles 500 Through Definitions. VI. Selected Articles from the National Electrical Code 2011

HAZARDOUS AREA TECHNICAL GUIDE

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Design Safety Standards for Electrical Systems: Hazardous (classified) Locations -- OSHA Standard

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Assessing the Potential for a Dust Explosion and Navigating the Current Regulatory Environment

Outline. Background. NFPA 820 Applicability to Wastewater Treatment Facilities. Hazardous Area Classifications. Treatment Plant Area Classifications

Article Scope Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest

Spray Booth Guideline

Presented by: Rich Perry Marsh Risk Consulting

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Zone Hazardous Location

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

NEMA Enclosure Types

Explosion Prevention

Other OSHA Issues Not Easily Understood

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

12.85 Enforcement and Consultation Guidance for Combustible Dust Hazards December 30, 2008

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Today's world of increasing

Intrinsically Safe Barrier Relays NY2 and 8501TO

During Various Aluminum Fabricating Operations

ATEX Fans 08/02/2008. Data subject to change without prior notice

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

Combustible Dust: - The Basics You Need to Know. Presented by: Mary Ann Heaney, CIH, CSP ohsm, llc.

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

COMBUSTIBLE DUST EXPLOSIONS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

COMBUSTIBLE DUST in the WOOD PRODUCTS INDUSTRY

Combustible Dust. Overview

Is This Combustible Dust?

Explosion Protected Electrical Apparatus in the Russian Federation

Combustible Dust Booklet

AIHA Professional Development Conference by Daniel Brechko, Managing Consultant

Controlling fire and explosion risks in the workplace

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

Professional Series ATEX Portable Radios

Certain specific properties of compressed gases make them highly useful in various research activities.

WEEKLY SAFETY MEETING All Euramax Subsidiaries COMBUSTIBLE DUST. Safety Meeting Contents. Meeting Notice. Leaders Guide.

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

SAFETY AND HEALTH PROGRAM

Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A.

The Status of Combustible Dust Regulation

Failure Analysis Associates. Cell Phone Usage At Gasoline Stations

OSHA Office of Training and Education 1

Natural Gas Emergencies

General Confined Space Awareness

How To Protect An Explosion

exit routes and fire protection

Hazardous Substance Class Definitions & Labels

Ethanol Vehicle and Infrastructure Codes and Standards Citations

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Combustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS

SafeSite LED High Bay - UL 844 for Indoor and Outdoor Hazardous Applications

Combustible dust. How to use this guide. Combustible Dust

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

of Protecting Professionals through Innovative Lighting

Safe Operating Procedure

Minimum Ignition Temperature of Hybrid Mixtures Of Burnable Dusts and Gases

BUILDING A WORLD OF DIFFERENCE. Safe work in confined spaces

Group A/B Dust Explosion Classification Chilworth Hazard and Risk Profile (CHARP) - Standard package of tests

Flammable Liquids 29 CFR

Flammable and Combustible Liquids. Slide 1 (of 23)

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS

METHOD EXPLOSIVE ATMOSPHERE

Hazmat Materials Training Fact Sheet Module 2 Classification. The classification of hazardous materials is based on three key factors:

SURVIVE INSIDE: Employee Safety in Confined Spaces

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Commercial Garages, Repair, and Storage

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

FDNY C14 Certificate of Fitness Quiz

Safety Data Sheet for Whole Grain

EzFlex Combustible Gas Leak Detector Model EZ40

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010

FIRE PREVENTION PLAN

EXPLOSION SAFETY DOCUMENT FOR THE ATEX 137 DIRECTIVE NEW NAME FOR A FIRE AND EXPLOSION HAZARD ASSESSMENT?

List of Frequently Utilized Storage Tank Standards and Practices

Compressed Gas Cylinder Safety

Compressed Gas Cylinder Storage and Handling Guide

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA USA , Fax

FIRE EXTINGUISHER TRAINING

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Hazard Warning Signage Guidelines

Transcription:

HAZARDOUS LOCATION CLASSIFICATIONS

CLASS I: FLAMMABLE GASES, VAPORS OR LIQUIDS Area Classification Comparison Division 1 flammable gases, vapors or liquids can exist all of the time or some of the time under normal operating conditions. Zone 0 flammable gases, vapors or liquids are present continuously or for long periods of time under normal operating conditions. Zone 1 flammable gases, vapors or liquids are likely to exist under normal operating conditions. Division 2 Where ignitable concentrations of flammable gases, vapors or liquids are not likely to exist under normal operating conditions. Zone 2 Where ignitable concentrations of flammable gases, vapors or liquids are not likely to occur under normal operating conditions and if they do occur, will exist only for a short periods of time. Class I, Division 1 A Class I, Division 1 location is a location: In which ignitable concentrations of flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors can exist under normal operating conditions, or In which ignitable concentrations of such flammable gases, flammable liquid produced vapors, or combustible liquids above their flash points may exist frequently because of repair or maintenance operations or because of leakage, or In which breakdown or faulty operation of equipment or processes might release ignitable concentrations of flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors and might also cause simultaneous failure of electrical equipment in such a way as to directly cause the electrical equipment to become a source of ignition.

Class I, Division 2 A Class I, Division 2 location is a location: In which volatile flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors are handled, processed, or used, but in which the liquids, vapors, or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems or in case of abnormal operation of equipment, or In which ignitable concentrations of flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors are normally prevented by positive mechanical ventilation and which might become hazardous through failure or abnormal operation of the ventilating equipment, or That is adjacent to a Class I, Division 1 location, and to which ignitable concentrations of flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors above their flash points might occasionally be communicated unless such communication is prevented by adequate positive -pressure ventilation from a source of clean air and effective A Class I, Zone 0 A Class I, Zone 0 location is a location in which: Ignitable concentrations of flammable gases or vapors are present continuously, or Ignitable concentrations of flammable gases or vapors are present for long periods of time. Class I, Zone 1 A Class I, Zone 1 location is a location: In which ignitable concentrations of flammable gases or vapors are likely to exist under normal operating conditions; or In which ignitable concentrations of flammable gases or vapors may exist frequently because of repair or maintenance operations or because of leakage; or In which equipment is operated or processes are carried on, of such a nature that equipment breakdown or faulty operations could result in the release of ignitable concentrations of flammable gases or vapors and also cause simultaneous failure of electrical equipment in a mode to cause the electrical equipment to become a source of ignition; or That is adjacent to a Class I, Zone 0 location from which ignitable concentrations of vapors could be communicated, unless communication is prevented by adequate positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided.

Class I, Zone 2 A Class I, Zone 2 location is a location: In which ignitable concentrations of flammable gases or vapors are not likely to occur in normal operation and, if they do occur, will exist only for a short period; or In which volatile flammable liquids, flammable gases, or flammable vapors are handled, processed, or used but in which the liquids, gases, or vapors normally are confined within closed containers of closed systems from which they can escape, only as a result of accidental rupture or breakdown of the containers or system, or as a result of the abnormal operation of the equipment with which the liquids or gases are handled, processed, or used; or In which ignitable concentrations of flammable gases or vapors normally are prevented by positive mechanical ventilation but which may become hazardous as a result of failure or abnormal operation of the ventilation equipment; or That is adjacent to a Class I, Zone 1 location, from which ignitable concentrations of flammable gases or vapors could be communicated, unless such communication is prevented by adequate positive - pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. Gas Group Comparison A (Acetylene) B (Hydrogen) C (Ethylene) D (Propane) IIC (Acetylene & Hydrogen) IIB (Ethylene) IIA (Propane) Division 1 & 2 Gas Groups Group A: Acetylene Group B: Flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value less than or equal to 0.45 mm or a minimum igniting current ratio (MIC ratio) less than or equal to 0.40 Group C: Flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value greater than 0.45 mm and less than or equal to 0.75 mm, or a minimum igniting current ratio (MIC ratio) greater than 0.40 and less than or equal to 0.80

Group D: Flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value greater than 0.75 mm or a minimum igniting current ratio (MIC ratio) greater than 0.80 Zone 0, 1 & 2 Gas Groups Group IIC: Atmospheres containing acetylene, hydrogen, or flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value less than or equal to 0.50 mm or minimum igniting current ratio (MIC ratio) less than or equal to 0.45 Group IIB: Atmospheres containing acetaldehyde, ethylene, or flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either maximum experimental safe gap (MESG) values greater than 0.50 mm and less than or equal to 0.90 mm or minimum igniting current ratio (MIC ratio) greater than 0.45 and less than or equal to 0.80 Group IIA: Atmospheres containing acetone, ammonia, ethyl alcohol, gasoline, methane, propane, or flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value greater than 0.90 mm or minimum igniting current ratio (MIC ratio) greater than 0.80 MESG (Maximum Experimental Safe Gap): The maximum clearance between two parallel metal surfaces that has been found, under specified test conditions, to prevent an explosion in a test chamber from being propagated to a secondary chamber containing the same gas or vapor at the same concentration. MIC (Minimum Igniting Current) Ratio: The ratio of the minimum current required from an inductive spark discharge to ignite the most easily ignitable mixture of a gas or vapor, divided by the minimum current required from an inductive spark discharge to ignite methane under the same test conditions. Temperature Class Comparison, F Division 1 and 2 Zone 0, 1 and 2 T1 ( 842 F) T2 ( 572 F) T1 ( 842 F) T2 ( 572 F) T2A, T2B, T2C, T2D ( 536 F, 500 F, 446 F, 419 F) --- T3 ( 392 F) T3 ( 392 F) T3A, T3B, T3C ( 356 F, 329 F, 320 F) --- T4 ( 275 F) T4 ( 275 F) T4A ( 248 F) --- T5 ( 212 F) T6 ( 185 F) T5 ( 212 F) T6 ( 185 F)

CLASS II: COMBUSTIBLE DUSTS Area Classification Comparison Division 1 combustible dust can exist all of the time or some of the time under normal operating conditions. Zone 20 combustible dust or ignitable fibers/flyings are present continuously or for long periods of time under normal operating conditions. Zone 21 combustible dust or ignitable fibers/flyings are likely to exist under normal operating conditions. Division 2 combustible dust are not likely to exist under normal operating conditions. Zone 22 combustible dust or ignitable fibers/flyings are not likely to exist under normal operating conditions. Class II, Division 1 A Class II, Division 1 location is a location: In which combustible dust is in the air under normal operating conditions in quantities sufficient to produce explosive or ignitable mixtures, or Where mechanical failure or abnormal operation of machinery or equipment might cause such explosive or ignitable mixtures to be produced, and might also provide a source of ignition through simultaneous failure of electrical equipment, through operation of protection devices, or from other causes, or In which Group E combustible dusts may be present in quantities sufficient to be hazardous. Class II, Division 2 A Class II, Division 2 location is a location: In which combustible dust due to abnormal operations may be present in the air in quantities sufficient to produce explosive or ignitable mixtures; or Where combustible dust accumulations are present but are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus, but could as a result of

infrequent malfunctioning of handling or processing equipment become suspended in the air; or In which combustible dust accumulations on, in, or in the vicinity of the electrical equipment could be sufficient to interfere with the safe dissipation of heat from electrical equipment, or could be ignitable by abnormal operation or failure of electrical equipment. Zone 20 A Zone 20 location is a location in which: Ignitable concentrations of combustible dust or ignitable fibers/flyings are present continuously. Ignitable concentrations of combustible dust or ignitable fibers/flyings are present for long periods of time. Zone 21 A Zone 21 location is a location: In which ignitable concentrations of combustible dust or ignitable fibers/flyings are likely to exist occasionally under normal operating conditions; or In which ignitable concentrations of combustible dust or ignitable fibers/flyings may exist frequently because of repair or maintenance operations or because of leakage; or In which equipment is operated or processes are carried on, of such a nature that equipment breakdown or faulty operations could result in the release of ignitable concentrations of combustible dust or ignitable fibers/flyings and also cause simultaneous failure of electrical equipment in a mode to cause the electrical equipment to become a source of ignition; or That is adjacent to a Zone 20 location from which ignitable concentrations of dust or ignitable fibers/flyings could be communicated, unless communication is prevented by adequate positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. Zone 22 A Zone 22 location is a location: In which ignitable concentrations of combustible dust or ignitable fibers/flyings are not likely to occur in normal operation and, if they do occur, will only persist for a short period; or In which combustible dust or fibers/flyings are handled, processed, or used but in which the dust or fibers/flyings are normally confined within closed containers of closed systems from which they can escape only as a result of the abnormal operation of the equipment with which the dust or fibers/flyings are handled, processed, or used; or That is adjacent to a Zone 21 location, from which ignitable concentrations of dust or fibers/flyings could be communicated, unless such communication is prevented by adequate positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided.

Dust Group Comparison Class II, Division 1 and 2 Zone 20, 21 and 22 E (Metals Division 1 only) F (Coal) None G (Grain) Division 1 & 2 Dust Groups Group E: Atmospheres containing combustible metal dusts, including aluminum, magnesium, and their commercial alloys, or other combustible dusts whose particle size, abrasiveness, and conductivity present similar hazards in the use of electrical equipment. Group F: Atmospheres containing combustible carbonaceous dusts that have more than 8 percent total entrapped volatiles (see ASTM D 3175-02, Standard Test Method for Volatile Matter in the Analysis Sample for Coal and Coke, for coal and coke dusts) or that have been sensitized by other materials so that they present an explosion hazard. Coal, carbon black, charcoal, and coke dusts are examples of carbonaceous dusts. Group G: Atmospheres containing combustible dusts not included in Group E or F, including flour, grain, wood, plastic, and chemicals. Zone 20, 21 & 22 Dust Groups: None Temperature Class Comparison, F Division 1 and 2 Zone 20, 21 and 22 T1 ( 842 F) T2 ( 572 F) T2A, T2B, T2C, T2D ( 536 F, 500 F, 446 F, 419 F) T3 ( 392 F) T3A, T3B, T3C ( 356 F, 329 F, 320 F) None Note: For Zone 20, 21 and 22, equipment shall be marked to show the operating temperature. T4 ( 275 F) T4A ( 248 F) T5 ( 212 F) T6 ( 185 F)

CLASS III: IGNITABLE FIBERS & FLYINGS Area Classifications Division 1 Where easily ignitable fibers/flyings are handled, manufactured, or used. Division 2 Where easily ignitable fibers/flyings are stored or handled other than in the process of manufacture. Class III, Division 1 A Class III, Division 1 location is a location in which easily ignitable fibers/flyings are handled, manufactured, or used. Class III, Division 2 A Class III, Division 2 location is a location in which easily ignitable fibers/flyings are stored or handled other than in the process of manufacture. Ignitable Fibers & Flyings Groups Class III, Division 1 and 2 None Division 1 & 2 Fibers & Flyings Groups: None Temperature Class, F Division 1 and 2 None Note: Article 503 of the NEC limits the maximum temperature for Class III equipment to 329 F (equivalent to a T-Code of T3B) for equipment not subject to overloading and to 248 F (equivalent to a T-Code of T4A) for equipment that maybe overloaded (such as motors or power transformers).