User s Guide DCB83. Liquid Density and Concentration Tester. Shop online at omega.com

Similar documents
OME-SERIES DATA ACQUISITION CARDS

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

MFT Series INTRODUCTION UNPACKING FERRULES

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM

FTH SERIES HEATERS INSTALLATION, OPERATION AND MAINTENANCE

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. info@omega.com

User s Guide HHM-GRT Wire Earth Resistance Tester. Shop online at omega.com info@omega.com For latest product manuals: omegamanual.


User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com info@omega.com For latest product manuals: omegamanual.

User s Guide. SW DIN Series and OSW Series. Shop online at. Rotary Selector Switches

User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors

Shop online at: omega.com For latest product manuals: omegamanual.info

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ExStik TM ph Waterproof Meters

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Bottom Loading Water Dispenser

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Triton Systems of Delaware, LLC. Warranty Statement

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Mold Alert... Operation Manual P0270

Intelli-Time Alarm Clock model 13027

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer with Color Alert

User Manual (English)

IR Repeater. Operation Manual P8620

User s Guide WRS232-USB. Universal Wireless RS232 to USB Transceiver, WRS232 Wireless Transmitter, WUSB Wireless Receiver.

Gibson Dark Fire System Quick Start

Sip/Puff Switch User Guide

Limited Warranty Letter for BYD Photovoltaic Module

Commercial Cardiovascular Equipment

NortechCommander Software Operating Manual MAN R6

Triton Systems of Delaware, LLC Warranty Statement / Return Policy

User Manual. Humidity-Temperature Chart Recorder. Model RH520

POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS

Soil Sensor Reader PRODUCT MANUAL

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

User s Guide OM-MICROLITE-8 AND OM-MICROLITE-16 DATA LOGGERS AND OM-MICROLAB-LITE SOFTWARE. Shop online at

INSTALLATION AND OPERATING INSTRUCTIONS

Alarm Clock USER GUIDE

Support. Phone Number. Technical. Security. On-Site Repair. Peace of Mind. EPSON PreferredSM. Priority. Toll-Free. and

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Single Port T1/E1 Tap

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

Sun Vinyl New Construction Windows Homeowner's Warranty

15 Digital Photo Frame Instructional Manual


DREAMLINE EXCLUSIVE LIMITED WARRANTY

User s Guide OM-USB-TC. 8 Channel Thermocouple Input USB Data Acquisition Module. Shop online at

24.2L M.A.N. V12 Engine Module

Dual Laser InfraRed (IR) Thermometer

The Analytical Balance

DVI to Analog Converter

Microwave Meter. Instruction Manual

Wolverine Data PASS Portable Scanner User Manual V1.0

LCD5500Z / PKP-LCD v3.x Installation Instructions

TRANSLATOR INSTALLATION AND OPERATIONS MANUAL KEYBOARD AND MOUSE CONVERTER Stancliff Road Phone: (281)

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage S... Digitalvåg U.S.A. and countries outside the EU...

Laptop Power Adapter for home/office User Manual

ELORA 240 BATTERY. Owner s Manual Revision A

American Dish Service

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

High Temperature InfraRed Thermometer with Laser Pointer

SAVARD PLUMBING COMPANY

TERMS AND CONDITIONS

Wireless Indoor/ Outdoor Thermometer

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

SELLING TERMS AND CONDITIONS

INSTRUCTION MANUAL DTH Fax: (503)

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

3 WATT LED SPOTLIGHT Model No. SLM

Installation and Operation Guide for PD4100 Series Power Control Centers

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Automatic Phone-Out Home Monitoring Systems

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Industrial Semi Metal USB

User and Installation Guide

We reserve the right to make technical changes.

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Advantium 2 Plus Alarm

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

MTX-D, Oil Temperature/Pressure Gauge

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

Owner s Manual & Safety Instructions

Transcription:

User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info MADE IN TAIWAN DCB83 Liquid Density and Concentration Tester

www.omega.com info@omega.com Servicing North America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 Stamford, CT 06907-0047 USA Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.

Electronic Densimeter (Liquid Density & Concentration Tester) DCB83 Instruction Manual Before using this instrument, please read the instructions carefully. Please keep manual in a ready reference.

A. Density calculation: According to the buoyancy method of Archimedean principle, the unknown liquid density can be calculated by using the standard glass weight. The weight species can be chosen according to the liquid property. B. Concentration calculation: According to the transformation formula of density and concentration (y= a + bx), y is concentration, x is density, and it can be calculated by using back-stepping linear. 1. Accessories: 1. Liquid specialized frame 2. Glass weight 3. Hook 4. 50 cc beaker 5. Support plate 6. Main-body 7. Windshield (optional) 8. AC adaptor 9. Thermometer 10. Calibration weight 2. The installation of DCB83 When installing DCB83, it should avoid: The vibration place Static electricity Æ Direct sunshine Ø Electromagnetic wave The places where is too wet or too high temperature 1

Installation Steps: After placing the DCB83 body in the windshield, adjust the 4 feet of main-body, adjust the level bubble on the after side of the main-body to the center. Put the liquid specialized frame on the weighing scale, and using the four feet getting stuck the frame. Æ Embedding the 4 round feet of the black support plate into the 4 round hole of the main-body. Ø Place the two pieces removable doors of the windshield on the top and the front, then the installation finishes. 3. Warming up: It takes about 10 minutes for an electric circuit to become stable after plugged in and turn on the power. 4. Calibration: When using the direct reading electronic densimeter DCB83, the density of the sample is on the basis of the weight calculation. Accurate measurement result is based on measuring the gravity accurately. It is recommended to calibrate with 100g weight on the following occasions. when the balance is first used when the balance has been moved when the location of surroundings are changed as a periodical adjustment 4.1. How to calibrate: Plug in and preheat for 30 minutes (for cold northern regions) Display show When the balance is under the state of weighing mode, press the key ZERO and hold it. It means entering calibration procedure when it displays CAL, It will display mutual flashing between CAL and 300 A: Put the 100g calibration weight on the sensor when the screen flickers, the balance will detect weight automatically and calibrate it simultaneously. B: The calibration finishes when the screen displays END- 0.00 CAL 300 CAL 100 100.00 C Pick up the weight and back to the under-test mode 0.000 Notice: After calibration, it should be calibrated again if the machine is moved to other places. 2

5. Setting the weight of glass weight, the high limit and low limit of density When the screen displays 0.00, press the key F and hold it to enter parameter setting, click the key F to enter the next parameter setting, the parameter setting procedure is A2 d SG Hi SG Lo E1 E2, press PRINT to enter the mode to modify the parameter, the methods of data-modifying are as follows: 1. Increase the value 2. Press PRINT and hold it to give up modifying 1. Digital shift 2. Press Fand hold it to go off the options 1. Confirm changes 5.1 Setting the weight of glass weight A2: weighing the glass weight first, and then input the weight of glass weight to A2 Method1: Under the 0.00g measuring state of liquid mode, put the hook on the liquid specific frame, press ZERO to re-zero; then catch on the glass weight by using the hook, press MOMOERY key after stable, the screen will display SET A2, it indicates that the glass weight has been memorized to A2. Method2 Press the key F and hold it when the screen shows 0.00, when it shows A2, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set the weight of glass weight; after setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. 3

5.2 Setting the density of glass weight: After setting the weight of glass weight, when it shows d, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set the density of glass weight; If the density of glass weight is 2.226, input d 2.226, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. 5.3 The function of high limit and low limit setting: (Setting of SG Hi, SG Lo) DCB83 has the function of high limit and low limit, the range of high limit and low limit can be set freely. If the density of the sample is higher than the high limit, the screen will display Hi; if lower than the low limit, it will show Lo; If the density is between the high limit and low limit, the screen will show OK. Notice: When the setting of high limit and low limit is 00.000, the function is closed. 5.3.1 The density setting of high limit: SG Hi The steps are as follows: Enter setting mode, press F for several times until the screen displays the density setting of high limit SG Hi, press PRINT to enter the option; then press PRINT again to modify the value, and press F to shift; At the moment press PRINT and F to set the value needed, press the key MEMORY to back to the next setting mode after finishing setting, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. 5.3.2 The density setting of low limit: SG Lo The steps are as follows: Enter setting mode, press F for several times until the screen displays the density setting of low limit SG Lo, press PRINT to enter the option, then press PRINT again to modify the value, and press F to shift; At the moment using PRINT and F setting the value needed, press the key MEMORY to memorize and back to the next setting mode after finishing the setting, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. 4

5.4 Setting E1, E2 for testing concentration According to the transformation formula of density and concentration (y= a + bx), y is concentration, x is density, and it can be calculated by using back-stepping linear. For example as follows: Conc.(%) Den.(g/cm 3 ) at 20 C Conc.(%) Den.(g/cm 3 ) at 20 C 10.0 0.9820 10.6 0.9842 10.1 0.9824 10.7 0.9845 10.2 0.9827 10.8 0.9849 10.3 0.9831 10.9 0.9852 10.4 0.9835 11.0 0.9855 10.5 0.9838 According to the data as above and according to the transformation formula y = a + bx, and by using the back-stepping linear of commercial software, we can get the formula y = 283.21 x 268.12. Thus, the parameter of E1 (-268.12) and E2 (283.21) can be set. 5.4.1 E1 Setting: Entering setting procedure, press F for several times until the screen shows E1, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set E1, after finishing setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. 5.4.2 E2 Setting: Entering setting procedure, press F for several times until the screen shows E2, press the key PRINT to enter the option, press the key PRINT again to change the value, press F to shift; At the moment, using PRINT and F to set E2, after finishing setting, press the key MEMORY to memorize and back to the next setting mode, press PRINT and hold it to give up the option if on need to modify; press the key F and hold it back to the test state. Note: If E1 or E2 is negative value, please note to input a minus sign (-) before the value. Notes: The machine should be kept clean, it needs to be cleaned if the liquid spills out. Please be careful when measuring the explosive or high volatile liquid, because the liquid will be harmful to human body and the machine. 5

6. The operation steps: Pour the 50ml liquid sample into the beaker Put the standard glass weight whose weight has been memorized into the liquid Æ Put the beaker on the center of the support plate. Ø Hang the hook on the center of the liquid specific frame Press RE-ZERO to deduct the weight of the hook ± Use the hook catching on the standard glass weight, it will display the weight of glass weight in measuring liquid Make sure the measuring liquid is higher than glass weight, and the glass weight can not touch the beaker. After stable, press MEMORY, it will calculate the liquid density value. The screen will display the liquid density value If E1, E2 has been set, concentration will be showed by pressing F If another sample needs to be measured, press MEMORY to back to the under test state 0.00g. µ If need to measuring again, please note as follows: After cleaning the hook and the glass weight, use another measuring liquid. 6

7. Operating Notes Electronic densimeter belongs to precise electronic balance, please assign specific person to be responsible for management and operating. If water and other liquid spill out from the container carelessly during measuring, notify the director timely, or it will delay the repair time. Æ Make sure if the machine is at the condition of being immersed or having any fault, before going off duty everyday, it should be checked by director to make sure the screen can show 0.00g, if displays 88888, it means the machine has broken down. Ø How to do if the body is flooded? Cut off the power first and turn over the body, dry it. Notify the professional maintenance staff of sellers to check and maintain it. Do not dismantle it by yourself, or it will damage load cells. 8. Maintenance DCB83 can not measure objects over 300g, and it should avoid loading the sample over 300g during the process of installation or operating. The surface of the machine must be cleaned by dry cloth, please avoid the accumulation of dust. Æ Remove the sink if the machine is non-use for a long time. Ø The machine should avoid crash squeeze and damp, if non-use for a long time, remove the power supply and cover it with dust cover. 7

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com sm TEMPERATURE MU Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies MU Wire: Thermocouple, RTD & Thermistor MU Calibrators & Ice Point References MU Recorders, Controllers & Process Monitors MU Infrared Pyrometers PRESSURE, STRAIN AND FORCE MU Transducers & Strain Gages MU Load Cells & Pressure Gages MU Displacement Transducers MU Instrumentation & Accessories FLOW/LEVEL MU Rotameters, Gas Mass Flowmeters & Flow Computers MU Air Velocity Indicators MU Turbine/Paddlewheel Systems MU Totalizers & Batch Controllers ph/conductivity MU ph Electrodes, Testers & Accessories MU Benchtop/Laboratory Meters MU Controllers, Calibrators, Simulators & Pumps MU Industrial ph & Conductivity Equipment DATA ACQUISITION MU Data Acquisition & Engineering Software MU Communications-Based Acquisition Systems MU Plug-in Cards for Apple, IBM & Compatibles MU Data Logging Systems MU Recorders, Printers & Plotters HEATERS MU Heating Cable MU Cartridge & Strip Heaters MU Immersion & Band Heaters MU Flexible Heaters MU Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL MU Metering & Control Instrumentation MU Refractometers MU Pumps & Tubing MU Air, Soil & Water Monitors MU Industrial Water & Wastewater Treatment MU ph, Conductivity & Dissolved Oxygen Instruments M5366/1213