CC MPPT User s Manual

Similar documents
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

PSC-A5 Solar Charge Controller Manual

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

Solar Controller / Battery Charger User s Manual

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

LITHIUM BALANCE CHARGER

SOLAR POWER - THE NEW WAY TO RV!

INSTALLATION AND OPERATION MANUAL

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Installation and Operation Back-UPS 1250, 1300, 1500

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

SOLAR ChARge CONTROLLeRS

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

12 Volt 30 Amp Digital Solar Charge Controller

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

SNMP Web Management. User s Manual For SNMP Web Card/Box

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Charge Regulator SCR 12 Marine

DAB+ / FM Tuner Model: TU-201

Hand-held thermometer Model CTH7000

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

View Star series. Solar Charge Controller INSTRUCTION MANUAL

Snap-It. This is an accessory (switch machine) decoder

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

OCSM Series. High Resolution Digital Crane Scale. User Guide

Advanced LED Controller (LED Chaser)

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

TruPower-Portable-500W. Solar Starter kit

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

Odyssey of the Mind Technology Fair. Simple Electronics

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

MIDNITE SOLAR AND SOLAR WASHINGTON

Operating Instructions

Portable Air Conditioner

AUTODIALLER / QUICKDIALLER - SA132

Air conditioning, electrical testing

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

User s Manual AURORA 1.2K/2.2K

BB800 Off-Grid Solar System

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Light Meter (Foot Candles)

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

How To Control A Battery Cell Phone With A Battery Power Control System

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

User s Manual Before using the inverter, you need to read and save the safety instructions.

User Manual of Grid Tie Inverter with Limiter

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

Temperature Compensated Charging of Lead Acid Batteries

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06

Wind/solar hybrid controller instructions

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

GSM HOME SECURITY SYSTEM

Industrial Solar Power PoE Switch

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Troubleshooting Salt Generators

S10I / S20I / S30I Solar Light Controller USER MANNUAL

Automatic start of a generator

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

How To Use A Power Supply Unit (Upu)

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

NC-12 Modbus Application

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

NASS Solar DC Pool Pumps

INSTALLATION GUIDE. FCC ID NOTICE

I4.35. Link Owner's Manual. AL Xantrex OWNERS MANUAL. Link Inverter Controller and Dual Battery Monitor. Link Control.

ABB Drives. User s Manual HTL Encoder Interface FEN-31

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

INSTALLATION & SERVICE MANUAL. Display Panel

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Product Information Sheet UH28CS-12kV Hi Pot Tester

Solar Photovoltaic (PV) Systems

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

QUICK PROBLEM SOLVING GUIDE

Applied Electronics. Commercial Dimming System UPDATE NOTICE

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Important Safety Instructions

9452/9453 Installation and User Guide

Temperature & Humidity SMS Alert Controller

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

GSM Alarm System User Manual

2 Installation Explanation

Transcription:

CC MPPT User s Manual Introduction Congratulations! You are the proud owner of one of the best MPPT charge controllers available in India. Please read this manual carefully before installing and operating the charge controller. Systellar Innovations offer MPPT charge controllers in the following models: Product Models Nominal Battery Maximum Charging Maximum Solar Voltage Current Panel Voc 1. CC-MPPT-1224-20 12 / 24 volts 20 amps 70 volts 2. CC-MPPT-36-20 36 volts 20 amps 100 volts 3. CC-MPPT-48-20 48 volts 20 amps 100 volts 4. CC-MPPT-1224-40 12 / 24 volts 40 amps 70 volts 5. CC-MPPT-36-40 36 volts 40 amps 100 volts 6. CC-MPPT-48-40 48 volts 40 amps 100 volts 7. CC-MPPT-1224-20H 12 / 24 volts 20 amps 150 volts 8. CC-MPPT-36-20H 36 volts 20 amps 150 volts 9. CC-MPPT-48-20H 48 volts 20 amps 150 volts 10. CC-MPPT-1224-40H 12 / 24 volts 40 amps 150 volts 11. CC-MPPT-36-40H 36 volts 40 amps 150 volts 12. CC-MPPT-48-40H 48 volts 40 amps 150 volts These charge controllers can work with Solar Photo Voltaic Panels with wide power and voltage range. They track the maximum power point dynamically to extract maximum possible power from the solar panels. A three stage battery charging algorithm (Boost, Absorption and Trickle charge) is implemented which can charge battery with precise current and voltage to achieve fast battery charging yet ensuring long battery life. Increment button Menu/Next button LED to indicate battery charging status Decrement button LCD Display PV +ve Load -ve PV -ve Battery +ve Battery -ve Load +ve

Left Side View For connecting external Battery temperature sensor(optional accessory) For system calibration only. Do not connect anything here Right Side View Power Saver / Night Light Relay Connector (Optional Accessory)

Installing the Charge Controller 1. Install the Charge Controller indoors near the battery bank at eye level. This will make it easy to read the LCD display and make any changes in the settings. 2. Connect the battery using minimum 4 mm sq. cables for 20 amp models and 8 mm sq. for 40 amp models. It is better to use even thicker battery cable to reduce power loss in the cable. Keep cable length small to minimize losses. First connect battery cable and then the solar panel cable. Observe correct polarity while connecting wires from battery and Solar panels. If wires are connected in wrong polarity, the Batt. connection fault LED / SP connection fault LED will start glowing. Correct the polarity before proceeding further. 3. As soon as the battery cables are connected, the Charge Controller will start working and its display will start showing various messages. 4. Check open circuit voltage of the solar panels: For model CC-MPPT-1224-xx, maximum solar panel voltage should be less than 70 volts. This means that maximum three 12V solar panels (V oc 19 21V) can be connected in series. Any number of such series strings may be connected in parallel to increase the power of the solar panels. If 24V solar panels are used (V oc 36 43V), then these panels should not be connected in series. These panels should only be connected in parallel to each other. For model CC-MPPT-36-20 and CC-MPPT-48-20, maximum solar panel voltage should be less than 100 volts. This means that maximum four 12V solar panels (V oc 19 21V) can be connected in series. If 24V solar panels are used (V oc 36 43V), then two panels may be connected in series. Any number of such series strings may be connected in parallel to increase the power of the solar panels. *** Note 1: Connecting higher than rated solar panel voltage to the charge controller may damage it and will void warranty coverage. Max. Voc specified for a model should be 5 to10 volts less than the maximum specified solar panel voltage. *** Note 2: In case solar panel voltage nears the maximum solar panel voltage specified for the model (75 volts for MODEL_1224, 95 volts for MODEL_36 / MODEL_48 or 140V for H suffix models) the system will not start charging the battery. Instead message Fault, V_SP too high will be displayed on the LCD. Once solar panel voltage goes below 72 volts / 90 volts / 130 volts respectively, the system will be automatically reset to start normal operation. 5. Connect solar panel to the charge controller in correct polarity. If the solar panel voltage is above 60 volts, take care not to touch solar panel cable ends with bare hand. It may give electric shock. Once connections are made, if it is day time, the battery charging will start after about 30 seconds.

Setting programmable parameters To enter Adjust Parameter mode, keep the NEXT key pressed for 2 seconds. It will turn on the back light of the LCD and display the first parameter with its present value. To increase the value, press INCR key. To decrease the value, press DECR key. Note that the value of the parameter will not go beyond its preset limits. When NEXT is pressed, the displayed value of the parameter is written in the MEMORY and the display goes to the next parameter. Press NEXT key for 2 seconds to come out of Adjust parameter mode. If no key is pressed for 20 seconds, it automatically comes out of Adjust parameter mode. Note that in this case, the value of the last parameter is not written in MEMORY. LCD Display Messages* LCD line 1 LCD line 2 Initial display messages: Message 1: Company name. In case the system is uncalibrated, line 2 displays Sys Uncalib Systellar Innovations Message 2: Line 1 displays the CC Model and line 2 the software version CC-MPPT-1224-20 Sw ver. 3.00 DAY time messages when battery is being charged Message 1: Line 1 displays PV panel voltage and current. Line 2 displays PV power in Watts and the cumulative KWHr PV:029.5V 04.6A 136W 12.345KWHr Message 2: Line 1 displays Battery voltage and charging current. Line 2 displays the charging mode. In case Equalizing mode has been set, line 2 displays E in the last column. Batt:12.9V 10.2A Boost Chg Message 3: Line 1 displays the load current. In case the load is Off, it displays Load is Off. Line 2 displays relay status. If Relay is set to be used as Power Saver it displays PSaver is On/Off. In case Relay is set to be used as Night Light Switch, it displays Night Light:On/Off Load cur: 12.5A PSaver is On Message 4: Line 1 displays temperature. In case optional battery temperature sensor is installed, it displays battery temperature else it displays ambient temperature. Line 2 Temp: 33 deg C Day:0.230KWHr

displays Day and the energy collected form the solar panels today in KWHr units Night time messages Message 1: Line 1 displays Battery voltage. Line 2 displays Nite (Night) and the energy collected by the solar panels during the day which has just ended. Batt: 12.7V Nite: 1.526KWHr Message 2: Line 1 displays the load current. In case the load is Off, it displays Load is Off. Line 2 displays relay status. If Relay is set to be used as Power Saver it displays PSaver is Off. In case Relay is set to be used as Night Light Switch, it displays Night Light:On/Off Load cur: 12.5A Night Switch: On Adjust Parameters messages End of Charging Voltage: (Default: 14.2V, Range: 13.6 14.5V) End of Charging Voltage: 14.2V *Note: The voltage shown in the table are for 12V battery bank. For 24V, 36V and 48V battery banks, these voltages will be 2, 3 and 4 times respectively. Trickle Charging voltage: (Default: 13.6V, Range: 13.2V 14.0V) Equalizing Charge voltage: (Default:14.6V, Range: 14.0V 14.8V) Trickle Charging Voltage: 13.6V Equalizing Chg Voltage: 14.6V Max. Charging current: (In 20A models Default: 20A, Range: 5A 20A, step 2.5A) (In 40A models Default: 40A, Range: 5A 40A, step 2.5A) Max. Charging Current: 20A Absorption Time: Float Hold Time: Min. 5-150:030

Default: 30 minutes, Range 5 150 minutes. This is the time for which the battery voltage is held at its end of charge voltage while charging, before it is reduced to the trickle charge voltage. Recommended values for this parameter are: Flat plate battery: 60 minutes Tubular battery: 150 minutes SMF (Sealed Maintenance Free) Battery: 5 minutes Load Control code: Load Ctrl Code: A On:0, 1-14: Always On: 0, Dusk to dawn On: 1 2 14 Number of hours On after dusk Relay Usage: (0: Power Saver Normal, 1: Night Switch, 2: Power Saver Extended) Relay Usage: 0/2 Psvr,1 NSw:1 In case Relay usage is set as Power Saver Normal or Power Saver Extended, it displays: Power Saver Off Voltage: 11.5V Power Saver Off Voltage: (Default:11.5V, Range: 11.2 11.8V) In case Relay usage is set as Night Light Switch, it displays messages as shown here. Code 1 is for Dusk to Dawn operation of the night switch and 2 14 Number of hours On after dusk (Default: 4) Night Light Sw: 1D-D 2-14 Hrs:04 *Note: The voltage shown in the table above are for 12V battery bank. For 24V, 36V and 48V battery banks, these voltages will be 2, 3 and 4 times respectively.

Intelligent Absorption charge time adjustment: Absorption charge time can be set by the user from 5 to 150 minutes. Once the absorption time is over, the battery goes in Trickle charge mode and the battery terminal voltage is reduced to 13.6volts. During night, there will be no power from the solar panel and the battery may be partially discharged during the night. Next day when solar power is available, CC-MPPT will intelligently determine the Absorption Charge time based on the battery usage last night. The following logic is used to determine the absorption charge time. In case the battery voltage is below 12.4V for say N minutes, Absorption time will be set to N minutes (subject to the maximum value set in the parameter Absorption time ). If the battery voltage is below 12V for N minutes, the absorption time will be increased by 2 x N minutes. And if the battery voltage is below 11.6V for N minutes, the absorption time will be increased by 4 x N minutes. However, the maximum absorption time will be the Absorption time set by the user. Setting Equalizing charging mode: It is useful to overcharge the battery bank for a limited period of time once every month. This is especially helpful when several batteries are connected in series (like 24V, 36V or 48V battery bank). It helps in equalizing the charge in all the cells of the battery bank by bringing them to full charge. The electrolyte in the batteries is also homogenised by agitation during gassing at the time of overcharge. In Systellar MPPT charge controller, equalizing charge can be set by pressing the NEXT key twice in quick succession. To confirm that equalization charging mode has been set, check the day time display message 2. If equalizing mode is set, E is displayed in the last column. In case NEXT key is pressed twice in quick succession, when equalizing mode is already set, the equalization mode is reset. Note that when equalization mode is set, it does not go to equalization charging mode immediately. Equalization charging is the last leg of battery charging. In equalizing charging mode, instead of stopping the battery voltage at end of charge voltage, the system will allow the battery to go up to Equalizing Charge voltage and it will maintain it there for a total period of 60 minutes. Once this time period is over, the battery will go into Trickle charging mode and equalizing mode will be automatically reset. Relay Usage options: There are 3 settings for the usage of the external relay: 0: Power Saver Normal 1: Night Light Switch 2: Power Saver Extended In Power Saver Normal (0) and Power Saver Extended (2) modes, the external relay (Common - N/C) is connected at the inverter mains input. When Power Saver is On, mains supply to the inverter is cut off. In both these modes, power saver relay turns on at sunrise when solar panel voltage is more than 15V (or 27V / 40V and 52 volts respectively for 12V / 24V / 36V / 48V battery banks). The second condition for power saver relay turning on is that battery should be in trickle charge mode or battery voltage should be equal to or greater than 13.5V.

In Power Saver Normal mode, relay turns off approx. 2 hours before sunset or when battery has been discharged to Power Saver Off Voltage. In Power Saver Extended Mode, relay turns off only when battery has been discharged to Power Saver Off Voltage. i.e. the power saver will remain on even at night if battery voltage remains above Power Saver Off Voltage. This mode is useful for minimizing electricity bill if solar energy is normally sufficient to run the load during the day as well as night. Reading of energy collected in last 3 days: You can see the energy collected by CC-MPPT in last 3 days by pressing the INCR key for 2 seconds. The display will show the total energy in the first row and the energy collected in last 3 days in the second row (In KWHr units). Sleep mode: At night, if CC-MPPT is idle (i.e. no key is pressed for 5 minutes), the system will go in to SLEEP mode. In this mode, the LCD display will show Sleeping / Press NEXT. The system will wake up automatically the next morning or when NEXT key is pressed by the user. This is done to further reduce the idle current drawn by CC-MPPT from the battery. Optional Accessories 1. Battery Temperature sensor External Battery Temperature Sensor Battery temperature sensor is supplied as an accessory. Paste the temperature sensor on the battery side using double sided tape. Insert the 4 pin RJ11 connector at the end of the temperature sensor cable in the socket provided on the left side of the charge controller.

2. Power Saver / Night Light Switch Relay box: For use as power saver: Power Saver/Night Light Switch Relay Box Power Saver Connection Diagram Program the parameter Relay usage to 0 (Power Saver Normal) or 2 (Power Saver Extended). Set appropriate Power Saver Off voltage. If you want to use maximum solar energy set this voltage nearer to 11.2V. However if you want to minimize the possibility of battery getting discharged (in case of grid supply failure) then set it nearer to 11.8V Inside the relay box the tag going to the output socket should come from the N/C contact of the relay. This will cause the mains supply to the inverter to be cut when relay is On.

Connect the power plug of the relay box in a power socket. Connect inverter mains cord to the socket provided on the Relay box. Connect the 2 pin PV connector to the relay drive output connector on the right side of the charge controller. Now when the battery charge voltage is more than 13.5 V / 27 V / 54 V, the relay will turn on. This will cut-off the mains supply to the inverter and thus save electricity. Note that in this condition, the load connected from the inverter will be driven by the battery while the battery is being charged by the solar panels. For use as Night Light Switch: Night Light Switch Connection diagram Program the parameter Relay usage to 1 (Night Light switch). Set Night Light switch parameter to 1 for dusk to dawn operation or 2 14 hours of operation after dusk. Inside the relay box the tag going to the output socket should come from the N/O contact of the relay. Now the relay will be turned on at dusk and remain on till dawn or for number of hours as set in the parameters. When the relay is on, the night light connected on the socket of the relay box will be supplied power through the relay.

Technical specifications CC-MPPT-1224-20/40 CC-MPPT-36-20/40 CC-MPPT-48-20/40 Technology Dual Channel Interleaved Buck Converter Battery bank voltage 12 / 24V 36 Volts 48 Volts Maximum charging current: Maximum solar panel voltage: 20 A / 40 A 20 A / 40 A 20 A / 40 A 70 Volts 100 Volts 100 Volts Maximum power point voltage range Battery voltage to 70V Battery voltage to 77V Battery voltage to 77V Buck converter duty cycle range 0 100% 0-100% 0-100% Idle current from battery (typical) 21 / 18 ma (Sleep mode) 21 / 18 ma (Sleep mode) 21 / 18 ma (Sleep mode) Other Features 1. When load is On, battery is connected to load output. Load output is designed for maximum 20A DC Current. In case this current is exceeded, the load is Shut Off. In this case Overload Shutoff message is displayed. Reduce load and press NEXT key for 2 Seconds to reset Overload shutoff condition. 2. In case battery voltage drop below 11.2/22.4/44.8V again the load is shut off. It will automatically reset when battery voltage rises above 12V / 24V / 48V. Press NEXT key for 2 Seconds to reset this condition manually. 3. To reset all programmable parameters to their factory default values and to reset the total energy harvested KWHr value, remove solar panel and battery connections. Then keep INCR and DECR keys pressed while connecting the battery connections. After a few seconds Writing default parameters message will be displayed and all parameters will be reset. User Manual revision status: Revision date: 07/04/2015 for SW ver 3.14 Company Contact details: Systellar Innovations Shankar Chowk, Delhi Road, Meerut 250002 Ph: 0121-2400394 Email: info@systellar.in www.systellar.in